Data-backup S5-PLC on SD-card + dig.IO
S5 PLC data Hardware-independent secure/restore directly to/from a SD-CARD use PLC & additional IO trigger!
Analysis/diagnosis/monitoring of
ProfiNet-systems
Product Overview:
SPS data backup without installation of additional software on each SD-CARD every FTP server.Machine data is simply and reliably deducted from Siemens S5 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.
Highlights:
- If required can be triggered via the IO level directly without PLC changes backup / restore!
- Triggering also out of the S5 control , thus no time lag and delays due to external circuits or regulator.
- No change at your Simatic S5 controller.
- Even with occupied S5-PG interface thanks to PG-MUX-II no obstacle!
more...
ARTNR: 9354-TISCH
ProfiNet - WATCHDOG -desktop case
EAN number: | 4260363249003 | |
HS-code: | 85176200 | |
Weight: | 0.3 kg |
Product Overview:
SPS data backup without installation of additional software on each SD-CARD every FTP server.Machine data is simply and reliably deducted from Siemens S5 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.
Highlights:
- If required can be triggered via the IO level directly without PLC changes backup / restore!
- Triggering also out of the S5 control , thus no time lag and delays due to external circuits or regulator.
- No change at your Simatic S5 controller.
- Even with occupied S5-PG interface thanks to PG-MUX-II no obstacle!
- Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
- Bidirectional Backup & Playback!
! DOUBLE FUNCTIONS for PLC experts!
- S5 PROGRAMMING & EXTERNAL ACCESS:
- programming and visualization possible, parallel to your Siemens S5!
- You can use the, in the product included, S5-LAN and all the functionality of the module!
- Direct access from all S7-TCP-IP devices down to the I/O level of the S5 machine!
ALARM_MESSAGE DISPATCH INTEGRATED
- Freely selectable fault annunciator integrated, not only in case of faulty recording, no, a directly operation monitor for your production plant .
- Resets any error messages send by mail to any number of recipients.
- As a result, no plant supervisor escapes a malfunction!
- Avoid high costs caused by machine downtime!
- All functions of the EtherSens Control 24V Digital-/Relais-IO fully usable!
Application areas:
- Save data on your FTP data base , like production data and all relevant system parameters.- Use a simple SD-CARD or a FTP server as data backup server , no extra software necessary.
- Backups before System conversions / changes !
- Save freely selectable DB contents and restore them!
- Link S5-Siemens PLC to S7-TCP devices and get access to the process data directly.
- Schedule-relevant data, e.g. after finished palletizing IO- andPLC trigger controlled storing.
Configuration:
The configuration takes place directly into the integrated web server .Thanks to the designed flash memory, data can not be lost, which means a device can be easily tested at the office and then sent to the construction site__.
Even in the event of power failure or other supply disruptions there is no danger to the data.
After configuration no additional PC is required . The installation is self-explanatory and can be carried out on-site by untrained personnel.
Detection and logging of unauthorized access in the defined Profinet
Attempted break-ins and access to the network are recognized immediately and e.g. reported by email
Logging of all accesses in the network for historical processing
Possible data-storage USB-stick or FTP-server via USB-network-stick.
Identify devices that are likely to fail in the near future.
Detect defective devices that no longer respond to PN protocols.
Defective devices are reported by email and logged.
No long troubleshooting thanks to exact station information.
Exact analysis of your Profinet members.
Addresses, configurations and other data can be recorded directly.
See immediately possible conflicts due to the configuration.
Detection and logging of unauthorized access in the defined Profinet
Attempted break-ins and access to the network are recognized immediately and e.g. reported by email
Logging of all accesses in the network for historical processing
Possible data-storage USB-stick or FTP-server via USB-network-stick.
Recognize cable breakage, contact problems and line faults.
Retransmissions and failures are logged and reported.
Early acting before total failure of the participant.
Recognize cable breakage, contact problems and line faults.
Retransmissions and failures are logged and reported.
Early acting before total failure of the participant.
Identify impending failures in your Profinet.
Creeping aging will be displayed to you very detailed.
The Profinet-Watchdog give you the change to react before something happens.
Identify impending failures in your Profinet.
Creeping aging will be displayed to you very detailed.
The Profinet-Watchdog give you the change to react before something happens.
Detect intrusions and anomalies on your ProfiNet.
Early detection of malfunction and failures and malfunctions.
Easy installation, plug and play double socket.
You may not use WIFI in your environment?
Connect the USB-ETHERNET-adapter to the ProfiNet-WATCHDOG's USB-port and create another Ethernet-socket.
Connect your PC directly with LAN-cable to the ProfiNet WATCHDOG.
Supply voltage: |
24V DC +/- 20% USB (from PC/power-pack) |
Power consumption: | 2 watt |
Display: |
WEB-Browser status LEDs |
Handling/Configuration: | WEB-Browser |
Interfaces: |
2 x 10/100BaseTX RJ45-ethernet-plug Antenna-connector SMA(f) (2.4 GHz IEEE 802.11b/g) |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case V0 |
Dimensions: | 115 x 95 x 30 mm |
Scope of delivery: |
ProfiNet-WATCHDOG (table-case) WIFI-stub-antenna small power plug |
accessories:
plus VAT. and shipping
Magnetic base antenna for indoor use
for ALF, ALF-UA- S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
TINA - mobile intelligent network-analyser
Simple Network-troubleshooting +++ Webserver operation/control +++ Networkanalysis 10/100 MBit without effort +++ To PC with 2,4 GHz +++ Detection network violations +++ Resolve IP-address conflicts +++ PROFINET monitori
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping