Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK
S7-LAN connector for Siemens S7 PLC controller - Process Informatik Entwicklungsgesellschaft mbH

S7-LAN connector for Siemens S7 PLC controller


Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1

OEM - Version (all accessories optional)
without PCMCIA-Slot for UMTS-/LAN-card

Novelty:
Variant with integrated access-protection LAN <=> bus-side as well as output of diagnostic-buffer in web-site

Networking of SIMATIC S7-PLCs (S7-200/300/400) without Ethernet-CP/CP-communicationprocessor standard-TCP/IP without changes to the hardware-configuration or PLC-program.
Compact and robust Ethernet-converter (MPI / PROFIBUS / PPI - Ethernet).
Similar to "IBH Link S7++" (IBH-Link-S7-PP, 20266), "NETLink PRO Compact", "ACCON-NetLink-PRO compact" or "NL 50-MPI".
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET function.
By plugging the module onto the PPI, MPI or Profibus, this connection becomes an Ethernet port for the Industrial IoT with significant cost savings.
Thanks to the integrated multiplexer, this connection becomes a port for all supported protocols. Simultaneous and parallel communications such as WinCC, PUT/GET from S7 PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step7, TIA Portal or PG2000.

Advantages:

more...
variants:

1260,00 € plus VAT. and shipping

ARTNR: 9372-OEM
TELE-PROFessional II worldwide use
EAN number: 4260363240062
HS-code: 85389099
Weight: 2.05 kg



Remote maintenance

TELE LINK NETWORK
         
 
secured modem-protocol
additional software needed
Siemens TS -Software
Siemens TS -Software
VPN-Client
VPN-Client
Providing WinTELEPROF-software
modem
analogue/ISDN
analogue
opt. via PCMCIA
analogue/GSM
analogue/ISDN/GSM
internet-connection
internet-connection
internet-connection
modem for world wide use
interfaces
MPI/Profibus
9600-12MBd
9600-12MBd
9600-12MBd
9600-12MBd
RS232
2x
2x
2x
1x
1x
TTY
2x
2x
2x
1x
PCMCIA
2x (optionally)
1x
1x
Ethernet
10/100BaseTx
1x
1x
5x
USB
2x
1x
LCD-display
instead 10 LEDs
instead status-LED
instead webserver
instead webserver
supported PLC-protocols *
S7
S5
✓ (optional)
✓ (optional)
Pilz PSS
✓ (optional)
✓ (optional)
Allen-Bradley
✓ (optional)
✓ (optional)
AEG
✓ (optional)
✓ (optional)
Bosch
✓ (optional)
✓ (optional)
Telemecanique
✓ (optional)
✓ (optional)
GE-Fanuc
✓ (optional)
✓ (optional)
Klöckner-Moeller
✓ (optional)
✓ (optional)
Mitsubishi
✓ (optional)
✓ (optional)
SMS-sending/Pager(S5/S7)
✓ (no pager)
only for analogue / ISDN
HMI-messaging module(S5/S7)
SMS-receive with GSM
DTMF with analogue
e-mail-dispatch
FAX-dispatch(S5/S7)
✓ (optional)
✓ (optional)
only for analogue / ISDN
PLC-data coupling(S5/S7)
✓ (optional)
✓ (optional)
ASCII-transfer from S5/S7
✓ (optional)
✓ (optional)
only with ASCII-LAN
internet-coupling
Usage as dial-up-router
power supply
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
dimensions w x h x d (in mm)
High: 67 x 280 x 170
FLAT: 300 x 175 x 70
300 x 175 x 66
235 x 162 x 37
90 x 162 x 54
40 x 125 x 115
42 x 15 x 65
65 x 43 x 17
154 x 92 x 28

* other PLC types on request

Karl Roll GmbH & Co. KG
Mühlacker - Enzberg
www.karl-roll.de

Wöhrle Belgium B.V.B.A.
Mechelen , Belgium
www.wohrle.be

Junger GmbH
Gütersloh
www.junger-gmbh.de
Novelty:
Variant with integrated access-protection LAN <=> bus-side as well as output of diagnostic-buffer in web-site

Networking of SIMATIC S7-PLCs (S7-200/300/400) without Ethernet-CP/CP-communicationprocessor standard-TCP/IP without changes to the hardware-configuration or PLC-program.
Compact and robust Ethernet-converter (MPI / PROFIBUS / PPI - Ethernet).
Similar to "IBH Link S7++" (IBH-Link-S7-PP, 20266), "NETLink PRO Compact", "ACCON-NetLink-PRO compact" or "NL 50-MPI".
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET function.
By plugging the module onto the PPI, MPI or Profibus, this connection becomes an Ethernet port for the Industrial IoT with significant cost savings.
Thanks to the integrated multiplexer, this connection becomes a port for all supported protocols. Simultaneous and parallel communications such as WinCC, PUT/GET from S7 PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step7, TIA Portal or PG2000.

