Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK
S7-GATE connector with integrated firewall for Siemens S7-PLCs - Process Informatik Entwicklungsgesellschaft mbH

S7-GATE connector with integrated firewall for Siemens S7-PLCs Produktvideo anzeigen Download


Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer

Ethernetmodule for PPI/MPI/Profibus

Features:
  • S7-PLC-Firewall in the form of a bus plug
  • Monitors/regulates Network-accesses on the connected PPI-, MPI- Profibus
  • Display of PLC diagnostic buffer in the WebServer
  • Built-in PG diagnostic socket
  • Parameterization via integrated WebServer
  • Standard functions like S7-LAN connector

The PLC-firewall monitors:

    more...
    variants:

    423,00 € plus VAT. and shipping

    ARTNR: 9352-LANCON
    S7-LAN connector for Siemens S7 Controller
    EAN number: 4260363240017
    HS-code: 85423190
    Weight: 0.06 kg



    S7

    PPI-Bus
    PPI 9.6 KBit/s - 19.2 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Multimaster 9.6 KBit/s - 187.5 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    MPI-Bus
    19.2 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    187.5 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    1.5 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    Profibus
    9.6 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    19.2 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    45.45 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    93.75 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    187.5 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    x
    500 KBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    1.5 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    3.0 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    6.0 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    12.0 MBit/s
    x
    x
    x
    x
    x
    x
    x
    x
    Profibus-profile
    DP
    x(12)
    x
    x
    x
    x
    x
    x
    x
    x
    standard
    x(12)
    x
    x
    x
    x
    x
    x
    x
    x
    universal(DP/FMS)
    x
    x
    x
    x
    x
    x
    x
    x
    RS 232
    9.6 KBit/s
    x(19)
    x(19)
    19.2 KBit/s
    x
    x
    38.4 KBit/s
    x
    x
    57.6 KBit/s
    x(9)
    x(9)
    115.2 KBit/s
    x(9)
    x(9)
    USB
    USB 1.1 (6)
    x(1)
    x
    x(2)
    LAN
    10/100BaseTx
    x(7)
    x
    x
    x
    x
    WIFI
    2.4 GHz
    x
    TeleService operation
    with S7-300/400
    x(14)(18)
    x(14)(18)
    baud rates at TS-operation directly at the PC
    9.6 KBit/s
    x
    x
    19.2 KBit/s
    x
    x
    38.4 KBit/s
    x(8)
    x(8)
    57.6 KBit/s
    x(8)
    x(8)
    baud rates at TS-operation directly with a modem
    9.6 KBit/s
    x
    x
    19.2 KBit/s
    x
    x
    38.4 KBit/s
    x
    x
    57.6 KBit/s
    x
    x
    115.2 KBit/s
    x
    x
    HMI
    9.6 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    19.2 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    38.4 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    57.6 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    115.2 KBit/s
    x
    x
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    x(13)
    update
    firmware-update
    x(10)
    x(10)
    x(15)
    x(15)
    x(15)
    x(15)
    x(15)
    x(15)
    x(15)
    input/online help                  
    keypad
    x
    x
    x
    x(21)
    x(21)
    x(21)
    x(21)
    display
    x
    x
    x
    x
    x(21)
    x(21)
    x(21)
    x(21)
    PD connections (maximum)                  
    PLCVCOM
    1
    1
    1
    1
    1
    1
    1
    1
    RFC1006
    8
    8
    32
    32
    32
    AG connections (maximum)
    passive subscriber
    1
    15
    15
    15
    15
    15
    15
    15
    15
    active subscriber
    126
    126
    126
    126
    126
    126
    126
    126
    126
    more functions                  
    integrated PLC-firewall
    x
    x
    x
    display diagnostic-buffer in the webbrowser
    x
    x
    x
    webserver for configuration
    x
    x
    x
    x
    x
    Remote access over existing VPN-channel
    x
    x
    x
    x
    x
    Access via existing WLAN-channel
    x
    x
    x
    x
    x
    status/control variable
    x
    x
    x
    x
    x
    S7 on S7/S5 DB exchange
    x
    x
    x
    x
    x
    S5 on MPI DB exchange
    only as S5toMPI
    S7 on MPI (Send/Fetch)
    x
    x
    x
    x
    x
    Profinet Gateway
    x
    x
    x
    x
    x
    Time in PLC from NTP-server
    x
    x
    x
    x
    x
    galvanic separation                  
    to the bus (screen connected through)
    1KV
    1KV
    1KV
    1,5KV
    1KV
    1,5KV
    1,5KV
    1,5KV
    1,5KV
    mounting                  
    wall monuting
    (with opt. wall mounting-set)
    x
    x
    x
    x
    upgrading with
    CheapConn+cable
    x
    x
    x
    x
    supports
    WIN 98
    x
    x(3)
    x
    x
    x
    x
    x
    WIN 98 SE
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN ME
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN NT
    x
    x(5)
    x(5)
    x
    x(5)
    WIN 2000
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN XP Home (4)
    x
    x
    x
    x
    x
    x
    x
    x
    x
    WIN XP Professional
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Vista(32bit)
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Win7(32bit)
    x
    x
    x
    x
    x
    x
    x
    x
    x
    Win7(64bit)
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    Win8/8.1
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    Win10
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    Win11
    (22)
    x(23)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)
    x(20)

