TINA - mobile intelligent network-analyser - Process Informatik Entwicklungsgesellschaft mbH

TINA - mobile intelligent network-analyser


Simple Network-troubleshooting +++ Webserver operation/control +++ Networkanalysis 10/100 MBit without effort +++ To PC with 2,4 GHz +++ Detection network violations +++ Resolve IP-address conflicts +++ PROFINET monitori

for PLC's + LED + metal case

Features:
  • Non-reactive recording of Ethernet communication

  • Secure and passive decoupling of telegrams

  • Monitors all OSI layers starting from layer 2 and packets of all sizes and types and VLAN traffic


    more...
    variants:

    145,00 € plus VAT. and shipping

    ARTNR: 9359-1
    PG-USB-cable 3m for Siemens S5 Controller
    EAN number: 4260363240581
    HS-code: 85444290
    Weight: 0.15 kg



    S5

    device type
    S5-90U
    x
    +ext. 24V
    +ext. 24V
    x
    x
    x
    S5-95U
    x
    +ext. 24V
    +ext. 24V
    x
    x
    x
    S5-100U
    x
    +ext. 24V(3)
    +ext. 24V
    x
    x
    x
    S5-115U
    at 944 + 9359-8
    at 944 + 9359-8 + ext. 24V (4)
    x
    x
    x
    x
    S5-135U
    at 928B + 9359-8
    at 928B + 9359-8 +ext. 24V (6)
    x
    x
    x
    x
    S5-155U
    x
    x
    x
    x
    x
    x
    S5-AG110S
    +9359-5-150 + 9359-4
    + ext. 24V (3)
    +9359-5-150 + ext. 24V
    S5-AG130W/B
    +9359-5-150 + 9359-4
    + ext. 24V (3)
    +9359-5-150 + ext. 24V
    S5-AG150A/K/S/U
    +9359-5-150 + 9359-4
    + ext. 24V (3)
    +9359-5-150 + ext. 24V
    CP-143
    x
    x
    x
    CP-521
    +CP521 adapter
           
    +CP521 adapter(1)
    CP-523
    +CP523 adapter
           
    +CP523 adapter(1)
    CP-525      
    +9359-5(1)
    CP-526
    x
       
    x
     
    x
    CP-527
    x
       
    x
     
    x
    CP-528
    x
       
    x
     
    x
    CP-544
    x (7)
       
    x (7)
     
    x (7)
    CP-5430
    x
       
    x
     
    x
    CP-5431
    x
       
     
    IP-246
    x
       
    x
     
    x
    IP-247
    x
       
    x
     
    x
    IP-252
    x
       
    x
     
    x
    IP-266
     
    x
    +9359-4(1)
    WF-470
    SIN-805
    +9359-6 + ext. 24V(5)
    +9359-6 + ext. 24V(8)
    +9359-6(1)
    SIN-820
    +9359-6 + ext. 24V(5)
    +9359-6 + ext. 24V(8)
    +9359-6(1)
    SIN-840
    +9359-6 + ext. 24V(5)
    +9359-6 + ext. 24V(8)
    +9359-6(1)
    SIN-850
    +9359-6 + ext. 24V(5)
    +9359-6 + ext. 24V(8)
    +9359-6(1)
    SIN-880
    +9359-6 + ext. 24V(5)
    +9359-6 + ext. 24V(8)
     
    +9359-6(1)
    Connection on PC
    RS232-port
    Ethernet RJ45
    Ethernet RJ45 / WLAN/WIFI
    USB-port type A
    RS232-port
    RS232-port
    max. prolongation: 300m (UNI-extension) 300m (S5-LAN-extension) +ext. 24V 100m (PG-USB-extension)   300m (UNI-extension)

    (1) ISO adapter can not be used because the required supply voltage on the PG interface of the module is not present.
    (2) At the CPU 6ES5 102-8MA02 Release 3 is a PG-ISO-Adapter or Netz-Adapter additional required.
    (3) With S5-LAN++ from HW V2.3 [2010] the "Netz-Adapter" is no more needed, this version has included current-sources.
    (4) With S5-LAN++ from HW V2.3 [2010] no accessories are needed, this version has included current-sources.
    (5) With S5-LAN++ from HW V2.3 [2010] the Sinum-Adapter 9359-6-USB is needed.
    (6) Only for CPU928B with PG-ISO-Adapter and ext. 24V DC, unless there is an S5-LAN++ from HW V2.3 [2010] used.
    (7) CP544 has bolts at the programming-interface. The products do not fit 100% on this interface.
    (8) With S5-BRIDGE the Sinum-Adapter 9359-6-USB is needed.

