S7-LAN connector for Siemens S7 PLC controller - Process Informatik Entwicklungsgesellschaft mbH

S7-LAN connector for Siemens S7 PLC controller Download


Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1

singlelicense
windows (any) (from .Net 3.5)

Novelty:
Variant with integrated access-protection LAN <=> bus-side as well as output of diagnostic-buffer in web-site

Networking of SIMATIC S7-PLCs (S7-200/300/400) without Ethernet-CP/CP-communicationprocessor standard-TCP/IP without changes to the hardware-configuration or PLC-program.
Compact and robust Ethernet-converter (MPI / PROFIBUS / PPI - Ethernet).
Similar to "IBH Link S7++" (IBH-Link-S7-PP, 20266), "NETLink PRO Compact", "ACCON-NetLink-PRO compact" or "NL 50-MPI".
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET function.
By plugging the module onto the PPI, MPI or Profibus, this connection becomes an Ethernet port for the Industrial IoT with significant cost savings.
Thanks to the integrated multiplexer, this connection becomes a port for all supported protocols. Simultaneous and parallel communications such as WinCC, PUT/GET from S7 PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step7, TIA Portal or PG2000.

Advantages:

more...
variants:

Price on request plus VAT. and shipping

ARTNR: 9771-S7L
PLC-data logging/triggering TCP/IP S7 - Standard
EAN number: 4260363245814
HS-code: 85234990


Novelty:
Variant with integrated access-protection LAN <=> bus-side as well as output of diagnostic-buffer in web-site

Networking of SIMATIC S7-PLCs (S7-200/300/400) without Ethernet-CP/CP-communicationprocessor standard-TCP/IP without changes to the hardware-configuration or PLC-program.
Compact and robust Ethernet-converter (MPI / PROFIBUS / PPI - Ethernet).
Similar to "IBH Link S7++" (IBH-Link-S7-PP, 20266), "NETLink PRO Compact", "ACCON-NetLink-PRO compact" or "NL 50-MPI".
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET function.
By plugging the module onto the PPI, MPI or Profibus, this connection becomes an Ethernet port for the Industrial IoT with significant cost savings.
Thanks to the integrated multiplexer, this connection becomes a port for all supported protocols. Simultaneous and parallel communications such as WinCC, PUT/GET from S7 PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step7, TIA Portal or PG2000.

Advantages:
  • Simple and fast networking
  • Multiplexer for all protocols
  • Integration as S7 controller with CP 343-1
  • Access to S7 data via S7-TCP/IP with PUT/GET
  • Module search without "annoying" network-card-selection
  • Free virtual-com-port for non-Step7-applications
  • Qualified support
  • Comprehensive documentation
  • No SimaticNet required for operation/configuration
  • STEP7 64-bit support
  • Integration into the TIA-Portal
  • Supports DHCP

Connectivity:
  • S7-LAN module directly connected to the PC/device with a patch cable
  • S7-LAN module directly connected to the PC/device with a crosslink cable
  • S7-LAN connected to the PC/device via a switch or hub

