MPI/PPI
S7-Interface cable for PPI, MPI, TS, HMI <=> RS232 applications
with LCD-display
- Automatic protocol- and baud rate detection (depends on the used product from 9K6 to 187K5)
- Connects only to the bus when it is requested by PG
- Firmwareupdate via internet for free
- PPI - adapter for S7 - 200
- MPI/Profibus - adapter for S7 - 300 + 400
more...
ARTNR: 9350
MPI+PPI+HMI+TS - Interfacecable 3m
Obsolete
EAN number: | 4260363241304 | |
HS-code: | 85444290 | |
Weight: | 0.5 kg |
Alternativen
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
plus VAT. and shipping
Programming adapter S7
PPI-Bus | |||||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||||
USB | |||||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||||
LAN | |||||||||
10/100BaseTx |
x(7)
|
x
|
x
|
x
|
x
|
||||
WIFI | |||||||||
2.4 GHz |
x
|
||||||||
TeleService operation | |||||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||||
baud rates at TS-operation directly at the PC | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||||
baud rates at TS-operation directly with a modem | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x
|
x
|
|||||||
115.2 KBit/s |
x
|
x
|
|||||||
HMI | |||||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||||
PLCVCOM |
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
RFC1006 |
8
|
8
|
32
|
32
|
32
|
||||
AG connections (maximum) | |||||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||||
integrated PLC-firewall |
|
|
x
|
x
|
x
|
||||
display diagnostic-buffer in the webbrowser |
|
|
x
|
x
|
x
|
||||
webserver for configuration |
x
|
x
|
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
x
|
x
|
||||
galvanic separation | |||||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
1,5KV
|
1,5KV
|
mounting | |||||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||||
upgrading with | |||||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||||
supports | |||||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win11 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1 (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3 (3) only serial communication (4) Siemens Step7 V5.2 and higher dont run with this operationing system (5) USB-communication is only possible with the special driver for Win NT (6) USB 2.0 is backward compatible to 1.1 (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation (8) only in combination with the MPI-Speed-driver („continously-active“) (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional) (11) only in the mode: MultiMaster-Mode (12) up to a maximum baud rate of 187.5 KBit/s (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port. (14) with the use of the TS-adapter / item number: 9350.TS (15) Update directly with PC and TIC-driver (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens (19) only at PPI-communication possible (20) Only with TIC-driver (21) with integrated webserver possible (22) No support of Siemens Step7-software possible (23) Only with USB and with TIC-driver |
- Automatic protocol- and baud rate detection (depends on the used product from 9K6 to 187K5)
- Connects only to the bus when it is requested by PG
- Firmwareupdate via internet for free
- PPI - adapter for S7 - 200
- MPI/Profibus - adapter for S7 - 300 + 400
- CE/EMC compliant construction
- All intelligent MPI-interface-products including a free OPC-server license "OPC-Manager lite" [limited to 100 items]
- All products, including the examples and demo-version of communication driver as download on the product-site
- Integrated display for output of diagnostic informations
- Applicable as TS/HMI adapter
- Double-sided connected cable
The MPI/PPI-cable Art.No. 9350 connects the programming-device or the PC via the serial interface (COM-connection) with the MPI-interface of an S7-300/400 or with the PPI-interface of an S7-200.
The cable automatically detects when plugging in the PLC which PLC-type is connected. The baud-rate (9600 - 115200 bps) of the PC is also detected automatically. The scope of delivery includes the
MPI-Speed-driver for the Step7-software from Siemens. This allows the baud-rate on the PC-side to be set to 115.2 KBaud. Otherwise use the standard Siemens baud-rate (maximum 38400). The power-supply
gets the MPI/PPI-cable from the PLC and thus requires no external supply. All voltages are galvanically isolated from each other (24V input to the bus and to the internal electronics).
To bridge long distances to a PLC, the optional MPI-NETZ-adapter can be used to feed the 24V.
Other supported applications:
- HMI (Human Machine Interface)
- TS (Tele Service)
The HMI-variant enables the connection of a control-panel (which does not have an internal MPI-interface, but the HMI-protocol and an RS232-interface) to an S7-300/400. The cable is plugged in between the control-panel and the PLC. The HMI-protocol must be part of the control-panel.
TS:
The TS-variant enables the connection of a modem so that a connection to an S7-300/400 can be established on the PC with the aid of a second modem. The cable is plugged in between the modem and the PLC. In the TS-variant, the PC/MPI-adapter is compatible with the Siemens TS-adapter.
Connecting the adapter
The cable is plugged with the short side into the MPI- or PPI-interface of the PLC. The MPI/PPI-cable is supplied from the PLC and requires no external supply. The cable always needs a PLC because it needs its 24V (or optionally the MPI-NETZ-adapter). The longer cable side is plugged into the PG or into the PC at its COM-port. As soon as the adapter is energized, it will display its software version and begin the functional test of its internal components. It then checks whether the cable is connected to a controller with MPI or PPI bus and adapts to the respective transmission variant. The display window of the MPI/PPI-cable contains all relevant data. In the case of an MPI-connection, the cable automatically finds out and sets the baud-rate parameters for the programming device (PC) during a PG access.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2 watt |
Display: | double lined LCD-display |
Handling/Configuration: | Kabelmanager-Software |
Interfaces: |
to the PLC:
PPI/MPI-bus interface: 9,6 KBd - 187,5 KBd
to the PD/PC:
RS232: 9,6 KBd - 115,2 KBd |
Galvanic separation: | 1000V PPI/MPI-bus to the PC |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 146 x 41 x 29 mm |
Scope of delivery: | MPI/PPI-cable |
accessories:
plus VAT. and shipping
plus VAT. and shipping
DIN-rail-holder for MPI/PPI
quick and easy assembling on the cap rail
Wall-mounting
for MPI/PPI + MPI-II + MPI-USB
plus VAT. and shipping
MPI-PC104-card 2 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
MPI-PC104-card 1 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
plus VAT. and shipping
plus VAT. and shipping
Power-adapter for MPI-cable
without power-supply unit
Power-adapter for MPI-cable
with power-supply unit 100-240VAC
plus VAT. and shipping
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
RS232
Universal S7interface-cable +++ RS232/USB to PPI/MPI/PROFIBUS +++ For HMI-USB applications +++ Bus-status on display
Connects the S5-PLC with a S7-PLC
plus VAT. and shipping
DiagConn 90° Highend-connector
for PROFIBUS with diagnosis function country of origin: Germany not preferential
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller Obsolete
Successor: S7-LAN++ connector for Siemens S7 Controller (Art.No: 9352-LANCON++)
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping