Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK
ALF-UA - Process Informatik Entwicklungsgesellschaft mbH

ALF-UA


Successor: CONNECT-Router for Din-Rail-mounting (Art.No: 9354-CONNECT-HS-ROUTER)

Industrial WLAN-Router +++ High-speed datarate 150 Mbit/s +++ Integrated firewall +++ Din-rail-mounting +++ Make your own WIFI

Industrial WIFI-Router for Unified Access
Integrated USB-port
Basic-plattform, functionality with
software-options expandable
One-click mounting

Also available as a set for universal use: ALF-UA-Sets

Features:
  • Client and Access-Point at the same time:
    Create your own hotspot and allow your participants to access the client-connected WiFi-network
  • Simple bilingual (E + G) web-interface
  • For S5-LAN++, S7-LAN and PROFINET usable
  • Easy and fast parameterization

more...
variants:


ARTNR: 9352-ALF-UA
ALF-UA high-speed WIFI-Router for Din-Rail-mounting
Obsolete
EAN number: 4260363247221
HS-code: 85176200
Weight: 0.17 kg


ALF-Devices

ALF ALF-UA ALF-UA-TISCH
Assembly / housing Tabletop unit DIN-rail assembly Tabletop unit
Search for access. nodes Simatic-Manager/TIA --- Yes Yes
Support WPS registration Yes --- ---
Easy configuration --- Yes Yes
Restart mandatory between config changes Yes No, just switch No, just switch
Language of the web interface only GB D / GB switchable D / GB switchable
Access-Point/Client at the same time --- Yes Yes
WAN-port can be used in AP-bridge-mode --- Yes Yes
WAN-port can be used in client-bridge-mode --- Yes Yes
USB port for future expansion --- Yes Yes
Passive POE (12V) Yes --- ---

ALF-Devices

ALF ALF-UA ALF-UA-TISCH
Assembly / housing Tabletop unit DIN-rail assembly Tabletop unit
Search for access. nodes Simatic-Manager/TIA --- Yes Yes
Support WPS registration Yes --- ---
Easy configuration --- Yes Yes
Restart mandatory between config changes Yes No, just switch No, just switch
Language of the web interface only GB D / GB switchable D / GB switchable
Access-Point/Client at the same time --- Yes Yes
WAN-port can be used in AP-bridge-mode --- Yes Yes
WAN-port can be used in client-bridge-mode --- Yes Yes
USB port for future expansion --- Yes Yes
Passive POE (12V) Yes --- ---

Operating-modes of the ALF-device and their function:

Operating-mode ALF ALF-UA
AP-Router
  • Build a WiFi-network
  • LAN-port and WiFi are in the same subnet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port must be another subnet, it will be routed here
  • Build a WiFi-network
  • LAN-port and WiFi are in the same subnet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port must be another subnet, it will be routed here
AP-Bridge
  • Build a WiFi-network
  • LAN-port and WiFi are in the same subnet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port is without function
  • Build a WiFi-network
  • LAN-port, WAN-port and WiFi are in the same subnet
    ⇒ all together communicating devices must be in the same subnet
Client-Router
  • Connects to existing WiFi-network
  • LAN-port and WiFi must be in the same SubNet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port must be another subnet, it will be routed here
  • Connects to existing WiFi-network
  • LAN-port and WiFi must be in the same SubNet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port must be another subnet, it will be routed here
Client-Bridge
  • Connects to existing WiFi-network
  • LAN-port and WiFi must be in the same SubNet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port is without function
  • Connects to existing WiFi-network
  • LAN-port, WAN-port and WiFi must be in the same SubNet
    ⇒ all together communicating devices must be in the same subnet

S7

PPI-Bus
PPI 9.6 KBit/s - 19.2 KBit/s
x
x
x
x
x
x
x
x
x
Multimaster 9.6 KBit/s - 187.5 KBit/s
x
x
x
x
x
x
x
x
MPI-Bus
19.2 KBit/s
x
x
x
x
x
x
x
x
x
187.5 KBit/s
x
x
x
x
x
x
x
x
x
1.5 MBit/s
x
x
x
x
x
x
x
x
Profibus
9.6 KBit/s
x
x
x
x
x
x
x
x
19.2 KBit/s
x
x
x
x
x
x
x
x
x
45.45 KBit/s
x
x
x
x
x
x
x
x
93.75 KBit/s
x
x
x
x
x
x
x
x
187.5 KBit/s
x
x
x
x
x
x
x
x
x
500 KBit/s
x
x
x
x
x
x
x
x
1.5 MBit/s
x
x
x
x
x
x
x
x
3.0 MBit/s
x
x
x
x
x
x
x
x
6.0 MBit/s
x
x
x
x
x
x
x
x
12.0 MBit/s
x
x
x
x
x
x
x
x
Profibus-profile
DP
x(12)
x
x
x
x
x
x
x
x
standard
x(12)
x
x
x
x
x
x
x
x
universal(DP/FMS)
x
x
x
x
x
x
x
x
RS 232
9.6 KBit/s
x(19)
x(19)
19.2 KBit/s
x
x
38.4 KBit/s
x
x
57.6 KBit/s
x(9)
x(9)
115.2 KBit/s
x(9)
x(9)
USB
USB 1.1 (6)
x(1)
x
x(2)
LAN
10/100BaseTx
x(7)
x
x
x
x
WIFI
2.4 GHz
x
TeleService operation
with S7-300/400
x(14)(18)
x(14)(18)
baud rates at TS-operation directly at the PC
9.6 KBit/s
x
x
19.2 KBit/s
x
x
38.4 KBit/s
x(8)
x(8)
57.6 KBit/s
x(8)
x(8)
baud rates at TS-operation directly with a modem
9.6 KBit/s
x
x
19.2 KBit/s
x
x
38.4 KBit/s
x
x
57.6 KBit/s
x
x
115.2 KBit/s
x
x
HMI
9.6 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
19.2 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
38.4 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
57.6 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
115.2 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
update
firmware-update
x(10)
x(10)
x(15)
x(15)
x(15)
x(15)
x(15)
x(15)
x(15)
input/online help                  
keypad
x
x
x
x(21)
x(21)
x(21)
x(21)
display
x
x
x
x
x(21)
x(21)
x(21)
x(21)
PD connections (maximum)                  
PLCVCOM
1
1
1
1
1
1
1
1
RFC1006
8
8
32
32
32
AG connections (maximum)
passive subscriber
1
15
15
15
15
15
15
15
15
active subscriber
126
126
126
126
126
126
126
126
126
more functions                  
integrated PLC-firewall
x
x
x
display diagnostic-buffer in the webbrowser
x
x
x
webserver for configuration
x
x
x
x
x
Remote access over existing VPN-channel
x
x
x
x
x
Access via existing WLAN-channel
x
x
x
x
x
status/control variable
x
x
x
x
x
S7 on S7/S5 DB exchange
x
x
x
x
x
S5 on MPI DB exchange
only as S5toMPI
S7 on MPI (Send/Fetch)
x
x
x
x
x
Profinet Gateway
x
x
x
x
x
Time in PLC from NTP-server
x
x
x
x
x
galvanic separation                  
to the bus (screen connected through)
1KV
1KV
1KV
1,5KV
1KV
1,5KV
1,5KV
1,5KV
1,5KV
mounting                  
wall monuting
(with opt. wall mounting-set)
x
x
x
x
upgrading with
CheapConn+cable
x
x
x
x
supports
WIN 98
x
x(3)
x
x
x
x
x
WIN 98 SE
x
x
x
x
x
x
x
x
x
WIN ME
x
x
x
x
x
x
x
x
x
WIN NT
x
x(5)
x(5)
x
x(5)
WIN 2000
x
x
x
x
x
x
x
x
x
WIN XP Home (4)
x
x
x
x
x
x
x
x
x
WIN XP Professional
x
x
x
x
x
x
x
x
x
Vista(32bit)
x
x
x
x
x
x
x
x
x
Win7(32bit)
x
x
x
x
x
x
x
x
x
Win7(64bit)
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win8/8.1
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win10
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win11
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)

(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1
(2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3
(3) only serial communication
(4) Siemens Step7 V5.2 and higher dont run with this operationing system
(5) USB-communication is only possible with the special driver for Win NT
(6) USB 2.0 is backward compatible to 1.1
(7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch
with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation
(8) only in combination with the MPI-Speed-driver („continously-active“)
(9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility
(10) Update directly with PC or via Tele-Network if the cable is connected to a device of the
Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional)
(11) only in the mode: MultiMaster-Mode
(12) up to a maximum baud rate of 187.5 KBit/s
(13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port.
(14) with the use of the TS-adapter / item number: 9350.TS
(15) Update directly with PC and TIC-driver
(18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens
(19) only at PPI-communication possible
(20) Only with TIC-driver
(21) with integrated webserver possible
(22) No support of Siemens Step7-software possible
(23) Only with USB and with TIC-driver

S5

device type
S5-90U
x
+ext. 24V
+ext. 24V
x
x
x
S5-95U
x
+ext. 24V
+ext. 24V
x
x
x
S5-100U
x
+ext. 24V(3)
+ext. 24V
x
x
x
S5-115U
at 944 + 9359-8
at 944 + 9359-8 + ext. 24V (4)
x
x
x
x
S5-135U
at 928B + 9359-8
at 928B + 9359-8 +ext. 24V (6)
x
x
x
x
S5-155U
x
x
x
x
x
x
S5-AG110S
+9359-5-150 + 9359-4
+ ext. 24V (3)
+9359-5-150 + ext. 24V
S5-AG130W/B
+9359-5-150 + 9359-4
+ ext. 24V (3)
+9359-5-150 + ext. 24V
S5-AG150A/K/S/U
+9359-5-150 + 9359-4
+ ext. 24V (3)
+9359-5-150 + ext. 24V
CP-143
x
x
x
CP-521
+CP521 adapter
       
+CP521 adapter(1)
CP-523
+CP523 adapter
       
+CP523 adapter(1)
CP-525      
+9359-5(1)
CP-526
x
   
x
 
x
CP-527
x
   
x
 
x
CP-528
x
   
x
 
x
CP-544
x (7)
   
x (7)
 
x (7)
CP-5430
x
   
x
 
x
CP-5431
x
   
 
IP-246
x
   
x
 
x
IP-247
x
   
x
 
x
IP-252
x
   
x
 
x
IP-266
 
x
+9359-4(1)
WF-470
SIN-805
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
+9359-6(1)
SIN-820
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
+9359-6(1)
SIN-840
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
+9359-6(1)
SIN-850
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
+9359-6(1)
SIN-880
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
 
+9359-6(1)
Connection on PC
RS232-port
Ethernet RJ45
Ethernet RJ45 / WLAN/WIFI
USB-port type A
RS232-port
RS232-port
max. prolongation: 300m (UNI-extension) 300m (S5-LAN-extension) +ext. 24V 100m (PG-USB-extension)   300m (UNI-extension)

(1) ISO adapter can not be used because the required supply voltage on the PG interface of the module is not present.
(2) At the CPU 6ES5 102-8MA02 Release 3 is a PG-ISO-Adapter or Netz-Adapter additional required.
(3) With S5-LAN++ from HW V2.3 [2010] the "Netz-Adapter" is no more needed, this version has included current-sources.
(4) With S5-LAN++ from HW V2.3 [2010] no accessories are needed, this version has included current-sources.
(5) With S5-LAN++ from HW V2.3 [2010] the Sinum-Adapter 9359-6-USB is needed.
(6) Only for CPU928B with PG-ISO-Adapter and ext. 24V DC, unless there is an S5-LAN++ from HW V2.3 [2010] used.
(7) CP544 has bolts at the programming-interface. The products do not fit 100% on this interface.
(8) With S5-BRIDGE the Sinum-Adapter 9359-6-USB is needed.

