Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1

PC 9pins COM-port <=> PLC 15pins X4/X5 port

Novelty:
Variant with integrated access-protection LAN <=> bus-side as well as output of diagnostic-buffer in web-site

Networking of SIMATIC S7-PLCs (S7-200/300/400) without Ethernet-CP/CP-communicationprocessor standard-TCP/IP without changes to the hardware-configuration or PLC-program.
Compact and robust Ethernet-converter (MPI / PROFIBUS / PPI - Ethernet).
Similar to "IBH Link S7++" (IBH-Link-S7-PP, 20266), "NETLink PRO Compact", "ACCON-NetLink-PRO compact" or "NL 50-MPI".
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET function.
By plugging the module onto the PPI, MPI or Profibus, this connection becomes an Ethernet port for the Industrial IoT with significant cost savings.
Thanks to the integrated multiplexer, this connection becomes a port for all supported protocols. Simultaneous and parallel communications such as WinCC, PUT/GET from S7 PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step7, TIA Portal or PG2000.

Advantages:

more...
variants:

69,00 € plus VAT. and shipping

ARTNR: 9359
PG-COM-cable 3m
EAN number: 4260363240185
HS-code: 85444290
Weight: 0.2 kg



S5

device type
S5-90U
x
+ext. 24V
+ext. 24V
x
x
x
S5-95U
x
+ext. 24V
+ext. 24V
x
x
x
S5-100U
x
+ext. 24V(3)
+ext. 24V
x
x
x
S5-115U
at 944 + 9359-8
at 944 + 9359-8 + ext. 24V (4)
x
x
x
x
S5-135U
at 928B + 9359-8
at 928B + 9359-8 +ext. 24V (6)
x
x
x
x
S5-155U
x
x
x
x
x
x
S5-AG110S
+9359-5-150 + 9359-4
+ ext. 24V (3)
+9359-5-150 + ext. 24V
S5-AG130W/B
+9359-5-150 + 9359-4
+ ext. 24V (3)
+9359-5-150 + ext. 24V
S5-AG150A/K/S/U
+9359-5-150 + 9359-4
+ ext. 24V (3)
+9359-5-150 + ext. 24V
CP-143
x
x
x
CP-521
+CP521 adapter
       
+CP521 adapter(1)
CP-523
+CP523 adapter
       
+CP523 adapter(1)
CP-525      
+9359-5(1)
CP-526
x
   
x
 
x
CP-527
x
   
x
 
x
CP-528
x
   
x
 
x
CP-544
x (7)
   
x (7)
 
x (7)
CP-5430
x
   
x
 
x
CP-5431
x
   
 
IP-246
x
   
x
 
x
IP-247
x
   
x
 
x
IP-252
x
   
x
 
x
IP-266
 
x
+9359-4(1)
WF-470
SIN-805
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
+9359-6(1)
SIN-820
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
+9359-6(1)
SIN-840
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
+9359-6(1)
SIN-850
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
+9359-6(1)
SIN-880
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
 
+9359-6(1)
Connection on PC
RS232-port
Ethernet RJ45
Ethernet RJ45 / WLAN/WIFI
USB-port type A
RS232-port
RS232-port
max. prolongation: 300m (UNI-extension) 300m (S5-LAN-extension) +ext. 24V 100m (PG-USB-extension)   300m (UNI-extension)

(1) ISO adapter can not be used because the required supply voltage on the PG interface of the module is not present.
(2) At the CPU 6ES5 102-8MA02 Release 3 is a PG-ISO-Adapter or Netz-Adapter additional required.
(3) With S5-LAN++ from HW V2.3 [2010] the "Netz-Adapter" is no more needed, this version has included current-sources.
(4) With S5-LAN++ from HW V2.3 [2010] no accessories are needed, this version has included current-sources.
(5) With S5-LAN++ from HW V2.3 [2010] the Sinum-Adapter 9359-6-USB is needed.
(6) Only for CPU928B with PG-ISO-Adapter and ext. 24V DC, unless there is an S5-LAN++ from HW V2.3 [2010] used.
(7) CP544 has bolts at the programming-interface. The products do not fit 100% on this interface.
(8) With S5-BRIDGE the Sinum-Adapter 9359-6-USB is needed.

DCOS IGA Automation GmbH
Plauen
www.iga-plauen.de

Wöhrle Belgium B.V.B.A.
Mechelen , Belgium
www.wohrle.be

Junger GmbH
Gütersloh
www.junger-gmbh.de
Novelty:
Variant with integrated access-protection LAN <=> bus-side as well as output of diagnostic-buffer in web-site

Networking of SIMATIC S7-PLCs (S7-200/300/400) without Ethernet-CP/CP-communicationprocessor standard-TCP/IP without changes to the hardware-configuration or PLC-program.
Compact and robust Ethernet-converter (MPI / PROFIBUS / PPI - Ethernet).
Similar to "IBH Link S7++" (IBH-Link-S7-PP, 20266), "NETLink PRO Compact", "ACCON-NetLink-PRO compact" or "NL 50-MPI".
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET function.
By plugging the module onto the PPI, MPI or Profibus, this connection becomes an Ethernet port for the Industrial IoT with significant cost savings.
Thanks to the integrated multiplexer, this connection becomes a port for all supported protocols. Simultaneous and parallel communications such as WinCC, PUT/GET from S7 PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step7, TIA Portal or PG2000.

Advantages:
  • Simple and fast networking
  • Multiplexer for all protocols
  • Integration as S7 controller with CP 343-1
  • Access to S7 data via S7-TCP/IP with PUT/GET
  • Module search without "annoying" network-card-selection
  • Free virtual-com-port for non-Step7-applications
  • Qualified support
  • Comprehensive documentation
  • No SimaticNet required for operation/configuration
  • STEP7 64-bit support
  • Integration into the TIA-Portal
  • Supports DHCP

Connectivity:
  • S7-LAN module directly connected to the PC/device with a patch cable
  • S7-LAN module directly connected to the PC/device with a crosslink cable
  • S7-LAN connected to the PC/device via a switch or hub

Features:
  • every SIMATIC-S7 (S7-200/300/400) into Network
  • SIMATIC S7-protocols (S7Comm and ISO-on-TCP (RFC 1006))
  • Ethernet-RJ45 socket with 10/100 MBit/s with autonegotiation
  • Commissioning is very simple: plug it into the PPI, MPI-bus or PROFIBUS of the SIMATIC S7 controller and start working
  • Integrated multiplexer (visualization, programming, remote maintenance and simultaneous use of all protocols without special configuration), also via standard router
  • Parallel use of the channels (simultaneously 8 x channels for programming, visualization and remote maintenance can be used directly/routed)
  • Supported controllers (S7-200, S7-300, S7-400, FM modules, Sinamix, Sinumerik, MicroMaster and other drives/converters (such as SEW-EURODRIVE converters)
  • Supported data areas (inputs, outputs, markers, data blocks, timers and counters)
  • Supported scenarios (programming adapter for S7 programming packages, access to the S7 data via S7-TCP/IP with PUT/GET and routing of SIMATIC S7 controllers as well as time server for time and also bus diagnostics)
  • Supported platforms (S7-TCPIP RFC1006 communication platform-independent, communication driver/configuration tool TIC for Windows XP, Win7/8/10/11)
  • Replacement for CP343-1/443-1 or IE/PB-Link, connected directly to MPI or Profibus (inexpensive)
  • with Profibus for S7-300 faster than CP343-1
  • PG/PC-adapter for Simatic-Manager Step7 and TIA-portal
  • fastest installation into Network (less than 3 minutes)
  • automatic detection of baudrate
  • automatic usement of cyclic bus-parameter-protocols
  • no bus-knowledge required / automatic-protocol and baud-rate detection
  • download TIC-driver for STEP-7/TIA-Portal
  • Programming and visualization at the same time (8 S7-connections (direct / routed) at the same time)
  • compatible to S7-TCP/IP RFC1006, WinCC (flex), OPC UA with Universal communication Industry 4.0, the IP-S7LINK SDK as well as all common OPC-servers
  • no HW-Config change necessary
  • no change of PLC-software necessary
  • including Classic OPC-DA-Server-lite (max. 100 variables)
  • with PG-diagnostic-port (occupied slot with 9pin PG-port free again)
  • DPV1-master of class 2 and supports all functions that a PG supports:
    • Diagnosis, configuration and programming of controllers (via software such as Simatic-Manager, TIA-Portal)
    • Diagnosis and configuration of DP-slaves (via software such as Starter)
  • active module, no influencing other bus users in the system
  • active PUT/GET (in module integrated) replaces expensive CP´s for PLC-couplings
  • Supply from S7-PLC or 24V DC external
  • CE/EMC compliant design
  • Scope of delivery (TIC driver, module itself and quick start guide)
  • Search for modules across all Network-cards (no Network-card-selection as with other providers)
  • Variable status in web interface
  • RFC1006 connection status
  • PLC-time via PG-protocol
  • TCPIP-device writes/reads DB in S7-PLC
  • Bus-diagnostics (output of error-counters, spikes)
  • RFC1006 for S7-200 (1. Generation)
  • virtual COM-port-driver for other serial S7-applications
  • Standard HMI-applications can read/write data via RFC1006 and the module


Applications:

  • Operational data collection, SCADA of non-networkable controllers
  • KTP-panel to S7-PLC with MPI-/Profibus-interface
  • PUT/GET from S7-1500/1200/300/400 (PN-CPU or with ethernet-CP) with specified and unspecified connection
  • VPN(Virtual Private Network)-remote-maintenance, maintenance of the PLC via the Internet
  • cyclic time reading from NTP-server and setting in the connected PLC
  • coupling with DB-transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or also S5-Gateway
  • any TCP-device writes/reads DBs in the S7-300/400 controller
  • monitor variables in the WebServer without a Step7 programming-package
  • analysis option of the connected bus-system with spikes- and errors-counter
  • Parameterization of field devices and drives (DPV1)
  • With IP-S7-Link-DLL high-level languages-access
  • PLC-PLC-communication (regardless of subnet boundaries, prolongation MPI/DP-bus over network)

TIC-(Totally Integrated Communication)-driver for Step7/TIA-Portal for Win XP/VISTA/7/8/10/11 32/64 Bit:
TIC firmware / configuration-tool / Step7-/TIA-driver

Product overview:

S7-LAN is a reliable and handy S7-network-adapter for PPI-,MPI- and PROFIBUS. Designed for 24/7-operation. The compact design in the PROFIBUS-connector-case and the power supply directly from the MPI/DP-port of the CPU allow to be connected a PLC to the network in less than 3 minutes.
bus protocols/bus profile, incl. baudrate and HSA are recognized independently and automatically and configured.
HMI-devices, for e.g. actual panel-series, as well as any other S7-Ethernet device, direct connect per S7-TCP-IP.
With TIC-driver (configurations-tool and driver) from download-area without changes on the project of Siemens TIA, Simatic Step7 Manager and WinCC-projects communication.
Another advantage is the easy handling of the S7-LAN. The convenient configuration is carried out directly in STEP7 or the PG/PC-interface-dialog. The detection of whether the S7-LAN is connected to a 10 MBit or 100 MBit network takes place automatically. Power is supplied directly from the MPI / DP interface. The connection to passive participants or VIPA-PLC is possible via the integrated 24V-plug.
The S7-LAN is connected to the bus-socket of the PLC and via the hub or directly to the PC. Then install the TIC-driver on the PC. Assign the IP-address with the TIC-configuration-program and go ONLINE. The installation process is completed so quickly.

Configuration:

S7-LAN is designed for quick commissioning. After the module has been plugged into the bus or externally supplied with 24V DC, only an IP address is assigned via the TIC-driver or directly via the Web-interface . The controllers can then be accessed from the network.
With the TIC-driver, there is no need for any additional installation outside of the Siemens world. The configuration takes place directly in the PG-PC interface settings and is therefore optimally integrated. Any network device that speaks S7-TCP/IP RFC1006, such as HMI-devices or PGs, can access the module directly.
In the S7-project itself, the adapter can be integrated using a placeholder entry. This is not a must, operation without project change is possible immediately. The S7-communication runs directly via S7-TCP/IP and expands each MPI-/PROFIBUS with a network gateway. It doesn't matter which control types (S7-200 / S7-300 / S7-400) are connected to the fieldbus of the PLC network.
Serial communication with S5-PLC (CPU-assemblies 15pin)
Produkbild
S5-PLC communication from PC with serial COM-port and your programming package?
PG-Com-cable up to a length of 15m are the appropriate interface-product. Without special accessories, without external supply, plugged on PC and S5 PLC and work immediately. Connection with original Siemens-sliding-locking to S5-PLC, with screw-bolts on the PC. Function with S5-90U to S5-155U. Connection PLC-side 15pin, PC 9pin (adaptation to 25pin at any time possible).
Supply voltage: 5V DC
Power consumption: 0,2 watt
Display: -
Interfaces:
to the PLC:
TTY/20mA current loop (PG-COM passiv, PLC aktiv)
to the PD/PC:
RS232: 9,6 KBd - 115,2 KBd
Operating temperature: 0 - 55°C
Case: plastic case
Dimensions: 47 x 40 x 15 mm
 
Scope of delivery: PG-COM-cable
All prices plus costs of delivery, shipping insurance and VAT.

accessories:

9310
Additional charge 25-pins PC-plug
Special construction of the RS232-side with 25pin D-Sub female with screwing locks
Quickbestellung INFOMAIL
by e-mail
39,00 €
plus VAT. and shipping


9310-M
Additional charge 25-pins PC-plug in metallized case
Special construction of the RS232-side with 25pin D-Sub female with screwing locks in metallized case
Quickbestellung INFOMAIL
by e-mail
77,00 €
plus VAT. and shipping


9359.X
Special length: PG-COM-cable (3m) + 9390
PC 9pins COM-port <=> PLC 15pins X4/X5 port
Quickbestellung INFOMAIL
by e-mail
81,00 €
plus VAT. and shipping


9390
Additional charge for special length
for S5-Interface cables per Meter 3,- Euro
Quickbestellung INFOMAIL
by e-mail
3,00 €
plus VAT. and shipping


9359-SON
Additional charge for special wiring
PG-COM/ PG-UNI/ PG-UNI-II
Quickbestellung INFOMAIL
by e-mail
10,00 €
plus VAT. and shipping


All prices plus costs of delivery, shipping insurance and VAT.

9359
PG-COM-cable 3m

PC 9pins COM-port <=> PLC 15pins X4/X5 port
Quickbestellung INFOMAIL
by e-mail
69,00 €
plus VAT. and shipping




maximum 3 articles
9359.05M
PG-COM-cable 5m

PC 9pins COM-port <=> PLC 15pins X4/X5 port
Quickbestellung INFOMAIL
by e-mail
77,00 €
plus VAT. and shipping




maximum 3 articles
9359.10M
PG-COM-cable 10m

PC 9pins COM-port <=> PLC 15pins X4/X5 port
Quickbestellung INFOMAIL
by e-mail
96,00 €
plus VAT. and shipping




maximum 3 articles
9359.15M
PG-COM-cable 15m

PC 9pins COM-port <=> PLC 15pins X4/X5 port
Quickbestellung INFOMAIL
by e-mail
113,00 €
plus VAT. and shipping




maximum 3 articles
9359.10CM
PG-COM-cable 0.1m special length

PC 9pins COM-port <=> PLC 15pins X4/X5 port
Quickbestellung INFOMAIL
by e-mail
69,00 €
plus VAT. and shipping




maximum 3 articles
9359 LAUER
PG-COM-cable with 9pin plug
special design for LAUER-devices
Quickbestellung INFOMAIL
by e-mail
69,00 €
plus VAT. and shipping


All prices plus costs of delivery, shipping insurance and VAT.

9359-1
PG-USB-cable 3m for Siemens S5 Controller

for PLC's + LED + metal case
Quickbestellung INFOMAIL
by e-mail
145,00 €
plus VAT. and shipping


9359-LAN
S5-LAN++

Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
Quickbestellung INFOMAIL
by e-mail
452,00 €
plus VAT. and shipping


9352-LANCON
S7-LAN connector for Siemens S7 PLC controller

Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
Quickbestellung INFOMAIL
by e-mail
423,00 €
plus VAT. and shipping


9359-1.05M
PG-USB-cable 5m for Siemens S5 Controller

for PLC's + LED + metal case
Quickbestellung INFOMAIL
by e-mail
174,00 €
plus VAT. and shipping


Automatic-mode

Main downloads

Versionstory

Other downloads

Support-videos