S7-BRIDGE
Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI
for PLC/CP-IP - connection
Also available as a set for universal use: S5/S7-BRIDGE-WIFI-SetsProduct Overview:
Our S7-BRIDGE is the world's smallest gateway to all your controllers .
Through integrated WIFI and Ethernet interface, in the housing of a Profibus plug, a mobile access to all PLC systems is no problem.
Wireless access to the MPI/DP bus with S7-300/400, PPI with S7-200 or Profinet on all S7-1200/1500 controllers is no longer an obstacle, it offers the possibility of Access to all other network components.
At the same time, the system works as a S7 network adapter for programming, remote maintenance and for coupling the different PLCs.
Thus, both HMI devices, e.g. current panel series , as well as any other S7-Ethernet device, be connected directly via S7-TCP-IP via LAN & WIFI.
! parallel access to MPI/PPI/PROFIBUS !
Quite simply from Siemens TIA, Simatic Step7 Manager, MICROWIN and WinCC projects
more...
variants:
ARTNR: 9359-3
PG-UNI-cable 3m
104,00 € plus VAT. and shipping
ARTNR: 9359-3
PG-UNI-cable 3m
EAN number: | 4260363240307 | |
HS-code: | 85444290 | |
Weight: | 0.2 kg |
S5
device type | ||||||
S5-90U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-95U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-100U |
x
|
+ext. 24V(3)
|
+ext. 24V
|
x
|
x
|
x
|
S5-115U |
at 944 + 9359-8
|
at 944 + 9359-8 + ext. 24V (4)
|
x
|
x
|
x
|
x
|
S5-135U |
at 928B + 9359-8
|
at 928B + 9359-8 +ext. 24V (6)
|
x
|
x
|
x
|
x
|
S5-155U |
x
|
x
|
x
|
x
|
x
|
x
|
S5-AG110S |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG130W/B |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG150A/K/S/U |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
CP-143 |
x
|
x
|
x
|
|||
CP-521 |
+CP521 adapter
|
+CP521 adapter(1)
|
||||
CP-523 |
+CP523 adapter
|
+CP523 adapter(1)
|
||||
CP-525 |
+9359-5(1)
|
|||||
CP-526 |
x
|
x
|
x
|
|||
CP-527 |
x
|
x
|
x
|
|||
CP-528 |
x
|
x
|
x
|
|||
CP-544 |
x (7)
|
x (7)
|
x (7)
|
|||
CP-5430 |
x
|
x
|
x
|
|||
CP-5431 |
x
|
|||||
IP-246 |
x
|
x
|
x
|
|||
IP-247 |
x
|
x
|
x
|
|||
IP-252 |
x
|
x
|
x
|
|||
IP-266 |
x
|
+9359-4(1)
|
||||
WF-470 |
+9359-5-WF470 + 9359-4(1)
|
|||||
SIN-805 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-820 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-840 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-850 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-880 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
Connection on PC |
RS232-port
|
Ethernet RJ45
|
Ethernet RJ45 / WLAN/WIFI
|
USB-port type A
|
RS232-port
|
RS232-port
|
max. prolongation: | 300m (UNI-extension) | 300m (S5-LAN-extension) +ext. 24V | 100m (PG-USB-extension) | 300m (UNI-extension) | ||
(1) ISO adapter can not be used because the required supply voltage on the PG interface of the module is not present. (2) At the CPU 6ES5 102-8MA02 Release 3 is a PG-ISO-Adapter or Netz-Adapter additional required. (3) With S5-LAN++ from HW V2.3 [2010] the "Netz-Adapter" is no more needed, this version has included current-sources. (4) With S5-LAN++ from HW V2.3 [2010] no accessories are needed, this version has included current-sources. (5) With S5-LAN++ from HW V2.3 [2010] the Sinum-Adapter 9359-6-USB is needed. (6) Only for CPU928B with PG-ISO-Adapter and ext. 24V DC, unless there is an S5-LAN++ from HW V2.3 [2010] used. (7) CP544 has bolts at the programming-interface. The products do not fit 100% on this interface. (8) With S5-BRIDGE the Sinum-Adapter 9359-6-USB is needed. |
Also available as a set for universal use: S5/S7-BRIDGE-WIFI-Sets
Product Overview:
Our S7-BRIDGE is the world's smallest gateway to all your controllers .
Through integrated WIFI and Ethernet interface, in the housing of a Profibus plug, a mobile access to all PLC systems is no problem.
Wireless access to the MPI/DP bus with S7-300/400, PPI with S7-200 or Profinet on all S7-1200/1500 controllers is no longer an obstacle, it offers the possibility of Access to all other network components.
At the same time, the system works as a S7 network adapter for programming, remote maintenance and for coupling the different PLCs.
Thus, both HMI devices, e.g. current panel series , as well as any other S7-Ethernet device, be connected directly via S7-TCP-IP via LAN & WIFI.
! parallel access to MPI/PPI/PROFIBUS !
Quite simply from Siemens TIA, Simatic Step7 Manager, MICROWIN and WinCC projects
Thanks to the integrated TIC driver without project changes.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-Firmware-Datei
TIC-(Totally Integrated Communication)-driver for Step7/TIA-Portal for Win XP/VISTA/7/8/10/11 32/64 bit:
TIC firmware / configuration tool / Step7-/TIA-driver
Features:
The S7 bridge is designed for fast commissioning.
After the module has been plugged into the bus, just set a a IP address directly via the web interface or use the TIC-Driver directly installed @Siemens Software.
After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
STEP-7 / TIA / WIN-CC / MICROWIN:
Thanks to the TIC driver, every additional installation outside the Siemens world is eliminated.
The configuration takes place direkt in the PG-PC interface and is thus optimally integrated.
Each network device that speaks RFC1006 S7-TCP / IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP / IP and expands every MPI bus / PROFIBUS by a network gateway.
It does not matter which controller type, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- Thanks to aktiv PUT / GET , integrated directly in the module, no expensive CP's are required for PLC couplings.
- Supports Banner maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S7 bridge can be used directly as a WLAN gateway for PLCs. Program and visualize S7 PLC via WLAN is no longer a problem. Thanks to ext. Power supply also usable as Profinet-WIFI adapter.
The S7 SPS Bridge with all functions is the perfect PLC network adapter for every application.
The S7-Bridge is a reliable and handy S7-WIFI network adapter for every PPI, MPI - PROFIBUS and Profinet .
Its compact design in PROFIBUS connector and its power supply directly from the CPU,
enable a PLC to be connected to the Ethernet in less than 5 minutes.
Bus protocols, including baud rate and HSA, are automatically and automatically detected and set.
Product Overview:
Our S7-BRIDGE is the world's smallest gateway to all your controllers .
Through integrated WIFI and Ethernet interface, in the housing of a Profibus plug, a mobile access to all PLC systems is no problem.
Wireless access to the MPI/DP bus with S7-300/400, PPI with S7-200 or Profinet on all S7-1200/1500 controllers is no longer an obstacle, it offers the possibility of Access to all other network components.
At the same time, the system works as a S7 network adapter for programming, remote maintenance and for coupling the different PLCs.
Thus, both HMI devices, e.g. current panel series , as well as any other S7-Ethernet device, be connected directly via S7-TCP-IP via LAN & WIFI.
! parallel access to MPI/PPI/PROFIBUS !
