Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK
S7-LAN connector for Siemens S7 PLC controller - Process Informatik Entwicklungsgesellschaft mbH

S7-LAN connector for Siemens S7 PLC controller Download


Successor: FLASH-PROMMER-II-MMC 24VDC (Art.No: 9363-8-MMC)

Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1

for S5/S7 memory-modules, Win7-support
for S5D-, S7P- and binary-files

Novelty:
Variant with integrated access-protection LAN <=> bus-side as well as output of diagnostic-buffer in web-site

Networking of SIMATIC S7-PLCs (S7-200/300/400) without Ethernet-CP/CP-communicationprocessor standard-TCP/IP without changes to the hardware-configuration or PLC-program.
Compact and robust Ethernet-converter (MPI / PROFIBUS / PPI - Ethernet).
Similar to "IBH Link S7++" (IBH-Link-S7-PP, 20266), "NETLink PRO Compact", "ACCON-NetLink-PRO compact" or "NL 50-MPI".
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET function.
By plugging the module onto the PPI, MPI or Profibus, this connection becomes an Ethernet port for the Industrial IoT with significant cost savings.
Thanks to the integrated multiplexer, this connection becomes a port for all supported protocols. Simultaneous and parallel communications such as WinCC, PUT/GET from S7 PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step7, TIA Portal or PG2000.

Advantages:

more...

ARTNR: 9363-2
MULTI-PROMMER programming device
Obsolete
EAN number: 4260363240758
HS-code: 85389099
Weight: 2.2 kg


Memory modules / Prommer

  Mini-Prommer-III
Mini-Prommer-III
Flash-Prommer-II-MMC
Flash-Prommer-II-MMC
Multi-Prommer
Multi-Prommer
Supported formats Windows XP
(16-Bit-Version)
Windows 7
(32-Bit-Version)
Windows XP
(16-Bit-Version)
Windows 7
(32-Bit-Version)
Windows XP
(16-Bit-Version)
Windows 7
(32-Bit-Version)
Binäryfile *.BIN
Step-5 file *.S5D
Step-7 file(structur) *.S7P
S7-PLC-firmware-update (MMC)        
ET-100 files *.308
ET-200 files *ET.200
ET2-Binäryexport *.2BF
Intel-Hex-format *.HEX
Motorola-Hex-format *.EPR
CP-525/524 files *.525
CP-5431-files Q*.*
CP-1430/CP-143-files A*.*
Module type Storage type Slot  
2532 UV, NMOS DIL-Socket
27128 UV, NMOS DIL-Socket
2732A UV, NMOS DIL-Socket
2764 UV, NMOS DIL-Socket
27C010 UV, CMOS DIL-Socket
27C1001 UV, CMOS DIL-Socket
27C128 UV, CMOS DIL-Socket
2716BQ UV, CMOS DIL-Socket
27C200 UV, CMOS DIL-Socket
27C256 UV, CMOS DIL-Socket
27C400 UV, CMOS DIL-Socket
27C512 UV, CMOS DIL-Socket
27C64A UV, CMOS DIL-Socket
27C080 UV, CMOS DIL-Socket
27C801 UV, CMOS DIL-Socket
28F010 FLASH DIL-Socket
29F010 FLASH DIL-Socket
370-0AA41 UV, CMOS VG-strip ✓ (only reading) ✓ (only reading)
372-0AA51 UV, NMOS VG-strip ✓ (only reading) ✓ (only reading)
372-0AA61 UV, NMOS VG-strip ✓ (only reading) ✓ (only reading)
373-0AA21 UV, NMOS VG-strip
373-0AA41 UV, NMOS VG-strip ✓ (ab V1.5)
373-0AA61 UV, NMOS VG-strip ✓ (ab V1.5)
373-0AA81 UV, CMOS VG-strip ✓ (ab V1.5)
373-1AA41 UV, CMOS VG-strip
373-1AA61 UV, CMOS VG-strip
373-1AA81 UV, CMOS VG-strip
374-1FG11 FLASH PCMCIA ✓ (ab V3.15)
374-1FH11 FLASH PCMCIA ✓ (ab BS3.E)
374-1FH21 FLASH PCMCIA
374-1KG11 FLASH PCMCIA
374-1KJ11 FLASH PCMCIA
374-1KH21 FLASH PCMCIA
374-1KK21 FLASH PCMCIA
374-2FH21 FLASH PCMCIA
374-2KG21 FLASH PCMCIA
374-2KH21 FLASH PCMCIA
374-2KK21 FLASH PCMCIA
374-2KL21 FLASH PCMCIA
375-0LA11 UV, NMOS VG-strip
375-0LA15 UV, NMOS VG-strip
375-0LA21 UV, NMOS VG-strip
375-0LA41 UV, NMOS VG-strip
375-0LA61 UV, CMOS VG-strip ✓ (ab V1.5)
375-0LA71 UV, CMOS VG-strip
375-0LC11 EEPROM VG-strip
375-0LC15 EEPROM VG-strip
375-0LC21 EEPROM VG-strip
375-0LC31 EEPROM VG-strip
375-0LC41 EEPROM VG-strip
375-0LC61 EEPROM VG-strip
375-1LA15 UV, CMOS VG-strip
375-1LA21 UV, CMOS VG-strip
375-1LA41 UV, CMOS VG-strip ✓ (ab V1.5)
375-1LA61 UV, CMOS VG-strip
375-1LA71 UV, CMOS VG-strip
375-8LA11 UV, CMOS VG-strip
375-8LA12 FLASH VG-strip ✓ (ab V1.6)
375-8LC11 EEPROM VG-strip
375-8LC21 EEPROM VG-strip
375-TPA1 EEPROM VG-strip ✓ (ab V1.5)
376-0AA11 UV, NMOS VG-strip
376-0AA21 UV, NMOS VG-strip
376-0AA31 UV, CMOS VG-strip
376-1AA11 UV, CMOS VG-strip
376-1AA21 UV, CMOS VG-strip ✓ (ab V1.5)
376-1AA31 UV, CMOS VG-strip
6FX1126-0B
!Number has to be the same!
UV, CMOS VG-strip
6FX1128-4B
!Number has to be the same!
Don't confuse with 6FX1128-4BB10,
there is no compatibility!
UV, CMOS VG-strip
6FX1130-5B
!Number has to be the same!
UV, CMOS VG-strip
910-0AA31 UV, NMOS VG-strip ✓ (only reading) ✓ (only reading)
910-0AA41 UV, NMOS VG-strip ✓ (only reading) ✓ (only reading)
951-0FD00 FLASH PCMCIA
951-0KD00 FLASH PCMCIA
951-0KD80 FLASH PCMCIA
951-0KE00 FLASH PCMCIA
951-0KE80 FLASH PCMCIA
951-0KF00 FLASH PCMCIA
951-0KF80 FLASH PCMCIA
951-0KG00 FLASH PCMCIA
951-0KJ00 FLASH PCMCIA
951-1KH00 FLASH PCMCIA
951-1KK00 FLASH PCMCIA
951-1KM00 FLASH PCMCIA
952-0KD00 FLASH PCMCIA
952-0KE00 FLASH PCMCIA
952-0KF00 FLASH PCMCIA
952-0KG00 FLASH PCMCIA
952-0KH00 FLASH PCMCIA
952-1KK00 FLASH PCMCIA
952-1KL00 FLASH PCMCIA
952-1KM00 FLASH PCMCIA
A1SMCY_8KP UV, CMOS DIL-Socket
FX_EEPROM4 UV, CMOS DIL-Socket
FX_EPROM_8 UV, CMOS DIL-Socket

