S7-BRIDGE - Process Informatik Entwicklungsgesellschaft mbH

S7-BRIDGE Download


Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI

PPI/MPI/Profibus up to 12Mbit/s

Also available as a set for universal use: S5/S7-BRIDGE-WIFI-Sets

Product Overview:
Our S7-BRIDGE is the world's smallest gateway to all your controllers .
Through integrated WIFI and Ethernet interface, in the housing of a Profibus plug, a mobile access to all PLC systems is no problem.
Wireless access to the MPI/DP bus with S7-300/400, PPI with S7-200 or Profinet on all S7-1200/1500 controllers is no longer an obstacle, it offers the possibility of Access to all other network components.
At the same time, the system works as a S7 network adapter for programming, remote maintenance and for coupling the different PLCs.
Thus, both HMI devices, e.g. current panel series , as well as any other S7-Ethernet device, be connected directly via S7-TCP-IP via LAN & WIFI.

! parallel access to MPI/PPI/PROFIBUS !
Quite simply from Siemens TIA, Simatic Step7 Manager, MICROWIN and WinCC projects

more...
479,00 € plus VAT. and shipping

ARTNR: 9352-LAN
MPI-LAN-cable 3m
Obsolete
EAN number: 4260363240949
HS-code: 85444290
Weight: 0.3 kg



S7

PPI-Bus
PPI 9.6 KBit/s - 19.2 KBit/s
x
x
x
x
x
x
x
x
x
Multimaster 9.6 KBit/s - 187.5 KBit/s
x
x
x
x
x
x
x
x
MPI-Bus
19.2 KBit/s
x
x
x
x
x
x
x
x
x
187.5 KBit/s
x
x
x
x
x
x
x
x
x
1.5 MBit/s
x
x
x
x
x
x
x
x
Profibus
9.6 KBit/s
x
x
x
x
x
x
x
x
19.2 KBit/s
x
x
x
x
x
x
x
x
x
45.45 KBit/s
x
x
x
x
x
x
x
x
93.75 KBit/s
x
x
x
x
x
x
x
x
187.5 KBit/s
x
x
x
x
x
x
x
x
x
500 KBit/s
x
x
x
x
x
x
x
x
1.5 MBit/s
x
x
x
x
x
x
x
x
3.0 MBit/s
x
x
x
x
x
x
x
x
6.0 MBit/s
x
x
x
x
x
x
x
x
12.0 MBit/s
x
x
x
x
x
x
x
x
Profibus-profile
DP
x(12)
x
x
x
x
x
x
x
x
standard
x(12)
x
x
x
x
x
x
x
x
universal(DP/FMS)
x
x
x
x
x
x
x
x
RS 232
9.6 KBit/s
x(19)
x(19)
19.2 KBit/s
x
x
38.4 KBit/s
x
x
57.6 KBit/s
x(9)
x(9)
115.2 KBit/s
x(9)
x(9)
USB
USB 1.1 (6)
x(1)
x
x(2)
LAN
10/100BaseTx
x(7)
x
x
x
x
WIFI
2.4 GHz
x
TeleService operation
with S7-300/400
x(14)(18)
x(14)(18)
baud rates at TS-operation directly at the PC
9.6 KBit/s
x
x
19.2 KBit/s
x
x
38.4 KBit/s
x(8)
x(8)
57.6 KBit/s
x(8)
x(8)
baud rates at TS-operation directly with a modem
9.6 KBit/s
x
x
19.2 KBit/s
x
x
38.4 KBit/s
x
x
57.6 KBit/s
x
x
115.2 KBit/s
x
x
HMI
9.6 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
19.2 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
38.4 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
57.6 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
115.2 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
update
firmware-update
x(10)
x(10)
x(15)
x(15)
x(15)
x(15)
x(15)
x(15)
x(15)
input/online help                  
keypad
x
x
x
x(21)
x(21)
x(21)
x(21)
display
x
x
x
x
x(21)
x(21)
x(21)
x(21)
PD connections (maximum)                  
PLCVCOM
1
1
1
1
1
1
1
1
RFC1006
8
8
32
32
32
AG connections (maximum)
passive subscriber
1
15
15
15
15
15
15
15
15
active subscriber
126
126
126
126
126
126
126
126
126
more functions                  
integrated PLC-firewall
x
x
x
display diagnostic-buffer in the webbrowser
x
x
x
webserver for configuration
x
x
x
x
x
Remote access over existing VPN-channel
x
x
x
x
x
Access via existing WLAN-channel
x
x
x
x
x
status/control variable
x
x
x
x
x
S7 on S7/S5 DB exchange
x
x
x
x
x
S5 on MPI DB exchange
only as S5toMPI
S7 on MPI (Send/Fetch)
x
x
x
x
x
Profinet Gateway
x
x
x
x
x
Time in PLC from NTP-server
x
x
x
x
x
galvanic separation                  
to the bus (screen connected through)
1KV
1KV
1KV
1,5KV
1KV
1,5KV
1,5KV
1,5KV
1,5KV
mounting                  
wall monuting
(with opt. wall mounting-set)
x
x
x
x
upgrading with
CheapConn+cable
x
x
x
x
supports
WIN 98
x
x(3)
x
x
x
x
x
WIN 98 SE
x
x
x
x
x
x
x
x
x
WIN ME
x
x
x
x
x
x
x
x
x
WIN NT
x
x(5)
x(5)
x
x(5)
WIN 2000
x
x
x
x
x
x
x
x
x
WIN XP Home (4)
x
x
x
x
x
x
x
x
x
WIN XP Professional
x
x
x
x
x
x
x
x
x
Vista(32bit)
x
x
x
x
x
x
x
x
x
Win7(32bit)
x
x
x
x
x
x
x
x
x
Win7(64bit)
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win8/8.1
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win10
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win11
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)

