ALF-UA-WLAN/WIFI-Sets
Service-suitcase for couppling to a PLC over LAN/WLAN incl. all accessories
Service-case for coupling to a S7-PLC
over WLAN
- Practical and stable plastic case with two airtight closures
- Includes all what is needed for S7-communication
- Connects comfortable PC with PLC via LAN or WLAN
- Also for S7-1200 usable
- Scobe of delivery:
more...
variants:
ARTNR: 9352-ALF-UA-WSET
ALF-UA-WLAN-SET for S7-PLC
688,00 € plus VAT. and shipping
ARTNR: 9352-ALF-UA-WSET
ALF-UA-WLAN-SET for S7-PLC
EAN number: | 4260363247900 | |
HS-code: | 85444290 | |
Weight: | 0.5 kg |
WLAN/WIFI-SETs
Suitcase |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
ALF (9352-ALF) |
✓
|
✓
|
✓
|
|||||||||||||||
ALF-UA (9352-ALF-UA) |
✓
|
✓
|
✓
|
|||||||||||||||
S5-LAN++ (9359-LAN) |
✓
|
✓
|
✓
|
✓
|
||||||||||||||
S7-LAN (9352-LANCON) |
✓
|
✓
|
✓
|
✓
|
||||||||||||||
S5-BRIDGE (9359-S5-WIFI) |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
| ||||||||||
S7-BRIDGE (9352-S7-WIFI) |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
| ||||||||||
Patch-cable 3m (9636-TCPIP) |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
Cross-cable 3m (9636-CROSS) |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
Magnetic antenna (9352-ALF-ANT) |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
| ||||||||||||
AC adapter (9391.1) |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
WLAN/WIFI-SETs
Suitcase |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
ALF (9352-ALF) |
✓
|
✓
|
✓
|
|||||||||||||||
ALF-UA (9352-ALF-UA) |
✓
|
✓
|
✓
|
|||||||||||||||
S5-LAN++ (9359-LAN) |
✓
|
✓
|
✓
|
✓
|
||||||||||||||
S7-LAN (9352-LANCON) |
✓
|
✓
|
✓
|
✓
|
||||||||||||||
S5-BRIDGE (9359-S5-WIFI) |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
| ||||||||||
S7-BRIDGE (9352-S7-WIFI) |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
| ||||||||||
Patch-cable 3m (9636-TCPIP) |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
Cross-cable 3m (9636-CROSS) |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
Magnetic antenna (9352-ALF-ANT) |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
| ||||||||||||
AC adapter (9391.1) |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
Differences between ALF (art.nr.: 9352-ALF) and ALF-UA (art.nr.: 9352-ALF-UA / 9352-ALF-UA-TISCH)
ALF | ALF-UA | ALF-UA-TISCH | |
Assembly / housing | Tabletop unit | DIN-rail assembly | Tabletop unit |
Search for access. nodes Simatic-Manager/TIA | --- | Yes | Yes |
Support WPS registration | Yes | --- | --- |
Easy configuration | --- | Yes | Yes |
Restart mandatory between config changes | Yes | No, just switch | No, just switch |
Language of the web interface | only GB | D / GB switchable | D / GB switchable |
Access-Point/Client at the same time | --- | Yes | Yes |
WAN-port can be used in AP-bridge-mode | --- | Yes | Yes |
WAN-port can be used in client-bridge-mode | --- | Yes | Yes |
USB port for future expansion | --- | Yes | Yes |
Passive POE (12V) | Yes | --- | --- |
S7
PPI-Bus | |||||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||||
USB | |||||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||||
LAN | |||||||||
10/100BaseTx |
x(7)
|
x
|
x
|
x
|
x
|
||||
WIFI | |||||||||
2.4 GHz |
x
|
||||||||
TeleService operation | |||||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||||
baud rates at TS-operation directly at the PC | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||||
baud rates at TS-operation directly with a modem | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x
|
x
|
|||||||
115.2 KBit/s |
x
|
x
|
|||||||
HMI | |||||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||||
PLCVCOM |
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
RFC1006 |
8
|
8
|
32
|
32
|
32
|
||||
AG connections (maximum) | |||||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||||
integrated PLC-firewall |
|
|
x
|
x
|
x
|
||||
display diagnostic-buffer in the webbrowser |
|
|
x
|
x
|
x
|
||||
webserver for configuration |
x
|
x
|
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
x
|
x
|
||||
galvanic separation | |||||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
1,5KV
|
1,5KV
|
mounting | |||||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||||
upgrading with | |||||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||||
