Data-backup S7-PLC PN-port on SD-card
S7 PLC data Hardware-independent safe/restore directly to/from the SD-Card, universally with PLC-Trigger!
Extension-board for EtherSens-devices
4 x Analogue Input (switchable between U, I,
differential)
4 x analog OUT 0/4-20mA (24V)
Power consumption: 4W
Product Overview:
SPS data backup without installation of additional software on each SD-CARD and every FTP server.Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.
Highlights:
- Triggering directly out of the S7 controler , thus no time lag and delays due to external circuits or regulator.
- No change at your Simatic S7 controller.
- Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
- Bidirectional Backup & Playback!
more...
149,00 € plus VAT. and shipping
ARTNR: 9230-AIO-V1.1
Extension Analog-IO V1.1
EAN number: | 4260363246958 | |
HS-code: | 85423190 |
Product Overview:
SPS data backup without installation of additional software on each SD-CARD and every FTP server.Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.
Highlights:
- Triggering directly out of the S7 controler , thus no time lag and delays due to external circuits or regulator.
- No change at your Simatic S7 controller.
- Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
- Bidirectional Backup & Playback!
! DOUBLE FUNCTIONS for PLC experts!
- ALARM_MESSAGE DISPATCH INTEGRATED
- Freely selectable fault annunciator integrated, not only in case of faulty recording, no, a directly operation monitor for your production plant .
- Resets any error messages send by mail to any number of recipients.
- As a result, no plant supervisor escapes a malfunction!
- Avoid high costs caused by machine downtime!
- All functions of the EtherSens-Basic fully usable!
Application areas:
- Save data on your SD-Card or FTP data base, like production data and all relevant system parameters.- Use a simple SD-Card or a FTP server as data backup server , no extra software necessary.
- Backups before System conversions / changes !
- Save freely selectable DB contents and restore them!
- Link S7-Siemens PLC to any TCP/IP devices and get access to the process data directly.
- Schedule-relevant data, e.g. after finished palletizing PLC trigger controlled storing.
Configuration:
The configuration takes place directly into the integrated web server .Thanks to the designed flash memory, data can not be lost, which means a device can be easily tested at the office and then sent to the construction site__.
Even in the event of power failure or other supply disruptions there is no danger to the data.
After configuration no additional PC is required **. The installation is self-explanatory and can be carried out on-site by untrained personnel.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 4 watt |
Interfaces: |
4 x Analogue Input V1.1 (switchable between U, I, differential) - Free configurable voltage-inputs with full 15-bit resolution: 0-50V, 0-40V, 0-20V, 0-10V, 0-5V, 0-4V, 0-2V, 0-1V, 0-0,5V, 0-0,25V - Free configurable differential voltage-inputs with full 15-bit resolution AI1 <-> AI2 and AI3 <-> AI4: +/-50V, +/-40V, +/-10V, +/-5V, +/-4V, +/-2V, +/-1V, +/-0,5V, +/-0,25V - Free configurable current-inputs with full 15-bit resolution: 0-20mA, 4-20mA - sample-rate of AD-converter can be selected: - fast = fast conversion / short precision - balanced = middle conversion / middle precision - exact = slow conversion / high precision - Measuring ranges after changing are calibrated to: - offset for 0V / 0mA - slope of voltage / current (ideal for end of measuring-range / full-scale) - Relative values can be configured to the original voltage- / current-values. For e.g.: On the voltage-input 10V were measured 5V, relative minimum = 0 kg, relative maximum = 100 kg, so the displayed-value is 50 kg Is minimum and maximum configured as 0 the measured voltage- / current-value will be displayed. 4 x analogue Output 0/4-20mA (source-power 24V) |
Handling/Configuration: | WEB-Browser |
Operating temperature: | 0 - 55°C |
Case: | PlugIn-board |
Dimensions: | 74,9 x 86 x 20 mm |
Scope of delivery: |
PlugIn-board Installation into the EtherSens-device |
All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.