Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer

integrated access-protection LAN <=> bus-side
- IP-address-filter
- MAC-filter
- read/write protection of individual variables,
inputs/outputs, blocks
Display of the S7-diagnostics-buffer in the
webbrowser
(no Simatic Manager/TIA Portal required)
increased performance/data throughput (up to
300%) like S7-LAN module
up to 32 parallel connections

Features:
  • S7-PLC-Firewall in the form of a bus plug
  • Monitors/regulates Network-accesses on the connected PPI-, MPI- Profibus
  • Display of PLC diagnostic buffer in the WebServer
  • Built-in PG diagnostic socket
  • Parameterization via integrated WebServer
  • Standard functions like S7-LAN connector

The PLC-firewall monitors:

    more...
    variants:

    423,00 € plus VAT. and shipping

    ARTNR: 9352-LANCON++
    S7-LAN++ connector for Siemens S7 Controller
    HS-code: 85423190
    Weight: 0.06 kg



    S7

    PPI-Bus
    PPI 9.6 KBit/s - 19.2 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Multimaster 9.6 KBit/s - 187.5 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    MPI-Bus
    19.2 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    187.5 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    1.5 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    Profibus
    9.6 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    19.2 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    45.45 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    93.75 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    187.5 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    500 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    1.5 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    3.0 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    6.0 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    12.0 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    Profibus-profile
    DP
    x(12)
    x
    x
    x
    x
    x
    x
    x
    x
    standard
    x(12)
    x
    x
    x
    x
    x
    x
    x
    x
    universal(DP/FMS)
    x
    x
    x
    x
    x
    x
    x
    x
    RS 232
    9.6 KBit/s
    x(19)
    x(19)
    19.2 KBit/s
    x
    x
    38.4 KBit/s
    x
    x
    57.6 KBit/s
    x(9)
    x(9)
    115.2 KBit/s
    x(9)
    x(9)
    USB
    USB 1.1 (6)
    x(1)
    x
    x(2)
    LAN
    10/100BaseTx
    x(7)
    x
    x
    x
    x
    WIFI
    2.4 GHz
    x
    TeleService operation
    with S7-300/400
    x(14)(18)
    x(14)(18)
    baud rates at TS-operation directly at the PC
    9.6 KBit/s
    x
    x
    19.2 KBit/s
    x
    x
    38.4 KBit/s
    x(8)
    x(8)
    57.6 KBit/s
    x(8)
    x(8)
    baud rates at TS-operation directly with a modem
    9.6 KBit/s
    x
    x
    19.2 KBit/s
    x
    x
    38.4 KBit/s
    x
    x
    57.6 KBit/s
    x
    x
    115.2 KBit/s
    x
    x
    HMI
    9.6 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    19.2 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    38.4 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    57.6 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    115.2 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    update
    firmware-update
    x(10)
    x(10)
    x(15)
    x(15)
    x(15)
    x(15)
    x(15)
    x(15)
    x(15)
    input/online help                  
    keypad
    x
    x
    x
    x(21)
    x(21)
    x(21)
    x(21)
    display
    x
    x
    x
    x
    x(21)
    x(21)
    x(21)
    x(21)
    PD connections (maximum)                  
    PLCVCOM
    1
    1
    1
    1
    1
    1
    1
    1
    RFC1006
    8
    8
    32
    32
    32
    AG connections (maximum)
    passive subscriber
    1
    15
    15
    15
    15
    15
    15
    15
    15
    active subscriber
    126
    126
    126
    126
    126
    126
    126
    126
    126
    more functions                  
    integrated PLC-firewall
    x
    x
    x
    display diagnostic-buffer in the webbrowser
    x
    x
    x
    webserver for configuration
    x
    x
    x
    x
    x
    Remote access over existing VPN-channel
    x
    x
    x
    x
    x
    Access via existing WLAN-channel
    x
    x
    x
    x
    x
    status/control variable
    x
    x
    x
    x
    x
    S7 on S7/S5 DB exchange
    x
    x
    x
    x
    x
    S5 on MPI DB exchange
    only as S5toMPI
    S7 on MPI (Send/Fetch)
    x
    x
    x
    x
    x
    Profinet Gateway
    x
    x
    x
    x
    x
    Time in PLC from NTP-server
    x
    x
    x
    x
    x
    galvanic separation                  
    to the bus (screen connected through)
    1KV
    1KV
    1KV
    1,5KV
    1KV
    1,5KV
    1,5KV
    1,5KV
    1,5KV
    mounting                  
    wall monuting
    (with opt. wall mounting-set)
    x
    x
    x
    x
    upgrading with
    CheapConn+cable
    x
    x
    x
    x
    supports
    WIN 98
    x
    x(3)
    x
    x
    x
    x
    x
    WIN 98 SE
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN ME
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN NT
    x
    x(5)
    x(5)
    x
    x(5)
    WIN 2000
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN XP Home (4)
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN XP Professional
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Vista(32bit)
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Win7(32bit)
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Win7(64bit)
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    Win8/8.1
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    Win10
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    Win11
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)