Advantages:
  • Simple and fast networking
  • Multiplexer for all protocols
  • Integration as S7 controller with CP 343-1
  • Access to S7 data via S7-TCP/IP with PUT/GET
  • Module search without "annoying" network-card-selection
  • Free virtual-com-port for non-Step7-applications
  • Qualified support
  • Comprehensive documentation
  • No SimaticNet required for operation/configuration
  • STEP7 64-bit support
  • Integration into the TIA-Portal
  • Supports DHCP

Connectivity:
  • S7-LAN module directly connected to the PC/device with a patch cable
  • S7-LAN module directly connected to the PC/device with a crosslink cable
  • S7-LAN connected to the PC/device via a switch or hub

Features:
  • every SIMATIC-S7 (S7-200/300/400) into Network
  • SIMATIC S7-protocols (S7Comm and ISO-on-TCP (RFC 1006))
  • Ethernet-RJ45 socket with 10/100 MBit/s with autonegotiation
  • Commissioning is very simple: plug it into the PPI, MPI-bus or PROFIBUS of the SIMATIC S7 controller and start working
  • Integrated multiplexer (visualization, programming, remote maintenance and simultaneous use of all protocols without special configuration), also via standard router
  • Parallel use of the channels (simultaneously 8 x channels for programming, visualization and remote maintenance can be used directly/routed)
  • Supported controllers (S7-200, S7-300, S7-400, FM modules, Sinamix, Sinumerik, MicroMaster and other drives/converters (such as SEW-EURODRIVE converters)
  • Supported data areas (inputs, outputs, markers, data blocks, timers and counters)
  • Supported scenarios (programming adapter for S7 programming packages, access to the S7 data via S7-TCP/IP with PUT/GET and routing of SIMATIC S7 controllers as well as time server for time and also bus diagnostics)
  • Supported platforms (S7-TCPIP RFC1006 communication platform-independent, communication driver/configuration tool TIC for Windows XP, Win7/8/10/11)
  • Replacement for CP343-1/443-1 or IE/PB-Link, connected directly to MPI or Profibus (inexpensive)
  • with Profibus for S7-300 faster than CP343-1
  • PG/PC-adapter for Simatic-Manager Step7 and TIA-portal
  • fastest installation into Network (less than 3 minutes)
  • automatic detection of baudrate
  • automatic usement of cyclic bus-parameter-protocols
  • no bus-knowledge required / automatic-protocol and baud-rate detection
  • download TIC-driver for STEP-7/TIA-Portal
  • Programming and visualization at the same time (8 S7-connections (direct / routed) at the same time)
  • compatible to S7-TCP/IP RFC1006, WinCC (flex), OPC UA with Universal communication Industry 4.0, the IP-S7LINK SDK as well as all common OPC-servers
  • no HW-Config change necessary
  • no change of PLC-software necessary
  • including Classic OPC-DA-Server-lite (max. 100 variables)
  • with PG-diagnostic-port (occupied slot with 9pin PG-port free again)
  • DPV1-master of class 2 and supports all functions that a PG supports:
    • Diagnosis, configuration and programming of controllers (via software such as Simatic-Manager, TIA-Portal)
    • Diagnosis and configuration of DP-slaves (via software such as Starter)
  • active module, no influencing other bus users in the system
  • active PUT/GET (in module integrated) replaces expensive CP´s for PLC-couplings
  • Supply from S7-PLC or 24V DC external
  • CE/EMC compliant design
  • Scope of delivery (TIC driver, module itself and quick start guide)
  • Search for modules across all Network-cards (no Network-card-selection as with other providers)
  • Variable status in web interface
  • RFC1006 connection status
  • PLC-time via PG-protocol
  • TCPIP-device writes/reads DB in S7-PLC
  • Bus-diagnostics (output of error-counters, spikes)
  • RFC1006 for S7-200 (1. Generation)
  • virtual COM-port-driver for other serial S7-applications
  • Standard HMI-applications can read/write data via RFC1006 and the module