supports | |||||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win11 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1 (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3 (3) only serial communication (4) Siemens Step7 V5.2 and higher dont run with this operationing system (5) USB-communication is only possible with the special driver for Win NT (6) USB 2.0 is backward compatible to 1.1 (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation (8) only in combination with the MPI-Speed-driver („continously-active“) (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional) (11) only in the mode: MultiMaster-Mode (12) up to a maximum baud rate of 187.5 KBit/s (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port. (14) with the use of the TS-adapter / item number: 9350.TS (15) Update directly with PC and TIC-driver (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens (19) only at PPI-communication possible (20) Only with TIC-driver (21) with integrated webserver possible (22) No support of Siemens Step7-software possible (23) Only with USB and with TIC-driver |
S5
device type | ||||||
S5-90U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-95U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-100U |
x
|
+ext. 24V(3)
|
+ext. 24V
|
x
|
x
|
x
|
S5-115U |
at 944 + 9359-8
|
at 944 + 9359-8 + ext. 24V (4)
|
x
|
x
|
x
|
x
|
S5-135U |
at 928B + 9359-8
|
at 928B + 9359-8 +ext. 24V (6)
|
x
|
x
|
x
|
x
|
S5-155U |
x
|
x
|
x
|
x
|
x
|
x
|
S5-AG110S |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG130W/B |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG150A/K/S/U |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
CP-143 |
x
|
x
|
x
|
|||
CP-521 |
+CP521 adapter
|
+CP521 adapter(1)
|
||||
CP-523 |
+CP523 adapter
|
+CP523 adapter(1)
|
||||
CP-525 |
+9359-5(1)
|
|||||
CP-526 |
x
|
x
|
x
|
|||
CP-527 |
x
|
x
|
x
|
|||
CP-528 |
x
|
x
|
x
|
|||
CP-544 |
x (7)
|
x (7)
|
x (7)
|
|||
CP-5430 |
x
|
x
|
x
|
|||
CP-5431 |
x
|
|||||
IP-246 |
x
|
x
|
x
|
|||
IP-247 |
x
|
x
|
x
|
|||
IP-252 |
x
|
x
|
x
|
|||
IP-266 |
x
|
+9359-4(1)
|
||||
WF-470 |
+9359-5-WF470 + 9359-4(1)
|
|||||
SIN-805 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-820 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-840 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-850 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-880 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
Connection on PC |
RS232-port
|
Ethernet RJ45
|
Ethernet RJ45 / WLAN/WIFI
|
USB-port type A
|
RS232-port
|
RS232-port
|
max. prolongation: | 300m (UNI-extension) | 300m (S5-LAN-extension) +ext. 24V | 100m (PG-USB-extension) | 300m (UNI-extension) | ||
(1) ISO adapter can not be used because the required supply voltage on the PG interface of the module is not present. (2) At the CPU 6ES5 102-8MA02 Release 3 is a PG-ISO-Adapter or Netz-Adapter additional required. (3) With S5-LAN++ from HW V2.3 [2010] the "Netz-Adapter" is no more needed, this version has included current-sources. (4) With S5-LAN++ from HW V2.3 [2010] no accessories are needed, this version has included current-sources. (5) With S5-LAN++ from HW V2.3 [2010] the Sinum-Adapter 9359-6-USB is needed. (6) Only for CPU928B with PG-ISO-Adapter and ext. 24V DC, unless there is an S5-LAN++ from HW V2.3 [2010] used. (7) CP544 has bolts at the programming-interface. The products do not fit 100% on this interface. (8) With S5-BRIDGE the Sinum-Adapter 9359-6-USB is needed. |
- Practical and stable plastic case with two airtight closures
- Includes all what is needed for S7-communication
- Connects comfortable PC with PLC via LAN or WLAN
- Also for S7-1200 usable
- Scobe of delivery:
9352-ALF-UA-WSET9352-ALF-UA-WSET-S59352-ALF-UA-WSET-S5/7
Device/product ALF-UA ✓✓✓S5-LAN++ ✓✓S7-LAN ✓✓Patch-cable 3m ✓✓✓Cross-cable 3m ✓✓✓Suitcase ✓✓✓
Universally on/around machine and PLC
Communication with S5/S7-PLC (mainly), whether wired or via WIFI?
Universally armed for all requirements with the WIFI-sets, regardless of whether it is an S7-PLC, S5-PLC or a controller from another manufacturer with a LAN connection,
having everything with you, depending on the used set, is your advantage.
- S5-LAN++ or S5-BRIDGE for S5-PLC
- S7-LAN or S7-BRIDGE for S7-PLC (PPI/MPI/Profibus)
- ALF-UA as a pure converter from Ethernet to WIFI
- Patch-cable or Cross-cable in order to act also wired
This makes (on-site-) work a pleasure.
