S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
Operating as a client or access-point
Configuration via web-server
Supply: 24V DC
Variant with integrated access-protection LAN <=> bus-side as well as output of diagnostic-buffer in web-site
Networking of SIMATIC S7-PLCs (S7-200/300/400) without Ethernet-CP/CP-communicationprocessor standard-TCP/IP without changes to the hardware-configuration or PLC-program.
Compact and robust Ethernet-converter (MPI / PROFIBUS / PPI - Ethernet).
Similar to "IBH Link S7++" (IBH-Link-S7-PP, 20266), "NETLink PRO Compact", "ACCON-NetLink-PRO compact" or "NL 50-MPI".
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET function.
By plugging the module onto the PPI, MPI or Profibus, this connection becomes an Ethernet port for the Industrial IoT with significant cost savings.
Thanks to the integrated multiplexer, this connection becomes a port for all supported protocols. Simultaneous and parallel communications such as WinCC, PUT/GET from S7 PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step7, TIA Portal or PG2000.
Advantages:
more...
ARTNR: 9201
EtherSens Basic
EAN number: | 4260363244282 | |
HS-code: | 85423190 | |
Weight: | 0.3 kg |
Variant with integrated access-protection LAN <=> bus-side as well as output of diagnostic-buffer in web-site
Networking of SIMATIC S7-PLCs (S7-200/300/400) without Ethernet-CP/CP-communicationprocessor standard-TCP/IP without changes to the hardware-configuration or PLC-program.
Compact and robust Ethernet-converter (MPI / PROFIBUS / PPI - Ethernet).
Similar to "IBH Link S7++" (IBH-Link-S7-PP, 20266), "NETLink PRO Compact", "ACCON-NetLink-PRO compact" or "NL 50-MPI".
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET function.
By plugging the module onto the PPI, MPI or Profibus, this connection becomes an Ethernet port for the Industrial IoT with significant cost savings.
Thanks to the integrated multiplexer, this connection becomes a port for all supported protocols. Simultaneous and parallel communications such as WinCC, PUT/GET from S7 PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step7, TIA Portal or PG2000.
Advantages:
- Simple and fast networking
- Multiplexer for all protocols
- Integration as S7 controller with CP 343-1
- Access to S7 data via S7-TCP/IP with PUT/GET
- Module search without "annoying" network-card-selection
- Free virtual-com-port for non-Step7-applications
- Qualified support
- Comprehensive documentation
- No SimaticNet required for operation/configuration
- STEP7 64-bit support
- Integration into the TIA-Portal
- Supports DHCP
Connectivity:
- S7-LAN module directly connected to the PC/device with a patch cable
- S7-LAN module directly connected to the PC/device with a crosslink cable
- S7-LAN connected to the PC/device via a switch or hub
Features:
- every SIMATIC-S7 (S7-200/300/400) into Network
- SIMATIC S7-protocols (S7Comm and ISO-on-TCP (RFC 1006))
- Ethernet-RJ45 socket with 10/100 MBit/s with autonegotiation
- Commissioning is very simple: plug it into the PPI, MPI-bus or PROFIBUS of the SIMATIC S7 controller and start working
- Integrated multiplexer (visualization, programming, remote maintenance and simultaneous use of all protocols without special configuration), also via standard router
- Parallel use of the channels (simultaneously 8 x channels for programming, visualization and remote maintenance can be used directly/routed)
- Supported controllers (S7-200, S7-300, S7-400, FM modules, Sinamix, Sinumerik, MicroMaster and other drives/converters (such as SEW-EURODRIVE converters)
- Supported data areas (inputs, outputs, markers, data blocks, timers and counters)
- Supported scenarios (programming adapter for S7 programming packages, access to the S7 data via S7-TCP/IP with PUT/GET and routing of SIMATIC S7 controllers as well as time server for time and also bus diagnostics)
- Supported platforms (S7-TCPIP RFC1006 communication platform-independent, communication driver/configuration tool TIC for Windows XP, Win7/8/10/11)
- Replacement for CP343-1/443-1 or IE/PB-Link, connected directly to MPI or Profibus (inexpensive)
- with Profibus for S7-300 faster than CP343-1
- PG/PC-adapter for Simatic-Manager Step7 and TIA-portal
- fastest installation into Network (less than 3 minutes)
- automatic detection of baudrate
- automatic usement of cyclic bus-parameter-protocols
- no bus-knowledge required / automatic-protocol and baud-rate detection
- download TIC-driver for STEP-7/TIA-Portal
- Programming and visualization at the same time (8 S7-connections (direct / routed) at the same time)
- compatible to S7-TCP/IP RFC1006, WinCC (flex), OPC UA with Universal communication Industry 4.0, the IP-S7LINK SDK as well as all common OPC-servers