    Stephan Kern Elektrotechniker / Elektromeister
    Schleching

    Zeller Presscontrol Systems und Automatisierungstechnik e.K.
    Wiesensteig
    www.zeller-presscontrol.com

    MSR-SERVICE GmbH
    Mansfeld
    www.msr-online.de

    proCtec GmbH
    Viernheim
    www.proctec.de

    Ing.-Büro Gerdes
    Ulm
    www.ib-gerdes.de

    Elektro-Installatiebedrijf Van Lanen BV
    Mill, Netherlands , Netherlands
    www.etbvanlanen.nl

    Wöhrle Belgium B.V.B.A.
    Mechelen , Belgium
    www.wohrle.be

    Ing. Roland Grabner - Technisches Büro
    Salzburg , Austria
    https://www.grabner-automation.at/

    Burkhalter Automation AG
    Pratteln , Switzerland
    www.buat.ch

    EMIS Automatisierung GmbH
    Mössingen
    www.emis-gmbh.de

    Hediger Elektro AG
    Menziken , Switzerland
    www.hedag.ch

    Innovacion Integral de
    Queretaro, QRO , Mexico
    www.innovaautomation.com.mx
    Features:
    • Non-reactive recording of Ethernet communication

    • Secure and passive decoupling of telegrams

    • Monitors all OSI layers starting from layer 2 and packets of all sizes and types and VLAN traffic

    • For 10 or 100Mbit/s

    • To monitoring-PC with WIFI 2,4 GHz

    • Complete operation (display and parameterization) via web server via WLAN.
      • No extra recording devices and no cumbersome analysis software must be installed.
      • Perfect for mobile devices.

    • Immediate e-mail alerting for surveillance violations.
      • Thanks to immediate alerting, with freely adjustable violations, not network error will be missed again.
      • By using the timestamp exact identifying the point of the network error in the analysis will be no problem any more .

    • Display of subscriber connections (which subscriber accesses which subscriber).
      • M2M connections are now transparent! TINA shows exactly who communicates with whom at the IP level . Missing or incorrect network connections can be determined directly.
      • Inconsistencies in accessing certain subnets ? We will show each connection directly with source and destination address incl. all data.

    • Simple Exchange of IP addresses in order to be able to communicate with the device in another subnet (eg S7-LAN).
      • For IP address conflicts TINA can intervene directly and change the "wrong" IP address directly.
      • Regardless of whether devices are hanging in direct access or are removed, thanks to network protocol transmission , values ??for the corresponding device can be changed directly in the TINA web server.

    • Read and write Wireshark files
      • For later post-processing or for sharing with others, the recording format is 100% Wireshark compatible . This allows a later evaluation on each PC, detached from the recording hardware.
      • Wireshark records can also be imported into the TINA interface for comparison or verification.

    • Network tools like Ping, Traceroute, ... integrated
      • Full function of all popular "fast" analysis functions as you know from the PC.

    Product Overview:
    TINA is a handy device for analyzing network problems and network conflicts .
    The device is plugged directly into the network cable without any further switches or peripherals.
    With user rights and password protection, access via both LAN and WLAN is possible and well secured.
    No PC with installed software is required for operation, the complete configuration and recording process takes place in the integrated web server.
    Surveillance violations are reported directly by e-mail, special rules therefore can be specifically assigned.

    Thanks to TINA, it´s now possible to find network problems and analyze network errors in a few minutes coupled with immediately bug fixing.
    The network analysis includes functions such as IP conflicts, SUB-NET errors, runtime errors, missing subscribers due to subscriber failure and much more.



    Application areas:
    • Exposure of burglary and unauthorized access to your company network.
    • Help with commissioning, third-party machines can be analyzed and adjusted.
    • Analysis of VoIP protocols and audio voice output in case of problems with your telephone system
    • Detecting Address Conflicts
    • Find and analyze network problems and fix them directly.
    • Check LAN connections for your failure risk ( Re-transmission ...)
    • Search, scan and exchange IP addresses and record their communication.
    • monitoring of complete network segments.


    Configuration:
    A configuration interface created for common systems eliminates the need for a long time in the system.
    Most settings in the network area are quick and easy to set even for inexperienced users.




    Thanks to free creatable rules and monitoring modes no unauthorized access and no unauthorized device escapes the attention.
    The entire control and release monitoring must also be set directly in the web server like the rest of the configuration.



    Recording and analysis directly in the web server, also for mobile devices:
    Network analyzes and recordings can be started and operated directly in the web server.



    Network packets are recorded and displayed in detail and divided into categories.



