Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK
Data-backup S7-PLC PN-port on SD-card - Process Informatik Entwicklungsgesellschaft mbH

Data-backup S7-PLC PN-port on SD-card Download


S7 PLC data Hardware-independent safe/restore directly to/from the SD-Card, universally with PLC-Trigger!

PPI/MPI/Profibus up to 12Mbit/s

Product Overview:

SPS data backup without installation of additional software on each SD-CARD and every FTP server.
Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.

Highlights:

  • Triggering directly out of the S7 controler , thus no time lag and delays due to external circuits or regulator.
  • No change at your Simatic S7 controller.
  • Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
  • Bidirectional Backup & Playback!

more...
variants:

359,00 € plus VAT. and shipping

ARTNR: 9352-USB
MPI-USB-cable 3m
EAN number: 4260363240598
HS-code: 85444290
Weight: 0.24 kg



S7

PPI-Bus
PPI 9.6 KBit/s - 19.2 KBit/s
x
x
x
x
x
x
x
x
x
Multimaster 9.6 KBit/s - 187.5 KBit/s
x
x
x
x
x
x
x
x
MPI-Bus
19.2 KBit/s
x
x
x
x
x
x
x
x
x
187.5 KBit/s
x
x
x
x
x
x
x
x
x
1.5 MBit/s
x
x
x
x
x
x
x
x
Profibus
9.6 KBit/s
x
x
x
x
x
x
x
x
19.2 KBit/s
x
x
x
x
x
x
x
x
x
45.45 KBit/s
x
x
x
x
x
x
x
x
93.75 KBit/s
x
x
x
x
x
x
x
x
187.5 KBit/s
x
x
x
x
x
x
x
x
x
500 KBit/s
x
x
x
x
x
x
x
x
1.5 MBit/s
x
x
x
x
x
x
x
x
3.0 MBit/s
x
x
x
x
x
x
x
x
6.0 MBit/s
x
x
x
x
x
x
x
x
12.0 MBit/s
x
x
x
x
x
x
x
x
Profibus-profile
DP
x(12)
x
x
x
x
x
x
x
x
standard
x(12)
x
x
x
x
x
x
x
x
universal(DP/FMS)
x
x
x
x
x
x
x
x
RS 232
9.6 KBit/s
x(19)
x(19)
19.2 KBit/s
x
x
38.4 KBit/s
x
x
57.6 KBit/s
x(9)
x(9)
115.2 KBit/s
x(9)
x(9)
USB
USB 1.1 (6)
x(1)
x
x(2)
LAN
10/100BaseTx
x(7)
x
x
x
x
WIFI
2.4 GHz
x
TeleService operation
with S7-300/400
x(14)(18)
x(14)(18)
baud rates at TS-operation directly at the PC
9.6 KBit/s
x
x
19.2 KBit/s
x
x
38.4 KBit/s
x(8)
x(8)
57.6 KBit/s
x(8)
x(8)
baud rates at TS-operation directly with a modem
9.6 KBit/s
x
x
19.2 KBit/s
x
x
38.4 KBit/s
x
x
57.6 KBit/s
x
x
115.2 KBit/s
x
x
HMI
9.6 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
19.2 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
38.4 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
57.6 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
115.2 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
update
firmware-update
x(10)
x(10)
x(15)
x(15)
x(15)
x(15)
x(15)
x(15)
x(15)
input/online help                  
keypad
x
x
x
x(21)
x(21)
x(21)
x(21)
display
x
x
x
x
x(21)
x(21)
x(21)
x(21)
PD connections (maximum)                  
PLCVCOM
1
1
1
1
1
1
1
1
RFC1006
8
8
32
32
32
AG connections (maximum)
passive subscriber
1
15
15
15
15
15
15
15
15
active subscriber
126
126
126
126
126
126
126
126
126
more functions                  
integrated PLC-firewall
x
x
x
display diagnostic-buffer in the webbrowser
x
x
x
webserver for configuration
x
x
x
x
x
Remote access over existing VPN-channel
x
x
x
x
x
Access via existing WLAN-channel
x
x
x
x
x
status/control variable
x
x
x
x
x
S7 on S7/S5 DB exchange
x
x
x
x
x
S5 on MPI DB exchange
only as S5toMPI
S7 on MPI (Send/Fetch)
x
x
x
x
x
Profinet Gateway
x
x
x
x
x
Time in PLC from NTP-server
x
x
x
x
x
galvanic separation                  
to the bus (screen connected through)
1KV
1KV
1KV
1,5KV
1KV
1,5KV
1,5KV
1,5KV
1,5KV
mounting                  
wall monuting
(with opt. wall mounting-set)
x
x
x
x
upgrading with
CheapConn+cable
x
x
x
x
supports
WIN 98
x
x(3)
x
x
x
x
x
WIN 98 SE
x
x
x
x
x
x
x
x
x
WIN ME
x
x
x
x
x
x
x
x
x
WIN NT
x
x(5)
x(5)
x
x(5)
WIN 2000
x
x
x
x
x
x
x
x
x
WIN XP Home (4)
x
x
x
x
x
x
x
x
x
WIN XP Professional
x
x
x
x
x
x
x
x
x
Vista(32bit)
x
x
x
x
x
x
x
x
x
Win7(32bit)
x
x
x
x
x
x
x
x
x
Win7(64bit)
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win8/8.1
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win10
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win11
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)