Applications:

  • Operational data collection, SCADA of non-networkable controllers
  • KTP-panel to S7-PLC with MPI-/Profibus-interface
  • PUT/GET from S7-1500/1200/300/400 (PN-CPU or with ethernet-CP) with specified and unspecified connection
  • VPN(Virtual Private Network)-remote-maintenance, maintenance of the PLC via the Internet
  • cyclic time reading from NTP-server and setting in the connected PLC
  • coupling with DB-transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or also S5-Gateway
  • any TCP-device writes/reads DBs in the S7-300/400 controller
  • monitor variables in the WebServer without a Step7 programming-package
  • analysis option of the connected bus-system with spikes- and errors-counter
  • Parameterization of field devices and drives (DPV1)
  • With IP-S7-Link-DLL high-level languages-access
  • PLC-PLC-communication (regardless of subnet boundaries, prolongation MPI/DP-bus over network)

TIC-(Totally Integrated Communication)-driver for Step7/TIA-Portal for Win XP/VISTA/7/8/10/11 32/64 Bit:
TIC firmware / configuration-tool / Step7-/TIA-driver

Product overview:

S7-LAN is a reliable and handy S7-network-adapter for PPI-,MPI- and PROFIBUS. Designed for 24/7-operation. The compact design in the PROFIBUS-connector-case and the power supply directly from the MPI/DP-port of the CPU allow to be connected a PLC to the network in less than 3 minutes.
bus protocols/bus profile, incl. baudrate and HSA are recognized independently and automatically and configured.
HMI-devices, for e.g. actual panel-series, as well as any other S7-Ethernet device, direct connect per S7-TCP-IP.
With TIC-driver (configurations-tool and driver) from download-area without changes on the project of Siemens TIA, Simatic Step7 Manager and WinCC-projects communication.
Another advantage is the easy handling of the S7-LAN. The convenient configuration is carried out directly in STEP7 or the PG/PC-interface-dialog. The detection of whether the S7-LAN is connected to a 10 MBit or 100 MBit network takes place automatically. Power is supplied directly from the MPI / DP interface. The connection to passive participants or VIPA-PLC is possible via the integrated 24V-plug.
The S7-LAN is connected to the bus-socket of the PLC and via the hub or directly to the PC. Then install the TIC-driver on the PC. Assign the IP-address with the TIC-configuration-program and go ONLINE. The installation process is completed so quickly.

Configuration:

S7-LAN is designed for quick commissioning. After the module has been plugged into the bus or externally supplied with 24V DC, only an IP address is assigned via the TIC-driver or directly via the Web-interface . The controllers can then be accessed from the network.
With the TIC-driver, there is no need for any additional installation outside of the Siemens world. The configuration takes place directly in the PG-PC interface settings and is therefore optimally integrated. Any network device that speaks S7-TCP/IP RFC1006, such as HMI-devices or PGs, can access the module directly.
In the S7-project itself, the adapter can be integrated using a placeholder entry. This is not a must, operation without project change is possible immediately. The S7-communication runs directly via S7-TCP/IP and expands each MPI-/PROFIBUS with a network gateway. It doesn't matter which control types (S7-200 / S7-300 / S7-400) are connected to the fieldbus of the PLC network.
Remote maintenance / telecontrol of PLC
Produkbild
Access to the connected PLC takes place by coupling via Analogue-, ISDN-, mixed Analogue-ISDN-, GSM-, UMTS-line and also via Internet with and without VPN-security.
Analogue and ISDN - how do they come together?
Produkbild

You have on the plant side only ISDN for telephone, but in your office there is only an analogue system? No problem, you have to install on the clients side the TP-II and activate there the analogue-emulation in the device. No, the modem signals will be send digitalized over ISDN and you can connect to it. So, you will be able to communicate though the telephone systems are different and your client isn´t forced to install an analogue connection.