    All settings are optimized for fast and easy operation.
    Control surfaces extra large and simple, so the network analysis can also be performed with smartphones .
    Active on every S5-PLC
    Produkbild
    PLC's without current-sources (+20mA) and voltages (5V/24V) at the PG-interface such as the AS511-plug-in card?
    The PG-USB-cable does not need anything, it is supplied directly from the USB-socket to which it was plugged. It is active towards its communication-partners, contains its own current-sources.
    Universally connected to the S5-PLC without worrying about the supply. Function also given on controls with current-sources/voltages.
    Communication with Win98 – XP/Vista/7/8/10/11 via USB to S5-PLC
    Produkbild
    You still have a PC with Win98 and Step5-package and would like to go Online on your S5-PLC via USB? No problem, the provided virtual Com-Port PLCVCom emulates a COM-port on your PC with which you go Online. With a patchtool for the Siemens Step5-software, which is provided as well, nothing else stands in your way to communicate via LAN.
    Supply voltage: 5V DC
    Power consumption: 0,3 watt
    Display: 2 status-LEDs for RXT/TXD
    Interfaces:
    to the PLC:
    TTY/20mA current loop (PG-USB aktiv, PLC passiv)
    to the PD/PC:
    USB 1.1 cable type A
    Operating temperature: 0 - 55°C
    Case: metal case
    Dimensions: 50 x 40 x 17 mm
     
    Scope of delivery: PG-USB-cable
    All prices plus costs of delivery, shipping insurance and VAT.

    options:

    9390
    Additional charge for special length
    for S5-Interface cables per Meter 3,- Euro
    Quickbestellung INFOMAIL
    by e-mail
    3,00 €
    plus VAT. and shipping


    9359-1.X
    Special length: PG-UNI-cable (3m) + 9390
    for PLC/CP/IP - connection
    Quickbestellung INFOMAIL
    by e-mail
    160,00 €
    plus VAT. and shipping


    accessories:

    9359-6-USB
    PG-USB SINUM-adapter

    for PG-USB-cable + S5-LAN++ (from HW2.3) to SINUMERIK
    Quickbestellung INFOMAIL
    by e-mail
    46,00 €
    plus VAT. and shipping


    9359-5-USB
    PG-USB CP-525-adapter

    for PG-USB-cable <-> CP-525-communication
    Quickbestellung INFOMAIL
    by e-mail
    46,00 €
    plus VAT. and shipping


    9359-5-WF470-USB
    PG-USB WF-470-adapter

    for PG-USB-cable <-> WF470
    Quickbestellung INFOMAIL
    by e-mail
    46,00 €
    plus VAT. and shipping


    9359-5K-USB
    CP-525-K-adapter for PG-USB + S5-LAN++

    PG-USB-cable and S5-LAN++ (at east HW V2.3) to CP-525-communication
    Quickbestellung INFOMAIL
    by e-mail
    46,00 €
    plus VAT. and shipping


    9359-5-150-USB
    PG-USB AG-150-adapter

    for PG-USB-cable + S5-LAN++ (from HW2.3) to AG-150
    Quickbestellung INFOMAIL
    by e-mail
    46,00 €
    plus VAT. and shipping


    9359-7-USB
    PG-USB-lengthening set

    complete assembling set
    Quickbestellung INFOMAIL
    by e-mail
    46,00 €
    plus VAT. and shipping


    All prices plus costs of delivery, shipping insurance and VAT.

    9359-1
    PG-USB-cable 3m for Siemens S5 Controller

    for PLC's + LED + metal case
    Quickbestellung INFOMAIL
    by e-mail
    145,00 €
    plus VAT. and shipping




    maximum 3 articles
    9359-1.05M
    PG-USB-cable 5m for Siemens S5 Controller

    for PLC's + LED + metal case
    Quickbestellung INFOMAIL
    by e-mail
    174,00 €
    plus VAT. and shipping




    maximum 3 articles
    All prices plus costs of delivery, shipping insurance and VAT.

    9855-S7-0
    PG-2000 STEP7 FREEWARE
    without support / guarantee
    Quickbestellung INFOMAIL
    by e-mail
    0,00 €
    plus VAT. and shipping


    9352-LANCON
    S7-LAN connector for Siemens S7 PLC controller

    Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
    Quickbestellung INFOMAIL
    by e-mail
    423,00 €
    plus VAT. and shipping


    9359-LAN
    S5-LAN++

    Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
    Quickbestellung INFOMAIL
    by e-mail
    452,00 €
    plus VAT. and shipping


    9851
    PG-2000 STEP5-STL single license

    representation statementlist for Siemens S5
    Quickbestellung INFOMAIL
    by e-mail
    304,00 €
    plus VAT. and shipping


    421,00 €
    plus VAT. and shipping


    9855
    PG-2000 STEP5 complete package

    single license STL + LAD + CFS
    Quickbestellung INFOMAIL
    by e-mail
    675,00 €
    plus VAT. and shipping