CONNECT-II-Remote-Access
With ACBT through firewall +++ No on-site PC necessary +++ Internet without IT-knowledge
Supply voltage: 24V DC
4 x Analogue Input (switchable between U, I,
differential)
4 x analog OUT 0/4-20mA (24V)
LAN and WIFI-interface integrated
function to the same time
Product overview:
Remote maintenance of systems/machines with the devices of the CONNECT-family without the use of the IT-department
The use makes no demands on the user, working according to the motto:
! Unpack, switch on, work !
benefits:
• Remoteservice/Maschinenzugriff without configuration/IT-knowhow:
C ommunication
more...
ARTNR: 9200-A-24V-V1.1
EtherSens Control 24V Analog-IO V1.1
EAN number: | 4260363246972 | |
HS-code: | 85423190 | |
Weight: | 0.2 kg |
Product overview:
Remote maintenance of systems/machines with the devices of the CONNECT-family without the use of the IT-department
The use makes no demands on the user, working according to the motto:
! Unpack, switch on, work !
benefits:
• Remoteservice/Maschinenzugriff without configuration/IT-knowhow:
C ommunication
O hne (without)
N etzwerk-Kenntnisse - (network-knowhow)
N ur (only)
E instecken, (pluggin)
C onnecten => (connect)
T echnik mal einfach (technology times easy)
• No hidden costs, any prepaid card with LTE
• No installation of additional software tools
• Avoidance of on-site maintenance-work through remote-access
• No PC required on site
• Switch on only, automatic connection establishment (no portal login)
• Access to every LAN participant with TCP- and UDP-protocols:
- PCs in this net
- Panel in this net
- S7-controls over S7-TCPIP or S7-LAN, S7-GATE, S7-BRIDGE
- S5-controls over S5-LAN++
- SINUMERIK 840D/840D SL
- Mitsubishi-controls MELSEC IQR, FX5, QnA and L-series
- Rockwell-controls Controllogix and Compactlogix
- Bosch Rexroth-controls
- Beckhoff TwinCAT-controls
- B&R-control-systems
• Workplaces at the same time in parallel on different participants on site
• Remote-access to customer systems without an intranet
• Connection without much effort
• Only your devices are visible in the cloud
• Encrypted transmission between the CONNECT-devices
• Quick and easy configuration with WebInterface, no unnecessary input masks
• Integrated firewall regulates access from the intranet to the machine network
• Remote access to all devices in the cloud
• Import / export configuration between devices in the cloud
• Integrated diagnostic tools on site for network-analysis
[HOME]
[FACTORY]
No network connection on the machine available?
CONNECT-LTE + Standard SIM-card = communication over LTE
Accessories:
Connection of most S5/7 controls by using our additional devices "S7-LAN, S7-BRIDGE, S5-LAN++, S5-BRIDGE or ALF-UA" directly to the CONNECT via cable or via WIFI.
Watch the S5-controller, transfer parallel the S7-controller-program, work as if you were sitting in front of the machine.
No time for configuration as plant-/production-stoppage?
==> CONNECT-PROJECT
We parameterize all devices and additional devices for you according to your specifications, send them to you and “neutral” to your end customer. No one has to change or adapt the parameterization:.
==> "Unpack, switch on, work"
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PN-port to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on SD card
Via digital input triggered DB-backup/-restore without additional PC via PN-port to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via PN-port to USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PN-port to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on SD-card
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to USB-stick
By connecting a line-recorder to the EtherSens-device anyone without network-knowledge can visually capture and further process the log.
Apply small control tasks of your systems with EtherSens-Control-devices. Determine switching points where the device is running to respond. Depending on the parameterization, an email or SMS notification (depending on the device-configuration) or the device automatically controls via the optional IO-modules (analog / digital / relay).
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 6 watt (without possibly switched outputs) |
Display: |
WEB-Browser 1 status LED bicolor |
Handling/Configuration: | WEB-Browser |
Interfaces: |
4 x Analogue Input V1.1 (switchable between U, I, differential) - Free configurable voltage-inputs with full 15-bit resolution: 0-50V, 0-40V, 0-20V, 0-10V, 0-5V, 0-4V, 0-2V, 0-1V, 0-0,5V, 0-0,25V - Free configurable differential voltage-inputs with full 15-bit resolution AI1 <-> AI2 and AI3 <-> AI4: +/-50V, +/-40V, +/-10V, +/-5V, +/-4V, +/-2V, +/-1V, +/-0,5V, +/-0,25V - Free configurable current-inputs with full 15-bit resolution: 0-20mA, 4-20mA - sample-rate of AD-converter can be selected: - fast = fast conversion / short precision - balanced = middle conversion / middle precision - exact = slow conversion / high precision - Measuring ranges after changing are calibrated to: - offset for 0V / 0mA - slope of voltage / current (ideal for end of measuring-range / full-scale) - Relative values can be configured to the original voltage- / current-values. For e.g.: On the voltage-input 10V were measured 5V, relative minimum = 0 kg, relative maximum = 100 kg, so the displayed-value is 50 kg Is minimum and maximum configured as 0 the measured voltage- / current-value will be displayed. 4 x analogue Output 0/4-20mA (source-power 24V) Slot for microSD Antenna-connector SMA(f) (2.4 GHz IEEE 802.11b/g) 10/100BaseTX RJ45-ethernet-plug Button for factory settings |
Overvoltage category: | CAT IV |
Insulation value network <=> mains voltage: |
1,5 KV |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case V0 |
Dimensions: | 100 x 112 x 45 mm |
Scope of delivery: |
EtherSens Control WIFI-stub-antenna |
accessories:
plus VAT. and shipping
plus VAT. and shipping
Stationary Wifi-antenna for wall fastening
for EtherSens-devices, cable length: 5m for indoor and outdoor use incl. bracket
plus VAT. and shipping
Option Safe S7-PLC-data-transmission
Function extension for recognition of save data-transmission by toggle bit or counters in the S7-PLC. In case of a failure, a default configuration is mapped to the outputs.
