S7-GATE connector with integrated firewall for Siemens S7-PLCs - Process Informatik Entwicklungsgesellschaft mbH

S7-GATE connector with integrated firewall for Siemens S7-PLCs


Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer

OEM - Version (all accessories optional)
without PCMCIA-Slot for UMTS-/LAN-card

Features:
  • S7-PLC-Firewall in the form of a bus plug
  • Monitors/regulates Network-accesses on the connected PPI-, MPI- Profibus
  • Display of PLC diagnostic buffer in the WebServer
  • Built-in PG diagnostic socket
  • Parameterization via integrated WebServer
  • Standard functions like S7-LAN connector

The PLC-firewall monitors:

    more...
    variants:

    1260,00 € plus VAT. and shipping

    ARTNR: 9372-OEM
    TELE-PROFessional II worldwide use
    EAN number: 4260363240062
    HS-code: 85389099
    Weight: 2.05 kg



    Remote maintenance

    TELE LINK NETWORK
             
     
    secured modem-protocol
    additional software needed
    Siemens TS -Software
    Siemens TS -Software
    VPN-Client
    VPN-Client
    Providing WinTELEPROF-software
    modem
    analogue/ISDN
    analogue
    opt. via PCMCIA
    analogue/GSM
    analogue/ISDN/GSM
    internet-connection
    internet-connection
    internet-connection
    modem for world wide use
    interfaces
    MPI/Profibus
    9600-12MBd
    9600-12MBd
    9600-12MBd
    9600-12MBd
    RS232
    2x
    2x
    2x
    1x
    1x
    TTY
    2x
    2x
    2x
    1x
    PCMCIA
    2x (optionally)
    1x
    1x
    Ethernet
    10/100BaseTx
    1x
    1x
    5x
    USB
    2x
    1x
    LCD-display
    instead 10 LEDs
    instead status-LED
    instead webserver
    instead webserver
    supported PLC-protocols *
    S7
    S5
    ✓ (optional)
    ✓ (optional)
    Pilz PSS
    ✓ (optional)
    ✓ (optional)
    Allen-Bradley
    ✓ (optional)
    ✓ (optional)
    AEG
    ✓ (optional)
    ✓ (optional)
    Bosch
    ✓ (optional)
    ✓ (optional)
    Telemecanique
    ✓ (optional)
    ✓ (optional)
    GE-Fanuc
    ✓ (optional)
    ✓ (optional)
    Klöckner-Moeller
    ✓ (optional)
    ✓ (optional)
    Mitsubishi
    ✓ (optional)
    ✓ (optional)
    SMS-sending/Pager(S5/S7)
    ✓ (no pager)
    only for analogue / ISDN
    HMI-messaging module(S5/S7)
    SMS-receive with GSM
    DTMF with analogue
    e-mail-dispatch
    FAX-dispatch(S5/S7)
    ✓ (optional)
    ✓ (optional)
    only for analogue / ISDN
    PLC-data coupling(S5/S7)
    ✓ (optional)
    ✓ (optional)
    ASCII-transfer from S5/S7
    ✓ (optional)
    ✓ (optional)
    only with ASCII-LAN
    internet-coupling
    Usage as dial-up-router
    power supply
    24V/DC
    24V/DC
    24V/DC
    24V/DC
    24V/DC
    24V/DC
    24V/DC
    24V/DC
    dimensions w x h x d (in mm)
    High: 67 x 280 x 170
    FLAT: 300 x 175 x 70
    300 x 175 x 66
    235 x 162 x 37
    90 x 162 x 54
    40 x 125 x 115
    42 x 15 x 65
    65 x 43 x 17
    154 x 92 x 28

    * other PLC types on request

    Karl Roll GmbH & Co. KG
    Mühlacker - Enzberg
    www.karl-roll.de

    Wöhrle Belgium B.V.B.A.
    Mechelen , Belgium
    www.wohrle.be

    Junger GmbH
    Gütersloh
    www.junger-gmbh.de
    Features:
    • S7-PLC-Firewall in the form of a bus plug
    • Monitors/regulates Network-accesses on the connected PPI-, MPI- Profibus
    • Display of PLC diagnostic buffer in the WebServer
    • Built-in PG diagnostic socket
    • Parameterization via integrated WebServer
    • Standard functions like S7-LAN connector

    The PLC-firewall monitors:
    • IP-addresses, i.e. it determines which IP-address is allowed to access the connected bus and which is not
             
    • Write/read access to variables/data areas of the individual bus-participants
             
    • PG functions allowed/prohibited depending on the IP-address
             
    Remote maintenance / telecontrol of PLC
    Produkbild
    Access to the connected PLC takes place by coupling via Analogue-, ISDN-, mixed Analogue-ISDN-, GSM-, UMTS-line and also via Internet with and without VPN-security.
    Analogue and ISDN - how do they come together?
    Produkbild

    You have on the plant side only ISDN for telephone, but in your office there is only an analogue system? No problem, you have to install on the clients side the TP-II and activate there the analogue-emulation in the device. No, the modem signals will be send digitalized over ISDN and you can connect to it. So, you will be able to communicate though the telephone systems are different and your client isn´t forced to install an analogue connection.

    Router - Mode (access to the network without router)
    Produkbild
    The Tele-Prof-II can also be used as a router for access from a PC via dial-up connection, so that a communication with the behind covered network results. Furthermore a network connection can be made with the TP-II <=> TP-II-line, but in doing so the IP-address-root must differ.
    User dependant network access
    Produkbild
    You have PLC/LAN-participants different supplier in your network and everybody should have access to this network? No problem, you give every supplier a VPN-username and passwort, define in the destination device a user-dependent network-access and after positiv login he only can communicate to the released ip-addresses.
    Separate your machine-net from the office-net
    Produkbild
    You need a separation between the machine-net and the office-net? No problem, plug a PCMCIA-LAN-card in your Tele-Prof-II-device (only for version -H) and the separation is OK. You have access to both nets via remote maintenance.
    S7-CP-alternate (without LAN-CP to the PLC)
    Produkbild
    Do you have a PLC without CP343-1 or CP443-1 and a TP-II as remote maintenance device? Then activate the CP-mode of the TP-II and your visualisation goes directly ONLINE via the LAN of the TP-II.
    PLC coupling (data exchange between PLCs)
    Produkbild
    Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Thereto no dedicated line is required, a “normal” telephone connection is sufficient because the devices cut the line after occured message.
    Failure report transmission without any change in the PLC programm
    Produkbild
    Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, as SMS to your mobile phone, to your pager or also via e-mail. And this without an intervention of the PLC-program. Here the variables and actions are stored and processed in the TP-II.
    Failure report transmission released by the PLC
    Produkbild
    Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, as SMS to your mobile phone, to your pager or also via e-mail.
    Remote maintenance of centralized PLC-devices
    Produkbild
    You have many PLC and you want to programm them central on one place? No problem, you have to connect them all to the KOR/MUX-Tele-Switch, connect it with the TP-II and after telephone connect you will be able with the PD-bus-selection of your Step5-software to go ONLINE. Of course the MOR/MUX-Tele-Switch is cascadable, so you can connect up to 30 PLCs to the devices.
    Sending ASCII-data to a PC
    Produkbild
    Your car park or control sends the configuration / capacity utilisation to a PC with a modem, so that the data can be used for further processing.
    Direct-mode "extended serial interface"
    Produkbild
    There is an unsupported control or data logger or converter integrated in your installation which protocol is not supported? No problem, the signs that the PC in the office sends will be transferred via telephone line by the Direct-mode, and on-site reproduced by the TP-II. The way back is identical. So in that case there’s also a communication to the electronic devices available.
    Data logger with FTP-interface
    Produkbild
    You need a data logger which tape-records the specified data of the PLC and you can collect the data via FTP on demand. No problem, TP-II with the option Datalogger is the solution for you.
    Supply voltage: 24V DC +/- 20%
    Power consumption: 15 watt
    Display: expressive LCD display
    5 status LEDs
    Handling/Configuration: integrated keypad
    WEB-Browser
    Interfaces:
    to the PLC:
    PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
    TTY/20mA current loop (AG-TELE aktiv, PLC passiv)
    RS232: 9,6 KBd - 115,2 KBd / fully assigned
    to the PD/PC:
    10/100BaseTX RJ45-ethernet jack
    TTY/20mA current loop (100 % mechanically and electr. compatible)
    RS232: 9,6 KBd - 115,2 KBd / with a 1on1-cable to the PC
    others:
    2xUSB, 2xPCMCIA (only for version -H)
    Integrated modem: 33K6 HIGH-SPEED, V.42/BIS MNP5 analogue modem
    ISDN (Euro ISDN + 1TR6)
    Operating temperature: 0 - 55°C
    Case: powder coated metal case with mounting flange and DIN-rail mounting
    Dimensions: Flat 300 x 175 x 70 mm
    Hoch 67 x 280 x 170 mm
     