Wöhrle Belgium B.V.B.A.
Mechelen , Belgium
www.wohrle.be
Novelty:
Variant with integrated access-protection LAN <=> bus-side as well as output of diagnostic-buffer in web-site

Networking of SIMATIC S7-PLCs (S7-200/300/400) without Ethernet-CP/CP-communicationprocessor standard-TCP/IP without changes to the hardware-configuration or PLC-program.
Compact and robust Ethernet-converter (MPI / PROFIBUS / PPI - Ethernet).
Similar to "IBH Link S7++" (IBH-Link-S7-PP, 20266), "NETLink PRO Compact", "ACCON-NetLink-PRO compact" or "NL 50-MPI".
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET function.
By plugging the module onto the PPI, MPI or Profibus, this connection becomes an Ethernet port for the Industrial IoT with significant cost savings.
Thanks to the integrated multiplexer, this connection becomes a port for all supported protocols. Simultaneous and parallel communications such as WinCC, PUT/GET from S7 PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step7, TIA Portal or PG2000.

Advantages:
  • Simple and fast networking
  • Multiplexer for all protocols
  • Integration as S7 controller with CP 343-1
  • Access to S7 data via S7-TCP/IP with PUT/GET
  • Module search without "annoying" network-card-selection
  • Free virtual-com-port for non-Step7-applications
  • Qualified support
  • Comprehensive documentation
  • No SimaticNet required for operation/configuration
  • STEP7 64-bit support
  • Integration into the TIA-Portal
  • Supports DHCP

Connectivity:
  • S7-LAN module directly connected to the PC/device with a patch cable
  • S7-LAN module directly connected to the PC/device with a crosslink cable
  • S7-LAN connected to the PC/device via a switch or hub