Quite simply from Siemens TIA, Simatic Step7 Manager, MICROWIN and WinCC projects
Thanks to the integrated TIC driver without project changes.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-Firmware-Datei
TIC-(Totally Integrated Communication)-driver for Step7/TIA-Portal for Win XP/VISTA/7/8/10/11 32/64 bit:
TIC firmware / configuration tool / Step7-/TIA-driver
Features:
- every SIMATIC-S7 (S7-200/300/400) into Network
- Replacement for CP343-1/443-1, connected directly to MPI or Profibus
- with Profibus for S7-300 faster than CP343-1
- fastest installation into Network (less than 3 minutes)
- automatic detection of baudrate
- automatic usement of cyclic bus-parameter-protocols
- no bus-knowledge required / automatic-protocol and baud-rate detection
- download TIC-driver for STEP-7/TIA-Portal
- Programming and visualization at the same time (8 connections at the same time)
- compatible to S7-TCP/IP RFC1006, WinCC (flex), OPC UA with Universal communication Industry 4.0, the IP-S7LINK SDK as well as all common OPC-servers
- no HW-Config change necessary
- no change of PLC-software necessary
- including Classic OPC-DA-Server-lite (max. 100 variables)
- with PG-diagnostic-port (occupied slot with PG-port free again)
- DPV1-master of class 2 and supports all functions that a PG supports:
- Diagnosis, configuration and programming of controllers (via software such as Simatic-Manager, TIA-Portal)
- Diagnosis and configuration of DP-slaves (via software such as Starter)
- active module, no influencing other bus users in the system
- active PUT/GET (in module integrated) replaces expensive CP´s for PLC-couplings
- Supply from S7-PLC or 24V DC external
- CE/EMC compliant design
- standard functions like S7-LAN connector
Applications:
- Operational data collection, SCADA of non-networkable controllers
- KTP-panel to S7-PLC with MPI-/Profibus-interface
- PUT/GET from S7-1500/1200/300/400 (PN-CPU or with ethernet-CP) with specified and unspecified connection
- VPN-remote-maintenance, maintenance of the PLC via the Internet
- cyclic time reading from NTP-server and setting in the connected PLC
- coupling with DB-transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or also S5-Gateway
- any TCP-device writes/reads DBs in the S7-300/400 controller
- monitor variables in the WebServer without a Step7 programming-package
- analysis option of the connected bus-system with spikes- and errors-counter
- Easiest configuration through intuitive web server operation!
The S7 bridge is designed for fast commissioning.
After the module has been plugged into the bus, just set a a IP address directly via the web interface or use the TIC-Driver directly installed @Siemens Software.
After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
- Plug in the module, activate WIFI on the laptop, connect with Bridge-WIFI -> DONE
STEP-7 / TIA / WIN-CC / MICROWIN:
Thanks to the TIC driver, every additional installation outside the Siemens world is eliminated.
The configuration takes place direkt in the PG-PC interface and is thus optimally integrated.
Each network device that speaks RFC1006 S7-TCP / IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP / IP and expands every MPI bus / PROFIBUS by a network gateway.
It does not matter which controller type, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- Thanks to aktiv PUT / GET , integrated directly in the module, no expensive CP's are required for PLC couplings.
- Supports Banner maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S7 bridge can be used directly as a WLAN gateway for PLCs. Program and visualize S7 PLC via WLAN is no longer a problem. Thanks to ext. Power supply also usable as Profinet-WIFI adapter.
The S7 SPS Bridge with all functions is the perfect PLC network adapter for every application.
The S7-Bridge is a reliable and handy S7-WIFI network adapter for every PPI, MPI - PROFIBUS and Profinet .
Its compact design in PROFIBUS connector and its power supply directly from the CPU,
enable a PLC to be connected to the Ethernet in less than 5 minutes.
Bus protocols, including baud rate and HSA, are automatically and automatically detected and set.
Serial communication to the S5-PLC
Universally to the S5-PLC, free 9-pin COM-port is sufficient on the PC and free PG-port on the PLC.
No external supply necessary as long as PLC offers current-sources on the PG-interface. Distance to PLC up to a maximum of 300m over 4-wire connection. Each S5-PLC can be connected, also 25-pin AS511 plug-in-card (S5-150U) via net-adapter and AG-150-adapter.