    (1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1
    (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3
    (3) only serial communication
    (4) Siemens Step7 V5.2 and higher dont run with this operationing system
    (5) USB-communication is only possible with the special driver for Win NT
    (6) USB 2.0 is backward compatible to 1.1
    (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch
    with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation
    (8) only in combination with the MPI-Speed-driver („continously-active“)
    (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility
    (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the
    Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional)
    (11) only in the mode: MultiMaster-Mode
    (12) up to a maximum baud rate of 187.5 KBit/s
    (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port.
    (14) with the use of the TS-adapter / item number: 9350.TS
    (15) Update directly with PC and TIC-driver
    (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens
    (19) only at PPI-communication possible
    (20) Only with TIC-driver
    (21) with integrated webserver possible
    (22) No support of Siemens Step7-software possible
    (23) Only with USB and with TIC-driver

    Remote maintenance

    TELE LINK NETWORK
             
     
    secured modem-protocol
    additional software needed
    Siemens TS -Software
    Siemens TS -Software
    VPN-Client
    VPN-Client
    Providing WinTELEPROF-software
    modem
    analogue/ISDN
    analogue
    opt. via PCMCIA
    analogue/GSM
    analogue/ISDN/GSM
    internet-connection
    internet-connection
    internet-connection
    modem for world wide use
    interfaces
    MPI/Profibus
    9600-12MBd
    9600-12MBd
    9600-12MBd
    9600-12MBd
    RS232
    2x
    2x
    2x
    1x
    1x
    TTY
    2x
    2x
    2x
    1x
    PCMCIA
    2x (optionally)
    1x
    1x
    Ethernet
    10/100BaseTx
    1x
    1x
    5x
    USB
    2x
    1x
    LCD-display
    instead 10 LEDs
    instead status-LED
    instead webserver
    instead webserver
    supported PLC-protocols *
    S7
    S5
    ✓ (optional)
    ✓ (optional)
    Pilz PSS
    ✓ (optional)
    ✓ (optional)
    Allen-Bradley
    ✓ (optional)
    ✓ (optional)
    AEG
    ✓ (optional)
    ✓ (optional)
    Bosch
    ✓ (optional)
    ✓ (optional)
    Telemecanique
    ✓ (optional)
    ✓ (optional)
    GE-Fanuc
    ✓ (optional)
    ✓ (optional)
    Klöckner-Moeller
    ✓ (optional)
    ✓ (optional)
    Mitsubishi
    ✓ (optional)
    ✓ (optional)
    SMS-sending/Pager(S5/S7)
    ✓ (no pager)
    only for analogue / ISDN
    HMI-messaging module(S5/S7)
    SMS-receive with GSM
    DTMF with analogue
    e-mail-dispatch
    FAX-dispatch(S5/S7)
    ✓ (optional)
    ✓ (optional)
    only for analogue / ISDN
    PLC-data coupling(S5/S7)
    ✓ (optional)
    ✓ (optional)
    ASCII-transfer from S5/S7
    ✓ (optional)
    ✓ (optional)
    only with ASCII-LAN
    internet-coupling
    Usage as dial-up-router
    power supply
    24V/DC
    24V/DC
    24V/DC
    24V/DC
    24V/DC
    24V/DC
    24V/DC
    24V/DC
    dimensions w x h x d (in mm)
    High: 67 x 280 x 170
    FLAT: 300 x 175 x 70
    300 x 175 x 66
    235 x 162 x 37
    90 x 162 x 54
    40 x 125 x 115
    42 x 15 x 65
    65 x 43 x 17
    154 x 92 x 28