Router - Mode (access to the network without router)
Produkbild
The Tele-Prof-II can also be used as a router for access from a PC via dial-up connection, so that a communication with the behind covered network results. Furthermore a network connection can be made with the TP-II <=> TP-II-line, but in doing so the IP-address-root must differ.
User dependant network access
Produkbild
You have PLC/LAN-participants different supplier in your network and everybody should have access to this network? No problem, you give every supplier a VPN-username and passwort, define in the destination device a user-dependent network-access and after positiv login he only can communicate to the released ip-addresses.
Separate your machine-net from the office-net
Produkbild
You need a separation between the machine-net and the office-net? No problem, plug a PCMCIA-LAN-card in your Tele-Prof-II-device (only for version -H) and the separation is OK. You have access to both nets via remote maintenance.
S7-CP-alternate (without LAN-CP to the PLC)
Produkbild
Do you have a PLC without CP343-1 or CP443-1 and a TP-II as remote maintenance device? Then activate the CP-mode of the TP-II and your visualisation goes directly ONLINE via the LAN of the TP-II.
PLC coupling (data exchange between PLCs)
Produkbild
Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Thereto no dedicated line is required, a “normal” telephone connection is sufficient because the devices cut the line after occured message.
Failure report transmission without any change in the PLC programm
Produkbild
Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, as SMS to your mobile phone, to your pager or also via e-mail. And this without an intervention of the PLC-program. Here the variables and actions are stored and processed in the TP-II.
Failure report transmission released by the PLC
Produkbild
Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, as SMS to your mobile phone, to your pager or also via e-mail.
Remote maintenance of centralized PLC-devices
Produkbild
You have many PLC and you want to programm them central on one place? No problem, you have to connect them all to the KOR/MUX-Tele-Switch, connect it with the TP-II and after telephone connect you will be able with the PD-bus-selection of your Step5-software to go ONLINE. Of course the MOR/MUX-Tele-Switch is cascadable, so you can connect up to 30 PLCs to the devices.
Sending ASCII-data to a PC
Produkbild
Your car park or control sends the configuration / capacity utilisation to a PC with a modem, so that the data can be used for further processing.
Direct-mode "extended serial interface"
Produkbild
There is an unsupported control or data logger or converter integrated in your installation which protocol is not supported? No problem, the signs that the PC in the office sends will be transferred via telephone line by the Direct-mode, and on-site reproduced by the TP-II. The way back is identical. So in that case there’s also a communication to the electronic devices available.
Data logger with FTP-interface
Produkbild
You need a data logger which tape-records the specified data of the PLC and you can collect the data via FTP on demand. No problem, TP-II with the option Datalogger is the solution for you.
Supply voltage: 24V DC +/- 20%
Power consumption: 15 watt
Display: expressive LCD display
5 status LEDs
Handling/Configuration: integrated keypad
WEB-Browser
Interfaces:
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
TTY/20mA current loop (AG-TELE aktiv, PLC passiv)
RS232: 9,6 KBd - 115,2 KBd / fully assigned
to the PD/PC:
10/100BaseTX RJ45-ethernet jack
TTY/20mA current loop (100 % mechanically and electr. compatible)
RS232: 9,6 KBd - 115,2 KBd / with a 1on1-cable to the PC
others:
2xUSB, 2xPCMCIA (only for version -H)
Integrated modem: 33K6 HIGH-SPEED, V.42/BIS MNP5 analogue modem
ISDN (Euro ISDN + 1TR6)
Operating temperature: 0 - 55°C
Case: powder coated metal case with mounting flange and DIN-rail mounting
Dimensions: Flat 300 x 175 x 70 mm
Hoch 67 x 280 x 170 mm
 
Scope of delivery: Tele-Prof-II
Power connector 3pins big
All prices plus costs of delivery, shipping insurance and VAT.

accessories:

9352.1
USB-cable plug/plug type A-A 3m

USB 1.1 / 2.0 up to 480 MBit
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


9359.1:1
1:1 cable 9pins D-SUB

D-SUB 9pins (male) <=> D-Sub 9pins (female), 1to1-assignment
Quickbestellung INFOMAIL
by e-mail
28,00 €
plus VAT. and shipping


9361-3
S5-connecting cable 3m

forTELE-PROF, MINI-/PG-MUX-II
9361-3.05M
S5-connecting cable 5m

for TELE-PROF, MINI-/PG-MUX-II
9361-3.06M
S5-connecting cable 6m

for TELE-PROF, MINI-/PG-MUX-II
9361-3.10M
S5-connecting cable 10m

for TELE-PROF, MINI-/PG-MUX-II
9370-8-AT
Special phone-cable for Austria Obsolete

RJ12 plug <=> telephone plug of Austria
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-BE
Special phone-cable for Belgium

RJ12 plug <=> telephone plug of Belgium
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-CH
Special phone-cable for Switzerland Obsolete

RJ12 plug <=> telephone plug of Switzerland
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-D/USA
Phone-cable analogue Germany+USA

