TINA - mobile intelligent network-analyser
Simple Network-troubleshooting +++ Webserver operation/control +++ Networkanalysis 10/100 MBit without effort +++ To PC with 2,4 GHz +++ Detection network violations +++ Resolve IP-address conflicts +++ PROFINET monitori
Universal LAN/WIFI-S7-Adapter
Features:- Non-reactive recording of Ethernet communication
- Secure and passive decoupling of telegrams
- Monitors all OSI layers starting from layer 2 and packets of all sizes and types and VLAN traffic
more...
ARTNR: 9352-S7-WIFI
S7-BRIDGE
EAN number: | 4260363249317 | |
HS-code: | 85423190 | |
Weight: | 0.6 kg |
S7
PPI-Bus | |||||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||||
USB | |||||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||||
LAN | |||||||||
10/100BaseTx |
x(7)
|
x
|
x
|
x
|
x
|
||||
WIFI | |||||||||
2.4 GHz |
x
|
||||||||
TeleService operation | |||||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||||
baud rates at TS-operation directly at the PC | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||||
baud rates at TS-operation directly with a modem | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x
|
x
|
|||||||
115.2 KBit/s |
x
|
x
|
|||||||
HMI | |||||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||||
PLCVCOM |
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
RFC1006 |
8
|
8
|
32
|
32
|
32
|
||||
AG connections (maximum) | |||||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||||
integrated PLC-firewall |
|
|
x
|
x
|
x
|
||||
display diagnostic-buffer in the webbrowser |
|
|
x
|
x
|
x
|
||||
webserver for configuration |
x
|
x
|
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
x
|
x
|
||||
galvanic separation | |||||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
1,5KV
|
1,5KV
|
mounting | |||||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||||
upgrading with | |||||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||||
supports | |||||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win11 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1 (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3 (3) only serial communication (4) Siemens Step7 V5.2 and higher dont run with this operationing system (5) USB-communication is only possible with the special driver for Win NT (6) USB 2.0 is backward compatible to 1.1 (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation (8) only in combination with the MPI-Speed-driver („continously-active“) (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional) (11) only in the mode: MultiMaster-Mode (12) up to a maximum baud rate of 187.5 KBit/s (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port. (14) with the use of the TS-adapter / item number: 9350.TS (15) Update directly with PC and TIC-driver (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens (19) only at PPI-communication possible (20) Only with TIC-driver (21) with integrated webserver possible (22) No support of Siemens Step7-software possible (23) Only with USB and with TIC-driver |
- Non-reactive recording of Ethernet communication
- Secure and passive decoupling of telegrams
- Monitors all OSI layers starting from layer 2 and packets of all sizes and types and VLAN traffic
- For 10 or 100Mbit/s
- To monitoring-PC with WIFI 2,4 GHz
- Complete operation (display and parameterization) via web server via WLAN.
- No extra recording devices and no cumbersome analysis software must be installed.
- Perfect for mobile devices.
- Immediate e-mail alerting for surveillance violations.
- Thanks to immediate alerting, with freely adjustable violations, not network error will be missed again.
- By using the timestamp exact identifying the point of the network error in the analysis will be no problem any more .
- Display of subscriber connections (which subscriber accesses which subscriber).
- M2M connections are now transparent! TINA shows exactly who communicates with whom at the IP level . Missing or incorrect network connections can be determined directly.
- Inconsistencies in accessing certain subnets ? We will show each connection directly with source and destination address incl. all data.
- Simple Exchange of IP addresses in order to be able to communicate with the device in another subnet (eg S7-LAN).
- For IP address conflicts TINA can intervene directly and change the "wrong" IP address directly.
- Regardless of whether devices are hanging in direct access or are removed, thanks to network protocol transmission , values ??for the corresponding device can be changed directly in the TINA web server.
- Read and write Wireshark files
- For later post-processing or for sharing with others, the recording format is 100% Wireshark compatible . This allows a later evaluation on each PC, detached from the recording hardware.
- Wireshark records can also be imported into the TINA interface for comparison or verification.
- Network tools like Ping, Traceroute, ... integrated
- Full function of all popular "fast" analysis functions as you know from the PC.
Product Overview:
TINA is a handy device for analyzing network problems and network conflicts .
The device is plugged directly into the network cable without any further switches or peripherals.
With user rights and password protection, access via both LAN and WLAN is possible and well secured.
No PC with installed software is required for operation, the complete configuration and recording process takes place in the integrated web server.
Surveillance violations are reported directly by e-mail, special rules therefore can be specifically assigned.
Thanks to TINA, it´s now possible to find network problems and analyze network errors in a few minutes coupled with immediately bug fixing.