    * other PLC types on request

    Mihas GmbH Intelligente Lösungen
    Bad Waldsee
    www.mihas.com

    Götz-Automation
    Heiligkreuzsteinach
    www.goetz-automation.de

    renntronic GmbH
    48155 Münster
    www.renntronic.de

    KK Engineering*Wolfgang Klein
    47495 Rheinberg
    www.kk-engineering.de

    MSR-SERVICE GmbH
    Mansfeld
    www.msr-online.de

    Karl Roll GmbH & Co. KG
    Mühlacker - Enzberg
    www.karl-roll.de

    Appenzeller Engineering
    Uedem
    www.appenzeller-engineering.de

    Wöhrle Belgium B.V.B.A.
    Mechelen , Belgium
    www.wohrle.be

    Ing. Roland Grabner - Technisches Büro
    Salzburg , Austria
    https://www.grabner-automation.at/

    Frank Hoffmann & Co.GmbH
    Gau-Odernheim
    www.frank-hoffmann-gmbh.de

    Baier Stefan Computerservice
    Finsterwalde
    www.baier-computer.de

    Hediger Elektro AG
    Menziken , Switzerland
    www.hedag.ch

    PCS Process Control Solutions GmbH
    Bochum
    www.process-control.solutions

    Innovacion Integral de
    Queretaro, QRO , Mexico
    www.innovaautomation.com.mx

    Klaus Wellen GmbH
    Bielefeld
    www.klaus-wellen.de

    Vitalik Automation
    Versmold
    www.vitalik-automation.de

    InSteGa GmbH & Co. KG
    Erkelenz
    www.InSteGa.de

    system engineering GmbH ilmenau
    Ilmenau
    www.sei-gmbh.de

    IBEA Jens Nitschke Ingenieurbüro für Elektrotechnik und Automation
    Zeulenroda-Triebes
    www.ibea-zr.de

    Junger GmbH
    Gütersloh
    www.junger-gmbh.de
    Features:
    • S7-PLC-Firewall in the form of a bus plug
    • Monitors/regulates Network-accesses on the connected PPI-, MPI- Profibus
    • Display of PLC diagnostic buffer in the WebServer
    • Built-in PG diagnostic socket
    • Parameterization via integrated WebServer
    • Standard functions like S7-LAN connector

    The PLC-firewall monitors:
    • IP-addresses, i.e. it determines which IP-address is allowed to access the connected bus and which is not
             
    • Write/read access to variables/data areas of the individual bus-participants
             
    • PG functions allowed/prohibited depending on the IP-address
             
    Extend MPI/DP-bus over network or convert to network
    Produkbild

    MPI/DP communication between two S7-300/400 controllers on the same bus
    - a control is relocated spatially:
    2x S7-LAN with activated X_PUT/X_GET module, the data is transported between the modules via the network.
    - a control is replaced by a PN control:
    1x S7-LAN with activated X_PUT/X_GET module and the received-data are transferred automatically to the configured PN-PLC via PUT/GET.

    Global data communication (MPI) also with network-PLC
    Produkbild

    Running global-data-communication between MPI-PLCs (S7-300/400), is one of these PLCs replaced with a newer PLC with network-interface (S7-1200/1500), this PLC was not able to access this data.
    Simply configure the global-data of the “old” PLC via the web-server in the S7-LAN-module. Enter the new PLC as a TCPIP-connection-partner and the module writes/reads the data via PUT/GET from this network-PLC and passes it on as before.

    Address all S7-PLCs (no matter which type) via S7-TCPIP
    Produkbild

    Networking of all S7-controllers (S7-200/300/400), for example with your production-data-acquisition, Industry 4.0 (OPC Server UA or Classic), panels and other devices that communicate via S7-TCPIP RFC1006. One module for all bus-types: PPI, MPI and Profibus.
    Even the very old "S7-200" with a pure PPI-protocol can be used, regardless of the firmware version!

    Informations about the bus
    Produkbild

    View information from the connected bus-system in plain text without using the Simatic-Manager or TIA-Portal. With the connection-menu you get the list of reachable nodes, marked in color whether it is an "active bus-participant", is a "candidate for inclusion in the bus" or a "passive bus-participant".
    You can also see whether cyclic bus-parameter-protocols have been received, you are "in the bus" yourself, the bus-address of the participant recognized as a "direct participant" (on which the S7-LAN is located) and whether the contained modules such as "variable control", "gateway-coupling",... actively communicate.

    Connecting S7-PLCs without head-station
    Produkbild

    Direct data-exchange between S7-PLCs with S7-LAN.
    Thanks to active PUT/GET directly in the module without superordinate head control!
    Transfer data directly from one MPI/Profibus-PLC to another.
    Bus independent! MPI-bus <--> Profibus / Profibus <--> Profibus / MPI-bus <--> MPI-bus

    Connecting S7-/S5-PLCs without head-station
    Produkbild

    Pair your S7 directly with your S5, thanks to the active PUT/GET in the S7-LAN no problem.
    Each MPI/Profibus-CPU exchanges data directly without using a CP.
    No head-control or changes in the S5-PLC needed.

    Data backup S7-PLC over MPI/Profibus on FTP-server
    Produkbild

    S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on FTP-server

    Data backup S7-PLC over MPI/Profibus on FTP-server via dig. IO
    Produkbild

    Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to FTP-server

    Data backup S7-PLC over MPI/Profibus on SD-card
    Produkbild

    S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on SD-card

    Data backup S7-PLC over MPI/Profibus on SD-card via dig. IO
    Produkbild

    Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to SD-card

    Data backup S7-PLC over MPI/Profibus on USB-stick
    Produkbild

    S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on USB-stick

    Data backup S7-PLC over MPI/Profibus on USB-stick via dig. IO
    Produkbild

    Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to USB-stick

    S7-300/400 (MPI/DP) to S5
    Produkbild

    Coupling S7-controller with MPI/Profibus at S5-control with PD-port via network

    S7-300/400 (MPI/DP) to S7-300/400 (MPI/DP)
    Produkbild

    Coupling S7-controller with MPI/Profibus at S7-controller with MPI/Profibus via network

    S7-1200/1500 to S5
    Produkbild

    Coupling S7-controller with PN-port at S5-controller with PD-port via network

    S7-1200/1500 to S7-300/400 (MPI/DP)
    Produkbild

    Coupling S7-controller with PN-port at S7-controller with MPI/Profibus via network

    Remote-maintenance Siemens-S7-PLC with MPI/Profibus with firewall
    Produkbild

    Remote-maintenance of a Siemens-S7-controller with S7-LAN on MPI/Profibus via secure VPN-tunnel and scalable firewall

    Remote-maintenance Siemens-S7-PLC with MPI/Profibus
    Produkbild

    Remote-maintenance of a Siemens-S7-controller with S7-LAN on MPI/Profibus via secure VPN-tunnel of the TeleRouter

    Remote-maintenance Siemens-S7-PLC with MPI/Profibus over VPN-server
    Produkbild

    Remote-maintenance of a Siemens-S7-controller with S7-LAN on MPI/Profibus over separate VPN-server

    Wireless around the S7-PLC
    Produkbild

    Move wirelessly around the S7-PLC and communicate for example ONLINE in the status

    Connect MPI / Profibus with current network panels
    Produkbild

    Visualize with the latest S7 network panels directly on your MPI Profibus.
    No PLC change necessary.
    Connect several nodes at the same time via a network module.
    Simultaneous access from different systems possible.

    Link S7-TCP-IP Panel to MPI Profibus over WiFi
    Produkbild

    Use the latest S7-TCP-IP panels for your MPI / Profibus.
    Thanks to WLAN also usable for mobile platforms or cranes.
    Connect several nodes at the same time via a network module.
    Simultaneous access from different systems possible.

    Link S7-TCP-IP Panel to MPI Profibus over WiFi
    Produkbild

    Use the latest S7-TCP-IP panels for your MPI / Profibus.
    Thanks to WLAN also usable for mobile platforms or cranes.
    Connect several nodes at the same time via a network module.
    Simultaneous access from different systems possible.