(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1
(2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3
(3) only serial communication
(4) Siemens Step7 V5.2 and higher dont run with this operationing system
(5) USB-communication is only possible with the special driver for Win NT
(6) USB 2.0 is backward compatible to 1.1
(7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch
with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation
(8) only in combination with the MPI-Speed-driver („continously-active“)
(9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility
(10) Update directly with PC or via Tele-Network if the cable is connected to a device of the
Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional)
(11) only in the mode: MultiMaster-Mode
(12) up to a maximum baud rate of 187.5 KBit/s
(13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port.
(14) with the use of the TS-adapter / item number: 9350.TS
(15) Update directly with PC and TIC-driver
(18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens
(19) only at PPI-communication possible
(20) Only with TIC-driver
(21) with integrated webserver possible
(22) No support of Siemens Step7-software possible
(23) Only with USB and with TIC-driver

Stephan Kern Elektrotechniker / Elektromeister
Schleching

GIA mbH
51373 Leverkusen
www.gia.de

Zeller Presscontrol Systems und Automatisierungstechnik e.K.
Wiesensteig
www.zeller-presscontrol.com

MSR-SERVICE GmbH
Mansfeld
www.msr-online.de

proCtec GmbH
Viernheim
www.proctec.de

JARUS Anlagen UG
Bad Aibling
www.jarus.de

Wöhrle Belgium B.V.B.A.
Mechelen , Belgium
www.wohrle.be

Elpro GmbH
Berlin
www.elpro.de

Product Overview:

SPS data backup without installation of additional software on each SD-CARD and every FTP server.
Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.

Highlights:

  • Triggering directly out of the S7 controler , thus no time lag and delays due to external circuits or regulator.
  • No change at your Simatic S7 controller.
  • Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
  • Bidirectional Backup & Playback!

! DOUBLE FUNCTIONS for PLC experts!

  • ALARM_MESSAGE DISPATCH INTEGRATED

    • Freely selectable fault annunciator integrated, not only in case of faulty recording, no, a directly operation monitor for your production plant .
    • Resets any error messages send by mail to any number of recipients.
    • As a result, no plant supervisor escapes a malfunction!
    • Avoid high costs caused by machine downtime!

Application areas:

-
Save data on your SD-Card or FTP data base, like production data and all relevant system parameters.
- Use a simple
SD-Card or a FTP server as data backup server , no extra software necessary.
- Backups before
System conversions / changes !
- Save freely selectable DB contents and restore them!
- Link S7-Siemens PLC to any TCP/IP devices and get access to the process data directly.
- Schedule-relevant data, e.g. after finished palletizing
PLC trigger controlled storing.

