TINA-II - mobile intelligent network-analyser 1GB
Simple Network-troubleshooting +++ Webserver operation/control +++ Network-analysis 10/100/1000 MBit without effort +++ To PC with 2,4 GHz + 5 GHz +++ Detection network violations +++ Resolve IP-address conflicts +++ PROFINEt-monitoring
Industrial Ethernet <> S5 PD-interface (TTY)
Including Gateway Plus and S7-TCP / IP
functions
- Non-reactive recording of Ethernet communication
- Secure and passive decoupling of telegrams
- Monitors all OSI layers starting from layer 2 and packets of all sizes and types and VLAN traffic
more...
ARTNR: 9359-LAN
S5-LAN++
EAN number: | 4260363240024 | |
HS-code: | 85423190 | |
Weight: | 0.05 kg |
S5
device type | ||||||
S5-90U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-95U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-100U |
x
|
+ext. 24V(3)
|
+ext. 24V
|
x
|
x
|
x
|
S5-115U |
at 944 + 9359-8
|
at 944 + 9359-8 + ext. 24V (4)
|
x
|
x
|
x
|
x
|
S5-135U |
at 928B + 9359-8
|
at 928B + 9359-8 +ext. 24V (6)
|
x
|
x
|
x
|
x
|
S5-155U |
x
|
x
|
x
|
x
|
x
|
x
|
S5-AG110S |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG130W/B |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG150A/K/S/U |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
CP-143 |
x
|
x
|
x
|
|||
CP-521 |
+CP521 adapter
|
+CP521 adapter(1)
|
||||
CP-523 |
+CP523 adapter
|
+CP523 adapter(1)
|
||||
CP-525 |
+9359-5(1)
|
|||||
CP-526 |
x
|
x
|
x
|
|||
CP-527 |
x
|
x
|
x
|
|||
CP-528 |
x
|
x
|
x
|
|||
CP-544 |
x (7)
|
x (7)
|
x (7)
|
|||
CP-5430 |
x
|
x
|
x
|
|||
CP-5431 |
x
|
|||||
IP-246 |
x
|
x
|
x
|
|||
IP-247 |
x
|
x
|
x
|
|||
IP-252 |
x
|
x
|
x
|
|||
IP-266 |
x
|
+9359-4(1)
|
||||
WF-470 |
+9359-5-WF470 + 9359-4(1)
|
|||||
SIN-805 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-820 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-840 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-850 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-880 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
Connection on PC |
RS232-port
|
Ethernet RJ45
|
Ethernet RJ45 / WLAN/WIFI
|
USB-port type A
|
RS232-port
|
RS232-port
|
max. prolongation: | 300m (UNI-extension) | 300m (S5-LAN-extension) +ext. 24V | 100m (PG-USB-extension) | 300m (UNI-extension) | ||
(1) ISO adapter can not be used because the required supply voltage on the PG interface of the module is not present. (2) At the CPU 6ES5 102-8MA02 Release 3 is a PG-ISO-Adapter or Netz-Adapter additional required. (3) With S5-LAN++ from HW V2.3 [2010] the "Netz-Adapter" is no more needed, this version has included current-sources. (4) With S5-LAN++ from HW V2.3 [2010] no accessories are needed, this version has included current-sources. (5) With S5-LAN++ from HW V2.3 [2010] the Sinum-Adapter 9359-6-USB is needed. (6) Only for CPU928B with PG-ISO-Adapter and ext. 24V DC, unless there is an S5-LAN++ from HW V2.3 [2010] used. (7) CP544 has bolts at the programming-interface. The products do not fit 100% on this interface. (8) With S5-BRIDGE the Sinum-Adapter 9359-6-USB is needed. |
Remote maintenance
TELE LINK NETWORK
|
||||||||
secured modem-protocol |
✓
|
✓
|
✓
|
|||||
additional software needed |
Siemens TS -Software
|
Siemens TS -Software
|
VPN-Client
|
VPN-Client
|
||||
Providing WinTELEPROF-software |
✓
|
✓
|
✓
|
|||||
modem |
analogue/ISDN
|
analogue
|
opt. via PCMCIA
|
analogue/GSM
|
analogue/ISDN/GSM
|
internet-connection
|
internet-connection
|
internet-connection
|
modem for world wide use |
✓
|
✓
|
✓
|
✓
|
✓
|
|||
interfaces | ||||||||
MPI/Profibus |
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
||||
RS232 |
2x
|
2x
|
2x
|
1x
|
1x
|
|||
TTY |
2x
|
2x
|
2x
|
1x
|
||||
PCMCIA |
2x (optionally)
|
1x
|
1x
|
|||||
Ethernet |
10/100BaseTx
|
1x
|
1x
|
5x
|
||||
USB |
2x
|
1x
|
||||||
LCD-display |
✓
|
✓
|
✓
|
✓
|
instead 10 LEDs
|
instead status-LED
|
instead webserver
|
instead webserver
|
supported PLC-protocols * | ||||||||
S7 |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
||
S5 |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
||||
Pilz PSS |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
Allen-Bradley |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
AEG |
✓ (optional)
|
✓ (optional)
|
||||||
Bosch |
✓ (optional)
|
✓ (optional)
|
||||||
Telemecanique |
✓ (optional)
|
✓ (optional)
|
||||||
GE-Fanuc |
✓ (optional)
|
✓ (optional)
|
||||||
Klöckner-Moeller |
✓ (optional)
|
✓ (optional)
|
||||||
Mitsubishi |
✓ (optional)
|
✓ (optional)
|
||||||
SMS-sending/Pager(S5/S7) |
✓
|
✓
|
✓
|
✓ (no pager)
|
only for analogue / ISDN
|
|||
HMI-messaging module(S5/S7) |
✓
|
✓
|
||||||
SMS-receive with GSM |
✓
|
|||||||
DTMF with analogue |
✓
|
|||||||
e-mail-dispatch |
✓
|
✓
|
✓
|
|||||
FAX-dispatch(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
only for analogue / ISDN
|
||||
PLC-data coupling(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
✓
|
|||
ASCII-transfer from S5/S7 |
✓
|
✓ (optional)
|
✓ (optional)
|
only with ASCII-LAN
|
||||
internet-coupling |
✓
|
|||||||
Usage as dial-up-router |
✓
|
✓
|
||||||
power supply |
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
dimensions w x h x d (in mm) |
High: 67 x 280 x 170
FLAT: 300 x 175 x 70 |
300 x 175 x 66
|
235 x 162 x 37
|
90 x 162 x 54
|
40 x 125 x 115
|
42 x 15 x 65
|
65 x 43 x 17
|
154 x 92 x 28
|
* other PLC types on request |
- Non-reactive recording of Ethernet communication
- Secure and passive decoupling of telegrams
- Monitors all OSI layers starting from layer 2 and packets of all sizes and types and VLAN traffic
- For 10, 100 or 100Mbit/s
- To monitoring-PC with WIFI 2,4 GHz or 5 GHz
- Complete operation (display and parameterization) via web server via WLAN.
- No extra recording devices and no cumbersome analysis software must be installed.
- Perfect for mobile devices.
- Immediate e-mail alerting for surveillance violations.
- Thanks to immediate alerting, with freely adjustable violations, not network error will be missed again.
- By using the timestamp exact identifying the point of the network error in the analysis will be no problem any more .
- Display of subscriber connections (which subscriber accesses which subscriber).
- M2M connections are now transparent! TINA shows exactly who communicates with whom at the IP level . Missing or incorrect network connections can be determined directly.
- Inconsistencies in accessing certain subnets ? We will show each connection directly with source and destination address incl. all data.
- Simple Exchange of IP addresses in order to be able to communicate with the device in another subnet (eg S7-LAN).
- For IP address conflicts TINA can intervene directly and change the "wrong" IP address directly.
- Regardless of whether devices are hanging in direct access or are removed, thanks to network protocol transmission , values ??for the corresponding device can be changed directly in the TINA web server.
- Read and write Wireshark files
- For later post-processing or for sharing with others, the recording format is 100% Wireshark compatible . This allows a later evaluation on each PC, detached from the recording hardware.
- Wireshark records can also be imported into the TINA interface for comparison or verification.
- Network tools like Ping, Traceroute, ... integrated
- Full function of all popular "fast" analysis functions as you know from the PC.
Product Overview:
TINA-II is a handy device for analyzing network problems and network conflicts .
The device is plugged directly into the network cable without any further switches or peripherals.
With user rights and password protection, access via both LAN and WLAN is possible and well secured.
No PC with installed software is required for operation, the complete configuration and recording process takes place in the integrated web server.
Surveillance violations are reported directly by e-mail, special rules therefore can be specifically assigned.
Thanks to TINA-II, it´s now possible to find network problems and analyze network errors in a few minutes coupled with immediately bug fixing.
The network analysis includes functions such as IP conflicts, SUB-NET errors, runtime errors, missing subscribers due to subscriber failure and much more.
Application areas:
- Exposure of burglary and unauthorized access to your company network.
- Help with commissioning, third-party machines can be analyzed and adjusted.
- Analysis of VoIP protocols and audio voice output in case of problems with your telephone system
- Detecting Address Conflicts
- Find and analyze network problems and fix them directly.
- Check LAN connections for your failure risk ( Re-transmission ...)
- Search, scan and exchange IP addresses and record their communication.
- monitoring of complete network segments.
Configuration:
A configuration interface created for common systems eliminates the need for a long time in the system.
Most settings in the network area are quick and easy to set even for inexperienced users.
Thanks to free creatable rules and monitoring modes no unauthorized access and no unauthorized device escapes the attention.
The entire control and release monitoring must also be set directly in the web server like the rest of the configuration.
Recording and analysis directly in the web server, also for mobile devices:
Network analyzes and recordings can be started and operated directly in the web server.
Network packets are recorded and displayed in detail and divided into categories.
All settings are optimized for fast and easy operation.
Control surfaces extra large and simple, so the network analysis can also be performed with smartphones .
Replace defective panels in your "old" S5-systems with current and available S7-panels
To do this, simply insert a placeholder PLC (e.g. 315-2-PN / DP) in the WinCC-project, the IP-address
of the PLC corresponds to the IP-address of the S5-LAN++-module. You can then visualize the data as usual.
At the same time, the PLC can also be programmed/monitored via the network.
Move wirelessly around the S5-PLC and communicate for example ONLINE in the status
Connect each S7-TCP-IP panel to your S5.
Now also available via WLAN for mobile workstations.
PARALLEL several panels and even simultaneous PG connections possible.
Include hard-to-reach places in your ERP system.
With the S5-H1-PG-LAN you would be able to use the H1-path-selection over the S5-LAN++ and communicate with all PLCs in the H1-bus. You don´t have to connect serial to the CP, you can do this easy over your network.
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick
Coupling S5-controller with PD-port at S5-controller with PD-port via network
Coupling S7-controller with MPI/Profibus at S5-control with PD-port via network
Coupling S7-controller with PN-port at S5-controller with PD-port via network
Remote-maintenance of a Siemens-S5-controller with S5-LAN++ on PD-port via secure VPN-tunnel and scalable firewall
Remote-maintenance of a Siemens-S5-controller with S5-LAN++ on PD-port via secure VPN-tunnel of the TeleRouter
Remote-maintenance of a Siemens-S5-controller with S5-LAN++ on PD-port over separate VPN-server
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2 watt |
Display: | status-LED |
Handling/Configuration: |
reset-switch-key (factory setting) S5-LAN Manager |
Interfaces: |
to the PLC:
TTY/20mA current loop (S5-LAN activ, S5-PLC passive)
to the PD/PC:
10/100BaseTX RJ45-ethernet jack (auto select) |
Operating system: |
Configuration and operation via virtual COM-interface: MS-Windows XP/2000/7/8/10/11/Server Operation via TCP/IP server: any operating system with a TCP/IP stack |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 42 x 15 x 65 mm |
Scope of delivery: |
S5-LAN++-module Power connector 2pins small |
accessories:
Device upgrade S5-LAN to S5-LAN++
Hardware-update and firmware-upgrade from S5-LAN to S5-LAN++ Including checking the module
plus VAT. and shipping
Read PLC-data from 942F-SPS via S5-LAN++
Project license Communicatio-DLL 32-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++
Project license Communicatio-DLL 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++
Project license Communicatio-DLL LINUX 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic.
