Data-backup S7-PLC PN-port on SD-card
S7 PLC data Hardware-independent safe/restore directly to/from the SD-Card, universally with PLC-Trigger!
single license
Product Overview:
SPS data backup without installation of additional software on each SD-CARD and every FTP server.Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.
Highlights:
- Triggering directly out of the S7 controler , thus no time lag and delays due to external circuits or regulator.
- No change at your Simatic S7 controller.
- Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
- Bidirectional Backup & Playback!
more...
variants:
ARTNR: 9372-PC
Win-TELE-PROF S7 Ground package TP-II
511,00 € plus VAT. and shipping
ARTNR: 9372-PC
Win-TELE-PROF S7 Ground package TP-II
EAN number: | 4260363243407 | |
HS-code: | 85234990 |
Remote maintenance
TELE LINK NETWORK
|
||||||||
secured modem-protocol |
✓
|
✓
|
✓
|
|||||
additional software needed |
Siemens TS -Software
|
Siemens TS -Software
|
VPN-Client
|
VPN-Client
|
||||
Providing WinTELEPROF-software |
✓
|
✓
|
✓
|
|||||
modem |
analogue/ISDN
|
analogue
|
opt. via PCMCIA
|
analogue/GSM
|
analogue/ISDN/GSM
|
internet-connection
|
internet-connection
|
internet-connection
|
modem for world wide use |
✓
|
✓
|
✓
|
✓
|
✓
|
|||
interfaces | ||||||||
MPI/Profibus |
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
||||
RS232 |
2x
|
2x
|
2x
|
1x
|
1x
|
|||
TTY |
2x
|
2x
|
2x
|
1x
|
||||
PCMCIA |
2x (optionally)
|
1x
|
1x
|
|||||
Ethernet |
10/100BaseTx
|
1x
|
1x
|
5x
|
||||
USB |
2x
|
1x
|
||||||
LCD-display |
✓
|
✓
|
✓
|
✓
|
instead 10 LEDs
|
instead status-LED
|
instead webserver
|
instead webserver
|
supported PLC-protocols * | ||||||||
S7 |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
||
S5 |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
||||
Pilz PSS |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
Allen-Bradley |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
AEG |
✓ (optional)
|
✓ (optional)
|
||||||
Bosch |
✓ (optional)
|
✓ (optional)
|
||||||
Telemecanique |
✓ (optional)
|
✓ (optional)
|
||||||
GE-Fanuc |
✓ (optional)
|
✓ (optional)
|
||||||
Klöckner-Moeller |
✓ (optional)
|
✓ (optional)
|
||||||
Mitsubishi |
✓ (optional)
|
✓ (optional)
|
||||||
SMS-sending/Pager(S5/S7) |
✓
|
✓
|
✓
|
✓ (no pager)
|
only for analogue / ISDN
|
|||
HMI-messaging module(S5/S7) |
✓
|
✓
|
||||||
SMS-receive with GSM |
✓
|
|||||||
DTMF with analogue |
✓
|
|||||||
e-mail-dispatch |
✓
|
✓
|
✓
|
|||||
FAX-dispatch(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
only for analogue / ISDN
|
||||
PLC-data coupling(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
✓
|
|||
ASCII-transfer from S5/S7 |
✓
|
✓ (optional)
|
✓ (optional)
|
only with ASCII-LAN
|
||||
internet-coupling |
✓
|
|||||||
Usage as dial-up-router |
✓
|
✓
|
||||||
power supply |
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
dimensions w x h x d (in mm) |
High: 67 x 280 x 170
FLAT: 300 x 175 x 70 |
300 x 175 x 66
|
235 x 162 x 37
|
90 x 162 x 54
|
40 x 125 x 115
|
42 x 15 x 65
|
65 x 43 x 17
|
154 x 92 x 28
|
* other PLC types on request |
Product Overview:
SPS data backup without installation of additional software on each SD-CARD and every FTP server.Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.