The network analysis includes functions such as IP conflicts, SUB-NET errors, runtime errors, missing subscribers due to subscriber failure and much more.
Application areas:
- Exposure of burglary and unauthorized access to your company network.
- Help with commissioning, third-party machines can be analyzed and adjusted.
- Analysis of VoIP protocols and audio voice output in case of problems with your telephone system
- Detecting Address Conflicts
- Find and analyze network problems and fix them directly.
- Check LAN connections for your failure risk ( Re-transmission ...)
- Search, scan and exchange IP addresses and record their communication.
- monitoring of complete network segments.
Configuration:
A configuration interface created for common systems eliminates the need for a long time in the system.
Most settings in the network area are quick and easy to set even for inexperienced users.
Thanks to free creatable rules and monitoring modes no unauthorized access and no unauthorized device escapes the attention.
The entire control and release monitoring must also be set directly in the web server like the rest of the configuration.
Recording and analysis directly in the web server, also for mobile devices:
Network analyzes and recordings can be started and operated directly in the web server.
Network packets are recorded and displayed in detail and divided into categories.
All settings are optimized for fast and easy operation.
Control surfaces extra large and simple, so the network analysis can also be performed with smartphones .
Wired or wireless communication (WIFI) via the same adapter with the respective control
Always connected to each other, all made possible by the devices of the BRIDGE-family.
Wired or wireless communication (WIFI) via the same adapter with the respective control
Always connected to each other, all made possible by the devices of the BRIDGE-family.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 3 watt |
Display: |
Web-Browser 3 status-LEDs (of that 1 double-led) |
Handling/Configuration: |
Web-Browser TIC-Software Configuration-tool |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
PD/diagnosis jack10/100BaseTX RJ45-ethernet jack Antenna-plug RP-SMA(f) (IEEE 802.11 b/g/n) |
Galvanic separation: | 1500V PPI/MPI/Profibus to the PC |
Operating systems: | MS-Windows NT, 2000, XP, Vista / Win7/8/10/11 32/64 Bit |
Protocols: | RFC1006, DHCP, HTTP |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 120 x 43 x 17 mm |
Scope of delivery: |
S7-BRIDGE-module WIFI-stub antenna Power connector 2pins small |
accessories:
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Stationary antenna for wall fastening
for ALF and CONNECT-ROUTER, cable length: 2,5m for indoor and outdoor use incl. wall holder
plus VAT. and shipping
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
plus VAT. and shipping
plus VAT. and shipping
Sector antenna for ALF
Sector antenna with 17dBi power gain and bundled radiation. Connection cable optional
plus VAT. and shipping
Beam antenna for ALF
Beam antenna with 17dBi power gain for classic radio link connection cable optional
plus VAT. and shipping
plus VAT. and shipping
Magnetic base antenna for indoor use
for ALF, ALF-UA- S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m
plus VAT. and shipping
plus VAT. and shipping
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
plus VAT. and shipping
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
plus VAT. and shipping
S7-BRIDGE
Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI
plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping
S7-GATE connector with integrated firewall for Siemens S7-PLCs
Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
plus VAT. and shipping
S7-LAN++ connector for Siemens S7 Controller
Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
plus VAT. and shipping
LAN
smallest simatic S7 ethernet gateway with PD-socket, multifunctional, 1 adapter for all PPI, MPI and Profibus applications
with ext. 24V-connector
easy remote maintenance over internet
S7-cable PPI/MPI/PROFIBUS +++ Ethernet-gateway S7 as cable +++ Network for each S7-PLC +++ Parallel LAN access +++ Ethernet for each S7-PLC
WLAN/WIFI
Service-suitcase for couppling to a PLC over LAN/WLAN incl. all accessories
Over WLAN to PLC and ethernet-communication-modules
S7-adapter PPI/MPI/PROFIBUS +++ including PLC-firewall +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN++ Connector with integrated firewall for Siemens S7-PLCs
plus VAT. and shipping
plus VAT. and shipping
Magnetic base antenna for indoor use
for ALF, ALF-UA- S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m
plus VAT. and shipping
plus VAT. and shipping
Automatic-mode
Main downloads
Versionstory
Documentation
- Short instruction
- Example PUT/GET for Simatic-Manager and TIA-portal
- Examples of S5-/S7-coupling (S5-PLC and/or S7-PLC active)
- Information-sheet S7-LAN
- Handbook S5-/S7-BRIDGE
- Short instruction S7-interface (german only)
- Short instruction S7-LAN
- Example of use: Watchdog-option
- Handbook S7-LAN (older version)