TINA - mobile intelligent network-analyser
Simple Network-troubleshooting +++ Webserver operation/control +++ Networkanalysis 10/100 MBit without effort +++ To PC with 2,4 GHz +++ Detection network violations +++ Resolve IP-address conflicts +++ PROFINET monitori
DB-exchange from S5 to S7
over the PD-ports
- Non-reactive recording of Ethernet communication
- Secure and passive decoupling of telegrams
- Monitors all OSI layers starting from layer 2 and packets of all sizes and types and VLAN traffic
more...
559,00 € plus VAT. and shipping
ARTNR: 9352-S5-OP
S5toMPI/Profibus
EAN number: | 4260363243322 | |
HS-code: | 85444290 | |
Weight: | 0.3 kg |
S5
device type | ||||||
S5-90U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-95U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-100U |
x
|
+ext. 24V(3)
|
+ext. 24V
|
x
|
x
|
x
|
S5-115U |
at 944 + 9359-8
|
at 944 + 9359-8 + ext. 24V (4)
|
x
|
x
|
x
|
x
|
S5-135U |
at 928B + 9359-8
|
at 928B + 9359-8 +ext. 24V (6)
|
x
|
x
|
x
|
x
|
S5-155U |
x
|
x
|
x
|
x
|
x
|
x
|
S5-AG110S |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG130W/B |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG150A/K/S/U |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
CP-143 |
x
|
x
|
x
|
|||
CP-521 |
+CP521 adapter
|
+CP521 adapter(1)
|
||||
CP-523 |
+CP523 adapter
|
+CP523 adapter(1)
|
||||
CP-525 |
+9359-5(1)
|
|||||
CP-526 |
x
|
x
|
x
|
|||
CP-527 |
x
|
x
|
x
|
|||
CP-528 |
x
|
x
|
x
|
|||
CP-544 |
x (7)
|
x (7)
|
x (7)
|
|||
CP-5430 |
x
|
x
|
x
|
|||
CP-5431 |
x
|
|||||
IP-246 |
x
|
x
|
x
|
|||
IP-247 |
x
|
x
|
x
|
|||
IP-252 |
x
|
x
|
x
|
|||
IP-266 |
x
|
+9359-4(1)
|
||||
WF-470 |
+9359-5-WF470 + 9359-4(1)
|
|||||
SIN-805 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-820 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-840 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-850 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-880 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
Connection on PC |
RS232-port
|
Ethernet RJ45
|
Ethernet RJ45 / WLAN/WIFI
|
USB-port type A
|
RS232-port
|
RS232-port
|
max. prolongation: | 300m (UNI-extension) | 300m (S5-LAN-extension) +ext. 24V | 100m (PG-USB-extension) | 300m (UNI-extension) | ||
(1) ISO adapter can not be used because the required supply voltage on the PG interface of the module is not present. (2) At the CPU 6ES5 102-8MA02 Release 3 is a PG-ISO-Adapter or Netz-Adapter additional required. (3) With S5-LAN++ from HW V2.3 [2010] the "Netz-Adapter" is no more needed, this version has included current-sources. (4) With S5-LAN++ from HW V2.3 [2010] no accessories are needed, this version has included current-sources. (5) With S5-LAN++ from HW V2.3 [2010] the Sinum-Adapter 9359-6-USB is needed. (6) Only for CPU928B with PG-ISO-Adapter and ext. 24V DC, unless there is an S5-LAN++ from HW V2.3 [2010] used. (7) CP544 has bolts at the programming-interface. The products do not fit 100% on this interface. (8) With S5-BRIDGE the Sinum-Adapter 9359-6-USB is needed. |
S7
PPI-Bus | |||||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||||
USB | |||||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||||
LAN | |||||||||
10/100BaseTx |
x(7)
|
x
|
x
|
x
|
x
|
||||
WIFI | |||||||||
2.4 GHz |
x
|
||||||||
TeleService operation | |||||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||||
baud rates at TS-operation directly at the PC | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||||
baud rates at TS-operation directly with a modem | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x
|
x
|
|||||||
115.2 KBit/s |
x
|
x
|
|||||||
HMI | |||||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||||
PLCVCOM |
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
RFC1006 |
8
|
8
|
32
|
32
|
32
|
||||
AG connections (maximum) | |||||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||||
integrated PLC-firewall |
|
|
x
|
x
|
x
|
||||
display diagnostic-buffer in the webbrowser |
|
|
x
|
x
|
x
|
||||
webserver for configuration |
x
|
x
|
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
x
|
x
|
||||
galvanic separation | |||||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
1,5KV
|
1,5KV
|
mounting | |||||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||||
upgrading with | |||||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||||
supports | |||||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win11 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1 (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3 (3) only serial communication (4) Siemens Step7 V5.2 and higher dont run with this operationing system (5) USB-communication is only possible with the special driver for Win NT (6) USB 2.0 is backward compatible to 1.1 (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation (8) only in combination with the MPI-Speed-driver („continously-active“) (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional) (11) only in the mode: MultiMaster-Mode (12) up to a maximum baud rate of 187.5 KBit/s (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port. (14) with the use of the TS-adapter / item number: 9350.TS (15) Update directly with PC and TIC-driver (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens (19) only at PPI-communication possible (20) Only with TIC-driver (21) with integrated webserver possible (22) No support of Siemens Step7-software possible (23) Only with USB and with TIC-driver |
Features:
Product Overview:
TINA is a handy device for analyzing network problems and network conflicts .