RJ12 plug <=> RJ12 plug with TAE-adapter for Germany
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


9370-8-DK
Special phone-cable for Denmark

RJ12 plug <=> telephone plug of Denmark
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-FR
Special phone-cable for France

RJ12 plug <=> telephone plug of France
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-GB
Special phone-cable for Great Britain

RJ12 plug <=> telephone plug of Great Britain
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-ISDN
Phone-cable ISDN

RJ45 plug <=> RJ45 plug, assigned 1to1
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


9370-8-IT
Special phone-cable for Italy

Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-NL
Special phone-cable for Netherlands

RJ12 plug <=> telephone plug of the Netherlands
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


244,00 €
plus VAT. and shipping


9370-TAE
TAE junction box

analogue telephone box (NFN) for on-wall mounting
Quickbestellung INFOMAIL
by e-mail
22,00 €
plus VAT. and shipping


9371-6
Servicebag

for TP, TB + TP-II-FLAT
Quickbestellung INFOMAIL
by e-mail
63,00 €
plus VAT. and shipping


172,00 €
plus VAT. and shipping


9372-24
Power connector 3pins big

connector plug lockable by jack with screws
Quickbestellung INFOMAIL
by e-mail
4,00 €
plus VAT. and shipping


9372-LANCARD
Network-card for TP-II Obsolete

Ethernet networkcard Cardbus PCMCIA 10/100
Quickbestellung INFOMAIL
by e-mail
105,00 €
plus VAT. and shipping


9372-UMTS-Ant
UMTS directional antenna
external antenna for the UMTS-card
Quickbestellung INFOMAIL
by e-mail
199,00 €
plus VAT. and shipping


9379.1
MPI-/Profibus connecting cable 1m

connects MPI-modem/TP-II with the S7-PLC
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


9391-MT
Mounting set

for DIN-rail-holder, self mounting
Quickbestellung INFOMAIL
by e-mail
27,00 €
plus VAT. and shipping


9391.1
24V DC power-supply unit 625mA

Primary 110V - 240 VAC Euro+USA-plug
Quickbestellung INFOMAIL
by e-mail
59,00 €
plus VAT. and shipping


9636-CROSS
Cross-cable 3m Cat5+, shielded

RJ45 plug <=> RJ45 plug, twisted pinning
9636-TCPIP
Patch-cable 3m, Cat5+, shielded

RJ45 plug <=> RJ45 plug, 1:1
All prices plus costs of delivery, shipping insurance and VAT.

9372-OEM
TELE-PROFessional II worldwide use

OEM - Version (all accessories optional) without PCMCIA-Slot for UMTS-/LAN-card
Quickbestellung INFOMAIL
by e-mail
1260,00 €
plus VAT. and shipping




maximum 3 articles
9372-FLAT
TELE-PROFessional II worldwide use

flat version / OEM - Version (all accessories optional) without PCMCIA-slot for UMTS-/LAN-card
Quickbestellung INFOMAIL
by e-mail
1260,00 €
plus VAT. and shipping




maximum 3 articles
9372-FLAT-H
TELE-PROFessional II worldwide use
flat version / OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
Quickbestellung INFOMAIL
by e-mail
1313,00 €
plus VAT. and shipping


9372-OEM-H
TELE-PROFessional II worldwide use
OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
Quickbestellung INFOMAIL
by e-mail
1313,00 €
plus VAT. and shipping


All prices plus costs of delivery, shipping insurance and VAT.

9370-8-D/USA
Phone-cable analogue Germany+USA

RJ12 plug <=> RJ12 plug with TAE-adapter for Germany
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


9352-LANCON
S7-LAN connector for Siemens S7 PLC controller

Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
Quickbestellung INFOMAIL
by e-mail
423,00 €
plus VAT. and shipping


9359-LAN
S5-LAN++

Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
Quickbestellung INFOMAIL
by e-mail
452,00 €
plus VAT. and shipping


9379.1
MPI-/Profibus connecting cable 1m

connects MPI-modem/TP-II with the S7-PLC
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


9359-1.05M
PG-USB-cable 5m for Siemens S5 Controller

for PLC's + LED + metal case
Quickbestellung INFOMAIL
by e-mail
174,00 €
plus VAT. and shipping


9359-1
PG-USB-cable 3m for Siemens S5 Controller

for PLC's + LED + metal case
Quickbestellung INFOMAIL
by e-mail
145,00 €
plus VAT. and shipping


Automatic-mode

Other downloads