Remote maintenance

TELE LINK NETWORK
         
 
secured modem-protocol
additional software needed
Siemens TS -Software
Siemens TS -Software
VPN-Client
VPN-Client
Providing WinTELEPROF-software
modem
analogue/ISDN
analogue
opt. via PCMCIA
analogue/GSM
analogue/ISDN/GSM
internet-connection
internet-connection
internet-connection
modem for world wide use
interfaces
MPI/Profibus
9600-12MBd
9600-12MBd
9600-12MBd
9600-12MBd
RS232
2x
2x
2x
1x
1x
TTY
2x
2x
2x
1x
PCMCIA
2x (optionally)
1x
1x
Ethernet
10/100BaseTx
1x
1x
5x
USB
2x
1x
LCD-display
instead 10 LEDs
instead status-LED
instead webserver
instead webserver
supported PLC-protocols *
S7
S5
✓ (optional)
✓ (optional)
Pilz PSS
✓ (optional)
✓ (optional)
Allen-Bradley
✓ (optional)
✓ (optional)
AEG
✓ (optional)
✓ (optional)
Bosch
✓ (optional)
✓ (optional)
Telemecanique
✓ (optional)
✓ (optional)
GE-Fanuc
✓ (optional)
✓ (optional)
Klöckner-Moeller
✓ (optional)
✓ (optional)
Mitsubishi
✓ (optional)
✓ (optional)
SMS-sending/Pager(S5/S7)
✓ (no pager)
only for analogue / ISDN
HMI-messaging module(S5/S7)
SMS-receive with GSM
DTMF with analogue
e-mail-dispatch
FAX-dispatch(S5/S7)
✓ (optional)
✓ (optional)
only for analogue / ISDN
PLC-data coupling(S5/S7)
✓ (optional)
✓ (optional)
ASCII-transfer from S5/S7
✓ (optional)
✓ (optional)
only with ASCII-LAN
internet-coupling
Usage as dial-up-router
power supply
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
dimensions w x h x d (in mm)
High: 67 x 280 x 170
FLAT: 300 x 175 x 70
300 x 175 x 66
235 x 162 x 37
90 x 162 x 54
40 x 125 x 115
42 x 15 x 65
65 x 43 x 17
154 x 92 x 28

* other PLC types on request

Wöhrle Belgium B.V.B.A.
Mechelen , Belgium
www.wohrle.be
Also available as a set for universal use: ALF-UA-Sets

Features:
  • Client and Access-Point at the same time:
    Create your own hotspot and allow your participants to access the client-connected WiFi-network
  • Simple bilingual (E + G) web-interface
  • For S5-LAN++, S7-LAN and PROFINET usable
  • Easy and fast parameterization
  • USB-port for software-extensions
  • Connecting a network subscriber (also over switch) as Client to an Access Point
  • Can be also driven as an Access-Point
  • No/ configuration of AdHoc-mode on the notebook needed
  • Configuration with included multilingual web-server
  • Auto-negotiation of the RJ45-Ethernet jack
  • Integrated DHCP-server
  • High data-transfer; providing data rates of up to 150Mbps; is compatible with legacy 802.11b/g equipment
  • Integrated firewall with SPI to protect the internal host from hacker attacks
  • Wireless security is comprehensive and includes WEP/WPA/WPA2 PSK
  • Provides helpful features like Rich WDS, Dual SSIDs, Static Routing, QoS and more
  • For Din-Rail-mounting
  • Power supply 24V DC over spring-contact
Start-Window: (mouse-click for enlargement)


Configuration-Overview:

Simultaneous parameterization of all operating-modes possible, there is always only one of them "active" switched.

Differences between ALF (art.nr.: 9352-ALF) and ALF-UA (art.nr.: 9352-ALF-UA / 9352-ALF-UA-TISCH)

ALF ALF-UA ALF-UA-TISCH
Assembly / housing Tabletop unit DIN-rail assembly Tabletop unit
Search for access. nodes Simatic-Manager/TIA --- Yes Yes
Support WPS registration Yes --- ---
Easy configuration --- Yes Yes
Restart mandatory between config changes Yes No, just switch No, just switch
Language of the web interface only GB D / GB switchable D / GB switchable
Access-Point/Client at the same time --- Yes Yes
WAN-port can be used in AP-bridge-mode --- Yes Yes
WAN-port can be used in client-bridge-mode --- Yes Yes
USB port for future expansion --- Yes Yes
Passive POE (12V) Yes --- ---

Operating-modes of the ALF-device and their function:

Operating-mode ALF ALF-UA
AP-Router
  • Build a WiFi-network
  • LAN-port and WiFi are in the same subnet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port must be another subnet, it will be routed here
  • Build a WiFi-network
  • LAN-port and WiFi are in the same subnet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port must be another subnet, it will be routed here
AP-Bridge
  • Build a WiFi-network
  • LAN-port and WiFi are in the same subnet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port is without function
  • Build a WiFi-network
  • LAN-port, WAN-port and WiFi are in the same subnet
    ⇒ all together communicating devices must be in the same subnet
Client-Router
  • Connects to existing WiFi-network
  • LAN-port and WiFi must be in the same SubNet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port must be another subnet, it will be routed here
  • Connects to existing WiFi-network
  • LAN-port and WiFi must be in the same SubNet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port must be another subnet, it will be routed here
Client-Bridge
  • Connects to existing WiFi-network
  • LAN-port and WiFi must be in the same SubNet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port is without function
  • Connects to existing WiFi-network
  • LAN-port, WAN-port and WiFi must be in the same SubNet
    ⇒ all together communicating devices must be in the same subnet
Profinet WLAN panel connection
Produkbild

Simply connect your panel to your Profibus via WLAN.
Mobile workplaces are optimally connected.
You will be able to link additional applications such as PDs, visualizations or ERP systems at the same time.

Current S7 panels via WLAN to the S5 controller
Produkbild

Connect each S7-TCP-IP panel to your S5.
Now also available via WLAN for mobile workstations.
PARALLEL several panels and even simultaneous PG connections possible.
Include hard-to-reach places in your ERP system.

Link S7-TCP-IP Panel to MPI Profibus over WiFi
Produkbild

Use the latest S7-TCP-IP panels for your MPI / Profibus.
Thanks to WLAN also usable for mobile platforms or cranes.
Connect several nodes at the same time via a network module.
Simultaneous access from different systems possible.

Link S7-TCP-IP Panel to MPI Profibus over WiFi
Produkbild

Use the latest S7-TCP-IP panels for your MPI / Profibus.
Thanks to WLAN also usable for mobile platforms or cranes.
Connect several nodes at the same time via a network module.
Simultaneous access from different systems possible.

Wireless around the Allen-Bradley-PLC
Produkbild

Move wirelessly around the Allen-Bradley-PLC and communicate for example ONLINE in the status

Wireless around the Beckhoff-PLC
Produkbild

Move wirelessly around the Beckhoff-PLC and communicate for example ONLINE in the status

Wireless around the Bosch-PLC
Produkbild

Move wirelessly around the Bosch-PLC and communicate for example ONLINE in the status

Wireless around the Eaton-PLC
Produkbild

Move wirelessly around the Eaton-PLC and communicate for example ONLINE in the status

Wireless around the machine with LAN-port
Produkbild

Move wirelessly around the machine with LAN-port and communicate for example ONLINE in the status

Wireless around the Mitsubishi-PLC
Produkbild

Move wirelessly around the Mitsubishi-PLC and communicate for example ONLINE in the status

Wireless around the Moeller-PLC
Produkbild

Move wirelessly around the Moeller-PLC and communicate for example ONLINE in the status

Wireless around the Pilz-PLC
Produkbild

Move wirelessly around the Pilz-PLC and communicate for example ONLINE in the status

Wireless around the ProfiNet-PLC
Produkbild

Move wirelessly around the ProfiNet-PLC and communicate for example ONLINE in the status

Wireless around the S5-PLC
Produkbild

Move wirelessly around the S5-PLC and communicate for example ONLINE in the status

Wireless around the S7-PLC
Produkbild

Move wirelessly around the S7-PLC and communicate for example ONLINE in the status

Wireless around the Schneider-PLC
Produkbild

Move wirelessly around the Schneider-PLC and communicate for example ONLINE in the status

Supply voltage: 24V DC +/- 20%
Power consumption: 1,2 watt
Display: status-LEDs
Handling/Configuration: with integrated webserver
Interfaces:
to antenna:
RP-SMA-female connector (reverse polarity) with 5 dBi
(Power out: 20 dB)
to the PLC:
10/100BaseTX RJ45-ethernetplug
to the PD/PC:
WLAN connection (802.11 b/g/n)
Security WEP 64/128bit
WPA (TKIP with IEEE 802.1x)
WPA2 (AES with IEEE 802.1x)
WPA Mixed
Operating temperature: 0 - 55°C
Case: plastic clamping-case
Dimensions: 114 x 100 x 22.3 mm
 
Scope of delivery: ALF-UA
WIFI-stub-antenna
All prices plus costs of delivery, shipping insurance and VAT.

accessories:

9391.1
24V DC power-supply unit 625mA

Primary 110V - 240 VAC Euro+USA-plug
Quickbestellung INFOMAIL
by e-mail
59,00 €
plus VAT. and shipping