The device is plugged directly into the network cable without any further switches or peripherals.
With user rights and password protection, access via both LAN and WLAN is possible and well secured.
No PC with installed software is required for operation, the complete configuration and recording process takes place in the integrated web server.
Surveillance violations are reported directly by e-mail, special rules therefore can be specifically assigned.
Thanks to TINA, it´s now possible to find network problems and analyze network errors in a few minutes coupled with immediately bug fixing.
The network analysis includes functions such as IP conflicts, SUB-NET errors, runtime errors, missing subscribers due to subscriber failure and much more.
Application areas:
Configuration:
A configuration interface created for common systems eliminates the need for a long time in the system.
Most settings in the network area are quick and easy to set even for inexperienced users.
Thanks to free creatable rules and monitoring modes no unauthorized access and no unauthorized device escapes the attention.
The entire control and release monitoring must also be set directly in the web server like the rest of the configuration.
Recording and analysis directly in the web server, also for mobile devices:
Network analyzes and recordings can be started and operated directly in the web server.
Network packets are recorded and displayed in detail and divided into categories.
All settings are optimized for fast and easy operation.
Control surfaces extra large and simple, so the network analysis can also be performed with smartphones .
- Non-reactive recording of Ethernet communication
- Secure and passive decoupling of telegrams
- Monitors all OSI layers starting from layer 2 and packets of all sizes and types and VLAN traffic
- For 10 or 100Mbit/s
- To monitoring-PC with WIFI 2,4 GHz
- Complete operation (display and parameterization) via web server via WLAN.
- No extra recording devices and no cumbersome analysis software must be installed.
- Perfect for mobile devices.
- Immediate e-mail alerting for surveillance violations.
- Thanks to immediate alerting, with freely adjustable violations, not network error will be missed again.
- By using the timestamp exact identifying the point of the network error in the analysis will be no problem any more .
- Display of subscriber connections (which subscriber accesses which subscriber).
- M2M connections are now transparent! TINA shows exactly who communicates with whom at the IP level . Missing or incorrect network connections can be determined directly.
- Inconsistencies in accessing certain subnets ? We will show each connection directly with source and destination address incl. all data.
- Simple Exchange of IP addresses in order to be able to communicate with the device in another subnet (eg S7-LAN).
- For IP address conflicts TINA can intervene directly and change the "wrong" IP address directly.
- Regardless of whether devices are hanging in direct access or are removed, thanks to network protocol transmission , values ??for the corresponding device can be changed directly in the TINA web server.
- Read and write Wireshark files
- For later post-processing or for sharing with others, the recording format is 100% Wireshark compatible . This allows a later evaluation on each PC, detached from the recording hardware.
- Wireshark records can also be imported into the TINA interface for comparison or verification.
- Network tools like Ping, Traceroute, ... integrated
- Full function of all popular "fast" analysis functions as you know from the PC.
Product Overview:
TINA is a handy device for analyzing network problems and network conflicts .
The device is plugged directly into the network cable without any further switches or peripherals.
With user rights and password protection, access via both LAN and WLAN is possible and well secured.
No PC with installed software is required for operation, the complete configuration and recording process takes place in the integrated web server.
Surveillance violations are reported directly by e-mail, special rules therefore can be specifically assigned.
Thanks to TINA, it´s now possible to find network problems and analyze network errors in a few minutes coupled with immediately bug fixing.
The network analysis includes functions such as IP conflicts, SUB-NET errors, runtime errors, missing subscribers due to subscriber failure and much more.
Application areas:
- Exposure of burglary and unauthorized access to your company network.
- Help with commissioning, third-party machines can be analyzed and adjusted.
- Analysis of VoIP protocols and audio voice output in case of problems with your telephone system
- Detecting Address Conflicts
- Find and analyze network problems and fix them directly.
- Check LAN connections for your failure risk ( Re-transmission ...)
- Search, scan and exchange IP addresses and record their communication.
- monitoring of complete network segments.
Configuration:
A configuration interface created for common systems eliminates the need for a long time in the system.
Most settings in the network area are quick and easy to set even for inexperienced users.
