CONNECT-CONTROL with worldwide LTE
With ACBT through firewall +++ No on-site PC necessary +++ Internet without IT-knowledge
Universal LAN/WIFI-S5-Adapter
ACBT-Technologie: (AUTO-CONNECT and BYPASS TUNNEL)Product overview:
Remote maintenance of systems/machines with the devices of the CONNECT-family without the use of the IT-department
The use makes no demands on the user, working according to the motto:
! Unpack, switch on, work !
benefits:
• Remoteservice/Maschinenzugriff without configuration/IT-knowhow:
C ommunication
more...
ARTNR: 9359-S5-WIFI
S5-BRIDGE
EAN number: | 4260363249409 | |
HS-code: | 85423190 | |
Weight: | 0.1 kg |
Alternativen
plus VAT. and shipping
S7-BRIDGE
Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
S5-BRIDGE
ONLINE with S5PLC without cable +++ S5-adapter 90-155U/CPs/IPs +++ No WIFi-infrastructure +++ Integrated access-point +++ Configuration via WebAccess +++ S5 Bridge (TTY - LAN - WIFI)
plus VAT. and shipping
S5
device type | ||||||
S5-90U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-95U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-100U |
x
|
+ext. 24V(3)
|
+ext. 24V
|
x
|
x
|
x
|
S5-115U |
at 944 + 9359-8
|
at 944 + 9359-8 + ext. 24V (4)
|
x
|
x
|
x
|
x
|
S5-135U |
at 928B + 9359-8
|
at 928B + 9359-8 +ext. 24V (6)
|
x
|
x
|
x
|
x
|
S5-155U |
x
|
x
|
x
|
x
|
x
|
x
|
S5-AG110S |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG130W/B |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG150A/K/S/U |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
CP-143 |
x
|
x
|
x
|
|||
CP-521 |
+CP521 adapter
|
+CP521 adapter(1)
|
||||
CP-523 |
+CP523 adapter
|
+CP523 adapter(1)
|
||||
CP-525 |
+9359-5(1)
|
|||||
CP-526 |
x
|
x
|
x
|
|||
CP-527 |
x
|
x
|
x
|
|||
CP-528 |
x
|
x
|
x
|
|||
CP-544 |
x (7)
|
x (7)
|
x (7)
|
|||
CP-5430 |
x
|
x
|
x
|
|||
CP-5431 |
x
|
|||||
IP-246 |
x
|
x
|
x
|
|||
IP-247 |
x
|
x
|
x
|
|||
IP-252 |
x
|
x
|
x
|
|||
IP-266 |
x
|
+9359-4(1)
|
||||
WF-470 |
+9359-5-WF470 + 9359-4(1)
|
|||||
SIN-805 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-820 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-840 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-850 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-880 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
Connection on PC |
RS232-port
|
Ethernet RJ45
|
Ethernet RJ45 / WLAN/WIFI
|
USB-port type A
|
RS232-port
|
RS232-port
|
max. prolongation: | 300m (UNI-extension) | 300m (S5-LAN-extension) +ext. 24V | 100m (PG-USB-extension) | 300m (UNI-extension) | ||
(1) ISO adapter can not be used because the required supply voltage on the PG interface of the module is not present. (2) At the CPU 6ES5 102-8MA02 Release 3 is a PG-ISO-Adapter or Netz-Adapter additional required. (3) With S5-LAN++ from HW V2.3 [2010] the "Netz-Adapter" is no more needed, this version has included current-sources. (4) With S5-LAN++ from HW V2.3 [2010] no accessories are needed, this version has included current-sources. (5) With S5-LAN++ from HW V2.3 [2010] the Sinum-Adapter 9359-6-USB is needed. (6) Only for CPU928B with PG-ISO-Adapter and ext. 24V DC, unless there is an S5-LAN++ from HW V2.3 [2010] used. (7) CP544 has bolts at the programming-interface. The products do not fit 100% on this interface. (8) With S5-BRIDGE the Sinum-Adapter 9359-6-USB is needed. |
Product overview:
Remote maintenance of systems/machines with the devices of the CONNECT-family without the use of the IT-department
The use makes no demands on the user, working according to the motto:
! Unpack, switch on, work !
