Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK
Data-backup S7-PLC PN-port on USB-Stick - Process Informatik Entwicklungsgesellschaft mbH

Data-backup S7-PLC PN-port on USB-Stick Download


S7 PLC data Hardware-independent safe/restore directly to/from the USB-STICK universally with PLC-Trigger!

PPI/MPI/Profibus up to 12Mbit/s

Product Overview:

SPS data backup without installation of additional software on each USB-STICK, SD-CARD and every FTP server.
Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.

Highlights:

  • Thanks to the USB stick as a storage medium, you can back up machine data in the shortest possible time and transport it to other machines as required.
  • When delivering the same machine again, customers can bring their data directly for acceptance, no PLC knowledge required! Insert the USB stick and set the PLC trigger!


    more...
    variants:

    359,00 € plus VAT. and shipping

    ARTNR: 9352-USB
    MPI-USB-cable 3m
    EAN number: 4260363240598
    HS-code: 85444290
    Weight: 0.24 kg



    S7

    PPI-Bus
    PPI 9.6 KBit/s - 19.2 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Multimaster 9.6 KBit/s - 187.5 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    MPI-Bus
    19.2 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    187.5 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    1.5 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    Profibus
    9.6 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    19.2 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    45.45 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    93.75 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    187.5 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    500 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    1.5 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    3.0 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    6.0 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    12.0 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    Profibus-profile
    DP
    x(12)
    x
    x
    x
    x
    x
    x
    x
    x
    standard
    x(12)
    x
    x
    x
    x
    x
    x
    x
    x
    universal(DP/FMS)
    x
    x
    x
    x
    x
    x
    x
    x
    RS 232
    9.6 KBit/s
    x(19)
    x(19)
    19.2 KBit/s
    x
    x
    38.4 KBit/s
    x
    x
    57.6 KBit/s
    x(9)
    x(9)
    115.2 KBit/s
    x(9)
    x(9)
    USB
    USB 1.1 (6)
    x(1)
    x
    x(2)
    LAN
    10/100BaseTx
    x(7)
    x
    x
    x
    x
    WIFI
    2.4 GHz
    x
    TeleService operation
    with S7-300/400
    x(14)(18)
    x(14)(18)
    baud rates at TS-operation directly at the PC
    9.6 KBit/s
    x
    x
    19.2 KBit/s
    x
    x
    38.4 KBit/s
    x(8)
    x(8)
    57.6 KBit/s
    x(8)
    x(8)
    baud rates at TS-operation directly with a modem
    9.6 KBit/s
    x
    x
    19.2 KBit/s
    x
    x
    38.4 KBit/s
    x
    x
    57.6 KBit/s
    x
    x
    115.2 KBit/s
    x
    x
    HMI
    9.6 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    19.2 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    38.4 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    57.6 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    115.2 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    update
    firmware-update
    x(10)
    x(10)
    x(15)
    x(15)
    x(15)
    x(15)
    x(15)
    x(15)
    x(15)
    input/online help                  
    keypad
    x
    x
    x
    x(21)
    x(21)
    x(21)
    x(21)
    display
    x
    x
    x
    x
    x(21)
    x(21)
    x(21)
    x(21)
    PD connections (maximum)                  
    PLCVCOM
    1
    1
    1
    1
    1
    1
    1
    1
    RFC1006
    8
    8
    32
    32
    32
    AG connections (maximum)
    passive subscriber
    1
    15
    15
    15
    15
    15
    15
    15
    15
    active subscriber
    126
    126
    126
    126
    126
    126
    126
    126
    126
    more functions                  
    integrated PLC-firewall
    x
    x
    x
    display diagnostic-buffer in the webbrowser
    x
    x
    x
    webserver for configuration
    x
    x
    x
    x
    x
    Remote access over existing VPN-channel
    x
    x
    x
    x
    x
    Access via existing WLAN-channel
    x
    x
    x
    x
    x
    status/control variable
    x
    x
    x
    x
    x
    S7 on S7/S5 DB exchange
    x
    x
    x
    x
    x
    S5 on MPI DB exchange
    only as S5toMPI
    S7 on MPI (Send/Fetch)
    x
    x
    x
    x
    x
    Profinet Gateway
    x
    x
    x
    x
    x
    Time in PLC from NTP-server
    x
    x
    x
    x
    x
    galvanic separation                  
    to the bus (screen connected through)
    1KV
    1KV
    1KV
    1,5KV
    1KV
    1,5KV
    1,5KV
    1,5KV
    1,5KV
    mounting                  
    wall monuting
    (with opt. wall mounting-set)
    x
    x
    x
    x
    upgrading with
    CheapConn+cable
    x
    x
    x
    x
    supports
    WIN 98
    x
    x(3)
    x
    x
    x
    x
    x
    WIN 98 SE
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN ME
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN NT
    x
    x(5)
    x(5)
    x
    x(5)
    WIN 2000
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN XP Home (4)
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN XP Professional
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Vista(32bit)
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Win7(32bit)
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Win7(64bit)
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    Win8/8.1
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    Win10
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    Win11
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)

