Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK
Data-backup S7-PLC PN-port on USB-Stick - Process Informatik Entwicklungsgesellschaft mbH

Data-backup S7-PLC PN-port on USB-Stick Download


S7 PLC data Hardware-independent safe/restore directly to/from the USB-STICK universally with PLC-Trigger!

integrated access-protection LAN <=> bus-side
- IP-address-filter
- MAC-filter
- read/write protection of individual variables,
inputs/outputs, blocks
Display of the S7-diagnostics-buffer in the
webbrowser
(no Simatic Manager/TIA Portal required)
increased performance/data throughput (up to
300%) like S7-LAN module
up to 32 parallel connections

Product Overview:

SPS data backup without installation of additional software on each USB-STICK, SD-CARD and every FTP server.
Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.

Highlights:

  • Thanks to the USB stick as a storage medium, you can back up machine data in the shortest possible time and transport it to other machines as required.
  • When delivering the same machine again, customers can bring their data directly for acceptance, no PLC knowledge required! Insert the USB stick and set the PLC trigger!


    more...
    variants:

    423,00 € plus VAT. and shipping

    ARTNR: 9352-LANCON++
    S7-LAN++ connector for Siemens S7 Controller
    HS-code: 85423190
    Weight: 0.06 kg



    S7

    PPI-Bus
    PPI 9.6 KBit/s - 19.2 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Multimaster 9.6 KBit/s - 187.5 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    MPI-Bus
    19.2 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    187.5 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    1.5 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    Profibus
    9.6 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    19.2 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    45.45 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    93.75 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    187.5 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    500 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    1.5 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    3.0 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    6.0 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    12.0 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    Profibus-profile
    DP
    x(12)
    x
    x
    x
    x
    x
    x
    x
    x
    standard
    x(12)
    x
    x
    x
    x
    x
    x
    x
    x
    universal(DP/FMS)
    x
    x
    x
    x
    x
    x
    x
    x
    RS 232
    9.6 KBit/s
    x(19)
    x(19)
    19.2 KBit/s
    x
    x
    38.4 KBit/s
    x
    x
    57.6 KBit/s
    x(9)
    x(9)
    115.2 KBit/s
    x(9)
    x(9)
    USB
    USB 1.1 (6)
    x(1)
    x
    x(2)
    LAN
    10/100BaseTx
    x(7)
    x
    x
    x
    x
    WIFI
    2.4 GHz
    x
    TeleService operation
    with S7-300/400
    x(14)(18)
    x(14)(18)
    baud rates at TS-operation directly at the PC
    9.6 KBit/s
    x
    x
    19.2 KBit/s
    x
    x
    38.4 KBit/s
    x(8)
    x(8)
    57.6 KBit/s
    x(8)
    x(8)
    baud rates at TS-operation directly with a modem
    9.6 KBit/s
    x
    x
    19.2 KBit/s
    x
    x
    38.4 KBit/s
    x
    x
    57.6 KBit/s
    x
    x
    115.2 KBit/s
    x
    x
    HMI
    9.6 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    19.2 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    38.4 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    57.6 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    115.2 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    update
    firmware-update
    x(10)
    x(10)
    x(15)
    x(15)
    x(15)
    x(15)
    x(15)
    x(15)
    x(15)
    input/online help                  
    keypad
    x
    x
    x
    x(21)
    x(21)
    x(21)
    x(21)
    display
    x
    x
    x
    x
    x(21)
    x(21)
    x(21)
    x(21)
    PD connections (maximum)                  
    PLCVCOM
    1
    1
    1
    1
    1
    1
    1
    1
    RFC1006
    8
    8
    32
    32
    32
    AG connections (maximum)
    passive subscriber
    1
    15
    15
    15
    15
    15
    15
    15
    15
    active subscriber
    126
    126
    126
    126
    126
    126
    126
    126
    126
    more functions                  
    integrated PLC-firewall
    x
    x
    x
    display diagnostic-buffer in the webbrowser
    x
    x
    x
    webserver for configuration
    x
    x
    x
    x
    x
    Remote access over existing VPN-channel
    x
    x
    x
    x
    x
    Access via existing WLAN-channel
    x
    x
    x
    x
    x
    status/control variable
    x
    x
    x
    x
    x
    S7 on S7/S5 DB exchange
    x
    x
    x
    x
    x
    S5 on MPI DB exchange
    only as S5toMPI
    S7 on MPI (Send/Fetch)
    x
    x
    x
    x
    x
    Profinet Gateway
    x
    x
    x
    x
    x
    Time in PLC from NTP-server
    x
    x
    x
    x
    x
    galvanic separation                  
    to the bus (screen connected through)
    1KV
    1KV
    1KV
    1,5KV
    1KV
    1,5KV
    1,5KV
    1,5KV
    1,5KV
    mounting                  
    wall monuting
    (with opt. wall mounting-set)
    x
    x
    x
    x
    upgrading with
    CheapConn+cable
    x
    x
    x
    x
    supports
    WIN 98
    x
    x(3)
    x
    x
    x
    x
    x
    WIN 98 SE
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN ME
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN NT
    x
    x(5)
    x(5)
    x
    x(5)
    WIN 2000
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN XP Home (4)
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN XP Professional
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Vista(32bit)
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Win7(32bit)
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Win7(64bit)
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    Win8/8.1
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    Win10
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    Win11
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)