    Scope of delivery: Tele-Prof-II
    Power connector 3pins big
    All prices plus costs of delivery, shipping insurance and VAT.

    accessories:

    9352.1
    USB-cable plug/plug type A-A 3m

    USB 1.1 / 2.0 up to 480 MBit
    Quickbestellung INFOMAIL
    by e-mail
    11,00 €
    plus VAT. and shipping


    9359.1:1
    1:1 cable 9pins D-SUB

    D-SUB 9pins (male) <=> D-Sub 9pins (female), 1to1-assignment
    Quickbestellung INFOMAIL
    by e-mail
    28,00 €
    plus VAT. and shipping


    9361-3
    S5-connecting cable 3m

    forTELE-PROF, MINI-/PG-MUX-II
    9361-3.05M
    S5-connecting cable 5m

    for TELE-PROF, MINI-/PG-MUX-II
    9361-3.06M
    S5-connecting cable 6m

    for TELE-PROF, MINI-/PG-MUX-II
    9361-3.10M
    S5-connecting cable 10m

    for TELE-PROF, MINI-/PG-MUX-II
    9370-8-AT
    Special phone-cable for Austria Obsolete

    RJ12 plug <=> telephone plug of Austria
    Quickbestellung INFOMAIL
    by e-mail
    25,00 €
    plus VAT. and shipping


    9370-8-BE
    Special phone-cable for Belgium

    RJ12 plug <=> telephone plug of Belgium
    Quickbestellung INFOMAIL
    by e-mail
    25,00 €
    plus VAT. and shipping


    9370-8-CH
    Special phone-cable for Switzerland Obsolete

    RJ12 plug <=> telephone plug of Switzerland
    Quickbestellung INFOMAIL
    by e-mail
    25,00 €
    plus VAT. and shipping


    9370-8-D/USA
    Phone-cable analogue Germany+USA

    RJ12 plug <=> RJ12 plug with TAE-adapter for Germany
    Quickbestellung INFOMAIL
    by e-mail
    11,00 €
    plus VAT. and shipping


    9370-8-DK
    Special phone-cable for Denmark

    RJ12 plug <=> telephone plug of Denmark
    Quickbestellung INFOMAIL
    by e-mail
    25,00 €
    plus VAT. and shipping


    9370-8-FR
    Special phone-cable for France

    RJ12 plug <=> telephone plug of France
    Quickbestellung INFOMAIL
    by e-mail
    25,00 €
    plus VAT. and shipping


    9370-8-GB
    Special phone-cable for Great Britain

    RJ12 plug <=> telephone plug of Great Britain
    Quickbestellung INFOMAIL
    by e-mail
    25,00 €
    plus VAT. and shipping


    9370-8-ISDN
    Phone-cable ISDN

    RJ45 plug <=> RJ45 plug, assigned 1to1
    Quickbestellung INFOMAIL
    by e-mail
    11,00 €
    plus VAT. and shipping


    9370-8-IT
    Special phone-cable for Italy

    Quickbestellung INFOMAIL
    by e-mail
    25,00 €
    plus VAT. and shipping


    9370-8-NL
    Special phone-cable for Netherlands

    RJ12 plug <=> telephone plug of the Netherlands
    Quickbestellung INFOMAIL
    by e-mail
    25,00 €
    plus VAT. and shipping


    244,00 €
    plus VAT. and shipping


    9370-TAE
    TAE junction box

    analogue telephone box (NFN) for on-wall mounting
    Quickbestellung INFOMAIL
    by e-mail
    22,00 €
    plus VAT. and shipping