    (1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1
    (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3
    (3) only serial communication
    (4) Siemens Step7 V5.2 and higher dont run with this operationing system
    (5) USB-communication is only possible with the special driver for Win NT
    (6) USB 2.0 is backward compatible to 1.1
    (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch
    with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation
    (8) only in combination with the MPI-Speed-driver („continously-active“)
    (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility
    (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the
    Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional)
    (11) only in the mode: MultiMaster-Mode
    (12) up to a maximum baud rate of 187.5 KBit/s
    (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port.
    (14) with the use of the TS-adapter / item number: 9350.TS
    (15) Update directly with PC and TIC-driver
    (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens
    (19) only at PPI-communication possible
    (20) Only with TIC-driver
    (21) with integrated webserver possible
    (22) No support of Siemens Step7-software possible
    (23) Only with USB and with TIC-driver

    Stephan Kern Elektrotechniker / Elektromeister
    Schleching

    GIA mbH
    51373 Leverkusen
    www.gia.de

    Zeller Presscontrol Systems und Automatisierungstechnik e.K.
    Wiesensteig
    www.zeller-presscontrol.com

    MSR-SERVICE GmbH
    Mansfeld
    www.msr-online.de

    proCtec GmbH
    Viernheim
    www.proctec.de

    JARUS Anlagen UG
    Bad Aibling
    www.jarus.de

    Wöhrle Belgium B.V.B.A.
    Mechelen , Belgium
    www.wohrle.be

    Elpro GmbH
    Berlin
    www.elpro.de

    Product Overview:

    SPS data backup without installation of additional software on each USB-STICK, SD-CARD and every FTP server.
    Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
    No matter if daily data backup , storage processes, machine change or after every production cycle .
    Writes all production relevant data to your server for archiving and further processing.
    Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.

    Highlights:

    • Thanks to the USB stick as a storage medium, you can back up machine data in the shortest possible time and transport it to other machines as required.
    • When delivering the same machine again, customers can bring their data directly for acceptance, no PLC knowledge required! Insert the USB stick and set the PLC trigger!

    • Triggering directly out of the S7 controler , thus no time lag and delays due to external circuits or regulator.
    • No change at your Simatic S7 controller.
    • Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
    • Bidirectional Backup & Playback!

    ! DOUBLE FUNCTIONS for PLC experts!

    • ALARM_MESSAGE DISPATCH INTEGRATED

      • Freely selectable fault annunciator integrated, not only in case of faulty recording, no, a directly operation monitor for your production plant .
      • Resets any error messages send by mail to any number of recipients.
      • As a result, no plant supervisor escapes a malfunction!
      • Avoid high costs caused by machine downtime!

    Application areas:

    -
    Save data on your FTP data base , like production data and all relevant system parameters.
    - Use a simple
    USB-STICK, SD-CARD or a FTP server as data backup server , no extra software necessary.
    - Backups before
    System conversions / changes !
    - Save freely selectable DB contents and restore them!
    - Link S7-Siemens PLC to any TCP/IP devices and get access to the process data directly.
    - Schedule-relevant data, e.g. after finished palletizing
    PLC trigger controlled storing.

    Configuration:

    The configuration takes place directly into the
    integrated web server .
    Thanks to the designed flash memory, data can not be lost, which means a device can be easily tested at the office and then sent to the construction site__.
    Even in the event of power failure or other supply disruptions
    there is no danger to the data.
    After configuration
    no additional PC is required **. The installation is self-explanatory and can be carried out on-site by untrained personnel.
    Access to MPI/Profibus without power supply
    Produkbild
    PLC-access in the production-system to "passive assemblies" such as frequency-converter or ET200 or on a bus-connector without PLC, not actually possible without 24V DC for the interface product.
    MPI-USB-cables 3m or 5m are supplied from the USB-interface of the PC and therefore do not require 24V DC from the connected participant. In addition, communication can also take place on the Profibus of a VIPA-PLC (no 24V DC).
    Supply voltage: 5V DC
    Power consumption: 2 watt
    Display: double lined LCD-display
    Handling/Configuration: Kabelmanager-Software
    keypad on the back
    Interfaces:
    to the PLC:
    PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
    to the PD/PC:
    USB 1.1 cable type A
    Galvanic separation: 1000V PPI/MPI/Profibus to the PC
    Operating temperature: 0 - 55°C
    Case: ABS-plastic case
    Dimensions: 146 x 41 x 29 mm
     