Highlights:
- Triggering directly out of the S7 controler , thus no time lag and delays due to external circuits or regulator.
- No change at your Simatic S7 controller.
- Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
- Bidirectional Backup & Playback!
! DOUBLE FUNCTIONS for PLC experts!
- ALARM_MESSAGE DISPATCH INTEGRATED
- Freely selectable fault annunciator integrated, not only in case of faulty recording, no, a directly operation monitor for your production plant .
- Resets any error messages send by mail to any number of recipients.
- As a result, no plant supervisor escapes a malfunction!
- Avoid high costs caused by machine downtime!
- All functions of the EtherSens-Basic fully usable!
Application areas:
- Save data on your SD-Card or FTP data base, like production data and all relevant system parameters.- Use a simple SD-Card or a FTP server as data backup server , no extra software necessary.
- Backups before System conversions / changes !
- Save freely selectable DB contents and restore them!
- Link S7-Siemens PLC to any TCP/IP devices and get access to the process data directly.
- Schedule-relevant data, e.g. after finished palletizing PLC trigger controlled storing.
Configuration:
The configuration takes place directly into the integrated web server .Thanks to the designed flash memory, data can not be lost, which means a device can be easily tested at the office and then sent to the construction site__.
Even in the event of power failure or other supply disruptions there is no danger to the data.
After configuration no additional PC is required **. The installation is self-explanatory and can be carried out on-site by untrained personnel.
WinTELEPROF-software = software-PG-TELE
Your’re using the devices of the Tele-Network-family and don’t want to have a device standing on the table? No problem. Install the WinTELEPROF-software on your PC and after link
connection access to your Step5/7-programming software (also Siemens) via a virtual Com-Port.
At Step5 the Step5-software is going to be patched, then working with the virtual Com-Port will be also possible.
At Step5 the Step5-software is going to be patched, then working with the virtual Com-Port will be also possible.
All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.
511,00 €
plus VAT. and shipping
plus VAT. and shipping
168,00 €
plus VAT. and shipping
plus VAT. and shipping
168,00 €
plus VAT. and shipping
plus VAT. and shipping
168,00 €
plus VAT. and shipping
plus VAT. and shipping
1533,00 €
plus VAT. and shipping
plus VAT. and shipping
1533,00 €
plus VAT. and shipping
plus VAT. and shipping
1088,00 €
plus VAT. and shipping
plus VAT. and shipping
1088,00 €
plus VAT. and shipping
plus VAT. and shipping
119,00 €
plus VAT. and shipping
plus VAT. and shipping
1088,00 €
plus VAT. and shipping
plus VAT. and shipping
1088,00 €
plus VAT. and shipping
plus VAT. and shipping
119,00 €
plus VAT. and shipping
plus VAT. and shipping
119,00 €
plus VAT. and shipping
plus VAT. and shipping
2044,00 €
plus VAT. and shipping
plus VAT. and shipping
511,00 €
plus VAT. and shipping
plus VAT. and shipping
1533,00 €
plus VAT. and shipping
plus VAT. and shipping
511,00 €
plus VAT. and shipping
plus VAT. and shipping
168,00 €
plus VAT. and shipping
plus VAT. and shipping
357,00 €
plus VAT. and shipping
plus VAT. and shipping
119,00 €
plus VAT. and shipping
plus VAT. and shipping
357,00 €
plus VAT. and shipping
plus VAT. and shipping
357,00 €
plus VAT. and shipping
plus VAT. and shipping
357,00 €
plus VAT. and shipping
plus VAT. and shipping
511,00 €
plus VAT. and shipping
plus VAT. and shipping
Analogue-telefone
TELE-Manager
configuration / update of TELE-Network devices from PC (Windows-Software)
configuration / update of TELE-Network devices from PC (Windows-Software)
All prices plus costs of delivery, shipping insurance and VAT.