Site / Branch / Standort License Communicatio-DLL 32-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic
Site / Branch / Standort License Communicatio-DLL 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic
Site / Branch / Standort License Communicatio-DLL LINUX 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic
Site / Branch / Standort License Communicatio-DLL ARM Windows 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic
Site / Branch / Standort License Communicatio-DLL ARM LINUX 64-bit Function/call similar to IPS7-Link-DLL
plus VAT. and shipping
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
PG-USB AG-150-adapter
for PG-USB-cable + S5-LAN++ (from HW2.3) to AG-150
AG-150-adapter
for PG-UNI + PG-UNI-II-cable + S5-LAN++ (up to HW2.2) with Netz-Adapter to AG-150
SINUM-adapter
for PG-UNI + PG-UNI-II-cable + S5-LAN++ (up to HW2.2) to SINUMERIK
PG-USB SINUM-adapter
for PG-USB-cable + S5-LAN++ (from HW2.3) to SINUMERIK
plus VAT. and shipping
CP-525-K-adapter
for PG-UNI + PG-UNI-II-cable <-> CP-525- communication
CP-525-K-adapter for PG-USB + S5-LAN++
PG-USB-cable and S5-LAN++ (at east HW V2.3) to CP-525-communication
WF-470-adapter
for PG-UNI + PG-UNI-II-cable <-> WF470
PG-USB WF-470-adapter
for PG-USB-cable <-> WF470
plus VAT. and shipping
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
plus VAT. and shipping
S5-BRIDGE
ONLINE with S5PLC without cable +++ S5-adapter 90-155U/CPs/IPs +++ No WIFi-infrastructure +++ Integrated access-point +++ Configuration via WebAccess +++ S5 Bridge (TTY - LAN - WIFI)
plus VAT. and shipping
plus VAT. and shipping
S5-LAN++ RS232-version
Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
plus VAT. and shipping
S5-3964R-LAN RS232-version
Communication with 3964/9364R-client with S7-TCPIP inclusive adapter cable (15pin female <=> 9pin male)
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Internet
The simple and quick router solution for automation
Turbo ethernet for PLC-oldie Simatic S5
S5 over LAN
Simatic S5 ethernet gateway with Wifi for TTY
Remotesupport without configuration / Machine access without IT
Internet-coupling/communication
Remotesupport without configuration / Machine access without IT
smallest simatic S7 ethernet gateway with PD-socket, multifunctional, 1 adapter for all PPI, MPI and Profibus applications
with ext. 24V-connector
easy remote maintenance over internet
Industrial WLAN-Router +++ High-speed datarate 150 Mbit/s +++ Integrated firewall +++ Din-rail-mounting +++ Make your own WIFI
The simple and quick router solution for automation
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Automatic-mode
Main downloads
Versionstory
- Release-docu 3964R-LAN-firmware
- Release-docu ASCII-LAN-firmware
- Release-docu Multi-VCom
- Release-docu PLCVCom
- Release-docu S5-H1-PG-LAN-firmware
- Release-docu S5-LAN++-firmware
- Release-docu S5-LAN-Manager
- Release-docu S5-LAN-PATH-firmware
- Release-docu S5-Patch
- Release-docu S5-PG-LAN-firmware
- Release-docu S5-VCom