    Scope of delivery: MPI-USB-cable
    All prices plus costs of delivery, shipping insurance and VAT.

    accessories:

    9361-7
    T-Connector to PPI / MPI-Bus

    doubling of PPI/MPI/Profibus-port without bus connector
    Quickbestellung INFOMAIL
    by e-mail
    166,00 €
    plus VAT. and shipping


    84,00 €
    plus VAT. and shipping


    9391-HH
    DIN-rail-holder for MPI/PPI

    quick and easy assembling on the cap rail
    9350-WAND
    Wall-mounting

    for MPI/PPI + MPI-II + MPI-USB
    9350-9-CHP-CC
    Option CheapConn for MPI

    9350-9-CHP+9350-9-CHP-K already mounted
    Quickbestellung INFOMAIL
    by e-mail
    48,00 €
    plus VAT. and shipping


    9352-104-2
    MPI-PC104-card 2 channel up to 12Mbaud Obsolete

    equates to PC104-standard (90.2 x 95.9mm)
    9352-104
    MPI-PC104-card 1 channel up to 12Mbaud Obsolete

    equates to PC104-standard (90.2 x 95.9mm)
    9350-9-CHP-K
    Connecting cable MPIx to CheapConn

    9-pins 1 : 1 plated-through with shield
    Quickbestellung INFOMAIL
    by e-mail
    6,00 €
    plus VAT. and shipping


    9350-9-CHP
    CheapConn Busconnector

    for MPI/PROFIBUS inclusive variable insert
    Quickbestellung INFOMAIL
    by e-mail
    37,00 €
    plus VAT. and shipping


    9352-S7-BK
    S7-bus-coupler

    Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
    Quickbestellung INFOMAIL
    by e-mail
    42,00 €
    plus VAT. and shipping


    All prices plus costs of delivery, shipping insurance and VAT.

    9352-USB
    MPI-USB-cable 3m

    PPI/MPI/Profibus up to 12Mbit/s
    Quickbestellung INFOMAIL
    by e-mail
    359,00 €
    plus VAT. and shipping




    maximum 3 articles
    9352-USB.05M
    MPI-USB-cable 5m Obsolete

    PPI/MPI/Profibus up to 12Mbit/s
    Quickbestellung INFOMAIL
    by e-mail
    390,00 €
    plus VAT. and shipping




    maximum 3 articles
    9352-S7-USB
    S7-USB connector for Siemens S7 Controller

    universal USB-module on PPI/MPI/Profibus 9,6 KBit/s up to 12MBit/s
    Quickbestellung INFOMAIL
    by e-mail
    317,00 €
    plus VAT. and shipping




    maximum 3 articles

    All prices plus costs of delivery, shipping insurance and VAT.

    9352-LANCON
    S7-LAN connector for Siemens S7 PLC controller

    Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
    Quickbestellung INFOMAIL
    by e-mail
    423,00 €
    plus VAT. and shipping


    9359-1
    PG-USB-cable 3m for Siemens S5 Controller

    for PLC's + LED + metal case
    Quickbestellung INFOMAIL
    by e-mail
    145,00 €
    plus VAT. and shipping


    9350-9-DIAG
    DiagConn 90° Highend-connector

    for PROFIBUS with diagnosis function country of origin: Germany not preferential
    Quickbestellung INFOMAIL
    by e-mail
    54,00 €
    plus VAT. and shipping


    9359-LAN
    S5-LAN++

    Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
    Quickbestellung INFOMAIL
    by e-mail
    452,00 €
    plus VAT. and shipping


    9391.1
    24V DC power-supply unit 625mA

    Primary 110V - 240 VAC Euro+USA-plug
    Quickbestellung INFOMAIL
    by e-mail
    59,00 €
    plus VAT. and shipping


    9352.3
    USB-cable plug/plug type A-B-Mini 3m

    USB 1.1 / 2.0 up to 480 MBit
    Quickbestellung INFOMAIL
    by e-mail
    25,00 €
    plus VAT. and shipping