MPI-USB



S7-Interface cable for PPI, MPI, Profibus, HMI <=> USB applications
- Supplied driver TIC (Total Integrated Communication) (runs under Win XP, VISTA, Win7/8/8.1, Win10) allows communication and configuration of the interface product
- Function with TIA-Portal and Simatic-Manager, also with WinCC and Comfort Panel
- Automatic protocol- and baud rate detection (depends on the used product from 9K6 to 12M)
- Connects only to the bus when it is requested by PG
- Firmwareupdate via internet for free
- PPI - adapter for S7 - 200
- MPI/Profibus - adapter for S7 - 300 + 400
- CE/EMC compliant construction
- All intelligent MPI-interface-products including a free OPC-server license "OPC-Manager lite" [limited to 100 items]
more...
299,- €
plus VAT. and shipping
plus VAT. and shipping
ARTNR: 9352-USB
MPI-USB-cable 3m
EAN number: | 4260363240598 |
HS-code: | 85444290 |
Weight: | 0.24 kg |
S7
PPI-Bus | |||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||
19.2 KBit/s |
x
|
x
|
|||||
38.4 KBit/s |
x
|
x
|
|||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||
USB | |||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||
LAN | |||||||
10/100BaseTx |
x(7)
|
x
|
x
|
||||
WIFI | |||||||
2.4 GHz |
x
|
||||||
TeleService operation | |||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||
baud rates at TS-operation directly at the PC | |||||||
9.6 KBit/s |
x
|
x
|
|||||
19.2 KBit/s |
x
|
x
|
|||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||
baud rates at TS-operation directly with a modem | |||||||
9.6 KBit/s |
x
|
x
|
|||||
19.2 KBit/s |
x
|
x
|
|||||
38.4 KBit/s |
x
|
x
|
|||||
57.6 KBit/s |
x
|
x
|
|||||
115.2 KBit/s |
x
|
x
|
|||||
HMI | |||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||
PLCVCOM |
1
|
1
|
8
|
1
|
8
|
8
|
|
RFC1006 |
x
|
x
|
x
|
||||
AG connections (maximum) | |||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||
webserver for configuration |
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
||||
galvanic separation | |||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
mounting | |||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||
upgrading with | |||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||
supports | |||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|

Stephan Kern Elektrotechniker / Elektromeister
Schleching

Zeller Presscontrol Systems und Automatisierungstechnik e.K.
Wiesensteig
www.zeller-presscontrol.com
- Supplied driver TIC (Total Integrated Communication) (runs under Win XP, VISTA, Win7/8/8.1, Win10) allows communication and configuration of the interface product
- Function with TIA-Portal and Simatic-Manager, also with WinCC and Comfort Panel
- Automatic protocol- and baud rate detection (depends on the used product from 9K6 to 12M)
- Connects only to the bus when it is requested by PG
- Firmwareupdate via internet for free
- PPI - adapter for S7 - 200
- MPI/Profibus - adapter for S7 - 300 + 400
- CE/EMC compliant construction
- All intelligent MPI-interface-products including a free OPC-server license "OPC-Manager lite" [limited to 100 items]
- All products, including the examples and demo-version of communication driver as download on the product-site
- Master-class 2 for acyclic services (DPV1)
- Power-supply from USB
- Double-sided connected cable
- Short plug to PLC
Access to MPI/Profibus without power supply

Your’re right in the middle of your production line and are standing in front of a passive assembly just like a switcher or a ET200, in that case you won’t be able to go Online without
an external power supply of your programming adapter, unless you’re using the MPI-USB. This cable is supplied completely from the USB-interface.
Supply voltage: | 5V DC |
Power consumption: | 2 watt |
Display: | double lined LCD-display |
Handling/Configuration: |
Kabelmanager-Software keypad on the back |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
USB 1.1 cable type A |
Galvanic separation: | 1000V PPI/MPI/Profibus to the PC |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 146 x 41 x 29 mm |
Scope of delivery: | |
MPI-USB-cable |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
25,- €
plus VAT. and shipping
plus VAT. and shipping
35,- €
plus VAT. and shipping
plus VAT. and shipping
5,- €
plus VAT. and shipping
plus VAT. and shipping
5,- €
plus VAT. and shipping
plus VAT. and shipping
315,- €
plus VAT. and shipping
plus VAT. and shipping
415,- €
plus VAT. and shipping
plus VAT. and shipping
79,- €
plus VAT. and shipping
plus VAT. and shipping
9352-S7-BK
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x

39,- €
plus VAT. and shipping
plus VAT. and shipping
143,- €
plus VAT. and shipping
plus VAT. and shipping
10,- €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
Variationen:
324,- €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
9352-LANCON
S7-LAN connector for Siemens S7 PLC controller
Simatic S7 network adapter for PPI-MPI-PROFIBUS / network for every S7 controller in less than 3 minutes
S7-LAN connector for Siemens S7 PLC controller
Simatic S7 network adapter for PPI-MPI-PROFIBUS / network for every S7 controller in less than 3 minutes

399,- €
plus VAT. and shipping
plus VAT. and shipping
125,- €
plus VAT. and shipping
plus VAT. and shipping
9350-9-DIAG
DiagConn 90° Highend-connector
for PROFIBUS with diagnosis function country of origin: Germany not preferential
DiagConn 90° Highend-connector
for PROFIBUS with diagnosis function country of origin: Germany not preferential

43,- €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions