S7-LAN connector for Siemens S7 PLC controller - Process Informatik Entwicklungsgesellschaft mbH

S7-LAN connector for Siemens S7 PLC controller


Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1

Communication with 3964/9364R-client with
S7-TCPIP
inclusive adapter cable
(15pin female <=> 9pin male)

Novelty:
Variant with integrated access-protection LAN <=> bus-side as well as output of diagnostic-buffer in web-site

Networking of SIMATIC S7-PLCs (S7-200/300/400) without Ethernet-CP/CP-communicationprocessor standard-TCP/IP without changes to the hardware-configuration or PLC-program.
Compact and robust Ethernet-converter (MPI / PROFIBUS / PPI - Ethernet).
Similar to "IBH Link S7++" (IBH-Link-S7-PP, 20266), "NETLink PRO Compact", "ACCON-NetLink-PRO compact" or "NL 50-MPI".
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET function.
By plugging the module onto the PPI, MPI or Profibus, this connection becomes an Ethernet port for the Industrial IoT with significant cost savings.
Thanks to the integrated multiplexer, this connection becomes a port for all supported protocols. Simultaneous and parallel communications such as WinCC, PUT/GET from S7 PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step7, TIA Portal or PG2000.

Advantages:

more...
variants:

971,00 € plus VAT. and shipping

ARTNR: 9359-RK-RS
S5-3964R-LAN RS232-version
EAN number: 4260363243889
HS-code: 85444290
Weight: 0.1 kg



Novelty:
Variant with integrated access-protection LAN <=> bus-side as well as output of diagnostic-buffer in web-site

Networking of SIMATIC S7-PLCs (S7-200/300/400) without Ethernet-CP/CP-communicationprocessor standard-TCP/IP without changes to the hardware-configuration or PLC-program.
Compact and robust Ethernet-converter (MPI / PROFIBUS / PPI - Ethernet).
Similar to "IBH Link S7++" (IBH-Link-S7-PP, 20266), "NETLink PRO Compact", "ACCON-NetLink-PRO compact" or "NL 50-MPI".
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET function.
By plugging the module onto the PPI, MPI or Profibus, this connection becomes an Ethernet port for the Industrial IoT with significant cost savings.
Thanks to the integrated multiplexer, this connection becomes a port for all supported protocols. Simultaneous and parallel communications such as WinCC, PUT/GET from S7 PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step7, TIA Portal or PG2000.

Advantages:
  • Simple and fast networking
  • Multiplexer for all protocols
  • Integration as S7 controller with CP 343-1
  • Access to S7 data via S7-TCP/IP with PUT/GET
  • Module search without "annoying" network-card-selection
  • Free virtual-com-port for non-Step7-applications
  • Qualified support
  • Comprehensive documentation
  • No SimaticNet required for operation/configuration
  • STEP7 64-bit support
  • Integration into the TIA-Portal
  • Supports DHCP

Connectivity:
  • S7-LAN module directly connected to the PC/device with a patch cable
  • S7-LAN module directly connected to the PC/device with a crosslink cable
  • S7-LAN connected to the PC/device via a switch or hub

Features:
  • every SIMATIC-S7 (S7-200/300/400) into Network
  • SIMATIC S7-protocols (S7Comm and ISO-on-TCP (RFC 1006))
  • Ethernet-RJ45 socket with 10/100 MBit/s with autonegotiation
  • Commissioning is very simple: plug it into the PPI, MPI-bus or PROFIBUS of the SIMATIC S7 controller and start working
  • Integrated multiplexer (visualization, programming, remote maintenance and simultaneous use of all protocols without special configuration), also via standard router
  • Parallel use of the channels (simultaneously 8 x channels for programming, visualization and remote maintenance can be used directly/routed)
  • Supported controllers (S7-200, S7-300, S7-400, FM modules, Sinamix, Sinumerik, MicroMaster and other drives/converters (such as SEW-EURODRIVE converters)
  • Supported data areas (inputs, outputs, markers, data blocks, timers and counters)
  • Supported scenarios (programming adapter for S7 programming packages, access to the S7 data via S7-TCP/IP with PUT/GET and routing of SIMATIC S7 controllers as well as time server for time and also bus diagnostics)
  • Supported platforms (S7-TCPIP RFC1006 communication platform-independent, communication driver/configuration tool TIC for Windows XP, Win7/8/10/11)
  • Replacement for CP343-1/443-1 or IE/PB-Link, connected directly to MPI or Profibus (inexpensive)
  • with Profibus for S7-300 faster than CP343-1
  • PG/PC-adapter for Simatic-Manager Step7 and TIA-portal
  • fastest installation into Network (less than 3 minutes)
  • automatic detection of baudrate
  • automatic usement of cyclic bus-parameter-protocols
  • no bus-knowledge required / automatic-protocol and baud-rate detection
  • download TIC-driver for STEP-7/TIA-Portal
  • Programming and visualization at the same time (8 S7-connections (direct / routed) at the same time)
  • compatible to S7-TCP/IP RFC1006, WinCC (flex), OPC UA with Universal communication Industry 4.0, the IP-S7LINK SDK as well as all common OPC-servers
  • no HW-Config change necessary
  • no change of PLC-software necessary
  • including Classic OPC-DA-Server-lite (max. 100 variables)
  • with PG-diagnostic-port (occupied slot with 9pin PG-port free again)
  • DPV1-master of class 2 and supports all functions that a PG supports:
    • Diagnosis, configuration and programming of controllers (via software such as Simatic-Manager, TIA-Portal)
    • Diagnosis and configuration of DP-slaves (via software such as Starter)
  • active module, no influencing other bus users in the system
  • active PUT/GET (in module integrated) replaces expensive CP´s for PLC-couplings
  • Supply from S7-PLC or 24V DC external
  • CE/EMC compliant design
  • Scope of delivery (TIC driver, module itself and quick start guide)
  • Search for modules across all Network-cards (no Network-card-selection as with other providers)
  • Variable status in web interface
  • RFC1006 connection status
  • PLC-time via PG-protocol
  • TCPIP-device writes/reads DB in S7-PLC
  • Bus-diagnostics (output of error-counters, spikes)
  • RFC1006 for S7-200 (1. Generation)
  • virtual COM-port-driver for other serial S7-applications
  • Standard HMI-applications can read/write data via RFC1006 and the module


Applications:

  • Operational data collection, SCADA of non-networkable controllers
  • KTP-panel to S7-PLC with MPI-/Profibus-interface
  • PUT/GET from S7-1500/1200/300/400 (PN-CPU or with ethernet-CP) with specified and unspecified connection
  • VPN(Virtual Private Network)-remote-maintenance, maintenance of the PLC via the Internet
  • cyclic time reading from NTP-server and setting in the connected PLC
  • coupling with DB-transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or also S5-Gateway
  • any TCP-device writes/reads DBs in the S7-300/400 controller
  • monitor variables in the WebServer without a Step7 programming-package
  • analysis option of the connected bus-system with spikes- and errors-counter
  • Parameterization of field devices and drives (DPV1)
  • With IP-S7-Link-DLL high-level languages-access
  • PLC-PLC-communication (regardless of subnet boundaries, prolongation MPI/DP-bus over network)

TIC-(Totally Integrated Communication)-driver for Step7/TIA-Portal for Win XP/VISTA/7/8/10/11 32/64 Bit:
TIC firmware / configuration-tool / Step7-/TIA-driver

Product overview:

S7-LAN is a reliable and handy S7-network-adapter for PPI-,MPI- and PROFIBUS. Designed for 24/7-operation. The compact design in the PROFIBUS-connector-case and the power supply directly from the MPI/DP-port of the CPU allow to be connected a PLC to the network in less than 3 minutes.
bus protocols/bus profile, incl. baudrate and HSA are recognized independently and automatically and configured.
HMI-devices, for e.g. actual panel-series, as well as any other S7-Ethernet device, direct connect per S7-TCP-IP.
With TIC-driver (configurations-tool and driver) from download-area without changes on the project of Siemens TIA, Simatic Step7 Manager and WinCC-projects communication.
Another advantage is the easy handling of the S7-LAN. The convenient configuration is carried out directly in STEP7 or the PG/PC-interface-dialog. The detection of whether the S7-LAN is connected to a 10 MBit or 100 MBit network takes place automatically. Power is supplied directly from the MPI / DP interface. The connection to passive participants or VIPA-PLC is possible via the integrated 24V-plug.
The S7-LAN is connected to the bus-socket of the PLC and via the hub or directly to the PC. Then install the TIC-driver on the PC. Assign the IP-address with the TIC-configuration-program and go ONLINE. The installation process is completed so quickly.

Configuration:

S7-LAN is designed for quick commissioning. After the module has been plugged into the bus or externally supplied with 24V DC, only an IP address is assigned via the TIC-driver or directly via the Web-interface . The controllers can then be accessed from the network.
With the TIC-driver, there is no need for any additional installation outside of the Siemens world. The configuration takes place directly in the PG-PC interface settings and is therefore optimally integrated. Any network device that speaks S7-TCP/IP RFC1006, such as HMI-devices or PGs, can access the module directly.
In the S7-project itself, the adapter can be integrated using a placeholder entry. This is not a must, operation without project change is possible immediately. The S7-communication runs directly via S7-TCP/IP and expands each MPI-/PROFIBUS with a network gateway. It doesn't matter which control types (S7-200 / S7-300 / S7-400) are connected to the fieldbus of the PLC network.
Visualisation via 3964R-interface without using the protocol itself
Produkbild
Your visualisation-software does not support a 3964R-protocol, but you have to apply this package? No problem, connect the 3964R-LAN to your CP and activate the RFC1006-emulation in the module. Now your software gets the data from the module via RFC1006, which in turn communicates with the assembly via 3964R.
Extension of a 3964R-line via LAN
Produkbild
There is a control with CP524 in your outstation and the communication partner of the CP has moved locally. Connecting path is a LAN-network. So each of both participants gets a 3964R-LAN and after input of the partner’s IP-address a coupling via LAN will be configured.
PLC coupling (data exchange between PLC’s)
Produkbild
Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Therefore no dedicated line is required, it’s sufficient when the stations connect via network (DSL-router).

Produkbild

With the S5-H1-PG-LAN you would be able to use the H1-path-selection over the S5-LAN++ and communicate with all PLCs in the H1-bus. You don´t have to connect serial to the CP, you can do this easy over your network.

Remote maintenance of your S5-PLC via LAN / Internet
Produkbild
You have access to a on-site network and your PLC has no LAN-connection? No problem, plug the S5-LAN on the PLC and you will have immediate access to the PLC from afar.
Programming of S5-PLC’s via LAN
Produkbild
You would like to respond to your S5-PLC via LAN, but not integrate an Ethernet-CP? No problem, plug the S5-LAN++ on the PD-interface and access via LAN.
Communication with Win98 – XP/Vista/7/8/10/11 via network to S5-PLC
Produkbild
You still have a PC with Win98 and a MS-DOS-based Step5-package and would like to go Online on your S5-PLC via LAN? No problem, the provided virtual Com-Port PLCVCom emulates a COM-port on your PC with which you go Online. Even your MS-DOS-based Step5-software on this WIN98-PC can use this virtual Com-Port. With a patchtool for the Siemens Step5-software, which is provided as well, nothing else stands in your way to communicate via LAN.
Watching of S5- PLC’s with panel for S7-PLC
Produkbild
Your panel only has a LAN-socket as PLC-interface and supports only S7-RFC1006, no problem. Connect this socket with the S5-LAN++ and plug it directly on the PD-interface of the PLC. The S5-LAN++ performs adverse your panel as a S7-PLC although you receive the data from the S5-PLC. Then access to the variables and data of the S5-PLC is already available.
Watching of S5-PLC’s via LAN without Ethernet-CP
Produkbild
Your panel only has a LAN-socket as PLC-interface, no problem. Connect this socket with the S5-LAN++ and plug it directly on the PD-interface of the PLC. Then access to the variables and data of the PLC is already available.
Supply voltage: 24V DC +/- 20%
Power consumption: 2 watt
Display: status-LED
Handling/Configuration: reset-switch-key (factory setting)
S5-LAN Manager
Interfaces:
to the PLC:
RS232 TxD, RxD and GND
to the PD/PC:
10/100BaseTX RJ45-ethernet jack
Operating system: Configuration and operation via virtual COM-interface: MS-Windows XP/2000/7/8/10/11/Server
Operation via TCP/IP server: any operating system with a TCP/IP stack
Operating temperature: 0 - 55°C
Case: ABS-plastic case
Dimensions: 42 x 15 x 65 mm
 