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
extensions:
Extension Analog-IO V1.0
Extension-board for EtherSens-devices 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Extension with ext. galv. separated I2C 5V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 5V Power consumption: 2W
plus VAT. and shipping
Extension LTE-modem
LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
plus VAT. and shipping
Extension Energy-IO
Extension-board for EtherSens-devices Energy-analysis (EN 50470-1 EN 50470-3) L1, L2, L3, N realtime analysis Up to 8000 measurements / second Hz / cos phi / power-factor Energy consumption kWh For Rogwski-coils up to 0,5V
plus VAT. and shipping
U-I-box for EtherSens
max. 1000V DC / 40A 24V DC supply 20cm power-cable 4mm2 with Amphenol-plug I2C-connection 1m
plus VAT. and shipping
Sun-light-sensor for EtherSens
max. 220k Lux (switchable ranges) 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 312 for EtherSens
Measuring range: ±1.5g / ±3g / ±6g / ±12g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 313 for EtherSens
Measuring range: ±0.5g / ±1g / ±2g / ±4g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Temp./humidity/air-pressure for EtherSens
Measuring range: Temperature: -40 ...+85°C Humidity: 0...100% relative Feuchte Pressure: 300...1100 hPa 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Segment-display for EtherSens
4 Digit 14 segment-display WHITE 0,56" high in wall-mounting case 5V DC supply (from I2C-interfaceport) I2C-connection
plus VAT. and shipping
Extension with ext. galv. separated I2C 3.3V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W
plus VAT. and shipping
Extension RS485-IO
Extensionboard for EtherSens-devices V1.0 for RS485 Power consumption: 2W
plus VAT. and shipping
Extension TTY-IO
Extensionboard for EtherSens-devices V1.0 for TTY (incl. 2x current-sources) Power consumption: 2W
plus VAT. and shipping
Extension Digital-IO
Extension-board for EtherSens-devices 12 x digital IN or OUT 24VDC 400mA free config with software Power consumption: 4W
plus VAT. and shipping
Extension 24V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 24V DC 4 x relay-OUT 230VAC/16A Power consumption: 4W
plus VAT. and shipping
Extension 230V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 230V AC 4 x relay-OUT 230VAC/16A Power consumption: 2,5W
plus VAT. and shipping
Power-supply-rack-unit 230V
Input voltage: 100 - 240VAC 50-60Hz Output voltage: 24V DC Power: 4W
plus VAT. and shipping
Extension Analog-IO V1.1
Extension-board for EtherSens-devices 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Extension RS422-IO
Extensionboard for EtherSens-devices V1.0 for RS422 (4-wire) Power consumption: 2W
plus VAT. and shipping
Extension RS232-IO
Extensionboard for EtherSens-devices V1.0 for RS232 (RxD, TxD) Power consumption: 2W
plus VAT. and shipping
Extension USB-port
USB-port for EtherSens-devices (data storage) Extension for: - DB-backup/restoure-function - CSV-recording Maximum current: 200mA for 5V DC
plus VAT. and shipping
EtherSens Control 24V Analog-IO V1.1
Supply voltage: 24V DC 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Analog-IO V1.0
Supply voltage: 24V DC 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V 2x Analog-IO V1.0
Supply voltage: 24V DC 8 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 8 x analog OUT 0/4-20mA (24V) LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V 2x Analog-IO V1.1
Supply voltage: 24V DC 8 x Analogue Input (switchable between U, I, differential) 8 x analog OUT 0/4-20mA (24V) LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Analog-/Digital-IO V1.0
Supply voltage: 24V DC 12 x digital IN or OUT 24VDC 400mA free config with software 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Analog-/Digital-IO V1.0 o. LAN
Supply voltage: 24V DC 12 x digital IN or OUT 24VDC 400mA free config with software 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) Only LAN-interface
plus VAT. and shipping
EtherSens Control 24V Analog-/Digital-IO V1.1
Supply voltage: 24V DC 12 x digital IN or OUT 24VDC 400mA free config with software 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Analog-/Relay-IO
Supply voltage: 24V DC 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) 4 x Relay-OUT 230VAC/16A LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Analog-/Relay-IO V1.1
Supply voltage: 24V DC 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) 4 x Relay-OUT 230VAC/16A LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Digital-IO
Supply voltage: 24V DC 12 x digital IN or OUT 24VDC 400mA free config with software LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V 2x Digital-IO
Supply voltage: 24V DC 24 x digital IN or OUT 24VDC 400mA free config with software LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Digital-/Relay-IO
Supply voltage: 24V DC 12 x digital IN or OUT 24VDC 400mA free config with software 4 x Relay-OUT 230VAC/16A LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 230V Relay-IO
Supply voltage: 230V AC 4 x Relay-OUT 230VAC/16A LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Relay-IO
Supply voltage: 24V DC 4 x Relay-OUT 230VAC/16A LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
plus VAT. and shipping