S5-TCP/IP 100




Turbo ethernet for PLC-oldie Simatic S5
TCP/IP-& H1-interface connection
for SIMATIC S5
!!! No support because of obsolete !!!
more...
ARTNR: 200-4000-01
S5-TCP/IP 100
Obsolete
EAN number: | 4260363244053 | |
HS-code: | 85423110 |
Remote maintenance
![]() |
||||||||
secured modem-protocol |
✓
|
✓
|
✓
|
|||||
additional software needed |
Siemens TS -Software
|
Siemens TS -Software
|
VPN-Client
|
VPN-Client
|
||||
Providing WinTELEPROF-software |
✓
|
✓
|
✓
|
|||||
modem |
analogue/ISDN
|
analogue
|
opt. via PCMCIA
|
analogue/GSM
|
analogue/ISDN/GSM
|
internet-connection
|
internet-connection
|
internet-connection
|
modem for world wide use |
✓
|
✓
|
✓
|
✓
|
✓
|
|||
interfaces | ||||||||
MPI/Profibus |
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
||||
RS232 |
2x
|
2x
|
2x
|
1x
|
1x
|
|||
TTY |
2x
|
2x
|
2x
|
1x
|
||||
PCMCIA |
2x (optionally)
|
1x
|
1x
|
|||||
Ethernet |
10/100BaseTx
|
1x
|
1x
|
5x
|
||||
USB |
2x
|
1x
|
||||||
LCD-display |
✓
|
✓
|
✓
|
✓
|
instead 10 LEDs
|
instead status-LED
|
instead webserver
|
instead webserver
|
supported PLC-protocols * | ||||||||
S7 |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
||
S5 |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
||||
Pilz PSS |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
Allen-Bradley |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
AEG |
✓ (optional)
|
✓ (optional)
|
||||||
Bosch |
✓ (optional)
|
✓ (optional)
|
||||||
Telemecanique |
✓ (optional)
|
✓ (optional)
|
||||||
GE-Fanuc |
✓ (optional)
|
✓ (optional)
|
||||||
Klöckner-Moeller |
✓ (optional)
|
✓ (optional)
|
||||||
Mitsubishi |
✓ (optional)
|
✓ (optional)
|
||||||
SMS-sending/Pager(S5/S7) |
✓
|
✓
|
✓
|
✓ (no pager)
|
only for analogue / ISDN
|
|||
HMI-messaging module(S5/S7) |
✓
|
✓
|
||||||
SMS-receive with GSM |
✓
|
|||||||
DTMF with analogue |
✓
|
|||||||
e-mail-dispatch |
✓
|
✓
|
✓
|
|||||
FAX-dispatch(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
only for analogue / ISDN
|
||||
PLC-data coupling(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
✓
|
|||
ASCII-transfer from S5/S7 |
✓
|
✓ (optional)
|
✓ (optional)
|
only with ASCII-LAN
|
||||
internet-coupling |
✓
|
|||||||
Usage as dial-up-router |
✓
|
✓
|
||||||
power supply |
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
dimensions w x h x d (in mm) |
High: 67 x 280 x 170
FLAT: 300 x 175 x 70 |
300 x 175 x 66
|
235 x 162 x 37
|
90 x 162 x 54
|
40 x 125 x 115
|
42 x 15 x 65
|
65 x 43 x 17
|
154 x 92 x 28
|
* other PLC types on request |
- S5-LAN++
- plug-in module for the S5 PG interface
- plug in and access S5-PLC via network without changing the program
- emulation of S7-TCPIP RFC1006 protocol
- PUT/GET from S7-1200/1500 to S5-PLC
- integrated multiplexer, multiple communication in parallel on S5-PLC
- PLC-connection to other S5-LAN++
- 24V supply directly from S5 (115U to 155U), external 24V DC possible
- Protocol converter S7-TCPIP RFC1006 <=> H1 (ISO)
- H1 (ISO)-devices via S7-TCPIP RFC1006 into the network
- for each H1 (ISO)-participant a separate IP-address or shared IP-address with its own TSAP
- up to 50 parallel S7-TCPIP connections
- separation between company network and machine network
- company network via LAN and/or WIFI, machine network via LAN
- for DIN rail mounting
- Power supply 24V DC via spring-terminal
- Board for S5-115U, S5-135U, S5-150U and S5-155U
- Integrated 4-port ethernet-switch
- Supported protocols:
- TCP/IP
- ISO on TCP (RFC1006)
- ISO (H1)
- Modbus on TCP
- PLC Header
- DNS, DHCP, SNMP-services after MIB II, FTP
- Job types:
- Send direct
- Receive direct
- Fetch active
- Fetch passive
- Write active
- Write passive
- Fetch on Event
- Space requirement 1 slot, for S5-115U adaptation-capsule required!

S5-115U/135U/150U/155U and need further processing of data via network and PG interface too slow?
Plug the "S5-TCPIP 100" interface-card into a free slot in the rack, integrate the card into the S5 and nothing
stands in the way of communication. Access the controller-data "parallel" to the PG-interface with "Power",
regardless of whether it is "TCP/IP" or "ISO on TCP (RFC1006)", "ISO (H1)", "Modbus on TCP" or "SPS header",
the interface-card reacts to the various protocols according to your configuration and returns the required
data.
With the integrated 4-way-switch, several LAN-participants can be connected to the card and thus to the controller.

accessories:
CF Card 256MB
Additional security options for your Parameterization-data (is for the operation of the S5-TCP/IP 100 not mandatory)

plus VAT. and shipping
S5-TCP/IP 100 Obsolete
TCP/IP-& H1-interface connection for SIMATIC S5 !!! No support because of obsolete !!!

plus VAT. and shipping
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions

plus VAT. and shipping
CONNECT protocol converter Din-Rail-mounting
Conversion S7-TCPIP RFC1006 <=> H1 (ISO) a separate IP address for each H1 (ISO) device machine network decoupled one-click mounting

plus VAT. and shipping
Internet

The simple and quick router solution for automation

Network-connection for the S5-PLC +++ Network to PG-interface +++ Of developer and manufacturer +++ Remotemaintenance via Internet +++ S5 (CP-343-1 compatible)

Remotesupport without configuration / Machine access without IT
CF Card 256MB
Additional security options for your Parameterization-data (is for the operation of the S5-TCP/IP 100 not mandatory)

plus VAT. and shipping