No external supply necessary as long as PLC offers current-sources on the PG-interface. Distance to PLC up to a maximum of 300m over 4-wire connection. Each S5-PLC can be connected, also 25-pin AS511 plug-in-card (S5-150U) via net-adapter and AG-150-adapter.
Serial communication with CP and more S5-assemblies
You have a PC with programming software and a 9pin COM-port as interface? No problem, for this purpose the PG-UNI-cable is exactly the right product. Connect it to a Siemens assembly such as H1-CP
(CP1430), WF470 and PC or CP-525 with the CP525-adapter and PC and you’re Online.
Supply voltage: | from the current sources of the PLC |
Power consumption: | 0,2 watt |
Display: | - |
Interfaces: |
to the PLC:
TTY/20mA current loop (PG-COM passiv, PLC aktiv)
to the PD/PC:
RS232: 9,6 KBd - 115,2 KBd |
Operating temperature: | 0 - 55°C |
Case: | plastic case |
Dimensions: | 47 x 40 x 15 mm |
Scope of delivery: | PG-UNI-cable |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
69,00 €
plus VAT. and shipping
plus VAT. and shipping
21,00 €
plus VAT. and shipping
plus VAT. and shipping
21,00 €
plus VAT. and shipping
plus VAT. and shipping
12,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
104,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-5-150
AG-150-adapter
for PG-UNI + PG-UNI-II-cable + S5-LAN++ (up to HW2.2) with Netz-Adapter to AG-150
AG-150-adapter
for PG-UNI + PG-UNI-II-cable + S5-LAN++ (up to HW2.2) with Netz-Adapter to AG-150
46,00 €
plus VAT. and shipping
plus VAT. and shipping
32,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
9310
Additional charge 25-pins PC-plug
Special construction of the RS232-side with 25pin D-Sub female with screwing locks
Additional charge 25-pins PC-plug
Special construction of the RS232-side with 25pin D-Sub female with screwing locks
39,00 €
plus VAT. and shipping
plus VAT. and shipping
9310-M
Additional charge 25-pins PC-plug in metallized case
Special construction of the RS232-side with 25pin D-Sub female with screwing locks in metallized case
Additional charge 25-pins PC-plug in metallized case
Special construction of the RS232-side with 25pin D-Sub female with screwing locks in metallized case
77,00 €
plus VAT. and shipping
plus VAT. and shipping
118,00 €
plus VAT. and shipping
plus VAT. and shipping
143,00 €
plus VAT. and shipping
plus VAT. and shipping
3,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
104,00 €
plus VAT. and shipping
plus VAT. and shipping
115,00 €
plus VAT. and shipping
plus VAT. and shipping
133,00 €
plus VAT. and shipping
plus VAT. and shipping
104,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-90
CP-cable
connects PD-TTY-port of TP-I, TP-II with L1,H1,L2-CP, D-Sub 15pin (male) <=> D-Sub 15pin (male)
CP-cable
connects PD-TTY-port of TP-I, TP-II with L1,H1,L2-CP, D-Sub 15pin (male) <=> D-Sub 15pin (male)
57,00 €
plus VAT. and shipping
plus VAT. and shipping
S5 over RS232
PG-COM
Couples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
Couples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
PG-UNI II
Couples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
Couples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
PG-ISO-set
PLC-communication with 1000V galvanic separation without power supply
PLC-communication with 1000V galvanic separation without power supply
S5toMPI
Connects the S5-PLC with a S7-PLC
Connects the S5-PLC with a S7-PLC
All prices plus costs of delivery, shipping insurance and VAT.
3,00 €
plus VAT. and shipping
plus VAT. and shipping
118,00 €
plus VAT. and shipping
plus VAT. and shipping
104,00 €
plus VAT. and shipping
plus VAT. and shipping
32,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
69,00 €
plus VAT. and shipping
plus VAT. and shipping