    9371-6
    Servicebag

    for TP, TB + TP-II-FLAT
    Quickbestellung INFOMAIL
    by e-mail
    63,00 €
    plus VAT. and shipping


    172,00 €
    plus VAT. and shipping


    9372-24
    Power connector 3pins big

    connector plug lockable by jack with screws
    Quickbestellung INFOMAIL
    by e-mail
    4,00 €
    plus VAT. and shipping


    9372-LANCARD
    Network-card for TP-II Obsolete

    Ethernet networkcard Cardbus PCMCIA 10/100
    Quickbestellung INFOMAIL
    by e-mail
    105,00 €
    plus VAT. and shipping


    9372-UMTS-Ant
    UMTS directional antenna
    external antenna for the UMTS-card
    Quickbestellung INFOMAIL
    by e-mail
    199,00 €
    plus VAT. and shipping


    9379.1
    MPI-/Profibus connecting cable 1m

    connects MPI-modem/TP-II with the S7-PLC
    Quickbestellung INFOMAIL
    by e-mail
    11,00 €
    plus VAT. and shipping


    9391-MT
    Mounting set

    for DIN-rail-holder, self mounting
    Quickbestellung INFOMAIL
    by e-mail
    27,00 €
    plus VAT. and shipping


    9391.1
    24V DC power-supply unit 625mA

    Primary 110V - 240 VAC Euro+USA-plug
    Quickbestellung INFOMAIL
    by e-mail
    59,00 €
    plus VAT. and shipping


    9636-CROSS
    Cross-cable 3m Cat5+, shielded

    RJ45 plug <=> RJ45 plug, twisted pinning
    9636-TCPIP
    Patch-cable 3m, Cat5+, shielded

    RJ45 plug <=> RJ45 plug, 1:1
    All prices plus costs of delivery, shipping insurance and VAT.

    9372-OEM
    TELE-PROFessional II worldwide use

    OEM - Version (all accessories optional) without PCMCIA-Slot for UMTS-/LAN-card
    Quickbestellung INFOMAIL
    by e-mail
    1260,00 €
    plus VAT. and shipping




    maximum 3 articles
    9372-FLAT
    TELE-PROFessional II worldwide use

    flat version / OEM - Version (all accessories optional) without PCMCIA-slot for UMTS-/LAN-card
    Quickbestellung INFOMAIL
    by e-mail
    1260,00 €
    plus VAT. and shipping




    maximum 3 articles
    9372-FLAT-H
    TELE-PROFessional II worldwide use
    flat version / OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
    Quickbestellung INFOMAIL
    by e-mail
    1313,00 €
    plus VAT. and shipping


    9372-OEM-H
    TELE-PROFessional II worldwide use
    OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
    Quickbestellung INFOMAIL
    by e-mail
    1313,00 €
    plus VAT. and shipping


    All prices plus costs of delivery, shipping insurance and VAT.

    9370-8-D/USA
    Phone-cable analogue Germany+USA

    RJ12 plug <=> RJ12 plug with TAE-adapter for Germany
    Quickbestellung INFOMAIL
    by e-mail
    11,00 €
    plus VAT. and shipping


    9352-LANCON
    S7-LAN connector for Siemens S7 PLC controller

    Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
    Quickbestellung INFOMAIL
    by e-mail
    423,00 €
    plus VAT. and shipping


    9359-LAN
    S5-LAN++

    Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
    Quickbestellung INFOMAIL
    by e-mail
    452,00 €
    plus VAT. and shipping


    9379.1
    MPI-/Profibus connecting cable 1m

    connects MPI-modem/TP-II with the S7-PLC
    Quickbestellung INFOMAIL
    by e-mail
    11,00 €
    plus VAT. and shipping


    9359-1.05M
    PG-USB-cable 5m for Siemens S5 Controller

    for PLC's + LED + metal case
    Quickbestellung INFOMAIL
    by e-mail
    174,00 €
    plus VAT. and shipping


    9359-1
    PG-USB-cable 3m for Siemens S5 Controller

    for PLC's + LED + metal case
    Quickbestellung INFOMAIL
    by e-mail
    145,00 €
    plus VAT. and shipping


    Automatic-mode

    Other downloads

    Extension

    Support-videos