TINA-II - mobile intelligent network-analyser 1GB - Process Informatik Entwicklungsgesellschaft mbH

TINA-II - mobile intelligent network-analyser 1GB


Simple Network-troubleshooting +++ Webserver operation/control +++ Network-analysis 10/100/1000 MBit without effort +++ To PC with 2,4 GHz + 5 GHz +++ Detection network violations +++ Resolve IP-address conflicts +++ PROFINEt-monitoring

Industrial Ethernet <=> S5 PD-interface
(RS232), inclusive adapter cable
(15pin female <=> 9pin male)

Features:
  • Non-reactive recording of Ethernet communication

  • Secure and passive decoupling of telegrams

  • Monitors all OSI layers starting from layer 2 and packets of all sizes and types and VLAN traffic


    more...
    variants:

    555,00 € plus VAT. and shipping

    ARTNR: 9359-LAN-RS
    S5-LAN++ RS232-version
    EAN number: 4260363243599
    HS-code: 85444290



    Features:
    • Non-reactive recording of Ethernet communication

    • Secure and passive decoupling of telegrams

    • Monitors all OSI layers starting from layer 2 and packets of all sizes and types and VLAN traffic

    • For 10, 100 or 100Mbit/s

    • To monitoring-PC with WIFI 2,4 GHz or 5 GHz

    • Complete operation (display and parameterization) via web server via WLAN.
      • No extra recording devices and no cumbersome analysis software must be installed.
      • Perfect for mobile devices.

    • Immediate e-mail alerting for surveillance violations.
      • Thanks to immediate alerting, with freely adjustable violations, not network error will be missed again.
      • By using the timestamp exact identifying the point of the network error in the analysis will be no problem any more .

    • Display of subscriber connections (which subscriber accesses which subscriber).
      • M2M connections are now transparent! TINA shows exactly who communicates with whom at the IP level . Missing or incorrect network connections can be determined directly.
      • Inconsistencies in accessing certain subnets ? We will show each connection directly with source and destination address incl. all data.

    • Simple Exchange of IP addresses in order to be able to communicate with the device in another subnet (eg S7-LAN).
      • For IP address conflicts TINA can intervene directly and change the "wrong" IP address directly.
      • Regardless of whether devices are hanging in direct access or are removed, thanks to network protocol transmission , values ??for the corresponding device can be changed directly in the TINA web server.

    • Read and write Wireshark files
      • For later post-processing or for sharing with others, the recording format is 100% Wireshark compatible . This allows a later evaluation on each PC, detached from the recording hardware.
      • Wireshark records can also be imported into the TINA interface for comparison or verification.

    • Network tools like Ping, Traceroute, ... integrated
      • Full function of all popular "fast" analysis functions as you know from the PC.

    Product Overview:
    TINA-II is a handy device for analyzing network problems and network conflicts .
    The device is plugged directly into the network cable without any further switches or peripherals.
    With user rights and password protection, access via both LAN and WLAN is possible and well secured.
    No PC with installed software is required for operation, the complete configuration and recording process takes place in the integrated web server.
    Surveillance violations are reported directly by e-mail, special rules therefore can be specifically assigned.

    Thanks to TINA-II, it´s now possible to find network problems and analyze network errors in a few minutes coupled with immediately bug fixing.
    The network analysis includes functions such as IP conflicts, SUB-NET errors, runtime errors, missing subscribers due to subscriber failure and much more.



    Application areas:
    • Exposure of burglary and unauthorized access to your company network.
    • Help with commissioning, third-party machines can be analyzed and adjusted.
    • Analysis of VoIP protocols and audio voice output in case of problems with your telephone system
    • Detecting Address Conflicts
    • Find and analyze network problems and fix them directly.
    • Check LAN connections for your failure risk ( Re-transmission ...)
    • Search, scan and exchange IP addresses and record their communication.
    • monitoring of complete network segments.


    Configuration:
    A configuration interface created for common systems eliminates the need for a long time in the system.
    Most settings in the network area are quick and easy to set even for inexperienced users.