    (1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1
    (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3
    (3) only serial communication
    (4) Siemens Step7 V5.2 and higher dont run with this operationing system
    (5) USB-communication is only possible with the special driver for Win NT
    (6) USB 2.0 is backward compatible to 1.1
    (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch
    with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation
    (8) only in combination with the MPI-Speed-driver („continously-active“)
    (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility
    (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the
    Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional)
    (11) only in the mode: MultiMaster-Mode
    (12) up to a maximum baud rate of 187.5 KBit/s
    (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port.
    (14) with the use of the TS-adapter / item number: 9350.TS
    (15) Update directly with PC and TIC-driver
    (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens
    (19) only at PPI-communication possible
    (20) Only with TIC-driver
    (21) with integrated webserver possible
    (22) No support of Siemens Step7-software possible
    (23) Only with USB and with TIC-driver
    Features:
    • S7-PLC-Firewall in the form of a bus plug
    • Monitors/regulates Network-accesses on the connected PPI-, MPI- Profibus
    • Display of PLC diagnostic buffer in the WebServer
    • Built-in PG diagnostic socket
    • Parameterization via integrated WebServer
    • Standard functions like S7-LAN connector

    The PLC-firewall monitors:
    • IP-addresses, i.e. it determines which IP-address is allowed to access the connected bus and which is not
             
    • Write/read access to variables/data areas of the individual bus-participants
             
    • PG functions allowed/prohibited depending on the IP-address
             
    Management of the IP address
    Produkbild

    The IP filter is used to determine whether or not the entered IP-addresses or IP-address-ranges may communicate with the connected controllers via the module.
    The list can be edited centrally be switched with a button from "allowed" on "not allowed".

    Management of the data-areas
    Produkbild

    With the management of the data-areas it is determined whether the entered data-areas can be read/written via the module with the connected controllers. A central button for the function determines whether the specified inputs are "allowed" or "not allowed" are.
    The input itself is kept very simple: "r" for reading and "w" for writing, a ":" as a separator and then the data-area in S7-format. If there is only one CPU on the bus, the CPU-address does not even have to be specified, the participant on which the module is plugged in is used.

    Display diagnostic-buffer without Simatic-Manager
    Produkbild

    Via the connection-menu and the included bus-device-display, it is possible to display the diagnostics buffer of the respective device without having to open Simatic-Manager or TIA-Portal separately.
    The data received from the module is output directly in one piece without the hassle of changing tabs. All data at a glance.

    Supply voltage: 24V DC +/- 20%
    Power consumption: 2 watt
    Display: Web-Browser
    2 status-LEDs
    Handling/Configuration: Web-Browser
    TIC-Software
    Interfaces:
    to the PLC:
    PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
    to the PD/PC:
    PD/diagnosis jack
    10/100BaseTX RJ45-ethernet jack (auto select)
    Galvanic separation: 1500V PPI/MPI/Profibus to the PC
    Operating systems: MS-Windows NT, 2000, XP, Vista / Win7/8/10/11 32/64 Bit
    Protocols: RFC1006, DHCP, HTTP
    Operating temperature: 0 - 55°C
    Case: ABS-plastic case
    Dimensions: 65 x 43 x 17 mm
     
    Scope of delivery: S7-LAN++-module
    Power connector 2pins small
    All prices plus costs of delivery, shipping insurance and VAT.

    accessories:

    9391.1
    24V DC power-supply unit 625mA

    Primary 110V - 240 VAC Euro+USA-plug
    Quickbestellung INFOMAIL
    by e-mail
    59,00 €
    plus VAT. and shipping


    9391-USB
    USB-powercable for 24V DC, max. 3W

    USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
    Quickbestellung INFOMAIL
    by e-mail
    95,00 €
    plus VAT. and shipping


    84,00 €
    plus VAT. and shipping


    9636-CROSS
    Cross-cable 3m Cat5+, shielded

    RJ45 plug <=> RJ45 plug, twisted pinning
    9636-TCPIP
    Patch-cable 3m, Cat5+, shielded

    RJ45 plug <=> RJ45 plug, 1:1
    9352-24
    Power connector 2pins small

    cable coupling by screw-connector (small)
    Quickbestellung INFOMAIL
    by e-mail
    4,00 €
    plus VAT. and shipping


    9352-S7-BK
    S7-bus-coupler

    Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
    Quickbestellung INFOMAIL
    by e-mail
    42,00 €
    plus VAT. and shipping


    All prices plus costs of delivery, shipping insurance and VAT.

    9352-LANCON++
    S7-LAN++ connector for Siemens S7 Controller

    Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
    Quickbestellung INFOMAIL
    by e-mail
    423,00 €
    plus VAT. and shipping




    maximum 3 articles
    9352-LANCON
    S7-LAN connector for Siemens S7 PLC controller

    Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
    Quickbestellung INFOMAIL
    by e-mail
    423,00 €
    plus VAT. and shipping




    maximum 3 articles
    9352-S7-GATE
    S7-GATE connector with integrated firewall for Siemens S7-PLCs

    Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
    Quickbestellung INFOMAIL
    by e-mail
    499,00 €
    plus VAT. and shipping




    maximum 3 articles
    9352-S7-WIFI
    S7-BRIDGE

    Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI
    Quickbestellung INFOMAIL
    by e-mail
    741,00 €
    plus VAT. and shipping




    maximum 3 articles

    All prices plus costs of delivery, shipping insurance and VAT.

    9352-LANCON
    S7-LAN connector for Siemens S7 PLC controller

    Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
    Quickbestellung INFOMAIL
    by e-mail
    423,00 €
    plus VAT. and shipping


    9359-LAN
    S5-LAN++

    Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
    Quickbestellung INFOMAIL
    by e-mail
    452,00 €
    plus VAT. and shipping