(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1
(2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3
(3) only serial communication
(4) Siemens Step7 V5.2 and higher dont run with this operationing system
(5) USB-communication is only possible with the special driver for Win NT
(6) USB 2.0 is backward compatible to 1.1
(7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch
with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation
(8) only in combination with the MPI-Speed-driver („continously-active“)
(9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility
(10) Update directly with PC or via Tele-Network if the cable is connected to a device of the
Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional)
(11) only in the mode: MultiMaster-Mode
(12) up to a maximum baud rate of 187.5 KBit/s
(13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port.
(14) with the use of the TS-adapter / item number: 9350.TS
(15) Update directly with PC and TIC-driver
(18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens
(19) only at PPI-communication possible
(20) Only with TIC-driver
(21) with integrated webserver possible
(22) No support of Siemens Step7-software possible
(23) Only with USB and with TIC-driver

Mihas GmbH Intelligente Lösungen
Bad Waldsee
www.mihas.com

Wöhrle Belgium B.V.B.A.
Mechelen , Belgium
www.wohrle.be
Also available as a set for universal use: S5/S7-BRIDGE-WIFI-Sets

Product Overview:
Our S7-BRIDGE is the world's smallest gateway to all your controllers .
Through integrated WIFI and Ethernet interface, in the housing of a Profibus plug, a mobile access to all PLC systems is no problem.
Wireless access to the MPI/DP bus with S7-300/400, PPI with S7-200 or Profinet on all S7-1200/1500 controllers is no longer an obstacle, it offers the possibility of Access to all other network components.
At the same time, the system works as a S7 network adapter for programming, remote maintenance and for coupling the different PLCs.
Thus, both HMI devices, e.g. current panel series , as well as any other S7-Ethernet device, be connected directly via S7-TCP-IP via LAN & WIFI.

! parallel access to MPI/PPI/PROFIBUS !
Quite simply from Siemens TIA, Simatic Step7 Manager, MICROWIN and WinCC projects
Thanks to the integrated TIC driver without project changes.

New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-Firmware-Datei

TIC-(Totally Integrated Communication)-driver for Step7/TIA-Portal for Win XP/VISTA/7/8/10/11 32/64 bit:
TIC firmware / configuration tool / Step7-/TIA-driver

Features:
  • every SIMATIC-S7 (S7-200/300/400) into Network
  • Replacement for CP343-1/443-1, connected directly to MPI or Profibus
  • with Profibus for S7-300 faster than CP343-1
  • fastest installation into Network (less than 3 minutes)
  • automatic detection of baudrate
  • automatic usement of cyclic bus-parameter-protocols
  • no bus-knowledge required / automatic-protocol and baud-rate detection
  • download TIC-driver for STEP-7/TIA-Portal
  • Programming and visualization at the same time (8 connections at the same time)
  • compatible to S7-TCP/IP RFC1006, WinCC (flex), OPC UA with Universal communication Industry 4.0, the IP-S7LINK SDK as well as all common OPC-servers
  • no HW-Config change necessary
  • no change of PLC-software necessary
  • including Classic OPC-DA-Server-lite (max. 100 variables)
  • with PG-diagnostic-port (occupied slot with PG-port free again)
  • DPV1-master of class 2 and supports all functions that a PG supports:
    • Diagnosis, configuration and programming of controllers (via software such as Simatic-Manager, TIA-Portal)
    • Diagnosis and configuration of DP-slaves (via software such as Starter)
  • active module, no influencing other bus users in the system
  • active PUT/GET (in module integrated) replaces expensive CP´s for PLC-couplings
  • Supply from S7-PLC or 24V DC external
  • CE/EMC compliant design
  • standard functions like S7-LAN connector