9379-AV
Antenna extension GSM/LTE/WIFI
Base-price + cable length #9379-AV-L
Quickbestellung INFOMAIL
by e-mail
40,00 €
plus VAT. and shipping


9379-AV-L
Additional charge for special length
for antenna extension per meter 4,- Euro
Quickbestellung INFOMAIL
by e-mail
4,00 €
plus VAT. and shipping


9352-ALF-ANT-WAND
Stationary antenna for wall fastening

for ALF and CONNECT-ROUTER, cable length: 2,5m for indoor and outdoor use incl. wall holder
Quickbestellung INFOMAIL
by e-mail
85,00 €
plus VAT. and shipping


9391-USB
USB-powercable for 24V DC, max. 3W

USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
Quickbestellung INFOMAIL
by e-mail
95,00 €
plus VAT. and shipping


price on request
plus VAT. and shipping

9352-ALF-SEKT-ANT
Sector antenna for ALF

Sector antenna with 17dBi power gain and bundled radiation. Connection cable optional
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

9352-ALF-RICHT-ANT
Beam antenna for ALF

Beam antenna with 17dBi power gain for classic radio link connection cable optional
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

9350-9-CHP-24V-OUT
CheapConn Busconnector with 24V-output

Comfortable power supply for ALF, TONI, WLAN-Klemme and CONNECT-ROUTER
Quickbestellung INFOMAIL
by e-mail
85,00 €
plus VAT. and shipping


9636-TCPIP.1M
Patch-cable 1m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
Quickbestellung INFOMAIL
by e-mail
15,00 €
plus VAT. and shipping


9352-ALF-ANT
Magnetic base antenna for indoor use

for ALF, ALF-UA- S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m
Quickbestellung INFOMAIL
by e-mail
83,00 €
plus VAT. and shipping


9636-TCPIP.02M
Patch-cable 0.25m, Cat5e, shielded

RJ45 plug <=> RJ45 plug, 1:1
Quickbestellung INFOMAIL
by e-mail
15,00 €
plus VAT. and shipping


9636-CROSS
Cross-cable 3m Cat5+, shielded

RJ45 plug <=> RJ45 plug, twisted pinning
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


9636-TCPIP
Patch-cable 3m, Cat5+, shielded

RJ45 plug <=> RJ45 plug, 1:1
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


All prices plus costs of delivery, shipping insurance and VAT.

9352-ALF-UA
ALF-UA high-speed WIFI-Router for Din-Rail-mounting Obsolete

Successor: CONNECT-Router for Din-Rail-mounting (Art.No: 9354-CONNECT-HS-ROUTER)
Industrial WIFI-Router for Unified Access Integrated USB-port Basic-plattform, functionality with software-options expandable One-click mounting
Quickbestellung INFOMAIL
by e-mail
0,00 €
plus VAT. and shipping



maximum 3 articles
9352-ALF-UA-TISCH
ALF-UA high-speed WIFI-Router table-device Obsolete

Successor: CONNECT-Router table-device (Art.No: 9354-CONNECT-ROUTER)
Industrial WIFI-Router for Unified Access Integrated USB-port Basic-plattform, functionality with software-options expandable table-device
Quickbestellung INFOMAIL
by e-mail
0,00 €
plus VAT. and shipping



maximum 3 articles
0,00 €
plus VAT. and shipping



maximum 3 articles

All prices plus costs of delivery, shipping insurance and VAT.

9352-ALF-ANT
Magnetic base antenna for indoor use

for ALF, ALF-UA- S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m
Quickbestellung INFOMAIL
by e-mail
83,00 €
plus VAT. and shipping


9359-LAN
S5-LAN++

Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
Quickbestellung INFOMAIL
by e-mail
452,00 €
plus VAT. and shipping


9352-LANCON
S7-LAN connector for Siemens S7 PLC controller

Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
Quickbestellung INFOMAIL
by e-mail
423,00 €
plus VAT. and shipping


9391.1
24V DC power-supply unit 625mA

Primary 110V - 240 VAC Euro+USA-plug
Quickbestellung INFOMAIL
by e-mail
59,00 €
plus VAT. and shipping


Automatic-mode

Main downloads

Versionstory

Other downloads

Extension

Support-videos