Thanks to free creatable rules and monitoring modes no unauthorized access and no unauthorized device escapes the attention.
The entire control and release monitoring must also be set directly in the web server like the rest of the configuration.
Recording and analysis directly in the web server, also for mobile devices:
Network analyzes and recordings can be started and operated directly in the web server.
Network packets are recorded and displayed in detail and divided into categories.
All settings are optimized for fast and easy operation.
Control surfaces extra large and simple, so the network analysis can also be performed with smartphones .
Coupling of S5-PLC with S7-PLC via PD-interfaces
S5 in the machine-park, conversion to S7 not profitable, central-control still requires production-data, who does not know this problem.
With "S5anMPI" you connect the S5-PLC with a standard interface-cable with the MPI/PROFIBUS of a S7-PLC. Loading handling-blocks in both PLCs, communication integrated and "S5anMPI" exchanges DB-content on request of the respective PLC. Configuration in the "S5anMPI" which PLC is active, also both PLCs active is possible.
Data-exchange without much effort and the S5-PLC continues in the S7-combination as usual and does not have to be replaced.
With "S5anMPI" you connect the S5-PLC with a standard interface-cable with the MPI/PROFIBUS of a S7-PLC. Loading handling-blocks in both PLCs, communication integrated and "S5anMPI" exchanges DB-content on request of the respective PLC. Configuration in the "S5anMPI" which PLC is active, also both PLCs active is possible.
Data-exchange without much effort and the S5-PLC continues in the S7-combination as usual and does not have to be replaced.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2,5 watt |
Display: | double lined LCD-display |
Handling/Configuration: |
Kabelmanager-Software keypad on the back |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
RS232: 9,6 KBd - 115,2 KBdUSB 1.1 for cable type A <-> A |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 146 x 41 x 29 mm |
Scope of delivery: |
S5anMPI-cable Power connector 2pins small |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
9350-WAND
Wall-mounting
for MPI/PPI + MPI-II + MPI-USB
Wall-mounting
for MPI/PPI + MPI-II + MPI-USB
9391-HH
DIN-rail-holder for MPI/PPI
quick and easy assembling on the cap rail
DIN-rail-holder for MPI/PPI
quick and easy assembling on the cap rail
37,00 €
plus VAT. and shipping
plus VAT. and shipping
6,00 €
plus VAT. and shipping
plus VAT. and shipping
59,00 €
plus VAT. and shipping
plus VAT. and shipping
48,00 €
plus VAT. and shipping
plus VAT. and shipping
4,00 €
plus VAT. and shipping
plus VAT. and shipping
appropriate interface-cables:
69,00 €
plus VAT. and shipping
plus VAT. and shipping
69,00 €
plus VAT. and shipping
plus VAT. and shipping
113,00 €
plus VAT. and shipping
plus VAT. and shipping
133,00 €
plus VAT. and shipping
plus VAT. and shipping
115,00 €
plus VAT. and shipping
plus VAT. and shipping
145,00 €
plus VAT. and shipping
plus VAT. and shipping
127,00 €
plus VAT. and shipping
plus VAT. and shipping
96,00 €
plus VAT. and shipping
plus VAT. and shipping
77,00 €
plus VAT. and shipping
plus VAT. and shipping
104,00 €
plus VAT. and shipping
plus VAT. and shipping
115,00 €
plus VAT. and shipping
plus VAT. and shipping
104,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
RS232
MPI-II
Universal S7interface-cable +++ RS232/USB to PPI/MPI/PROFIBUS +++ For HMI-USB applications +++ Bus-status on display
Universal S7interface-cable +++ RS232/USB to PPI/MPI/PROFIBUS +++ For HMI-USB applications +++ Bus-status on display
S5 over RS232
PG-COM
Couples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
Couples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
PG-UNI
Couples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
Couples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
PG-UNI II
Couples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
Couples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
PG-ISO-set
PLC-communication with 1000V galvanic separation without power supply
PLC-communication with 1000V galvanic separation without power supply
MPI/PPI
S7-Interface cable for PPI, MPI, TS, HMI <=> RS232 applications
S7-Interface cable for PPI, MPI, TS, HMI <=> RS232 applications
All prices plus costs of delivery, shipping insurance and VAT.
359,00 €
plus VAT. and shipping
plus VAT. and shipping
32,00 €
plus VAT. and shipping
plus VAT. and shipping
69,00 €
plus VAT. and shipping
plus VAT. and shipping
9350-9-DIAG
DiagConn 90° Highend-connector
for PROFIBUS with diagnosis function country of origin: Germany not preferential
DiagConn 90° Highend-connector
for PROFIBUS with diagnosis function country of origin: Germany not preferential
54,00 €
plus VAT. and shipping
plus VAT. and shipping
69,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
452,00 €
plus VAT. and shipping
plus VAT. and shipping