EtherSens Basic
PLC fault message dispatch +++ PLC data logging/saving +++ implement control tasks +++ Universal solution per task +++ Web page parameterization +++ EtherSens Basic
Operating as a client or access-point
Configuration via web-server
Supply: 24V DC
Features:
- Sends alarm-messages controlled by the PLC
- Receiver in the PLC deposited, so ONLINE replaceable
- Messages in the PLC deposited, so ONLINE replaceable
more...
ARTNR: 9201
EtherSens Basic
EAN number: | 4260363244282 | |
HS-code: | 85423190 | |
Weight: | 0.3 kg |
Features:
- Sends alarm-messages controlled by the PLC
- Receiver in the PLC deposited, so ONLINE replaceable
- Messages in the PLC deposited, so ONLINE replaceable
- Communication with a controller via optional IO-modules, LTE or via network S7-TCPIP RFC1006
- S7-PLC over S7-LAN-module
- S5-PLC over S5-LAN++-module
- Solve control-tasks via integrated logic-module
- Implementation of different protocols, for e.g. L1-bus-communication via RFC1006, Modbus
- Coupling of multiple devices to a network
- Coupling with WinCC and access to process values
Application-examples (only german language):
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PN-port to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on SD card
Via digital input triggered DB-backup/-restore without additional PC via PN-port to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via PN-port to USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PN-port to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on SD-card
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to USB-stick
Send directly from your PLC news, statuses, alarms as SMS or email.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2 watt |
Display: |
WEB-Browser 1 status LED bicolor |
Handling/Configuration: | WEB-Browser |
Interfaces: |
Slot for microSD Antenna-connector SMA(f) (2.4 GHz IEEE 802.11b/g) 10/100BaseTX RJ45-ethernet-plug Button for factory settings |
Overvoltage category: | CAT IV |
Insulation value network <=> mains voltage: |
1,5 KV |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case V0 |
Dimensions: | 100 x 112 x 45 mm |
Scope of delivery: |
EtherSens Basic WIFI-stub-antenna |
extensions:
Extension Analog-IO V1.0
Extension-board for EtherSens-devices 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Extension with ext. galv. separated I2C 5V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 5V Power consumption: 2W
plus VAT. and shipping
Extension LTE-modem
LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
plus VAT. and shipping
Extension Energy-IO
Extension-board for EtherSens-devices Energy-analysis (EN 50470-1 EN 50470-3) L1, L2, L3, N realtime analysis Up to 8000 measurements / second Hz / cos phi / power-factor Energy consumption kWh For Rogwski-coils up to 0,5V
plus VAT. and shipping
U-I-box for EtherSens
max. 1000V DC / 40A 24V DC supply 20cm power-cable 4mm2 with Amphenol-plug I2C-connection 1m
plus VAT. and shipping
Sun-light-sensor for EtherSens
max. 220k Lux (switchable ranges) 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 312 for EtherSens
Measuring range: ±1.5g / ±3g / ±6g / ±12g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 313 for EtherSens
Measuring range: ±0.5g / ±1g / ±2g / ±4g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Temp./humidity/air-pressure for EtherSens
Measuring range: Temperature: -40 ...+85°C Humidity: 0...100% relative Feuchte Pressure: 300...1100 hPa 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Segment-display for EtherSens
4 Digit 14 segment-display WHITE 0,56" high in wall-mounting case 5V DC supply (from I2C-interfaceport) I2C-connection
plus VAT. and shipping
Extension with ext. galv. separated I2C 3.3V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W
plus VAT. and shipping
Extension RS485-IO
Extensionboard for EtherSens-devices V1.0 for RS485 Power consumption: 2W
plus VAT. and shipping
Extension TTY-IO
Extensionboard for EtherSens-devices V1.0 for TTY (incl. 2x current-sources) Power consumption: 2W
plus VAT. and shipping
Extension Digital-IO
Extension-board for EtherSens-devices 12 x digital IN or OUT 24VDC 400mA free config with software Power consumption: 4W
plus VAT. and shipping
Extension 24V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 24V DC 4 x relay-OUT 230VAC/16A Power consumption: 4W
plus VAT. and shipping
Extension 230V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 230V AC 4 x relay-OUT 230VAC/16A Power consumption: 2,5W
plus VAT. and shipping
Power-supply-rack-unit 230V
Input voltage: 100 - 240VAC 50-60Hz Output voltage: 24V DC Power: 4W
plus VAT. and shipping
Extension Analog-IO V1.1
Extension-board for EtherSens-devices 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Extension RS422-IO
Extensionboard for EtherSens-devices V1.0 for RS422 (4-wire) Power consumption: 2W
plus VAT. and shipping
Extension RS232-IO
Extensionboard for EtherSens-devices V1.0 for RS232 (RxD, TxD) Power consumption: 2W
plus VAT. and shipping
Extension USB-port
USB-port for EtherSens-devices (data storage) Extension for: - DB-backup/restoure-function - CSV-recording Maximum current: 200mA for 5V DC
plus VAT. and shipping
accessories:
plus VAT. and shipping
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
EtherSens
Collect energy data +++ Log energy data +++ PLC fault message dispatch +++ PLC data logging/saving +++ Implement control tasks +++ Configuration via webinterface
Capture Dig/Analog-IO +++ Log Dig/Analog-IO +++ PLC fault message-dispatch +++ PLC-data logging/saving +++ implement control-tasks +++ Datalogger with web-server +++ Digital/analogue onboard-IO
Capture of gas-values +++ Monitor of gas-values +++ PLC-fault messaging +++ PLC-data logging/saving +++ Convert control tasks
load studies +++ energy checks +++ collect energy data +++ Log energy data +++ PLC fault message dispatch +++ PLC-data logging/saving +++ implement control-tasks +++ EN50470-1 / EN50470-3
Error messaging
Long distance report- and information systems in 2G-net
Long distance report- and information systems in 3G-net
The complete and flexible solution for monitoring, controlling and analyzing industrial processes
The complete and flexible solution for monitoring, controlling and analyzing industrial processes
plus VAT. and shipping
plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping
Extension LTE-modem
LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
plus VAT. and shipping
Extension with ext. galv. separated I2C 3.3V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W
plus VAT. and shipping