Data-backup S7-PLC PN-port on USB-Stick - Process Informatik Entwicklungsgesellschaft mbH

Data-backup S7-PLC PN-port on USB-Stick


S7 PLC data Hardware-independent safe/restore directly to/from the USB-STICK universally with PLC-Trigger!

USB-port for EtherSens-devices (data storage)
Extension for:
- DB-backup/restoure-function
- CSV-recording
Maximum current: 200mA for 5V DC

Product Overview:

SPS data backup without installation of additional software on each USB-STICK, SD-CARD and every FTP server.
Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.

Highlights:

  • Thanks to the USB stick as a storage medium, you can back up machine data in the shortest possible time and transport it to other machines as required.
  • When delivering the same machine again, customers can bring their data directly for acceptance, no PLC knowledge required! Insert the USB stick and set the PLC trigger!


    more...
    105,00 € plus VAT. and shipping

    ARTNR: 9230-USB
    Extension USB-port
    EAN number: 4260363248624
    HS-code: 85423190



    Product Overview:

    SPS data backup without installation of additional software on each USB-STICK, SD-CARD and every FTP server.
    Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
    No matter if daily data backup , storage processes, machine change or after every production cycle .
    Writes all production relevant data to your server for archiving and further processing.
    Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.

    Highlights:

    • Thanks to the USB stick as a storage medium, you can back up machine data in the shortest possible time and transport it to other machines as required.
    • When delivering the same machine again, customers can bring their data directly for acceptance, no PLC knowledge required! Insert the USB stick and set the PLC trigger!

    • Triggering directly out of the S7 controler , thus no time lag and delays due to external circuits or regulator.
    • No change at your Simatic S7 controller.
    • Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
    • Bidirectional Backup & Playback!

    ! DOUBLE FUNCTIONS for PLC experts!

    • ALARM_MESSAGE DISPATCH INTEGRATED

      • Freely selectable fault annunciator integrated, not only in case of faulty recording, no, a directly operation monitor for your production plant .
      • Resets any error messages send by mail to any number of recipients.
      • As a result, no plant supervisor escapes a malfunction!
      • Avoid high costs caused by machine downtime!

    Application areas:

    -
    Save data on your FTP data base , like production data and all relevant system parameters.
    - Use a simple
    USB-STICK, SD-CARD or a FTP server as data backup server , no extra software necessary.
    - Backups before
    System conversions / changes !
    - Save freely selectable DB contents and restore them!
    - Link S7-Siemens PLC to any TCP/IP devices and get access to the process data directly.
    - Schedule-relevant data, e.g. after finished palletizing
    PLC trigger controlled storing.

    Configuration:

    The configuration takes place directly into the
    integrated web server .
    Thanks to the designed flash memory, data can not be lost, which means a device can be easily tested at the office and then sent to the construction site__.
    Even in the event of power failure or other supply disruptions
    there is no danger to the data.
    After configuration
    no additional PC is required **. The installation is self-explanatory and can be carried out on-site by untrained personnel.
    Supply voltage: 24V DC +/- 20%
    Power consumption: 4 watt
    Interfaces: USB-port type A (max. 200mA)
    Operating temperature: 0 - 55°C
    Case: PlugIn-board
    Dimensions: 74,9 x 86 x 20 mm
     
    Scope of delivery: PlugIn-board
    Installation into the EtherSens-device
    All prices plus costs of delivery, shipping insurance and VAT.
    All prices plus costs of delivery, shipping insurance and VAT.
    All prices plus costs of delivery, shipping insurance and VAT.

    7000
    Data-backup S7-PLC PN-port on USB-Stick

    S7 PLC data Hardware-independent safe/restore directly to/from the USB-STICK universally with PLC-Trigger!
    Quickbestellung INFOMAIL
    by e-mail
    369,00 €
    plus VAT. and shipping


    9201
    EtherSens Basic

    Operating as a client or access-point Configuration via web-server Supply: 24V DC
    Quickbestellung INFOMAIL
    by e-mail
    264,00 €
    plus VAT. and shipping


    Automatic-mode

    Main downloads

    Versionstory

    Other downloads

    Documentation

    Extension

    Support-videos