benefits:
• Remoteservice/Maschinenzugriff without configuration/IT-knowhow:
C ommunication
O hne (without)
N etzwerk-Kenntnisse - (network-knowhow)
N ur (only)
E instecken, (pluggin)
C onnecten => (connect)
T echnik mal einfach (technology times easy)
• No hidden costs, any prepaid card with LTE
• No installation of additional software tools
• Avoidance of on-site maintenance-work through remote-access
• No PC required on site
• Switch on only, automatic connection establishment (no portal login)
• Access to every LAN participant with TCP- and UDP-protocols:
- PCs in this net
- Panel in this net
- S7-controls over S7-TCPIP or S7-LAN, S7-GATE, S7-BRIDGE
- S5-controls over S5-LAN++
- SINUMERIK 840D/840D SL
- Mitsubishi-controls MELSEC IQR, FX5, QnA and L-series
- Rockwell-controls Controllogix and Compactlogix
- Bosch Rexroth-controls
- Beckhoff TwinCAT-controls
- B&R-control-systems
• Workplaces at the same time in parallel on different participants on site
• Remote-access to customer systems without an intranet
• Connection without much effort
• Only your devices are visible in the cloud
• Encrypted transmission between the CONNECT-devices
• Quick and easy configuration with WebInterface, no unnecessary input masks
• Integrated firewall regulates access from the intranet to the machine network
• Remote access to all devices in the cloud
• Import / export configuration between devices in the cloud
• Integrated diagnostic tools on site for network-analysis
[HOME]
[FACTORY]
No network connection on the machine available?
CONNECT-LTE + Standard SIM-card = communication over LTE
Accessories:
Connection of most S5/7 controls by using our additional devices "S7-LAN, S7-BRIDGE, S5-LAN++, S5-BRIDGE or ALF-UA" directly to the CONNECT via cable or via WIFI.
Watch the S5-controller, transfer parallel the S7-controller-program, work as if you were sitting in front of the machine.
No time for configuration as plant-/production-stoppage?
==> CONNECT-PROJECT
We parameterize all devices and additional devices for you according to your specifications, send them to you and “neutral” to your end customer. No one has to change or adapt the parameterization:.
==> "Unpack, switch on, work"
Wired or wireless communication (WIFI) via the same adapter with the respective control
Always connected to each other, all made possible by the devices of the BRIDGE-family.
Kommunikation kabelgebunden oder auch kabellos (WIFI) über den selben Adapter mit der jeweiligen S5-SPS
Geräte der S5-BRIDGE-Familie verbinden immer kabelgebundenes Netzwerk mit kabellosem Netzwerk (WIFI) und spezifischer S5-PG-Schnittstelle.
Sie haben somit über WIFI Zugriff auf die direkt angeschlossene Steuerung sowie am kabelgebunden Ethernet.
Natürlich auch vom kabelgebundenen Ethernet auf WIFI und Steuerung.
Immer zueinander in Verbindung, alles durch die Geräte der S5-BRIDGE-Familie ermöglicht.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 3 watt |
Display: | status-LED |
Handling/Configuration: |
reset-switch-key (factory setting) S5-LAN Manager website-configuration |
Interfaces: |
to the PLC:
TTY/20mA current loop (S5-LAN activ, S5-PLC passive)
to the PD/PC:
10/100BaseTX RJ45-ethernet jackAntenna-plug RP-SMA(f) (IEEE 802.11 b/g/n) |
Operating system: |
Configuration and operation via virtual COM-interface: MS-Windows XP/2000/7/8/10/11/Server Operation via TCP/IP server: any operating system with a TCP/IP stack |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 100 x 58 x 21 mm |
Scope of delivery: |
S5-BRIDGE-module WIFI-stub antenna Power connector 2pins small |
accessories:
plus VAT. and shipping
plus VAT. and shipping
Stationary antenna for wall fastening
for ALF and CONNECT-ROUTER, cable length: 2,5m for indoor and outdoor use incl. wall holder
plus VAT. and shipping
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
plus VAT. and shipping
plus VAT. and shipping
Sector antenna for ALF
Sector antenna with 17dBi power gain and bundled radiation. Connection cable optional
plus VAT. and shipping
Beam antenna for ALF
Beam antenna with 17dBi power gain for classic radio link connection cable optional
plus VAT. and shipping
plus VAT. and shipping
Magnetic base antenna for indoor use
for ALF, ALF-UA- S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m
plus VAT. and shipping
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
plus VAT. and shipping
S5-BRIDGE
ONLINE with S5PLC without cable +++ S5-adapter 90-155U/CPs/IPs +++ No WIFi-infrastructure +++ Integrated access-point +++ Configuration via WebAccess +++ S5 Bridge (TTY - LAN - WIFI)
plus VAT. and shipping
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
plus VAT. and shipping
S5 over LAN
Network-connection for the S5-PLC +++ Network to PG-interface +++ Of developer and manufacturer +++ Remotemaintenance via Internet +++ S5 (CP-343-1 compatible)
S5 over WLAN/WIFI
Service-suitcase for couppling to a PLC over LAN/WLAN incl. all accessories
Over WLAN to ethernet-communications-modules
Magnetic base antenna for indoor use
for ALF, ALF-UA- S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Transport-suitcase including deposits
With lock Shockproof, can be without packaging be sent
plus VAT. and shipping
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
plus VAT. and shipping
Automatic-mode
Main downloads
- Firmware for S5-/S7-BRIDGE (router-function) V1.09