Features:
  • every SIMATIC-S7 (S7-200/300/400) into Network
  • SIMATIC S7-protocols (S7Comm and ISO-on-TCP (RFC 1006))
  • Ethernet-RJ45 socket with 10/100 MBit/s with autonegotiation
  • Commissioning is very simple: plug it into the PPI, MPI-bus or PROFIBUS of the SIMATIC S7 controller and start working
  • Integrated multiplexer (visualization, programming, remote maintenance and simultaneous use of all protocols without special configuration), also via standard router
  • Parallel use of the channels (simultaneously 8 x channels for programming, visualization and remote maintenance can be used directly/routed)
  • Supported controllers (S7-200, S7-300, S7-400, FM modules, Sinamix, Sinumerik, MicroMaster and other drives/converters (such as SEW-EURODRIVE converters)
  • Supported data areas (inputs, outputs, markers, data blocks, timers and counters)
  • Supported scenarios (programming adapter for S7 programming packages, access to the S7 data via S7-TCP/IP with PUT/GET and routing of SIMATIC S7 controllers as well as time server for time and also bus diagnostics)
  • Supported platforms (S7-TCPIP RFC1006 communication platform-independent, communication driver/configuration tool TIC for Windows XP, Win7/8/10/11)
  • Replacement for CP343-1/443-1 or IE/PB-Link, connected directly to MPI or Profibus (inexpensive)
  • with Profibus for S7-300 faster than CP343-1
  • PG/PC-adapter for Simatic-Manager Step7 and TIA-portal
  • fastest installation into Network (less than 3 minutes)
  • automatic detection of baudrate
  • automatic usement of cyclic bus-parameter-protocols
  • no bus-knowledge required / automatic-protocol and baud-rate detection
  • download TIC-driver for STEP-7/TIA-Portal
  • Programming and visualization at the same time (8 S7-connections (direct / routed) at the same time)
  • compatible to S7-TCP/IP RFC1006, WinCC (flex), OPC UA with Universal communication Industry 4.0, the IP-S7LINK SDK as well as all common OPC-servers
  • no HW-Config change necessary
  • no change of PLC-software necessary
  • including Classic OPC-DA-Server-lite (max. 100 variables)
  • with PG-diagnostic-port (occupied slot with 9pin PG-port free again)
  • DPV1-master of class 2 and supports all functions that a PG supports:
    • Diagnosis, configuration and programming of controllers (via software such as Simatic-Manager, TIA-Portal)
    • Diagnosis and configuration of DP-slaves (via software such as Starter)
  • active module, no influencing other bus users in the system
  • active PUT/GET (in module integrated) replaces expensive CP´s for PLC-couplings
  • Supply from S7-PLC or 24V DC external
  • CE/EMC compliant design
  • Scope of delivery (TIC driver, module itself and quick start guide)
  • Search for modules across all Network-cards (no Network-card-selection as with other providers)
  • Variable status in web interface
  • RFC1006 connection status
  • PLC-time via PG-protocol
  • TCPIP-device writes/reads DB in S7-PLC
  • Bus-diagnostics (output of error-counters, spikes)
  • RFC1006 for S7-200 (1. Generation)
  • virtual COM-port-driver for other serial S7-applications
  • Standard HMI-applications can read/write data via RFC1006 and the module


Applications:

  • Operational data collection, SCADA of non-networkable controllers
  • KTP-panel to S7-PLC with MPI-/Profibus-interface
  • PUT/GET from S7-1500/1200/300/400 (PN-CPU or with ethernet-CP) with specified and unspecified connection
  • VPN(Virtual Private Network)-remote-maintenance, maintenance of the PLC via the Internet
  • cyclic time reading from NTP-server and setting in the connected PLC
  • coupling with DB-transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or also S5-Gateway
  • any TCP-device writes/reads DBs in the S7-300/400 controller
  • monitor variables in the WebServer without a Step7 programming-package
  • analysis option of the connected bus-system with spikes- and errors-counter
  • Parameterization of field devices and drives (DPV1)
  • With IP-S7-Link-DLL high-level languages-access
  • PLC-PLC-communication (regardless of subnet boundaries, prolongation MPI/DP-bus over network)

TIC-(Totally Integrated Communication)-driver for Step7/TIA-Portal for Win XP/VISTA/7/8/10/11 32/64 Bit:
TIC firmware / configuration-tool / Step7-/TIA-driver

Product overview:

S7-LAN is a reliable and handy S7-network-adapter for PPI-,MPI- and PROFIBUS. Designed for 24/7-operation. The compact design in the PROFIBUS-connector-case and the power supply directly from the MPI/DP-port of the CPU allow to be connected a PLC to the network in less than 3 minutes.
bus protocols/bus profile, incl. baudrate and HSA are recognized independently and automatically and configured.
HMI-devices, for e.g. actual panel-series, as well as any other S7-Ethernet device, direct connect per S7-TCP-IP.
With TIC-driver (configurations-tool and driver) from download-area without changes on the project of Siemens TIA, Simatic Step7 Manager and WinCC-projects communication.
Another advantage is the easy handling of the S7-LAN. The convenient configuration is carried out directly in STEP7 or the PG/PC-interface-dialog. The detection of whether the S7-LAN is connected to a 10 MBit or 100 MBit network takes place automatically. Power is supplied directly from the MPI / DP interface. The connection to passive participants or VIPA-PLC is possible via the integrated 24V-plug.
The S7-LAN is connected to the bus-socket of the PLC and via the hub or directly to the PC. Then install the TIC-driver on the PC. Assign the IP-address with the TIC-configuration-program and go ONLINE. The installation process is completed so quickly.