Applications:

  • Operational data collection, SCADA of non-networkable controllers
  • KTP-panel to S7-PLC with MPI-/Profibus-interface
  • PUT/GET from S7-1500/1200/300/400 (PN-CPU or with ethernet-CP) with specified and unspecified connection
  • VPN-remote-maintenance, maintenance of the PLC via the Internet
  • cyclic time reading from NTP-server and setting in the connected PLC
  • coupling with DB-transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or also S5-Gateway
  • any TCP-device writes/reads DBs in the S7-300/400 controller
  • monitor variables in the WebServer without a Step7 programming-package
  • analysis option of the connected bus-system with spikes- and errors-counter
Configuration:
  • Easiest configuration through intuitive web server operation!

The S7 bridge is designed for fast commissioning.
After the module has been plugged into the bus, just set a a IP address directly via the web interface or use the TIC-Driver directly installed @Siemens Software.
After that, the controllers can already be accessed from the network.

NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!

  • Plug in the module, activate WIFI on the laptop, connect with Bridge-WIFI -> DONE

STEP-7 / TIA / WIN-CC / MICROWIN:
Thanks to the TIC driver, every additional installation outside the Siemens world is eliminated.
The configuration takes place direkt in the PG-PC interface and is thus optimally integrated.
Each network device that speaks RFC1006 S7-TCP / IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP / IP and expands every MPI bus / PROFIBUS by a network gateway.
It does not matter which controller type, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- Thanks to aktiv PUT / GET , integrated directly in the module, no expensive CP's are required for PLC couplings.
- Supports Banner maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.

Programming / Adapting / Converting
The S7 bridge can be used directly as a WLAN gateway for PLCs. Program and visualize S7 PLC via WLAN is no longer a problem. Thanks to ext. Power supply also usable as Profinet-WIFI adapter.
The S7 SPS Bridge with all functions is the perfect PLC network adapter for every application.

The S7-Bridge is a reliable and handy S7-WIFI network adapter for every PPI, MPI - PROFIBUS and Profinet .
Its compact design in PROFIBUS connector and its power supply directly from the CPU,
enable a PLC to be connected to the Ethernet in less than 5 minutes.
Bus protocols, including baud rate and HSA, are automatically and automatically detected and set.
Programming of S7-PLCs via LAN
Produkbild

S7-PLC with PPI, MPI, Profibus connection, but data should be read/written via network?
Ethernet-CP cannot be used because of the effort (hardware-configuration), price, space in the rack, availability. Plug S7-LAN-module/MPI-LAN-cable into a free bus-connector, assign the IP-address and the PLC can be reached via the network. There is no need to invest any more effort. The adapter can be parameterized via an integrated web-server or a configuration-tool. No changes to the S7-PLC are necessary to operate the adapter.
The adapter can also be used to implement PUT/GET-connections to other controls, but the PLC-program must be changed for this. Other PLCs can just as well read/write data from this controller via PUT/GET; nothing needs to be changed in the PLC program.
Automation very easy: Connect, parameterize and work.

Watching of S7-PLC-devices via LAN without Ethernet-CP
Produkbild
Your panel only has a LAN-socket as PLC-interface? No problem, connect this socket with the S7-LAN or the MPI-LAN-cable and plug it directly on the PPI/MPI/Profibus of the PLC. Then access to the variables and data of the PLC is already available.
S7-CP-replacement (without LAN-CP to the PLC-device)
Produkbild
Do you have a S7-PLC-device without CP243-1, CP343-1 or CP443-1 and would like to connect via LAN? Then plug the S7-LAN on the PLC-device and your access via RFC1006 is ready for use.
Remote maintenance / telecontrol of PLC-devices via LAN / internet
Produkbild
You have access to a on-site network and your PLC-device has no LAN-connection? No problem, plug the S7-LAN on the PLC-device and you will have immediate access to the PLC from afar.
Without LAN-cable round of the PLC
Produkbild

Your’re right in the middle of your production line and and should move around the machine and simultaneously observe / manage. No problem, you parameterize the S7-WLAN-Bridge, connect to the MPI-LAN and connect to an access-point or with the ad-hoc-network of your laptop and are ONLINE on the PLC.