Configuration:

The configuration takes place directly into the
integrated web server .
Thanks to the designed flash memory, data can not be lost, which means a device can be easily tested at the office and then sent to the construction site__.
Even in the event of power failure or other supply disruptions
there is no danger to the data.
After configuration
no additional PC is required **. The installation is self-explanatory and can be carried out on-site by untrained personnel.
Access to MPI/Profibus without power supply
Produkbild
PLC-access in the production-system to "passive assemblies" such as frequency-converter or ET200 or on a bus-connector without PLC, not actually possible without 24V DC for the interface product.
MPI-USB-cables 3m or 5m are supplied from the USB-interface of the PC and therefore do not require 24V DC from the connected participant. In addition, communication can also take place on the Profibus of a VIPA-PLC (no 24V DC).
Supply voltage: 5V DC
Power consumption: 2 watt
Display: double lined LCD-display
Handling/Configuration: Kabelmanager-Software
keypad on the back
Interfaces:
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
USB 1.1 cable type A
Galvanic separation: 1000V PPI/MPI/Profibus to the PC
Operating temperature: 0 - 55°C
Case: ABS-plastic case
Dimensions: 146 x 41 x 29 mm
 
Scope of delivery: MPI-USB-cable
All prices plus costs of delivery, shipping insurance and VAT.

accessories:

9361-7
T-Connector to PPI / MPI-Bus

doubling of PPI/MPI/Profibus-port without bus connector
Quickbestellung INFOMAIL
by e-mail
166,00 €
plus VAT. and shipping


84,00 €
plus VAT. and shipping


9391-HH
DIN-rail-holder for MPI/PPI

quick and easy assembling on the cap rail
9350-WAND
Wall-mounting

for MPI/PPI + MPI-II + MPI-USB
9350-9-CHP-CC
Option CheapConn for MPI

9350-9-CHP+9350-9-CHP-K already mounted
Quickbestellung INFOMAIL
by e-mail
48,00 €
plus VAT. and shipping


9352-104-2
MPI-PC104-card 2 channel up to 12Mbaud Obsolete

equates to PC104-standard (90.2 x 95.9mm)
9352-104
MPI-PC104-card 1 channel up to 12Mbaud Obsolete

equates to PC104-standard (90.2 x 95.9mm)
9350-9-CHP-K
Connecting cable MPIx to CheapConn

9-pins 1 : 1 plated-through with shield
Quickbestellung INFOMAIL
by e-mail
6,00 €
plus VAT. and shipping


9350-9-CHP
CheapConn Busconnector

for MPI/PROFIBUS inclusive variable insert
Quickbestellung INFOMAIL
by e-mail
37,00 €
plus VAT. and shipping


9352-S7-BK
S7-bus-coupler

Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
Quickbestellung INFOMAIL
by e-mail
42,00 €
plus VAT. and shipping


All prices plus costs of delivery, shipping insurance and VAT.

9352-USB
MPI-USB-cable 3m

PPI/MPI/Profibus up to 12Mbit/s
Quickbestellung INFOMAIL
by e-mail
359,00 €
plus VAT. and shipping




maximum 3 articles
9352-USB.05M
MPI-USB-cable 5m Obsolete

PPI/MPI/Profibus up to 12Mbit/s
Quickbestellung INFOMAIL
by e-mail
390,00 €
plus VAT. and shipping




maximum 3 articles
9352-S7-USB
S7-USB connector for Siemens S7 Controller

universal USB-module on PPI/MPI/Profibus 9,6 KBit/s up to 12MBit/s
Quickbestellung INFOMAIL
by e-mail
317,00 €
plus VAT. and shipping




maximum 3 articles

All prices plus costs of delivery, shipping insurance and VAT.

9352-LANCON
S7-LAN connector for Siemens S7 PLC controller

Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
Quickbestellung INFOMAIL
by e-mail
423,00 €
plus VAT. and shipping


9359-1
PG-USB-cable 3m for Siemens S5 Controller

for PLC's + LED + metal case
Quickbestellung INFOMAIL
by e-mail
145,00 €
plus VAT. and shipping


9350-9-DIAG
DiagConn 90° Highend-connector

for PROFIBUS with diagnosis function country of origin: Germany not preferential
Quickbestellung INFOMAIL
by e-mail
54,00 €
plus VAT. and shipping


9359-LAN
S5-LAN++

Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
Quickbestellung INFOMAIL
by e-mail
452,00 €
plus VAT. and shipping


9391.1
24V DC power-supply unit 625mA

Primary 110V - 240 VAC Euro+USA-plug
Quickbestellung INFOMAIL
by e-mail
59,00 €
plus VAT. and shipping


9352.3
USB-cable plug/plug type A-B-Mini 3m

USB 1.1 / 2.0 up to 480 MBit
Quickbestellung INFOMAIL
by e-mail
25,00 €