Tips and information on automation- and control-technology
PI-Service-News 03/2022

Post from Kleverle for
#persname#!


Interesting innovations and the best tips for everything to do with automation- and control-technology

Show in browser

Logo Kleverle


Reading variables from
S5-F-CPU over network


- DLL-file with function-call for
reading PLC-variables from
F-CPUs via S5-LAN++
- supported formats:
bit, byte, word, double word,
real
- supported variables:
flags, in-/output, timer,
counter, s-flags, DB and DX

Read now





Step5/7-programming PG-2000 V6.00
Changes:
S5+S7:
- PLC-deduction also with
many blocks
- Block-list scrollable with
mouse-wheel
S7:
- Change of
- Real-numbers
- FC-blocks
- DB-instance
- Call-instruction with
parameter from FB and FC

Download
Jetzt lesen





bus cable (PPI/MPI/DP) length 1m

- Connect Panel/PLC to PLC,
easy and fast
- plug in and screw together
without much effort
- connections between 2
participants in seconds
- Saving time + purple bus-
cable + 2x bus-connector

Read now





Network for each S5-PLC

- read/write data via
PD-interface
- fastest installation (assign
IP-address, plug in,
communicate)
- S7-PLC reads/writes data with
PUT/GET without program-
change in S5
- S7-panel as a replacement
for defective/not deliverable
S5-panels

Read now




From Kleverle's tool box: (tips for the practitioner)
  • PUT/GET-connection configured in PLC, GET-block reports error-code: 1
    When using a PUT/GET-connection, function-blocks are loaded and used from the Siemens-block-library. Although the connection was created correctly and the used function-block is identical to that from various example-projects, error 1 always occurs.
    Remedy:
    Siemens-software has several block libraries, one is the standard-library->Communication Blocks and one is the standard-library->System Function Block.
    - For S7-300 via the integrated interface of the CPU, the blocks from communication blocks are to be used
    - for S7-400 and WinAC the blocks from System Function Blocks are to be used
  • Several active connections via S7-LAN module, now additional participants and they don't get ONLINE
    S7-LAN-module installed on S7-PLC, participants are already reading/writing PLC-data via the module. Now there is another participant who should also read/write data from the controller via the module. However, this participant always gets an access error. Only when other participants are switched off can the participant go ONLINE.
    Remedy:
    The PLC has a certain number of possible communications. These are defined in the hardware-configuration of the controller. The S7-LAN-module uses a new connection for every communication that takes place over it. However, if these communications are limited in the controller, i.e. too few channels are specified, the module cannot set up any further ones. The number of possible connections must then be increased via the hardware-configuration of the controller.