Transformation of Rack/Slot in TSAP to MPI-address
Produkbild
Your panel or visualisationsystem addresses the used PLC with Rack/Slot in TSAP? No problem, activate this mode in the MPI-LAN-cable and you will get actual data from the PLC.
PLC-coupling (data exchange between PLC-devices)
Produkbild
Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Thereto no dedicated line is required, it’s sufficient when the stations connect via network (DSL-router).
Actual time for the PLC?
Produkbild
You need in your PLC a actual time? No problem, with the NTP-function the MPI-LAN-cable get from a NTP-(Time-)Server the actual time and transfers it direct into the configured PLC or for processing in a DB.
Variable-chart without Step7-programming package
Produkbild
You would like to give your customer the opportunity to read current numbers of the manufacturing Online, without installing a visualisation or even the STEP7-package? Then a S7-LAN with the option „Status Variable“ is needed, and your customer can take a look at these password protected data on a site of the integrated webserver.
Malfunctions on the Bus although everything is (apparently) connected properly?
Produkbild
The S7-LAN can also be used for controlling/checking the MPI/Profibus. It will be plugged on the Bus so that you can take a look at the status of the busses via software on PC, for example the numbers of parity errors.
Supply voltage: 24V DC +/- 20%
Power consumption: 2,5 watt
Display: double lined LCD-display
Handling/Configuration: Kabelmanager-Software
keypad on the back
Interfaces:
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
10/100MBit ethernet interface
Galvanic separation: 1500V PPI/MPI/Profibus to the PC
Operating temperature: 0 - 55°C
Case: ABS-plastic case
Dimensions: 146 x 41 x 29 mm
 
Scope of delivery: MPI-LAN-cable
Power connector 2pins small
All prices plus costs of delivery, shipping insurance and VAT.

accessories:

9361-7
T-Connector to PPI / MPI-Bus

doubling of PPI/MPI/Profibus-port without bus connector
Quickbestellung INFOMAIL
by e-mail
166,00 €
plus VAT. and shipping


9391-USB
USB-powercable for 24V DC, max. 3W

USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
Quickbestellung INFOMAIL
by e-mail
95,00 €
plus VAT. and shipping


84,00 €
plus VAT. and shipping


9391-HH
DIN-rail-holder for MPI/PPI

quick and easy assembling on the cap rail
9350-WAND
Wall-mounting

for MPI/PPI + MPI-II + MPI-USB
9352-24
Power connector 2pins small

cable coupling by screw-connector (small)
Quickbestellung INFOMAIL
by e-mail
4,00 €
plus VAT. and shipping


9350-9-CHP-CC
Option CheapConn for MPI

9350-9-CHP+9350-9-CHP-K already mounted
Quickbestellung INFOMAIL
by e-mail
48,00 €
plus VAT. and shipping


9352-104-2
MPI-PC104-card 2 channel up to 12Mbaud Obsolete

equates to PC104-standard (90.2 x 95.9mm)
9352-104
MPI-PC104-card 1 channel up to 12Mbaud Obsolete

equates to PC104-standard (90.2 x 95.9mm)
9391.1
24V DC power-supply unit 625mA

Primary 110V - 240 VAC Euro+USA-plug
Quickbestellung INFOMAIL
by e-mail
59,00 €
plus VAT. and shipping


9350-9-CHP-K
Connecting cable MPIx to CheapConn

9-pins 1 : 1 plated-through with shield
Quickbestellung INFOMAIL
by e-mail
6,00 €
plus VAT. and shipping


9350-9-CHP
CheapConn Busconnector

for MPI/PROFIBUS inclusive variable insert
Quickbestellung INFOMAIL
by e-mail
37,00 €
plus VAT. and shipping


9352-S7-BK
S7-bus-coupler

Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
Quickbestellung INFOMAIL
by e-mail
42,00 €
plus VAT. and shipping


All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.

9352-USB
MPI-USB-cable 3m

PPI/MPI/Profibus up to 12Mbit/s
Quickbestellung INFOMAIL
by e-mail
359,00 €
plus VAT. and shipping


9352-LANCON
S7-LAN connector for Siemens S7 PLC controller

Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
Quickbestellung INFOMAIL
by e-mail
423,00 €
plus VAT. and shipping


214,00 €
plus VAT. and shipping


9359-LAN
S5-LAN++

Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
Quickbestellung INFOMAIL
by e-mail
452,00 €
plus VAT. and shipping


9391.1
24V DC power-supply unit 625mA

Primary 110V - 240 VAC Euro+USA-plug
Quickbestellung INFOMAIL
by e-mail
59,00 €
plus VAT. and shipping


9359-1
PG-USB-cable 3m for Siemens S5 Controller

for PLC's + LED + metal case
Quickbestellung INFOMAIL
by e-mail
145,00 €
plus VAT. and shipping