    Programming of S7-PLC-devices via LAN
    Produkbild

    S7-PLC with PPI, MPI, Profibus connection, but data should be read/written via network?
    Ethernet-CP cannot be used because of the effort (hardware-configuration), price, space in the rack, availability. Plug S7-LAN-module/MPI-LAN-cable into a free bus-connector, assign the IP-address and the PLC can be reached via the network. There is no need to invest any more effort. The adapter can be parameterized via an integrated web-server or a configuration-tool. No changes to the S7-PLC are necessary to operate the adapter.
    The adapter can also be used to implement PUT/GET-connections to other controls, but the PLC-program must be changed for this. Other PLCs can just as well read/write data from this controller via PUT/GET; nothing needs to be changed in the PLC program.
    Automation very easy: Connect, parameterize and work.

    Watching of S7-PLC-devices via LAN without Ethernet-CP
    Produkbild
    Your panel only has a LAN-socket as PLC-interface? No problem, connect this socket with the S7-LAN or the MPI-LAN-cable and plug it directly on the PPI/MPI/Profibus of the PLC. Then access to the variables and data of the PLC is already available.
    S7-CP-replacement (without LAN-CP to the PLC-device)
    Produkbild
    Do you have a S7-PLC-device without CP243-1, CP343-1 or CP443-1 and would like to connect via LAN? Then plug the S7-LAN on the PLC-device and your access via RFC1006 is ready for use.
    Remote maintenance of your S7-PLC-device via LAN / Internet
    Produkbild
    You have access to a on-site network and your PLC-device has no LAN-connection? No problem, plug the S7-LAN on the PLC-device and you will have immediate access to the PLC from afar.
    Without LAN-cable round of the PLC
    Produkbild

    Your’re right in the middle of your production line and and should move around the machine and simultaneously observe / manage. No problem, you parameterize the ALF, connect to the S7-LAN and connect to the WIFI-network of the ALF and are ONLINE on the PLC.

    Transformation of Rack/Slot in TSAP to MPI-address
    Produkbild
    Your panel or visualisationsystem addresses the used PLC with Rack/Slot in TSAP? No problem, activate this mode in the S7-LAN and you will get actual data from the PLC.
    PLC coupling (data exchange between PLC-devices)
    Produkbild
    Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Thereto no dedicated line is required, it’s sufficient when the stations connect via network (DSL-router).
    Actual time for the PLC?
    Produkbild
    You need in your PLC a actual time? No problem, with the NTP-function the S7-LAN-module get from a NTP-(Time-)Server the actual time and transfers it direct into the configured PLC or for processing in a DB.
    Variable-chart without Step7-programming package
    Produkbild
    You would like to give your customer the opportunity to read current numbers of the manufacturing Online, without installing a visualisation or even the STEP7-package? Then a S7-LAN with the option „Status Variable“ is needed, and your customer can take a look at these password protected data on a site of the integrated webserver.
    Malfunctions on the Bus although everything is (apparently) connected properly?
    Produkbild
    The S7-LAN can also be used for controlling/checking the MPI/Profibus. It will be plugged on the Bus so that you can take a look at the status of the busses via software on PC, for example the numbers of parity errors.
    Supply voltage: 24V DC +/- 20%
    Power consumption: 2 watt
    Display: Web-Browser
    2 status-LEDs
    Handling/Configuration: Web-Browser
    TIC-Software
    Interfaces:
    to the PLC:
    PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
    to the PD/PC:
    PD/diagnosis jack
    10/100BaseTX RJ45-ethernet jack (auto select)
    Galvanic separation: 1500V PPI/MPI/Profibus to the PC
    Operating systems: MS-Windows NT, 2000, XP, Vista / Win7/8/10/11 32/64 Bit
    Protocols: RFC1006, DHCP, HTTP
    Operating temperature: 0 - 55°C
    Case: ABS-plastic case
    Dimensions: 65 x 43 x 17 mm
     
    Scope of delivery: S7-LAN-module
    Power connector 2pins small
    All prices plus costs of delivery, shipping insurance and VAT.

    accessories:

    9391.1
    24V DC power-supply unit 625mA

    Primary 110V - 240 VAC Euro+USA-plug
    Quickbestellung INFOMAIL
    by e-mail
    59,00 €
    plus VAT. and shipping


    9391-USB
    USB-powercable for 24V DC, max. 3W

    USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
    Quickbestellung INFOMAIL
    by e-mail
    95,00 €
    plus VAT. and shipping


    84,00 €
    plus VAT. and shipping


    9636-CROSS
    Cross-cable 3m Cat5+, shielded

    RJ45 plug <=> RJ45 plug, twisted pinning
    9636-TCPIP
    Patch-cable 3m, Cat5+, shielded

    RJ45 plug <=> RJ45 plug, 1:1
    9352-24
    Power connector 2pins small

    cable coupling by screw-connector (small)
    Quickbestellung INFOMAIL
    by e-mail
    4,00 €
    plus VAT. and shipping


    9352-S7-BK
    S7-bus-coupler

    Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
    Quickbestellung INFOMAIL
    by e-mail
    42,00 €
    plus VAT. and shipping


    All prices plus costs of delivery, shipping insurance and VAT.