Configuration:

S7-LAN is designed for quick commissioning. After the module has been plugged into the bus or externally supplied with 24V DC, only an IP address is assigned via the TIC-driver or directly via the Web-interface . The controllers can then be accessed from the network.
With the TIC-driver, there is no need for any additional installation outside of the Siemens world. The configuration takes place directly in the PG-PC interface settings and is therefore optimally integrated. Any network device that speaks S7-TCP/IP RFC1006, such as HMI-devices or PGs, can access the module directly.
In the S7-project itself, the adapter can be integrated using a placeholder entry. This is not a must, operation without project change is possible immediately. The S7-communication runs directly via S7-TCP/IP and expands each MPI-/PROFIBUS with a network gateway. It doesn't matter which control types (S7-200 / S7-300 / S7-400) are connected to the fieldbus of the PLC network.
Licensing process:
Free download of the complete range of functions
for 14 days:
/9352-LANCON_s7-lan.html/9771-S7L_sps-daten-loggentriggern.html/

Licensing under "License"
(mouse click on the key symbol)
Your machine-code for this PC with order by email
to verkauf@process-informatik.de
You will receive a license code to enter under
"License", so that the program is licensed on your
PC.
With a USB-dongle, there is no machine-code, the
USB-dongle contains the license, comes via UPS.
PLC-data in Excel-readable file
Produkbild

Save your PLC content, production-data in a file on your PC. This file, a CSV- or XML-file (depending on the license), can then be used e.g. further processed with Excel.
A file that includes all configured variables in an infinitely-long list with a suitable time-stamp, either controlled by the PC or via a PLC-trigger (depending on the license). No matter which Siemens-control, as soon as a network-connection is available, nothing stands in the way of recording.
With S7-LAN for PPI, MPI or Profibus or S5-LAN++ for S5-controllers, PLCs without a network-connection can also be addressed and recorded. And depending on the license are several parallel connections possible.

All prices plus costs of delivery, shipping insurance and VAT.

support-service:

SUP-9771-S7L
Software Update & Support service

Automatical Upgrade for innovations incl. technical support for 12 months for a single-license standard Requirements: single-license PLC-data logging/triggering- standard-version not older than 9 months or together with PLC-data logging/triggering.
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

SUP-9771-S7L-E-DO
Software Update & Support service dongle-version

Automatical Upgrade for innovations incl. technical support for 12 months for a single-license expert Requirements: single-license PLC-data logging/triggering- expert-version not older than 9 months or together with PLC-data logging/triggering with dongle-license
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

SUP-9771-S7L-DO
Software Update & Support service dongle-version

Automatical Upgrade for innovations incl. technical support for 12 months for a single-license standard Requirements: single-license PLC-data logging/triggering- standard-version not older than 9 months or together with PLC-data logging/triggering with dongle-license
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

SUP-9771-S7L-E-3
Software Update & Support service

Automatical Upgrade for innovations incl. technical support for 12 months for a Site / Branch / Standort License expert Requirements: Site / Branch / Standort License PLC-data logging/triggering-expert-version not older than 9 months or together with PLC-data logging/triggering.
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

SUP-9771-S7L-E-2
Software Update & Support service

Automatical Upgrade for innovations incl. technical support for 12 months for a subsequent-license expert Requirements: subsequent-license PLC-data logging/triggering- expert-version not older than 9 months or together with PLC-data logging/triggering.
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

SUP-9771-S7L-E
Software Update & Support service

Automatical Upgrade for innovations incl. technical support for 12 months for a single-license expert Requirements: single-license PLC-data logging/triggering- expert-version not older than 9 months or together with PLC-data logging/triggering.
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

SUP-9771-S7L-A-3
Software Update & Support service

Automatical Upgrade for innovations incl. technical support for 12 months for a Site / Branch / Standort License advanced Requirements: Site / Branch / Standort License PLC-data logging/triggering-advanced-version not older than 9 months or together with PLC-data logging/triggering.
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

