Data-backup S7-PLC PN-port on SD-card - Process Informatik Entwicklungsgesellschaft mbH

Data-backup S7-PLC PN-port on SD-card


S7 PLC data Hardware-independent safe/restore directly to/from the SD-Card, universally with PLC-Trigger!

Extension-board for EtherSens-devices
Energy-analysis (EN 50470-1 EN 50470-3)
L1, L2, L3, N realtime analysis
Up to 8000 measurements / second
Hz / cos phi / power-factor
Energy consumption kWh
For Rogwski-coils up to 0,5V

Product Overview:

SPS data backup without installation of additional software on each SD-CARD and every FTP server.
Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.

Highlights:

  • Triggering directly out of the S7 controler , thus no time lag and delays due to external circuits or regulator.
  • No change at your Simatic S7 controller.
  • Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
  • Bidirectional Backup & Playback!

more...
352,00 € plus VAT. and shipping

ARTNR: 9230-ENERGY
Extension Energy-IO
EAN number: 4260363247214
HS-code: 85423190



Product Overview:

SPS data backup without installation of additional software on each SD-CARD and every FTP server.
Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.

Highlights:

  • Triggering directly out of the S7 controler , thus no time lag and delays due to external circuits or regulator.
  • No change at your Simatic S7 controller.
  • Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
  • Bidirectional Backup & Playback!

! DOUBLE FUNCTIONS for PLC experts!

  • ALARM_MESSAGE DISPATCH INTEGRATED

    • Freely selectable fault annunciator integrated, not only in case of faulty recording, no, a directly operation monitor for your production plant .
    • Resets any error messages send by mail to any number of recipients.
    • As a result, no plant supervisor escapes a malfunction!
    • Avoid high costs caused by machine downtime!

Application areas:

-
Save data on your SD-Card or FTP data base, like production data and all relevant system parameters.
- Use a simple
SD-Card or a FTP server as data backup server , no extra software necessary.
- Backups before
System conversions / changes !
- Save freely selectable DB contents and restore them!
- Link S7-Siemens PLC to any TCP/IP devices and get access to the process data directly.
- Schedule-relevant data, e.g. after finished palletizing
PLC trigger controlled storing.

Configuration:

The configuration takes place directly into the
integrated web server .
Thanks to the designed flash memory, data can not be lost, which means a device can be easily tested at the office and then sent to the construction site__.
Even in the event of power failure or other supply disruptions
there is no danger to the data.
After configuration
no additional PC is required **. The installation is self-explanatory and can be carried out on-site by untrained personnel.
Supply voltage: 100 - 240V AC, 50 - 60 Hz
Power consumption: 6 watt
Measurement:
  • Supports EN 50470-1, EN 50470-3, IEC 62053-21, IEC 62053-22, and IEC 62053-23 standards
  • Compatible with 3-phase, 3- or 4-wire (delta or wye), and other 3-phase services
  • Supplies total (fundamental and harmonic) active, reactive and apparent energy, and fundamental active/reactive energy on each phase and on the overall system
  • Less than 0.1% error in active and reactive energy over a dynamic range of 1000 to 1 at TA = 25°C
  • Less than 0.2% error in active and reactive energy over a dynamic range of 3000 to 1 at TA = 25°C
  • Supports current transformer and di/dt current sensors
  • Dedicated ADC channel for neutral current input
  • Less than 0.1% error in voltage and current rms over a dynamic range of 1000 to 1 at TA = 25°C
  • Supplies sampled waveform data on all three phases and on neutral current
Interfaces: 4 x voltage-input (100 - 240V): L1, L2, L3 and N
4 x distributor-terminal
4 x sensor-input Rogowski-coil (max. 0.5V) (L+K- / B+W-terminal ever phase + N)
Handling/Configuration: WEB-Browser
Overvoltage category: CAT IV
Insulation value
network <=> mains voltage:
1,5 KV
Operating temperature: 0 - 55°C
Case: PlugIn-board
Dimensions: 74,9 x 86 x 25 mm
 
Scope of delivery: PlugIn-board
Installation into the EtherSens-device
All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.

Automatic-mode

Main downloads

Versionstory

Other downloads

Documentation

Extension

Support-videos