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
59,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-ALF-ANT
Magnetic base antenna for indoor use
For S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m
Magnetic base antenna for indoor use
For S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m
83,00 €
plus VAT. and shipping
plus VAT. and shipping
9350-9-CHP-24V-OUT
CheapConn Busconnector with 24V-output
Comfortable power supply for ALF, TONI, WLAN-Klemme and CONNECT-ROUTER
CheapConn Busconnector with 24V-output
Comfortable power supply for ALF, TONI, WLAN-Klemme and CONNECT-ROUTER
85,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-ALF-RICHT-ANT
Beam antenna for ALF
Beam antenna with 17dBi power gain for classic radio link connection cable optional
Beam antenna for ALF
Beam antenna with 17dBi power gain for classic radio link connection cable optional
price on request
plus VAT. and shipping
plus VAT. and shipping
9352-ALF-SEKT-ANT
Sector antenna for ALF
Sector antenna with 17dBi power gain and bundled radiation. Connection cable optional
Sector antenna for ALF
Sector antenna with 17dBi power gain and bundled radiation. Connection cable optional
price on request
plus VAT. and shipping
plus VAT. and shipping
price on request
plus VAT. and shipping
plus VAT. and shipping
9391-USB
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
95,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-ALF-ANT-WAND
Stationary antenna for wall fastening
For S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 2,5m for indoor and outdoor use incl. wall holder
Stationary antenna for wall fastening
For S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 2,5m for indoor and outdoor use incl. wall holder
85,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
688,00 €
plus VAT. and shipping
plus VAT. and shipping
726,00 €
plus VAT. and shipping
plus VAT. and shipping
1097,00 €
plus VAT. and shipping
plus VAT. and shipping
WLAN/WIFI-SETs
S5/S7-BRIDGE-WIFI-sets
Service-suitcase for couppling to a PLC over LAN/WLAN incl. all accessories
Service-suitcase for couppling to a PLC over LAN/WLAN incl. all accessories
ALF-WLAN/WIFI-Sets
Service-suitcase for couppling to a PLC over LAN/WLAN incl. all accessories
Service-suitcase for couppling to a PLC over LAN/WLAN incl. all accessories
All prices plus costs of delivery, shipping insurance and VAT.
9352-ALF-UA
ALF-UA high-speed WIFI-Router for Din-Rail-mounting Obsolete
Successor: CONNECT-Router for Din-Rail-mounting (Art.No: 9354-CONNECT-HS-ROUTER)
Industrial WIFI-Router for Unified Access Integrated USB-port Basic-plattform, functionality with software-options expandable One-click mounting
ALF-UA high-speed WIFI-Router for Din-Rail-mounting Obsolete
Successor: CONNECT-Router for Din-Rail-mounting (Art.No: 9354-CONNECT-HS-ROUTER)
Industrial WIFI-Router for Unified Access Integrated USB-port Basic-plattform, functionality with software-options expandable One-click mounting
0,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-LANCON
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
423,00 €
plus VAT. and shipping
plus VAT. and shipping
15,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
Automatic-mode
Main downloads
Versionstory
- Release-docu 3964R-LAN-firmware
- Release-docu ASCII-LAN-firmware
- Release-docu Multi-VCom
- Release-docu PLCVCom
- Release-docu S5-H1-PG-LAN-firmware
- Release-docu S5-LAN++-firmware
- Release-docu S5-LAN-Manager
- Release-docu S5-LAN-PATH-firmware
- Release-docu S5-Patch
- Release-docu S5-PG-LAN-firmware
- Release-docu S5-VCom
- Release-docu S7-LAN
- Release-docu Step7 TIC
Other downloads
Documentation
- Short instruction ALF-UA-WLAN/WIFI-Sets
- Example PUT/GET for Simatic-Manager and TIA-portal
- Examples of S5-/S7-coupling (S5-PLC and/or S7-PLC active)
- Example of S5-/S7-coupling (S7-PLC active, no changes on S5)
- Handbook S7-LAN/S7-GATE/MPI-LAN/S7-USB/MPI-USB/MPI-II
- Information-sheet S7-LAN
- Short instruction S7-interface (german only)
- Short instruction S7-LAN
- Example of use: S5anMPI
- Example of use: Watchdog-option
- Handbook ALF-UA (only german language)
- Handbook S5-LAN++
- Handbook S7-LAN (older version)
- S5 talks S7-TCP-IP RFC1006
Extension
- IPS7Link.advanced demo 32/64-bit windows (any)
- PG-2000 windows (any) V6.00
- IP-S7-Link-Demo incl. docu windows (any)
- PC-IP-S7-Link-Demo Linux 32/64-Bit incl. docu
- PC-S7-Easy-demo upto win/(32bit)
- PC-S7-LINK-Demo for LINUX
- PC-S5-LINK demo upto win/(32bit)
- S5-LAN-LINK-demo windows (any)
- OPCmanager windows (any)
- Victory windows (any)
- S5-Backup/Restore upto win7(32bit) V2.11