Oxygen - Service - Controller II
Analyzer for determination of residual oxygen in gases
• integrated zirconium probe
• high metering precesion
• automatic switch of range %, ppm, E-xx
• high resolution of the display areas
• integrated switchable pump
• integrated flowmeter with regulating valve 0 - 10 l/h
• probe offset with known O2-content of test gas possible
• free adjustable limit values for the relay outputs
• configurations are code protected against accidental modifications
• configurations are stored with mains failure protection
• high metering precesion
• automatic switch of range %, ppm, E-xx
• high resolution of the display areas
• integrated switchable pump
• integrated flowmeter with regulating valve 0 - 10 l/h
• probe offset with known O2-content of test gas possible
• free adjustable limit values for the relay outputs
• configurations are code protected against accidental modifications
• configurations are stored with mains failure protection
| Technical Specifications: | |
| Supply voltage: | 230V/AC 50Hz |
| Power consumption: | 200 watt |
| Display: | illuminated, detailed graphics display (70 x 35 mm) 5 LEDs (power, heating, relay outputs) |
| Handling/Configuration: | integrated keypad |
| Interfaces: |
1 x analogue outputs: 0/4 - 20mA 3 x digital outputs: 230V / 2A 2 x sample gas connection 4mm VA-pipe (in-/outputs) 1 x D-Sub-female for RS232/422(optional) |
| Operating temperature: | |
| Case: | metal case in the versions (19"-slot / table device / service carrying case) |
| Dimensions: | 19"-slot: 440 x 370 x 135 mm table device: 360 x 350 x 150 mm service carrying Case: 360 x 350 x 150 mm |
Oxygen analysis in industrial gases ![]() You need a continuous measurement of the concentration of oxygen without any configuration of the device or a switch of range of measurement? No problem, with the OSC-II-devices you are right. It shows you the concentration from % down to E -24 without any action from you. It switches automatically the ragne of measurement. | Documentation of oxygen concentration ![]() The integratet current output issues the actual concentration
in the range of 0/4 - 20mA via free definable limits.
|
Free definable limits ![]() You need some limits? No problem, with the OSC-II-devices you will be able to define 3 relay outputs (toggle switch) like UG (down level) or OG (top level) or as a ready-flag (internal probe has working temperature). | Fuzzy controller with the OSC-II ![]() Through 3 free configurable limits (of each kind) you won´t be able to realice a fuzzy-controller of your heat treatment furnace. |
to the order datas
| article: | |||||
|---|---|---|---|---|---|
| Art. ID. | name | price | quantity | ||
| 9110.1 | OSC-II 19" Rack Device OxygenServiceController 100% - 10E-24% |
4090,- € | |||
| 9110.3 | OSC-II Service-Transport-Box OxygenServiceController 100% - 10E-24% |
4397,- € | |||
| 9110.2 | OSC-II Desktop Device OxygenServiceController 100% - 10E-24% |
4295,- € | |||
| 9110.0 | OSC-II Wallcase (without probe, pump, DMM) |
2556,- € | |||