S7-GATE connector with integrated firewall for Siemens S7-PLCs
Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
with LCD-display
Features:- S7-PLC-Firewall in the form of a bus plug
- Monitors/regulates Network-accesses on the connected PPI-, MPI- Profibus
- Display of PLC diagnostic buffer in the WebServer
- Built-in PG diagnostic socket
- Parameterization via integrated WebServer
- Standard functions like S7-LAN connector
The PLC-firewall monitors:
more...
variants:
ARTNR: 9350
MPI+PPI+HMI+TS - Interfacecable 3m
Obsolete
214,00 € plus VAT. and shipping
ARTNR: 9350
MPI+PPI+HMI+TS - Interfacecable 3m
Obsolete
EAN number: | 4260363241304 | |
HS-code: | 85444290 | |
Weight: | 0.5 kg |
S7
PPI-Bus | |||||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||||
USB | |||||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||||
LAN | |||||||||
10/100BaseTx |
x(7)
|
x
|
x
|
x
|
x
|
||||
WIFI | |||||||||
2.4 GHz |
x
|
||||||||
TeleService operation | |||||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||||
baud rates at TS-operation directly at the PC | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||||
baud rates at TS-operation directly with a modem | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x
|
x
|
|||||||
115.2 KBit/s |
x
|
x
|
|||||||
HMI | |||||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||||
PLCVCOM |
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
RFC1006 |
8
|
8
|
32
|
32
|
32
|
||||
AG connections (maximum) | |||||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||||
integrated PLC-firewall |
|
|
x
|
x
|
x
|
||||
display diagnostic-buffer in the webbrowser |
|
|
x
|
x
|
x
|
||||
webserver for configuration |
x
|
x
|
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
x
|
x
|
||||
galvanic separation | |||||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
1,5KV
|
1,5KV
|
mounting | |||||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||||
upgrading with | |||||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||||
supports | |||||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win11 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1 (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3 (3) only serial communication (4) Siemens Step7 V5.2 and higher dont run with this operationing system (5) USB-communication is only possible with the special driver for Win NT (6) USB 2.0 is backward compatible to 1.1 (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation (8) only in combination with the MPI-Speed-driver („continously-active“) (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional) (11) only in the mode: MultiMaster-Mode (12) up to a maximum baud rate of 187.5 KBit/s (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port. (14) with the use of the TS-adapter / item number: 9350.TS (15) Update directly with PC and TIC-driver (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens (19) only at PPI-communication possible (20) Only with TIC-driver (21) with integrated webserver possible (22) No support of Siemens Step7-software possible (23) Only with USB and with TIC-driver |
Features:
The PLC-firewall monitors:
- S7-PLC-Firewall in the form of a bus plug
- Monitors/regulates Network-accesses on the connected PPI-, MPI- Profibus
- Display of PLC diagnostic buffer in the WebServer
- Built-in PG diagnostic socket
- Parameterization via integrated WebServer
- Standard functions like S7-LAN connector
The PLC-firewall monitors:
- IP-addresses, i.e. it determines which IP-address is allowed to access the connected bus and which is not
- Write/read access to variables/data areas of the individual bus-participants
- PG functions allowed/prohibited depending on the IP-address
Serial programming of the S7- PLC
With the MPI/PPI-cable you have the ability to access a connected SPC-PLC S7-200 (PPI 9600 Baud and 19200 Baud) as well as S7-300/400 (MPI/Profbus 9600 Baud up to 187500 Baud) via PC serial with up
to 115200 Baud for reading respectively writing of data.
Remote maintenance with TS-software without original TS-adaptor
You have to reach urgend your PLC via remote maintenance and have no TS-adaptor in your company? No problem, configure with the MPI-Kabelmanager your S7-interface-cable MPI/PPI-Kabel the mode "TS"
for "remote maintenance", connect this cable with the TS-Adapter (article number 9350-TS) with a standard modem and send it all to your client. Now you will be able to start the connection with
your TS-sofware and solve the problem. And this all without buying a original TS-adapter.
Visualisation of your S7- PLC via COM-Port
Your panel provides a serial port and no MPI/Profibus for connecting a S7-PLC. Connect the MPI/PPI-cable with it and you’re Online with your panel.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2 watt |
Display: | double lined LCD-display |
Handling/Configuration: | Kabelmanager-Software |
Interfaces: |
to the PLC:
PPI/MPI-bus interface: 9,6 KBd - 187,5 KBd
to the PD/PC:
RS232: 9,6 KBd - 115,2 KBd |
Galvanic separation: | 1000V PPI/MPI-bus to the PC |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 146 x 41 x 29 mm |
Scope of delivery: | MPI/PPI-cable |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
166,00 €
plus VAT. and shipping
plus VAT. and shipping
84,00 €
plus VAT. and shipping
plus VAT. and shipping
9391-HH
DIN-rail-holder for MPI/PPI
quick and easy assembling on the cap rail
DIN-rail-holder for MPI/PPI
quick and easy assembling on the cap rail
9350-WAND
Wall-mounting
for MPI/PPI + MPI-II + MPI-USB
Wall-mounting
for MPI/PPI + MPI-II + MPI-USB
48,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-104-2
MPI-PC104-card 2 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
MPI-PC104-card 2 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
9352-104
MPI-PC104-card 1 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
MPI-PC104-card 1 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
6,00 €
plus VAT. and shipping
plus VAT. and shipping
37,00 €
plus VAT. and shipping
plus VAT. and shipping
9350-4-ON
Power-adapter for MPI-cable
without power-supply unit
Power-adapter for MPI-cable
without power-supply unit
9350-4
Power-adapter for MPI-cable
with power-supply unit 100-240VAC
Power-adapter for MPI-cable
with power-supply unit 100-240VAC
32,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-S7-BK
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
42,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
214,00 €
plus VAT. and shipping
plus VAT. and shipping
222,00 €
plus VAT. and shipping
plus VAT. and shipping
236,00 €
plus VAT. and shipping
plus VAT. and shipping
251,00 €
plus VAT. and shipping
plus VAT. and shipping
219,00 €
plus VAT. and shipping
plus VAT. and shipping
RS232
MPI-II
Universal S7interface-cable +++ RS232/USB to PPI/MPI/PROFIBUS +++ For HMI-USB applications +++ Bus-status on display
Universal S7interface-cable +++ RS232/USB to PPI/MPI/PROFIBUS +++ For HMI-USB applications +++ Bus-status on display
S5toMPI
Connects the S5-PLC with a S7-PLC
Connects the S5-PLC with a S7-PLC
All prices plus costs of delivery, shipping insurance and VAT.
55,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-LANCON
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
423,00 €
plus VAT. and shipping
plus VAT. and shipping
9350-9-DIAG
DiagConn 90° Highend-connector
for PROFIBUS with diagnosis function country of origin: Germany not preferential
DiagConn 90° Highend-connector
for PROFIBUS with diagnosis function country of origin: Germany not preferential
54,00 €
plus VAT. and shipping
plus VAT. and shipping
479,00 €
plus VAT. and shipping
plus VAT. and shipping
359,00 €
plus VAT. and shipping
plus VAT. and shipping