- no HW-Config change necessary
- no change of PLC-software necessary
- including Classic OPC-DA-Server-lite (max. 100 variables)
- with PG-diagnostic-port (occupied slot with 9pin PG-port free again)
- DPV1-master of class 2 and supports all functions that a PG supports:
- Diagnosis, configuration and programming of controllers (via software such as Simatic-Manager, TIA-Portal)
- Diagnosis and configuration of DP-slaves (via software such as Starter)
- active module, no influencing other bus users in the system
- active PUT/GET (in module integrated) replaces expensive CP´s for PLC-couplings
- Supply from S7-PLC or 24V DC external
- CE/EMC compliant design
- Scope of delivery (TIC driver, module itself and quick start guide)
- Search for modules across all Network-cards (no Network-card-selection as with other providers)
- Variable status in web interface
- RFC1006 connection status
- PLC-time via PG-protocol
- TCPIP-device writes/reads DB in S7-PLC
- Bus-diagnostics (output of error-counters, spikes)
- RFC1006 for S7-200 (1. Generation)
- virtual COM-port-driver for other serial S7-applications
- Standard HMI-applications can read/write data via RFC1006 and the module
Applications:
- Operational data collection, SCADA of non-networkable controllers
- KTP-panel to S7-PLC with MPI-/Profibus-interface
- PUT/GET from S7-1500/1200/300/400 (PN-CPU or with ethernet-CP) with specified and unspecified connection
- VPN(Virtual Private Network)-remote-maintenance, maintenance of the PLC via the Internet
- cyclic time reading from NTP-server and setting in the connected PLC
- coupling with DB-transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or also S5-Gateway
- any TCP-device writes/reads DBs in the S7-300/400 controller
- monitor variables in the WebServer without a Step7 programming-package
- analysis option of the connected bus-system with spikes- and errors-counter
- Parameterization of field devices and drives (DPV1)
- With IP-S7-Link-DLL high-level languages-access
- PLC-PLC-communication (regardless of subnet boundaries, prolongation MPI/DP-bus over network)
TIC-(Totally Integrated Communication)-driver for Step7/TIA-Portal for Win XP/VISTA/7/8/10/11 32/64 Bit:
TIC firmware / configuration-tool / Step7-/TIA-driver
Product overview:
S7-LAN is a reliable and handy S7-network-adapter for PPI-,MPI- and PROFIBUS. Designed for 24/7-operation. The compact design in the PROFIBUS-connector-case and the power supply directly from the MPI/DP-port of the CPU allow to be connected a PLC to the network in less than 3 minutes.bus protocols/bus profile, incl. baudrate and HSA are recognized independently and automatically and configured.
HMI-devices, for e.g. actual panel-series, as well as any other S7-Ethernet device, direct connect per S7-TCP-IP.
With TIC-driver (configurations-tool and driver) from download-area without changes on the project of Siemens TIA, Simatic Step7 Manager and WinCC-projects communication.
Another advantage is the easy handling of the S7-LAN. The convenient configuration is carried out directly in STEP7 or the PG/PC-interface-dialog. The detection of whether the S7-LAN is connected to a 10 MBit or 100 MBit network takes place automatically. Power is supplied directly from the MPI / DP interface. The connection to passive participants or VIPA-PLC is possible via the integrated 24V-plug.
The S7-LAN is connected to the bus-socket of the PLC and via the hub or directly to the PC. Then install the TIC-driver on the PC. Assign the IP-address with the TIC-configuration-program and go ONLINE. The installation process is completed so quickly.
Configuration:
S7-LAN is designed for quick commissioning. After the module has been plugged into the bus or externally supplied with 24V DC, only an IP address is assigned via the TIC-driver or directly via the Web-interface . The controllers can then be accessed from the network.With the TIC-driver, there is no need for any additional installation outside of the Siemens world. The configuration takes place directly in the PG-PC interface settings and is therefore optimally integrated. Any network device that speaks S7-TCP/IP RFC1006, such as HMI-devices or PGs, can access the module directly.
In the S7-project itself, the adapter can be integrated using a placeholder entry. This is not a must, operation without project change is possible immediately. The S7-communication runs directly via S7-TCP/IP and expands each MPI-/PROFIBUS with a network gateway. It doesn't matter which control types (S7-200 / S7-300 / S7-400) are connected to the fieldbus of the PLC network.
