EtherSens Oxygen
Capture of gas-values +++ Monitor of gas-values +++ PLC-fault messaging +++ PLC-data logging/saving +++ Convert control tasks
OxygenServiceController 100% - 10E-24%
New: Ethersens ProSuite with optional touch-graphic-display and IO-busFeatures:
- Measuring range of O2 from 100% - 10E-24% (depending on the device)
- Sends alarm-messages controlled by the PLC
- Receiver in the PLC deposited, so ONLINE replaceable
- Messages in the PLC deposited, so ONLINE replaceable
more...
ARTNR: 9205
EtherSens Oxygen zirconium-probe
EAN number: | 4260363244411 | |
HS-code: | 85423190 | |
Weight: | 0.3 kg |
Features:
- Measuring range of O2 from 100% - 10E-24% (depending on the device)
- Sends alarm-messages controlled by the PLC
- Receiver in the PLC deposited, so ONLINE replaceable
- Messages in the PLC deposited, so ONLINE replaceable
- Communication with a controller via optional IO-modules, LTE or via network S7-TCPIP RFC1006
- S7-PLC over S7-LAN-module
- S5-PLC over S5-LAN++-module
- Solve control-tasks via integrated logic-module
- Implementation of different protocols, for e.g. L1-bus-communication via RFC1006, Modbus
- Coupling of multiple devices to a network
- Coupling with WinCC and access to process values
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PN-port to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on SD card
Via digital input triggered DB-backup/-restore without additional PC via PN-port to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via PN-port to USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PN-port to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on SD-card
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to USB-stick
Capture with the Ethersens-device not only your process-values, you would be able to do control-tasks with the device.
Supply voltage: | 100 - 240V AC, 50 - 60 Hz |
Display: |
WEB-Browser 1 status LED bicolor |
Handling/Configuration: | WEB-Browser |
Principle of measurement: |
Art.nr. 9205: zirconium-probe Art.nr. 9206: plum-O2-cell |
Measuring range: |
Art.nr. 9205: 100% - 10E-24% Art.nr. 9206: 100% - 0% |
Interfaces: |
Slot for microSD Antenna-connector SMA(f) (2.4 GHz IEEE 802.11b/g) 10/100BaseTX RJ45-ethernet-plug Button for factory settings |
Overvoltage category: | CAT IV |
Insulation value network <=> mains voltage: |
1,5 KV |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case V0 |
Dimensions: | 100 x 112 x 45 mm |
Scope of delivery: |
EtherSens Oxygen WIFI-stub-antenna |
accessories:
plus VAT. and shipping
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
extensions:
Extension Analog-IO V1.0
Extension-board for EtherSens-devices 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Segment-display for EtherSens
4 Digit 14 segment-display WHITE 0,56" high in wall-mounting case 5V DC supply (from I2C-interfaceport) I2C-connection
plus VAT. and shipping
Gyro-Sensor 313 for EtherSens
Measuring range: ±0.5g / ±1g / ±2g / ±4g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 312 for EtherSens
Measuring range: ±1.5g / ±3g / ±6g / ±12g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Temp./humidity/air-pressure for EtherSens
Measuring range: Temperature: -40 ...+85°C Humidity: 0...100% relative Feuchte Pressure: 300...1100 hPa 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Sun-light-sensor for EtherSens
max. 220k Lux (switchable ranges) 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
U-I-box for EtherSens
max. 1000V DC / 40A 24V DC supply 20cm power-cable 4mm2 with Amphenol-plug I2C-connection 1m
plus VAT. and shipping
Extension LTE-modem
LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
plus VAT. and shipping
Extension with ext. galv. separated I2C 5V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 5V Power consumption: 2W
plus VAT. and shipping
Extension with ext. galv. separated I2C 3.3V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W
plus VAT. and shipping
Extension RS485-IO
Extensionboard for EtherSens-devices V1.0 for RS485 Power consumption: 2W
plus VAT. and shipping
Extension TTY-IO
Extensionboard for EtherSens-devices V1.0 for TTY (incl. 2x current-sources) Power consumption: 2W
plus VAT. and shipping
Extension RS232-IO
Extensionboard for EtherSens-devices V1.0 for RS232 (RxD, TxD) Power consumption: 2W
plus VAT. and shipping
Extension RS422-IO
Extensionboard for EtherSens-devices V1.0 for RS422 (4-wire) Power consumption: 2W
plus VAT. and shipping
Extension Analog-IO V1.1
Extension-board for EtherSens-devices 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Extension 230V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 230V AC 4 x relay-OUT 230VAC/16A Power consumption: 2,5W
plus VAT. and shipping
Extension 24V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 24V DC 4 x relay-OUT 230VAC/16A Power consumption: 4W
plus VAT. and shipping
Extension Digital-IO
Extension-board for EtherSens-devices 12 x digital IN or OUT 24VDC 400mA free config with software Power consumption: 4W
plus VAT. and shipping
Extension USB-port
USB-port for EtherSens-devices (data storage) Extension for: - DB-backup/restoure-function - CSV-recording Maximum current: 200mA for 5V DC
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
EtherSens
Collect energy data +++ Log energy data +++ PLC fault message dispatch +++ PLC data logging/saving +++ Implement control tasks +++ Configuration via webinterface
Capture Dig/Analog-IO +++ Log Dig/Analog-IO +++ PLC fault message-dispatch +++ PLC-data logging/saving +++ implement control-tasks +++ Datalogger with web-server +++ Digital/analogue onboard-IO
PLC fault message dispatch +++ PLC data logging/saving +++ implement control tasks +++ Universal solution per task +++ Web page parameterization +++ EtherSens Basic
load studies +++ energy checks +++ collect energy data +++ Log energy data +++ PLC fault message dispatch +++ PLC-data logging/saving +++ implement control-tasks +++ EN50470-1 / EN50470-3
The complete and flexible solution for monitoring, controlling and analyzing industrial processes
The complete and flexible solution for monitoring, controlling and analyzing industrial processes