SUP-9771-S7L-A-2
Software Update & Support service

Automatical Upgrade for innovations incl. technical support for 12 months for a subsequent-license advanced Requirements: subsequent-license PLC-data logging/triggering- advanced-version not older than 9 months or together with PLC-data logging/triggering.
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

SUP-9771-S7L-A
Software Update & Support service

Automatical Upgrade for innovations incl. technical support for 12 months for a single-license advanced Requirements: single-license PLC-data logging/triggering- advanced-version not older than 9 months or together with PLC-data logging/triggering.
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

SUP-9771-S7L-3
Software Update & Support service

Automatical Upgrade for innovations incl. technical support for 12 months for a Site / Branch / Standort License Standard Requirements: Site / Branch / Standort License PLC-data logging/triggering-standard-version not older than 9 months or together with PLC-data logging/triggering.
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

SUP-9771-S7L-2
Software Update & Support service

Automatical Upgrade for innovations incl. technical support for 12 months for a subsequent-license standard Requirements: subsequent-license PLC-data logging/triggering- standard-version not older than 9 months or together with PLC-data logging/triggering.
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

SUP-9771-S7L-A-DO
Software Update & Support service dongle-version

Automatical Upgrade for innovations incl. technical support for 12 months for a single-license advanced Requirements: single-license PLC-data logging/triggering- advanced-version not older than 9 months or together with PLC-data logging/triggering with Dongle-license
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

accessories:

9771-DO
PLC-data logging/triggering license-dongle AddOn

USB-dongle with license-key instead of software-key windows (any) from Win7
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

All prices plus costs of delivery, shipping insurance and VAT.

Einzel-Lizenz

9771-S7L
PLC-data logging/triggering TCP/IP S7 - Standard

singlelicense windows (any) (from .Net 3.5)
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

9771-S7L-A
PLC-data logging/triggering TCP/IP S7 - Advanced

Singlelicense windows (any) (from .Net 3.5)
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

9771-S7L-E
PLC-data logging/triggering TCP/IP S7 - Expert

singlelicense windows (any) (from .Net 3.5)
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

Folge-Lizenz

9771-S7L-2
PLC-data logging/triggering TCP/IP S7 - Standard

subsequentlicense windows (any) (from .Net 3.5)
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

9771-S7L-A-2
PLC-data logging/triggering TCP/IP S7 - Advanced

subsequentlicense windows (any) (from .Net 3.5)
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

9771-S7L-E-2
PLC-data logging/triggering TCP/IP S7 - Expert

subsequentlicense windows (any) (from .Net 3.5)
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

Standort-Lizenz

9771-S7L-3
PLC-data logging/triggering TCP/IP S7 - Standard

Site / Branch / Standort License windows (any) (from .Net 3.5)
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

9771-S7L-A-3
PLC-data logging/triggering TCP/IP S7 - Advanced

Site / Branch / Standort License windows (any) (from .Net 3.5)
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

9771-S7L-E-3
PLC-data logging/triggering TCP/IP S7 - Expert

Site / Branch / Standort License windows (any) (from .Net 3.5)
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

All prices plus costs of delivery, shipping insurance and VAT.

SUP-9771-S7L
Software Update & Support service

Automatical Upgrade for innovations incl. technical support for 12 months for a single-license standard Requirements: single-license PLC-data logging/triggering- standard-version not older than 9 months or together with PLC-data logging/triggering.
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

9771-DO
PLC-data logging/triggering license-dongle AddOn

USB-dongle with license-key instead of software-key windows (any) from Win7
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

9352-LANCON
S7-LAN connector for Siemens S7 PLC controller

Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
Quickbestellung INFOMAIL
by e-mail
423,00 €
plus VAT. and shipping


9773-DO
PLC-data in Excel license-dongle AddOn

USB-dongle with license-key instead of software-key windows (any) from Win7
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

9771-S7L-A
PLC-data logging/triggering TCP/IP S7 - Advanced

Singlelicense windows (any) (from .Net 3.5)
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

SUP-9771-S7L-A
Software Update & Support service

Automatical Upgrade for innovations incl. technical support for 12 months for a single-license advanced Requirements: single-license PLC-data logging/triggering- advanced-version not older than 9 months or together with PLC-data logging/triggering.
INFOMAIL
by e-mail
price on request
plus VAT. and shipping

Automatic-mode