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PN-port to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on SD card
Via digital input triggered DB-backup/-restore without additional PC via PN-port to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via PN-port to USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PN-port to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on SD-card
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to USB-stick
Send directly from your PLC news, statuses, alarms as SMS or email.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2 watt |
Display: |
WEB-Browser 1 status LED bicolor |
Handling/Configuration: | WEB-Browser |
Interfaces: |
Slot for microSD Antenna-connector SMA(f) (2.4 GHz IEEE 802.11b/g) 10/100BaseTX RJ45-ethernet-plug Button for factory settings |
Overvoltage category: | CAT IV |
Insulation value network <=> mains voltage: |
1,5 KV |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case V0 |
Dimensions: | 100 x 112 x 45 mm |
Scope of delivery: |
EtherSens Basic WIFI-stub-antenna |
extensions:
Extension Analog-IO V1.0
Extension-board for EtherSens-devices 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Extension with ext. galv. separated I2C 5V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 5V Power consumption: 2W
plus VAT. and shipping
Extension LTE-modem
LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
plus VAT. and shipping
Extension Energy-IO
Extension-board for EtherSens-devices Energy-analysis (EN 50470-1 EN 50470-3) L1, L2, L3, N realtime analysis Up to 8000 measurements / second Hz / cos phi / power-factor Energy consumption kWh For Rogwski-coils up to 0,5V
plus VAT. and shipping
U-I-box for EtherSens
max. 1000V DC / 40A 24V DC supply 20cm power-cable 4mm2 with Amphenol-plug I2C-connection 1m
plus VAT. and shipping
Sun-light-sensor for EtherSens
max. 220k Lux (switchable ranges) 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 312 for EtherSens
Measuring range: ±1.5g / ±3g / ±6g / ±12g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 313 for EtherSens
Measuring range: ±0.5g / ±1g / ±2g / ±4g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Temp./humidity/air-pressure for EtherSens
Measuring range: Temperature: -40 ...+85°C Humidity: 0...100% relative Feuchte Pressure: 300...1100 hPa 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Segment-display for EtherSens
4 Digit 14 segment-display WHITE 0,56" high in wall-mounting case 5V DC supply (from I2C-interfaceport) I2C-connection
plus VAT. and shipping
Extension with ext. galv. separated I2C 3.3V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W
plus VAT. and shipping
Extension RS485-IO
Extensionboard for EtherSens-devices V1.0 for RS485 Power consumption: 2W
plus VAT. and shipping
Extension TTY-IO
Extensionboard for EtherSens-devices V1.0 for TTY (incl. 2x current-sources) Power consumption: 2W
plus VAT. and shipping
Extension Digital-IO
Extension-board for EtherSens-devices 12 x digital IN or OUT 24VDC 400mA free config with software Power consumption: 4W
plus VAT. and shipping
Extension 24V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 24V DC 4 x relay-OUT 230VAC/16A Power consumption: 4W
plus VAT. and shipping
Extension 230V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 230V AC 4 x relay-OUT 230VAC/16A Power consumption: 2,5W
plus VAT. and shipping
Power-supply-rack-unit 230V
Input voltage: 100 - 240VAC 50-60Hz Output voltage: 24V DC Power: 4W
plus VAT. and shipping
Extension Analog-IO V1.1
Extension-board for EtherSens-devices 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Extension RS422-IO
Extensionboard for EtherSens-devices V1.0 for RS422 (4-wire) Power consumption: 2W
plus VAT. and shipping
Extension RS232-IO
Extensionboard for EtherSens-devices V1.0 for RS232 (RxD, TxD) Power consumption: 2W
plus VAT. and shipping
Extension USB-port
USB-port for EtherSens-devices (data storage) Extension for: - DB-backup/restoure-function - CSV-recording Maximum current: 200mA for 5V DC
plus VAT. and shipping
accessories:
plus VAT. and shipping
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
EtherSens
Collect energy data +++ Log energy data +++ PLC fault message dispatch +++ PLC data logging/saving +++ Implement control tasks +++ Configuration via webinterface
Capture Dig/Analog-IO +++ Log Dig/Analog-IO +++ PLC fault message-dispatch +++ PLC-data logging/saving +++ implement control-tasks +++ Datalogger with web-server +++ Digital/analogue onboard-IO
Capture of gas-values +++ Monitor of gas-values +++ PLC-fault messaging +++ PLC-data logging/saving +++ Convert control tasks
load studies +++ energy checks +++ collect energy data +++ Log energy data +++ PLC fault message dispatch +++ PLC-data logging/saving +++ implement control-tasks +++ EN50470-1 / EN50470-3
Error messaging
Long distance report- and information systems in 2G-net
Long distance report- and information systems in 3G-net
plus VAT. and shipping
plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping
Extension LTE-modem
LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
plus VAT. and shipping
Extension with ext. galv. separated I2C 3.3V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W