    (1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1
    (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3
    (3) only serial communication
    (4) Siemens Step7 V5.2 and higher dont run with this operationing system
    (5) USB-communication is only possible with the special driver for Win NT
    (6) USB 2.0 is backward compatible to 1.1
    (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch
    with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation
    (8) only in combination with the MPI-Speed-driver („continously-active“)
    (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility
    (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the
    Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional)
    (11) only in the mode: MultiMaster-Mode
    (12) up to a maximum baud rate of 187.5 KBit/s
    (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port.
    (14) with the use of the TS-adapter / item number: 9350.TS
    (15) Update directly with PC and TIC-driver
    (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens
    (19) only at PPI-communication possible
    (20) Only with TIC-driver
    (21) with integrated webserver possible
    (22) No support of Siemens Step7-software possible
    (23) Only with USB and with TIC-driver

    Product Overview:

    SPS data backup without installation of additional software on each USB-STICK, SD-CARD and every FTP server.
    Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
    No matter if daily data backup , storage processes, machine change or after every production cycle .
    Writes all production relevant data to your server for archiving and further processing.
    Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.

    Highlights:

    • Thanks to the USB stick as a storage medium, you can back up machine data in the shortest possible time and transport it to other machines as required.
    • When delivering the same machine again, customers can bring their data directly for acceptance, no PLC knowledge required! Insert the USB stick and set the PLC trigger!

    • Triggering directly out of the S7 controler , thus no time lag and delays due to external circuits or regulator.
    • No change at your Simatic S7 controller.
    • Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
    • Bidirectional Backup & Playback!

    ! DOUBLE FUNCTIONS for PLC experts!

    • ALARM_MESSAGE DISPATCH INTEGRATED

      • Freely selectable fault annunciator integrated, not only in case of faulty recording, no, a directly operation monitor for your production plant .
      • Resets any error messages send by mail to any number of recipients.
      • As a result, no plant supervisor escapes a malfunction!
      • Avoid high costs caused by machine downtime!

    Application areas:

    -
    Save data on your FTP data base , like production data and all relevant system parameters.
    - Use a simple
    USB-STICK, SD-CARD or a FTP server as data backup server , no extra software necessary.
    - Backups before
    System conversions / changes !
    - Save freely selectable DB contents and restore them!
    - Link S7-Siemens PLC to any TCP/IP devices and get access to the process data directly.
    - Schedule-relevant data, e.g. after finished palletizing
    PLC trigger controlled storing.

    Configuration:

    The configuration takes place directly into the
    integrated web server .
    Thanks to the designed flash memory, data can not be lost, which means a device can be easily tested at the office and then sent to the construction site__.
    Even in the event of power failure or other supply disruptions
    there is no danger to the data.
    After configuration
    no additional PC is required **. The installation is self-explanatory and can be carried out on-site by untrained personnel.
    Management of the IP address
    Produkbild

    The IP filter is used to determine whether or not the entered IP-addresses or IP-address-ranges may communicate with the connected controllers via the module.
    The list can be edited centrally be switched with a button from "allowed" on "not allowed".