    Thanks to free creatable rules and monitoring modes no unauthorized access and no unauthorized device escapes the attention.
    The entire control and release monitoring must also be set directly in the web server like the rest of the configuration.



    Recording and analysis directly in the web server, also for mobile devices:
    Network analyzes and recordings can be started and operated directly in the web server.



    Network packets are recorded and displayed in detail and divided into categories.



    All settings are optimized for fast and easy operation.
    Control surfaces extra large and simple, so the network analysis can also be performed with smartphones .
    Visualisation via 3964R-interface without using the protocol itself
    Produkbild
    Your visualisation-software does not support a 3964R-protocol, but you have to apply this package? No problem, connect the 3964R-LAN to your CP and activate the RFC1006-emulation in the module. Now your software gets the data from the module via RFC1006, which in turn communicates with the assembly via 3964R.
    Extension of a 3964R-line via LAN
    Produkbild
    There is a control with CP524 in your outstation and the communication partner of the CP has moved locally. Connecting path is a LAN-network. So each of both participants gets a 3964R-LAN and after input of the partner’s IP-address a coupling via LAN will be configured.
    PLC coupling (data exchange between PLC’s)
    Produkbild
    Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Therefore no dedicated line is required, it’s sufficient when the stations connect via network (DSL-router).

    Produkbild

    With the S5-H1-PG-LAN you would be able to use the H1-path-selection over the S5-LAN++ and communicate with all PLCs in the H1-bus. You don´t have to connect serial to the CP, you can do this easy over your network.

    Remote maintenance of your S5-PLC via LAN / Internet
    Produkbild
    You have access to a on-site network and your PLC has no LAN-connection? No problem, plug the S5-LAN on the PLC and you will have immediate access to the PLC from afar.
    Programming of S5-PLC’s via LAN
    Produkbild
    You would like to respond to your S5-PLC via LAN, but not integrate an Ethernet-CP? No problem, plug the S5-LAN++ on the PD-interface and access via LAN.
    Communication with Win98 – XP/Vista/7/8/10/11 via network to S5-PLC
    Produkbild
    You still have a PC with Win98 and a MS-DOS-based Step5-package and would like to go Online on your S5-PLC via LAN? No problem, the provided virtual Com-Port PLCVCom emulates a COM-port on your PC with which you go Online. Even your MS-DOS-based Step5-software on this WIN98-PC can use this virtual Com-Port. With a patchtool for the Siemens Step5-software, which is provided as well, nothing else stands in your way to communicate via LAN.
    Watching of S5- PLC’s with panel for S7-PLC
    Produkbild
    Your panel only has a LAN-socket as PLC-interface and supports only S7-RFC1006, no problem. Connect this socket with the S5-LAN++ and plug it directly on the PD-interface of the PLC. The S5-LAN++ performs adverse your panel as a S7-PLC although you receive the data from the S5-PLC. Then access to the variables and data of the S5-PLC is already available.
    Watching of S5-PLC’s via LAN without Ethernet-CP
    Produkbild
    Your panel only has a LAN-socket as PLC-interface, no problem. Connect this socket with the S5-LAN++ and plug it directly on the PD-interface of the PLC. Then access to the variables and data of the PLC is already available.
    Supply voltage: 24V DC +/- 20%
    Power consumption: 2 watt
    Display: status-LED
    Handling/Configuration: reset-switch-key (factory setting)
    S5-LAN Manager
    Interfaces:
    to the PLC:
    RS232 TxD, RxD and GND
    to the PD/PC:
    10/100BaseTX RJ45-ethernet jack
    Operating system: Configuration and operation via virtual COM-interface: MS-Windows XP/2000/7/8/10/11/Server
    Operation via TCP/IP server: any operating system with a TCP/IP stack
    Operating temperature: 0 - 55°C
    Case: ABS-plastic case
    Dimensions: 42 x 15 x 65 mm
     
    Scope of delivery: S5-LAN++-module
    Power connector 2pins small
    All prices plus costs of delivery, shipping insurance and VAT.

    accessories:

    9359-LAN-UGR
    Device upgrade S5-LAN to S5-LAN++

    Hardware-update and firmware-upgrade from S5-LAN to S5-LAN++ Including checking the module
    Quickbestellung INFOMAIL
    by e-mail
    120,00 €
    plus VAT. and shipping


    9352-24
    Power connector 2pins small

    cable coupling by screw-connector (small)
    Quickbestellung INFOMAIL
    by e-mail
    4,00 €
    plus VAT. and shipping


    All prices plus costs of delivery, shipping insurance and VAT.

