MONI mobile netanalyser EN 50470-1 / EN 50470-3
load studies +++ energy checks +++ collect energy data +++ Log energy data +++ PLC fault message dispatch +++ PLC-data logging/saving +++ implement control-tasks +++ EN50470-1 / EN50470-3
L1, L2, L3, N realtime analyses
8000 measurements / second
Voltage 100-500VAC
Current 0,1-5000A Push-Pull
Hz / cos phi / power-factor
Active, reactive and apparent energy-
consumption in kWh
Supply 100-240V 50-60Hz/24VDC/USB
Operation / configuration web-browser over
LAN / Wifi
Data-storage microSD/FTP-Server
For Rogwski-coils up to 0,5V
- Determining energy-efficiency
- Energy-analysis (EN 50470-1 EN 50470-3)
- L1, L2, L3 and N realtime analysis
- up to 8000 measurements / second
- Voltage 100-500V AC
more...
ARTNR: 9210
MONI portable netanalyser EN 50470-1 / EN 50470-3
EAN number: | 4260363244497 | |
HS-code: | 85423190 | |
Weight: | 0.3 kg |
- Determining energy-efficiency
- Energy-analysis (EN 50470-1 EN 50470-3)
- L1, L2, L3 and N realtime analysis
- up to 8000 measurements / second
- Voltage 100-500V AC
- Current 0,1-5000A (Push-Pull-connector)
- frequency Hz / cos phi / power-factor
- energy-measurement kW/h
- Operation / configuration web-browser over LAN / Wifi
- Supply:
100-240V 50-60Hz (from L1) / 24VDC (over detachable connector) / USB (from PC/power-pack) - Data-transfer via TCP/IP in a DB in S7-PLC
- WIFI-modes: Access-Point (open an own net) and Client (connects to an existing net)
- Data-storage microSD/FTP-Server
- For Rogowski-spool
- For folding cores
Example instruments-mask: | ||
Example History: |
||
Observe the collected energy-information (voltages, power, currents, phase-angles, ...) on the integrated web-server of MONI "cable-less" with your mobile-phone or tablet. Change the parameterization of MONI, operate and control
MONI easily via the web interface.
Of course you can also operate wired, where you put MONI in your network. Parallel operation of LAN and Wifi is also possible.
Supply voltage: |
100 - 240V AC, 50 - 60 Hz 24V DC +/- 20% USB (from PC/power-pack) |
Power consumption: | 6 watt |
Measurement: |
|
Display: |
WEB-Browser 1 status LED bicolor |
Handling/Configuration: | WEB-Browser |
Interfaces: |
4 x voltage-input (L1, L2, L3, N) 4 x sensor-input (B+W-terminal ever phase + N) Slot for microSD Antenna-connector SMA(f) (2.4 GHz IEEE 802.11b/g) 10/100BaseTX RJ45-ethernet-plug Button for factory settings |
Overvoltage category: | CAT IV |
Insulation value network <=> mains voltage: |
1,5 KV |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case V0 |
Dimensions: | 115 x 95 x 30 mm |
Scope of delivery: |
MONI WIFI-stub-antenna |
sensors:
Rogowski-coil 5000A, 55mm with push-pull-connector
Cable hole: 55mm Cable length: 1,5m Shutter: click cap With push-pull-connector Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 35mm with push-pull-connector
Cable hole: 35mm Cable length: 1,5m Shutter: click cap With push-pull-connector Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 470mm, twist-lock with PP Obsolete
Cable hole: 470mm Cable length: 2,5m Shutter: twist-lock With push-pull-connector Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 80mm with push-pull-connector
Cable hole: 80mm Cable length: 1,5m Shutter: click cap With push-pull-connector Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 35mm, twist-lock with PP Obsolete
Cable hole: 35mm Cable length: 2,5m Shutter: twist-lock With push-pull-connector Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 80mm, twist-lock with PP
Cable hole: 80mm Cable length: 2,5m Shutter: twist-lock With push-pull-connector Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 160mm, twist-lock with PP Obsolete
Cable hole: 160mm Cable length: 2,5m Shutter: twist-lock With push-pull-connector Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
accessories:
plus VAT. and shipping
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
EtherSens
Collect energy data +++ Log energy data +++ PLC fault message dispatch +++ PLC data logging/saving +++ Implement control tasks +++ Configuration via webinterface
Capture Dig/Analog-IO +++ Log Dig/Analog-IO +++ PLC fault message-dispatch +++ PLC-data logging/saving +++ implement control-tasks +++ Datalogger with web-server +++ Digital/analogue onboard-IO
PLC fault message dispatch +++ PLC data logging/saving +++ implement control tasks +++ Universal solution per task +++ Web page parameterization +++ EtherSens Basic
Capture of gas-values +++ Monitor of gas-values +++ PLC-fault messaging +++ PLC-data logging/saving +++ Convert control tasks
The complete and flexible solution for monitoring, controlling and analyzing industrial processes
The complete and flexible solution for monitoring, controlling and analyzing industrial processes
plus VAT. and shipping
Rogowski-coil 5000A, 55mm with push-pull-connector
Cable hole: 55mm Cable length: 1,5m Shutter: click cap With push-pull-connector Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 35mm with push-pull-connector
Cable hole: 35mm Cable length: 1,5m Shutter: click cap With push-pull-connector Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Net-connection-set
Cable-set consisting of: 3x black 1x blue 1x green Safety test lead 1000 V / CAT II Stackable connectors Ø 4 mm Length 2 m
plus VAT. and shipping
plus VAT. and shipping