TELE-BOOK (TB)
PLC-remote maintenance also available from the car, with 12V power supply
- Secured modem-protocol, no additional software needed
- High throughput
- All online functions possible
- Easy handling because of menu navigation and display in plain text
- Easy and quick configuration by menu item initial configuration
- Multi-stage password levels provide high data security
- Cost improvement because of call-back function
- Integrated telephone directory
- Compatible to all TELE-Network-devices
- EMC-compatible circuit arrangement
- Other PLC-protocols with optional Tele-Manager reloadable
- Software-updates via telephone line transferable
- Incl. power supply unit
| Technical Specifications: | |
| Supply voltage: | 24V/DC (12 - 36V) |
| Power consumption: | 3 watt |
| Display: | expressive LCD-display |
| Handling/Configuration: | integrated keypad Tele-Manager |
| Interfaces: |
to the PLC:
RS232: 9,6 KBd - 115,2 KBd / fully assigned to the PD/PC:
TTY/20mA current loop (100 % mechanically and electr. compatible)RS232: 9,6 KBd - 115,2 KBd / with a 1on1-cable to the PC others:
1 x PCMCIA |
| Integrated modem: | - |
| Operating temperature: | 5 - 55°C |
| Case: | powder coated metal table case |
| Dimensions: | 233 x 162 x 39 mm |
Use in the car with a 12V supply only ![]() Your’re on road with your car and your employee reports
a failure? What next? Approach the next parking place and try to get a telephone
line to solve the problem? Or solve the problem in your head? Hit the next parking
place and start your Tele-Book which is plugged on your car’s cigarette
lighter, and build-up a connection to your installation. With the notebook you
will solve the problem within a short time.
| Remote maintenance / telecontrol of PLC-devices ![]() Access to the connected PLC takes place by coupling via Analogue-,
ISDN- (only with AB-adapter) and GSM-(only with external GSM-modem)-line.
|
PLC-coupling (data exchange between PLC-devices) ![]() Your pumping stations report the water levels of the central
control via telephone network. The central office itself can of course transmit
commands/messages to the substations as well. Thereto no dedicated line is required,
a “normal” telephone connection is sufficient because the devices
hangs up the line after occured message.
| Failure report transmission released by the PLC ![]() Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, to your mobile phone as SMS or to your pager. |
Sending ASCII-data to a PC ![]() Your car park or control sends the configuration/capacity
utilisation to a PC with a modem, so that the data can be used for further processing.
| Direct-mode „extended serial interface“ ![]() There is an unsupported control or data logger or converter
integrated in your installation which protocol is not supported? No problem,
the signs that the PC in the office sends will be transferred via telephone
line by the Direct-mode , and on-site reproduced by the TP/TB. The way back
is identical. So in that case there’s also a communication to the electronic
devices available.
|
to the order datas
| article: | |||||
|---|---|---|---|---|---|
| Art. ID. | name | price | quantity | ||
| 9380 | TELE-BOOK PLC remote maintenance as PLC-or PG-TELE switchable |
1099,- € | |||
to the order datas
| options: | |||||
|---|---|---|---|---|---|
| Art. ID. | name | price | quantity | ||
| 9370-11 | Option ASCII-TELE ASCII-transfer of DB-contents from S5/7-PLC to a modem |
251,- € | |||
| 9370-3 | Option FAX-TELE sending DB-contents from S5/7-PLC's to a fax machine |
251,- € | |||
| 9370-7 | Option H1 with CP-cable programming of S5-PLC's with a CP via H1-bus with PD-path selection |
251,- € | |||
| 9370-6 | Option L1 with CP-cable programming of S5-PLC's with a CP via L1-bus with PD-path selection |
251,- € | |||
| 9370-5 | Option L2 with CP-cable programming of S5-PLC's with a CP via L2-bus with PD-path selection |
251,- € | |||
| 9370-2 | Option PLC-TELE transfer of DB-contents between S5/7-PLC's |
251,- € | |||
| 9370.A | Option TP+TB AEG TELE-PROFessional for AEG A120,A250 PLC- or PD-TELE switchable |
1273,- € | |||
| 9370.AB | Option TP+TB Allen-Bradley TELE-PROFessional for Allen-Bradley PLC- or PD-TELE switchable |
1273,- € | |||
| 9370.B | Option TP+TB Bosch TELE-PROFessional for Bosch |
1273,- € | |||
| 9370.G | Option TP+TB GE-Fanuc TELE-PROFessional for GE-Fanuc |
1273,- € | |||
| 9370.KM | Option TP+TB Klöckner-Moeller TELE-PROFessional for Klöckner-Moeller |
1273,- € | |||
| 9370.M | Option TP+TB Mitsubishi TELE-PROFessional for Mitsubishi |
1273,- € | |||
| 9370.P | Option TP+TB Pilz TELE-PROFessional for Pilz PSS |
1273,- € | |||
| 9370.T | Option TP+TB Telemechanique TELE-PROFessional for Telemechanique |
1273,- € | |||
to the order datas
| accessories: | |||||
|---|---|---|---|---|---|
| Art. ID. | name | price | quantity | ||
| 9391.1 | 24V DC power-supply unit 625mA Primary 110V - 240 VAC Euro+USA-plug |
39,- € | |||
| 9381.KABEL | Analogue cable for TAE-modem PCMCIA PCMCIA-modemcard connection <=> TAE plug Germany/USA (spare part) |
51,- € | |||
| 9370-ISDN | ISDN-adapter for analogue terminals full ISDN-functionality e.g. call waiting, 3-way conferencing, broker's call |
251,- € | |||
| 9370-COM | Serial PCMCIA-adapter for TP + TB |
205,- € | |||
| 9371-6 | Servicebag for TP, TB + TP-II-FLAT |
59,- € | |||
| 9372-24 | Power connector 3pins big connector plug lockable by jack with screws |
3,- € | |||
| 9381 | TAE-modemPCMCIA-card for TELE-BOOK pcmcia-card inclusive telefon-lead and TAE-adapter |
205,- € | |||
| 9370-TAE | TAE junction box analogue telephone box (NFN) for on-wall mounting |
20,- € | |||
| 9380-9S | Connecting cable TELE-Book on Slot-PLC from Siemens |
51,- € | |||