Scope of delivery: S5-LAN++-module
Power connector 2pins small
All prices plus costs of delivery, shipping insurance and VAT.

accessories:

9391.1
24V DC power-supply unit 625mA

Primary 110V - 240 VAC Euro+USA-plug
Quickbestellung INFOMAIL
by e-mail
59,00 €
plus VAT. and shipping


9636-TCPIP.1M
Patch-cable 1m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
Quickbestellung INFOMAIL
by e-mail
15,00 €
plus VAT. and shipping


9636-CROSS
Cross-cable 3m Cat5+, shielded

RJ45 plug <=> RJ45 plug, twisted pinning
9636-TCPIP
Patch-cable 3m, Cat5+, shielded

RJ45 plug <=> RJ45 plug, 1:1
9352-24
Power connector 2pins small

cable coupling by screw-connector (small)
Quickbestellung INFOMAIL
by e-mail
4,00 €
plus VAT. and shipping


9391-USB
USB-powercable for 24V DC, max. 3W

USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
Quickbestellung INFOMAIL
by e-mail
95,00 €
plus VAT. and shipping


All prices plus costs of delivery, shipping insurance and VAT.

9359-RK-RS
S5-3964R-LAN RS232-version

Communication with 3964/9364R-client with S7-TCPIP inclusive adapter cable (15pin female <=> 9pin male)
Quickbestellung INFOMAIL
by e-mail
971,00 €
plus VAT. and shipping




maximum 3 articles
9359-LAN
S5-LAN++

Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
Quickbestellung INFOMAIL
by e-mail
452,00 €
plus VAT. and shipping




maximum 3 articles
9359-PG-LAN
S5-PG-LAN

RS232-complement to S5-LAN++ (TTY/RS232)
Quickbestellung INFOMAIL
by e-mail
924,00 €
plus VAT. and shipping




maximum 3 articles
9359-LAN-RS
S5-LAN++ RS232-version

Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
Quickbestellung INFOMAIL
by e-mail
555,00 €
plus VAT. and shipping




maximum 3 articles
9359-RK
S5-3964R-LAN

Communication with 3964/9364R-client with S7-TCPIP Cable-adapter optional
Quickbestellung INFOMAIL
by e-mail
866,00 €
plus VAT. and shipping




maximum 3 articles
9359-ASCII
S5-ASCII-LAN

sends ASCII-data via Industrial Ethernet
Quickbestellung INFOMAIL
by e-mail
567,00 €
plus VAT. and shipping




maximum 3 articles
9359-H1-PG-LAN
S5-H1-PG-LAN

Supports Step5 SoftNet-communication direct to S5-PLCs
Quickbestellung INFOMAIL
by e-mail
693,00 €
plus VAT. and shipping




maximum 3 articles
9359-LAN-PATH
S5-LAN with path-selection promotion

Promotes the path-selection of the Step5-software
Quickbestellung INFOMAIL
by e-mail
2185,00 €
plus VAT. and shipping




maximum 3 articles

All prices plus costs of delivery, shipping insurance and VAT.

9359-LAN-RS
S5-LAN++ RS232-version

Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
Quickbestellung INFOMAIL
by e-mail
555,00 €
plus VAT. and shipping


9391.1
24V DC power-supply unit 625mA

Primary 110V - 240 VAC Euro+USA-plug
Quickbestellung INFOMAIL
by e-mail
59,00 €
plus VAT. and shipping


9352-LANCON
S7-LAN connector for Siemens S7 PLC controller

Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
Quickbestellung INFOMAIL
by e-mail
423,00 €
plus VAT. and shipping


9352-ALF-UA
ALF-UA high-speed WIFI-Router for Din-Rail-mounting Obsolete

Successor: CONNECT-Router for Din-Rail-mounting (Art.No: 9354-CONNECT-HS-ROUTER)
Industrial WIFI-Router for Unified Access Integrated USB-port Basic-plattform, functionality with software-options expandable One-click mounting
Quickbestellung INFOMAIL
by e-mail
0,00 €
plus VAT. and shipping