S7-USB



smallest USB-gateway for PPI, MPI, Profibus, HMI <=> USB applications
- Supplied driver TIC (Total Integrated Communication) (runs under Win XP, VISTA, Win7/8/8.1, Win10) allows communication and configuration of the interface product
- Function with TIA-Portal and Simatic-Manager, also with WinCC and Comfort Panel
- Automatic protocol- and baud rate detection (depends on the used product from 9K6 to 12M)
- Connects only to the bus when it is requested by PG
- Firmwareupdate via internet for free
- PPI - adapter for S7 - 200
- MPI/Profibus - adapter for S7 - 300 + 400
- CE/EMC compliant construction
- All intelligent MPI-interface-products including a free OPC-server license "OPC-Manager lite" [limited to 100 items]
more...
299,- €
plus VAT. and shipping
plus VAT. and shipping
ARTNR: 9352-S7-USB
S7-USB connector for Siemens S7 Controller
EAN number: | 4260363240000 |
HS-code: | 85444290 |
Weight: | 0.05 kg |
S7
PPI-Bus | |||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||
19.2 KBit/s |
x
|
x
|
|||||
38.4 KBit/s |
x
|
x
|
|||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||
USB | |||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||
LAN | |||||||
10/100BaseTx |
x(7)
|
x
|
x
|
||||
WIFI | |||||||
2.4 GHz |
x
|
||||||
TeleService operation | |||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||
baud rates at TS-operation directly at the PC | |||||||
9.6 KBit/s |
x
|
x
|
|||||
19.2 KBit/s |
x
|
x
|
|||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||
baud rates at TS-operation directly with a modem | |||||||
9.6 KBit/s |
x
|
x
|
|||||
19.2 KBit/s |
x
|
x
|
|||||
38.4 KBit/s |
x
|
x
|
|||||
57.6 KBit/s |
x
|
x
|
|||||
115.2 KBit/s |
x
|
x
|
|||||
HMI | |||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||
PLCVCOM |
1
|
1
|
8
|
1
|
8
|
8
|
|
RFC1006 |
x
|
x
|
x
|
||||
AG connections (maximum) | |||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||
webserver for configuration |
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
||||
galvanic separation | |||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
mounting | |||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||
upgrading with | |||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||
supports | |||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
- Supplied driver TIC (Total Integrated Communication) (runs under Win XP, VISTA, Win7/8/8.1, Win10) allows communication and configuration of the interface product
- Function with TIA-Portal and Simatic-Manager, also with WinCC and Comfort Panel
- Automatic protocol- and baud rate detection (depends on the used product from 9K6 to 12M)
- Connects only to the bus when it is requested by PG
- Firmwareupdate via internet for free
- PPI - adapter for S7 - 200
- MPI/Profibus - adapter for S7 - 300 + 400
- CE/EMC compliant construction
- All intelligent MPI-interface-products including a free OPC-server license "OPC-Manager lite" [limited to 100 items]
- All products, including the examples and demo-version of communication driver as download on the product-site
- Master-class 2 for acyclic services (DPV1)
- With full PD – diagnosis socket
- Power supply from the USB-jack
- Active module, no influence on further bus-clients in the system
Access to MPI/Profibus without power supply

Your’re right in the middle of your production line and are standing in front of a passive assembly just like a switcher or a ET200, in that case you won’t be able to go Online without
an external power supply of your programming adapter, unless you’re using the S7USB. This module is supplied completely from the USB-interface.
Supply voltage: | 5V DC |
Power consumption: | 2 watt |
Display: | 2 status-LEDs |
Handling/Configuration: | Kabelmanager-Software |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
PD/diagnosis jackMini-USB-B-Buchse |
Galvanic separation: | 1000V PPI/MPI/Profibus to the PC |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 65 x 43 x 17 mm |
Scope of delivery: | |
S7-USB-module |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
79,- €
plus VAT. and shipping
plus VAT. and shipping
9352-S7-BK
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x

39,- €
plus VAT. and shipping
plus VAT. and shipping
23,- €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
Variationen:
All prices plus costs of delivery, shipping insurance and VAT.
23,- €
plus VAT. and shipping
plus VAT. and shipping
125,- €
plus VAT. and shipping
plus VAT. and shipping
9352-LANCON
S7-LAN connector for Siemens S7 PLC controller
Simatic S7 network adapter for PPI-MPI-PROFIBUS / network for every S7 controller in less than 3 minutes
S7-LAN connector for Siemens S7 PLC controller
Simatic S7 network adapter for PPI-MPI-PROFIBUS / network for every S7 controller in less than 3 minutes

399,- €
plus VAT. and shipping
plus VAT. and shipping
9350-9-DIAG
DiagConn 90° Highend-connector
for PROFIBUS with diagnosis function country of origin: Germany not preferential
DiagConn 90° Highend-connector
for PROFIBUS with diagnosis function country of origin: Germany not preferential

43,- €
plus VAT. and shipping
plus VAT. and shipping
150,- €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions

390,- €
plus VAT. and shipping
plus VAT. and shipping