Features:
  • every SIMATIC-S7 (S7-200/300/400) into Network
  • SIMATIC S7-protocols (S7Comm and ISO-on-TCP (RFC 1006))
  • Ethernet-RJ45 socket with 10/100 MBit/s with autonegotiation
  • Commissioning is very simple: plug it into the PPI, MPI-bus or PROFIBUS of the SIMATIC S7 controller and start working
  • Integrated multiplexer (visualization, programming, remote maintenance and simultaneous use of all protocols without special configuration), also via standard router
  • Parallel use of the channels (simultaneously 8 x channels for programming, visualization and remote maintenance can be used directly/routed)
  • Supported controllers (S7-200, S7-300, S7-400, FM modules, Sinamix, Sinumerik, MicroMaster and other drives/converters (such as SEW-EURODRIVE converters)
  • Supported data areas (inputs, outputs, markers, data blocks, timers and counters)
  • Supported scenarios (programming adapter for S7 programming packages, access to the S7 data via S7-TCP/IP with PUT/GET and routing of SIMATIC S7 controllers as well as time server for time and also bus diagnostics)
  • Supported platforms (S7-TCPIP RFC1006 communication platform-independent, communication driver/configuration tool TIC for Windows XP, Win7/8/10/11)
  • Replacement for CP343-1/443-1 or IE/PB-Link, connected directly to MPI or Profibus (inexpensive)
  • with Profibus for S7-300 faster than CP343-1
  • PG/PC-adapter for Simatic-Manager Step7 and TIA-portal
  • fastest installation into Network (less than 3 minutes)
  • automatic detection of baudrate
  • automatic usement of cyclic bus-parameter-protocols
  • no bus-knowledge required / automatic-protocol and baud-rate detection
  • download TIC-driver for STEP-7/TIA-Portal
  • Programming and visualization at the same time (8 S7-connections (direct / routed) at the same time)
  • compatible to S7-TCP/IP RFC1006, WinCC (flex), OPC UA with Universal communication Industry 4.0, the IP-S7LINK SDK as well as all common OPC-servers
  • no HW-Config change necessary
  • no change of PLC-software necessary
  • including Classic OPC-DA-Server-lite (max. 100 variables)
  • with PG-diagnostic-port (occupied slot with 9pin PG-port free again)
  • DPV1-master of class 2 and supports all functions that a PG supports:
    • Diagnosis, configuration and programming of controllers (via software such as Simatic-Manager, TIA-Portal)
    • Diagnosis and configuration of DP-slaves (via software such as Starter)
  • active module, no influencing other bus users in the system
  • active PUT/GET (in module integrated) replaces expensive CP´s for PLC-couplings
  • Supply from S7-PLC or 24V DC external
  • CE/EMC compliant design
  • Scope of delivery (TIC driver, module itself and quick start guide)
  • Search for modules across all Network-cards (no Network-card-selection as with other providers)
  • Variable status in web interface
  • RFC1006 connection status
  • PLC-time via PG-protocol
  • TCPIP-device writes/reads DB in S7-PLC
  • Bus-diagnostics (output of error-counters, spikes)
  • RFC1006 for S7-200 (1. Generation)
  • virtual COM-port-driver for other serial S7-applications
  • Standard HMI-applications can read/write data via RFC1006 and the module


Applications:

  • Operational data collection, SCADA of non-networkable controllers
  • KTP-panel to S7-PLC with MPI-/Profibus-interface
  • PUT/GET from S7-1500/1200/300/400 (PN-CPU or with ethernet-CP) with specified and unspecified connection
  • VPN(Virtual Private Network)-remote-maintenance, maintenance of the PLC via the Internet
  • cyclic time reading from NTP-server and setting in the connected PLC
  • coupling with DB-transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or also S5-Gateway
  • any TCP-device writes/reads DBs in the S7-300/400 controller
  • monitor variables in the WebServer without a Step7 programming-package
  • analysis option of the connected bus-system with spikes- and errors-counter
  • Parameterization of field devices and drives (DPV1)
  • With IP-S7-Link-DLL high-level languages-access
  • PLC-PLC-communication (regardless of subnet boundaries, prolongation MPI/DP-bus over network)

TIC-(Totally Integrated Communication)-driver for Step7/TIA-Portal for Win XP/VISTA/7/8/10/11 32/64 Bit:
TIC firmware / configuration-tool / Step7-/TIA-driver

Product overview:

S7-LAN is a reliable and handy S7-network-adapter for PPI-,MPI- and PROFIBUS. Designed for 24/7-operation. The compact design in the PROFIBUS-connector-case and the power supply directly from the MPI/DP-port of the CPU allow to be connected a PLC to the network in less than 3 minutes.
bus protocols/bus profile, incl. baudrate and HSA are recognized independently and automatically and configured.
HMI-devices, for e.g. actual panel-series, as well as any other S7-Ethernet device, direct connect per S7-TCP-IP.
With TIC-driver (configurations-tool and driver) from download-area without changes on the project of Siemens TIA, Simatic Step7 Manager and WinCC-projects communication.
Another advantage is the easy handling of the S7-LAN. The convenient configuration is carried out directly in STEP7 or the PG/PC-interface-dialog. The detection of whether the S7-LAN is connected to a 10 MBit or 100 MBit network takes place automatically. Power is supplied directly from the MPI / DP interface. The connection to passive participants or VIPA-PLC is possible via the integrated 24V-plug.
The S7-LAN is connected to the bus-socket of the PLC and via the hub or directly to the PC. Then install the TIC-driver on the PC. Assign the IP-address with the TIC-configuration-program and go ONLINE. The installation process is completed so quickly.

Configuration:

S7-LAN is designed for quick commissioning. After the module has been plugged into the bus or externally supplied with 24V DC, only an IP address is assigned via the TIC-driver or directly via the Web-interface . The controllers can then be accessed from the network.
With the TIC-driver, there is no need for any additional installation outside of the Siemens world. The configuration takes place directly in the PG-PC interface settings and is therefore optimally integrated. Any network device that speaks S7-TCP/IP RFC1006, such as HMI-devices or PGs, can access the module directly.
In the S7-project itself, the adapter can be integrated using a placeholder entry. This is not a must, operation without project change is possible immediately. The S7-communication runs directly via S7-TCP/IP and expands each MPI-/PROFIBUS with a network gateway. It doesn't matter which control types (S7-200 / S7-300 / S7-400) are connected to the fieldbus of the PLC network.
Supply voltage: 240V AC 50-60Hz (115V/AC optional)
Power consumption: 30 watt
Display: -
Handling/Configuration: WinPrommer-Software
Interfaces:
to the PD/PC:
RS232 to any COM-Port
parallel port for centronics-interface
others:
S5-memory modules
S5-/S7-FlashCards
Dual-In-Line-memory devices
24V/DV-output for UVL3
Operating temperature: 0 - 55°C
Case: powder coated metal case
Dimensions: 245 x 47 x 187 mm
 
Scope of delivery: Multi-Prommer
Power-cord
Cable 9pin 1to1
Cable 25pin 1to1
Power connector 2pins for 24V-out
All prices plus costs of delivery, shipping insurance and VAT.

accessories:

9363-11
TEXTOOL 32 DIL

Quickbestellung INFOMAIL
by e-mail
81,00 €
plus VAT. and shipping


9363-7
Servicebag

for MULTI-PROMMER
Quickbestellung INFOMAIL
by e-mail
60,00 €
plus VAT. and shipping


9363-12
Mitsubishi-adapter

Quickbestellung INFOMAIL
by e-mail
81,00 €
plus VAT. and shipping


9359.1:1
1:1 cable 9pins D-SUB

D-SUB 9pins (male) <=> D-Sub 9pins (female), 1to1-assignment
Quickbestellung INFOMAIL
by e-mail
28,00 €
plus VAT. and shipping


9363-13
PLCC32-adapter

for MULTI-Prommer
Quickbestellung INFOMAIL
by e-mail
239,00 €
plus VAT. and shipping


9363-WIN7
Upgrade WinPromm-software for 32-bit
Upgrade of WinPromm-software to 32-bit for Multi-Prommer, Mini-Prommer-III and Flash-Prommer-II/Flash-Prommer-II-MMC Provided formats: S5D, S7P and binary windows (any)
Quickbestellung INFOMAIL
by e-mail
99,00 €
plus VAT. and shipping


All prices plus costs of delivery, shipping insurance and VAT.

Memory modules / Prommer

Memory-modules
Memory-modules for SIMATIC® - S5&S7
All prices plus costs of delivery, shipping insurance and VAT.

145,00 €
plus VAT. and shipping


9363-3-B
EPROM-Eraser UVL3

24V miniature device as cap
Quickbestellung INFOMAIL
by e-mail
180,00 €
plus VAT. and shipping


9363-7
Servicebag

for MULTI-PROMMER
Quickbestellung INFOMAIL
by e-mail
60,00 €
plus VAT. and shipping


9350-9-DIAG
DiagConn 90° Highend-connector

for PROFIBUS with diagnosis function country of origin: Germany not preferential
Quickbestellung INFOMAIL
by e-mail
54,00 €
plus VAT. and shipping


9377-ANALOG-OP
TELESERVICE ANALOGUE up to 12MBaud MPI+DP
without DP V0/V1/V2
Quickbestellung INFOMAIL
by e-mail
498,00 €
plus VAT. and shipping


Automatic-mode

Other downloads

Extension

Support-videos