    Management of the data-areas
    Produkbild

    With the management of the data-areas it is determined whether the entered data-areas can be read/written via the module with the connected controllers. A central button for the function determines whether the specified inputs are "allowed" or "not allowed" are.
    The input itself is kept very simple: "r" for reading and "w" for writing, a ":" as a separator and then the data-area in S7-format. If there is only one CPU on the bus, the CPU-address does not even have to be specified, the participant on which the module is plugged in is used.

    Display diagnostic-buffer without Simatic-Manager
    Produkbild

    Via the connection-menu and the included bus-device-display, it is possible to display the diagnostics buffer of the respective device without having to open Simatic-Manager or TIA-Portal separately.
    The data received from the module is output directly in one piece without the hassle of changing tabs. All data at a glance.

    Supply voltage: 24V DC +/- 20%
    Power consumption: 2 watt
    Display: Web-Browser
    2 status-LEDs
    Handling/Configuration: Web-Browser
    TIC-Software
    Interfaces:
    to the PLC:
    PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
    to the PD/PC:
    PD/diagnosis jack
    10/100BaseTX RJ45-ethernet jack (auto select)
    Galvanic separation: 1500V PPI/MPI/Profibus to the PC
    Operating systems: MS-Windows NT, 2000, XP, Vista / Win7/8/10/11 32/64 Bit
    Protocols: RFC1006, DHCP, HTTP
    Operating temperature: 0 - 55°C
    Case: ABS-plastic case
    Dimensions: 65 x 43 x 17 mm
     
    Scope of delivery: S7-LAN++-module
    Power connector 2pins small
    All prices plus costs of delivery, shipping insurance and VAT.

    accessories:

    9391.1
    24V DC power-supply unit 625mA

    Primary 110V - 240 VAC Euro+USA-plug
    Quickbestellung INFOMAIL
    by e-mail
    59,00 €
    plus VAT. and shipping


    9391-USB
    USB-powercable for 24V DC, max. 3W

    USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
    Quickbestellung INFOMAIL
    by e-mail
    95,00 €
    plus VAT. and shipping


    84,00 €
    plus VAT. and shipping


    9636-CROSS
    Cross-cable 3m Cat5+, shielded

    RJ45 plug <=> RJ45 plug, twisted pinning
    9636-TCPIP
    Patch-cable 3m, Cat5+, shielded

    RJ45 plug <=> RJ45 plug, 1:1
    9352-24
    Power connector 2pins small

    cable coupling by screw-connector (small)
    Quickbestellung INFOMAIL
    by e-mail
    4,00 €
    plus VAT. and shipping


    9352-S7-BK
    S7-bus-coupler

    Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
    Quickbestellung INFOMAIL
    by e-mail
    42,00 €
    plus VAT. and shipping


    All prices plus costs of delivery, shipping insurance and VAT.

    9352-LANCON++
    S7-LAN++ connector for Siemens S7 Controller

    Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
    Quickbestellung INFOMAIL
    by e-mail
    423,00 €
    plus VAT. and shipping




    maximum 3 articles
    9352-LANCON
    S7-LAN connector for Siemens S7 PLC controller

    Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
    Quickbestellung INFOMAIL
    by e-mail
    423,00 €
    plus VAT. and shipping




    maximum 3 articles
    9352-S7-GATE
    S7-GATE connector with integrated firewall for Siemens S7-PLCs

    Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
    Quickbestellung INFOMAIL
    by e-mail
    499,00 €
    plus VAT. and shipping




    maximum 3 articles
    9352-S7-WIFI
    S7-BRIDGE

    Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI
    Quickbestellung INFOMAIL
    by e-mail
    741,00 €
    plus VAT. and shipping




    maximum 3 articles

    All prices plus costs of delivery, shipping insurance and VAT.

    9352-LANCON
    S7-LAN connector for Siemens S7 PLC controller

    Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
    Quickbestellung INFOMAIL
    by e-mail
    423,00 €
    plus VAT. and shipping


    9359-LAN
    S5-LAN++

    Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
    Quickbestellung INFOMAIL
    by e-mail
    452,00 €