    9359-LAN-RS
    S5-LAN++ RS232-version

    Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
    Quickbestellung INFOMAIL
    by e-mail
    555,00 €
    plus VAT. and shipping




    maximum 3 articles
    9359-LAN
    S5-LAN++

    Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
    Quickbestellung INFOMAIL
    by e-mail
    452,00 €
    plus VAT. and shipping




    maximum 3 articles
    9359-PG-LAN
    S5-PG-LAN

    RS232-complement to S5-LAN++ (TTY/RS232)
    Quickbestellung INFOMAIL
    by e-mail
    924,00 €
    plus VAT. and shipping




    maximum 3 articles
    9359-LAN-RS
    S5-LAN++ RS232-version

    Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
    Quickbestellung INFOMAIL
    by e-mail
    555,00 €
    plus VAT. and shipping




    maximum 3 articles
    9359-RK-RS
    S5-3964R-LAN RS232-version

    Communication with 3964/9364R-client with S7-TCPIP inclusive adapter cable (15pin female <=> 9pin male)
    Quickbestellung INFOMAIL
    by e-mail
    971,00 €
    plus VAT. and shipping




    maximum 3 articles
    9359-RK
    S5-3964R-LAN

    Communication with 3964/9364R-client with S7-TCPIP Cable-adapter optional
    Quickbestellung INFOMAIL
    by e-mail
    866,00 €
    plus VAT. and shipping




    maximum 3 articles
    9359-ASCII
    S5-ASCII-LAN

    sends ASCII-data via Industrial Ethernet
    Quickbestellung INFOMAIL
    by e-mail
    567,00 €
    plus VAT. and shipping




    maximum 3 articles
    9359-H1-PG-LAN
    S5-H1-PG-LAN

    Supports Step5 SoftNet-communication direct to S5-PLCs
    Quickbestellung INFOMAIL
    by e-mail
    693,00 €
    plus VAT. and shipping




    maximum 3 articles
    9359-LAN-PATH
    S5-LAN with path-selection promotion

    Promotes the path-selection of the Step5-software
    Quickbestellung INFOMAIL
    by e-mail
    2185,00 €
    plus VAT. and shipping




    maximum 3 articles

    All prices plus costs of delivery, shipping insurance and VAT.

    9359-RK-RS
    S5-3964R-LAN RS232-version

    Communication with 3964/9364R-client with S7-TCPIP inclusive adapter cable (15pin female <=> 9pin male)
    Quickbestellung INFOMAIL
    by e-mail
    971,00 €
    plus VAT. and shipping


    9359-LAN
    S5-LAN++

    Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
    Quickbestellung INFOMAIL
    by e-mail
    452,00 €
    plus VAT. and shipping


    0,00 €
    plus VAT. and shipping

    9391-UH
    Mounting of universal DIN-rail-holder

    of the relevant product, inclusive holder
    Quickbestellung INFOMAIL
    by e-mail
    63,00 €
    plus VAT. and shipping


    9352-ALF-ANT
    Magnetic base antenna for indoor use

    for ALF, ALF-UA- S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m
    Quickbestellung INFOMAIL
    by e-mail
    83,00 €
    plus VAT. and shipping


    9352-S7-USB
    S7-USB connector for Siemens S7 Controller

    universal USB-module on PPI/MPI/Profibus 9,6 KBit/s up to 12MBit/s
    Quickbestellung INFOMAIL
    by e-mail
    317,00 €
    plus VAT. and shipping