    9352-LANCON
    S7-LAN connector for Siemens S7 PLC controller

    Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
    Quickbestellung INFOMAIL
    by e-mail
    423,00 €
    plus VAT. and shipping




    maximum 3 articles
    9352-S7-WIFI
    S7-BRIDGE

    Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI
    Quickbestellung INFOMAIL
    by e-mail
    741,00 €
    plus VAT. and shipping




    maximum 3 articles
    9352-S7-GATE
    S7-GATE connector with integrated firewall for Siemens S7-PLCs

    Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
    Quickbestellung INFOMAIL
    by e-mail
    499,00 €
    plus VAT. and shipping




    maximum 3 articles
    9352-LANCON++
    S7-LAN++ connector for Siemens S7 Controller

    Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
    Quickbestellung INFOMAIL
    by e-mail
    423,00 €
    plus VAT. and shipping




    maximum 3 articles

    Internet

    TeleRouter
    The simple and quick router solution for automation

    LAN

    MPI-LAN
    S7-cable PPI/MPI/PROFIBUS +++ Ethernet-gateway S7 as cable +++ Network for each S7-PLC +++ Parallel LAN access +++ Ethernet for each S7-PLC

    Diagnosis

    S5-DIAG
    Quick and comfortable debugging for the PLC and the bus

    Products for the LOGO! - controls

    EtherSens
    Networked via LAN - WIFI - LTE
    Worldwide access from any device possible
    Internal and external data-storage
    Simple rail-mounting
    Sending eMail with LOGO!-Control
    Sending SMS with LOGO!-Control
    Process energy-data with LOGO!-Control
    S7-BRIDGE
    Online with S7-PLC wo. cables +++ S7-adapter Ppi/Mpi/Profibus/Pn +++ No wifi-infrastructure +++ Integrated access-point +++ Ppi/Mpi/Dp/Pn - Lan - Wifi
    CONNECT devices
    Remotesupport without configuration / Machine access without IT
    Emergency-package remote-maintenance S5 and S7
    For you completely configured, just plug it in and you are connected

    Internet-coupling/communication

    CONNECT devices
    Remotesupport without configuration / Machine access without IT
    S5-LAN++
    Network-connection for the S5-PLC +++ Network to PG-interface +++ Of developer and manufacturer +++ Remotemaintenance via Internet +++ S5 (CP-343-1 compatible)
    ALF-UA
    Industrial WLAN-Router +++ High-speed datarate 150 Mbit/s +++ Integrated firewall +++ Din-rail-mounting +++ Make your own WIFI
    TeleRouter
    The simple and quick router solution for automation
    S7-GATE
    S7-adapter PPI/MPI/PROFIBUS +++ including PLC-firewall +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
    S7-GATE
    S7-adapter PPI/MPI/PROFIBUS +++ including PLC-firewall +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
    S7-LAN++
    S7-LAN++ Connector with integrated firewall for Siemens S7-PLCs
    All prices plus costs of delivery, shipping insurance and VAT.

    9359-LAN
    S5-LAN++

    Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
    Quickbestellung INFOMAIL
    by e-mail
    452,00 €
    plus VAT. and shipping


    9359-1
    PG-USB-cable 3m for Siemens S5 Controller

    for PLC's + LED + metal case
    Quickbestellung INFOMAIL
    by e-mail
    145,00 €
    plus VAT. and shipping


    9636-CROSS
    Cross-cable 3m Cat5+, shielded

    RJ45 plug <=> RJ45 plug, twisted pinning
    Quickbestellung INFOMAIL
    by e-mail
    11,00 €
    plus VAT. and shipping


    9391.1
    24V DC power-supply unit 625mA

    Primary 110V - 240 VAC Euro+USA-plug
    Quickbestellung INFOMAIL
    by e-mail
    59,00 €
    plus VAT. and shipping