MPI-LAN












S7-Interface cable for PPI, MPI, Profibus, HMI <=> LAN applications
- Supplied driver TIC (Total Integrated Communication) (runs under Win XP, VISTA, Win7/8/8.1, Win10) allows communication and configuration of the interface product
- Function with TIA-Portal and Simatic-Manager, also with WinCC and Comfort Panel
- Automatic protocol- and baud rate detection (depends on the used product from 9K6 to 12M)
- Connects only to the bus when it is requested by PG
- Firmwareupdate via internet for free
- PPI - adapter for S7 - 200
- MPI/Profibus - adapter for S7 - 300 + 400
- CE/EMC compliant construction
- All intelligent MPI-interface-products including a free OPC-server license "OPC-Manager lite" [limited to 100 items]
more...
399,- €
plus VAT. and shipping
plus VAT. and shipping
ARTNR: 9352-LAN
MPI-LAN-cable 3m
Obsolete
EAN number: | 4260363240949 |
HS-code: | 85444290 |
Weight: | 0.3 kg |
S7
PPI-Bus | |||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||
19.2 KBit/s |
x
|
x
|
|||||
38.4 KBit/s |
x
|
x
|
|||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||
USB | |||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||
LAN | |||||||
10/100BaseTx |
x(7)
|
x
|
x
|
||||
WIFI | |||||||
2.4 GHz |
x
|
||||||
TeleService operation | |||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||
baud rates at TS-operation directly at the PC | |||||||
9.6 KBit/s |
x
|
x
|
|||||
19.2 KBit/s |
x
|
x
|
|||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||
baud rates at TS-operation directly with a modem | |||||||
9.6 KBit/s |
x
|
x
|
|||||
19.2 KBit/s |
x
|
x
|
|||||
38.4 KBit/s |
x
|
x
|
|||||
57.6 KBit/s |
x
|
x
|
|||||
115.2 KBit/s |
x
|
x
|
|||||
HMI | |||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||
PLCVCOM |
1
|
1
|
8
|
1
|
8
|
8
|
|
RFC1006 |
x
|
x
|
x
|
||||
AG connections (maximum) | |||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||
webserver for configuration |
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
||||
galvanic separation | |||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
mounting | |||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||
upgrading with | |||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||
supports | |||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
- Supplied driver TIC (Total Integrated Communication) (runs under Win XP, VISTA, Win7/8/8.1, Win10) allows communication and configuration of the interface product
- Function with TIA-Portal and Simatic-Manager, also with WinCC and Comfort Panel
- Automatic protocol- and baud rate detection (depends on the used product from 9K6 to 12M)
- Connects only to the bus when it is requested by PG
- Firmwareupdate via internet for free
- PPI - adapter for S7 - 200
- MPI/Profibus - adapter for S7 - 300 + 400
- CE/EMC compliant construction
- All intelligent MPI-interface-products including a free OPC-server license "OPC-Manager lite" [limited to 100 items]
- All products, including the examples and demo-version of communication driver as download on the product-site
- Master-class 2 for acyclic services (DPV1)
- PUT/GET from S7-1500/1200/300/400(PN or with ethernet-cp) with spezific and unspezific connection possible
- Cyclic read of time from NTP server and set in the connected PLC
- Coupling with DB-transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5 Gateway
- Any TCP-device writes/reads DBs in the S7-300/400-PLC
- Monitor/control variables in the Web-server without Step7-programming-package
- Analysis-option of the connected bus for spikes and error-counter
- Power supply from the S7-PLC or external
- Network configuration free adjustable
- VPN remote maintenance possible / for the maintenance of the PLC via Internet
- Integrated display for output of diagnostic informations
- Double-sided connected cable
- Short plug to PLC
- Provides the coupling with Android operating-system [for example S7Droid]
Programming of S7-PLCs via LAN

You would like to respond to your S7-PLC-device via LAN but not integrate an Ethernet-CP? No problem, plug the S7-LAN or also the MPI-LAN-cable on the MPI/PPI/Profibus-interface and access via LAN.
Watching of S7-PLC-devices via LAN without Ethernet-CP

Your panel only has a LAN-socket as PLC-interface? No problem, connect this socket with the S7-LAN or the MPI-LAN-cable and plug it directly on the PPI/MPI/Profibus of the PLC. Then access to the
variables and data of the PLC is already available.
S7-CP-replacement (without LAN-CP to the PLC-device)

Do you have a S7-PLC-device without CP243-1, CP343-1 or CP443-1 and would like to connect via LAN? Then plug the S7-LAN on the PLC-device and your access via RFC1006 is ready for use.
Remote maintenance / telecontrol of PLC-devices via LAN / internet

You have access to a on-site network and your PLC-device has no LAN-connection? No problem, plug the S7-LAN on the PLC-device and you will have immediate access to the PLC from afar.
Without LAN-cable round of the PLC

Your’re right in the middle of your production line and and should move around the machine and simultaneously observe / manage. No problem, you parameterize the S7-WLAN-Bridge, connect to the MPI-LAN and connect to an access-point or with the ad-hoc-network of your laptop and are ONLINE on the PLC.
Transformation of Rack/Slot in TSAP to MPI-address

Your panel or visualisationsystem addresses the used PLC with Rack/Slot in TSAP? No problem, activate this mode in the MPI-LAN-cable and you will get actual data from the PLC.
PLC-coupling (data exchange between PLC-devices)

Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Thereto no
dedicated line is required, it’s sufficient when the stations connect via network (DSL-router).
Actual time for the PLC?

You need in your PLC a actual time? No problem, with the NTP-function the MPI-LAN-cable get from a NTP-(Time-)Server the actual time and transfers it direct into the configured PLC or for
processing in a DB.
Variable-chart without Step7-programming package

You would like to give your customer the opportunity to read current numbers of the manufacturing Online, without installing a visualisation or even the STEP7-package? Then a S7-LAN with the option
„Status Variable“ is needed, and your customer can take a look at these password protected data on a site of the integrated webserver.
Malfunctions on the Bus although everything is (apparently) connected properly?

The S7-LAN can also be used for controlling/checking the MPI/Profibus. It will be plugged on the Bus so that you can take a look at the status of the busses via software on PC, for example the
numbers of parity errors.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2,5 watt |
Display: | double lined LCD-display |
Handling/Configuration: |
Kabelmanager-Software keypad on the back |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
10/100MBit ethernet interface |
Galvanic separation: | 1500V PPI/MPI/Profibus to the PC |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 146 x 41 x 29 mm |
Scope of delivery: | |
MPI-LAN-cable Power connector 2pins small |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
25,- €
plus VAT. and shipping
plus VAT. and shipping
35,- €
plus VAT. and shipping
plus VAT. and shipping
5,- €
plus VAT. and shipping
plus VAT. and shipping
5,- €
plus VAT. and shipping
plus VAT. and shipping
315,- €
plus VAT. and shipping
plus VAT. and shipping
415,- €
plus VAT. and shipping
plus VAT. and shipping
3,- €
plus VAT. and shipping
plus VAT. and shipping
79,- €
plus VAT. and shipping
plus VAT. and shipping
9352-S7-BK
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x

39,- €
plus VAT. and shipping
plus VAT. and shipping
143,- €
plus VAT. and shipping
plus VAT. and shipping
10,- €
plus VAT. and shipping
plus VAT. and shipping
9391-USB
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m

89,- €
plus VAT. and shipping
plus VAT. and shipping
39,- €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
Variationen:
LAN

smallest simatic S7 ethernet gateway with PD-socket, multifunctional, 1 adapter for all PPI, MPI and Profibus applications
with ext. 24V-connector
easy remote maintenance over internet

Simatic S7 ethernet gateway with Wifi for PPI/MPI/Profibus
All prices plus costs of delivery, shipping insurance and VAT.
9352-LANCON
S7-LAN connector for Siemens S7 PLC controller
Simatic S7 network adapter for PPI-MPI-PROFIBUS / network for every S7 controller in less than 3 minutes
S7-LAN connector for Siemens S7 PLC controller
Simatic S7 network adapter for PPI-MPI-PROFIBUS / network for every S7 controller in less than 3 minutes

399,- €
plus VAT. and shipping
plus VAT. and shipping
299,- €
plus VAT. and shipping
plus VAT. and shipping
178,- €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions

390,- €
plus VAT. and shipping
plus VAT. and shipping
39,- €
plus VAT. and shipping
plus VAT. and shipping
125,- €
plus VAT. and shipping
plus VAT. and shipping