S5-LAN++
![](images/Homepage-Bilder/S5-LANModul.png)
![](images/Homepage-Bilder/S5-LANModul.png)
![](images/katalog/S5-LAN.jpg)
![](images/katalog/S5LAN-Kommunikation.jpg)
![](images/katalog/S5-WLAN.png)
![](images/katalog/S5-LAN-WLAN.png)
![](images/katalog/S5LAN-RFC1006.png)
![](images/katalog/S5LAN-Patch.png)
![](images/katalog/S5LAN-S7TCPIP.png)
![](images/katalog/S5LAN-Internet.png)
![](images/katalog/S5LAN-SPSKopplung.png)
![](images/katalog/3964RLAN-Kommunikation.png)
![](images/katalog/S5-H1-PG-LAN.png)
![](images/katalog/3964RLAN-Strecke.png)
![](images/katalog/DB-S5-FTP.png)
![](images/katalog/DB-S5-FTP-IO.png)
![](images/katalog/DB-S5-SD.png)
![](images/katalog/DB-S5-SD-IO.png)
![](images/katalog/DB-S5-USB.png)
![](images/katalog/DB-S5-USB-IO.png)
![](images/katalog/S5-LAN-S5-LAN.png)
![](images/katalog/S7-LAN-S5-LAN.png)
![](images/katalog/S5-LAN-PN.png)
![](images/katalog/FW-s5lan.png)
![](images/katalog/TRT-s5lan.png)
![](images/katalog/S5-LAN-VPN.png)
Network-connection for the S5-PLC +++ Network to PG-interface +++ Of developer and manufacturer +++ Remotemaintenance via Internet +++ S5 (CP-343-1 compatible)
Industrial Ethernet <> S5 PD-interface (TTY)
Including Gateway Plus and S7-TCP / IP
functions
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET-function.
By plugging the module onto the PG-interface of an S5-PLC, this connection becomes a universally usable connection, a "multi-connection". Multiple and parallel communications at the same time, such as WinCC, PUT/GET from S7-PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step5 or PG2000.
Advantages:
- Simple and fast networking
- Multiplexer for all protocols
- Integration as S7-300 (CP 343-1)
more...
ARTNR: 9359-LAN
S5-LAN++
EAN number: | 4260363240024 | |
HS-code: | 85423190 | |
Weight: | 0.05 kg |
S5
device type | ||||||
S5-90U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-95U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-100U |
x
|
+ext. 24V(3)
|
+ext. 24V
|
x
|
x
|
x
|
S5-115U |
at 944 + 9359-8
|
at 944 + 9359-8 + ext. 24V (4)
|
x
|
x
|
x
|
x
|
S5-135U |
at 928B + 9359-8
|
at 928B + 9359-8 +ext. 24V (6)
|
x
|
x
|
x
|
x
|
S5-155U |
x
|
x
|
x
|
x
|
x
|
x
|
S5-AG110S |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG130W/B |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG150A/K/S/U |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
CP-143 |
x
|
x
|
x
|
|||
CP-521 |
+CP521 adapter
|
+CP521 adapter(1)
|
||||
CP-523 |
+CP523 adapter
|
+CP523 adapter(1)
|
||||
CP-525 |
+9359-5(1)
|
|||||
CP-526 |
x
|
x
|
x
|
|||
CP-527 |
x
|
x
|
x
|
|||
CP-528 |
x
|
x
|
x
|
|||
CP-544 |
x (7)
|
x (7)
|
x (7)
|
|||
CP-5430 |
x
|
x
|
x
|
|||
CP-5431 |
x
|
|||||
IP-246 |
x
|
x
|
x
|
|||
IP-247 |
x
|
x
|
x
|
|||
IP-252 |
x
|
x
|
x
|
|||
IP-266 |
x
|
+9359-4(1)
|
||||
WF-470 |
+9359-5-WF470 + 9359-4(1)
|
|||||
SIN-805 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-820 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-840 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-850 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-880 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
Connection on PC |
RS232-port
|
Ethernet RJ45
|
Ethernet RJ45 / WLAN/WIFI
|
USB-port type A
|
RS232-port
|
RS232-port
|
max. prolongation: | 300m (UNI-extension) | 300m (S5-LAN-extension) +ext. 24V | 100m (PG-USB-extension) | 300m (UNI-extension) | ||
(1) ISO adapter can not be used because the required supply voltage on the PG interface of the module is not present. (2) At the CPU 6ES5 102-8MA02 Release 3 is a PG-ISO-Adapter or Netz-Adapter additional required. (3) With S5-LAN++ from HW V2.3 [2010] the "Netz-Adapter" is no more needed, this version has included current-sources. (4) With S5-LAN++ from HW V2.3 [2010] no accessories are needed, this version has included current-sources. (5) With S5-LAN++ from HW V2.3 [2010] the Sinum-Adapter 9359-6-USB is needed. (6) Only for CPU928B with PG-ISO-Adapter and ext. 24V DC, unless there is an S5-LAN++ from HW V2.3 [2010] used. (7) CP544 has bolts at the programming-interface. The products do not fit 100% on this interface. (8) With S5-BRIDGE the Sinum-Adapter 9359-6-USB is needed. |
Remote maintenance
![]() |
||||||||
secured modem-protocol |
✓
|
✓
|
✓
|
|||||
additional software needed |
Siemens TS -Software
|
Siemens TS -Software
|
VPN-Client
|
VPN-Client
|
||||
Providing WinTELEPROF-software |
✓
|
✓
|
✓
|
|||||
modem |
analogue/ISDN
|
analogue
|
opt. via PCMCIA
|
analogue/GSM
|
analogue/ISDN/GSM
|
internet-connection
|
internet-connection
|
internet-connection
|
modem for world wide use |
✓
|
✓
|
✓
|
✓
|
✓
|
|||
interfaces | ||||||||
MPI/Profibus |
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
||||
RS232 |
2x
|
2x
|
2x
|
1x
|
1x
|
|||
TTY |
2x
|
2x
|
2x
|
1x
|
||||
PCMCIA |
2x (optionally)
|
1x
|
1x
|
|||||
Ethernet |
10/100BaseTx
|
1x
|
1x
|
5x
|
||||
USB |
2x
|
1x
|
||||||
LCD-display |
✓
|
✓
|
✓
|
✓
|
instead 10 LEDs
|
instead status-LED
|
instead webserver
|
instead webserver
|
supported PLC-protocols * | ||||||||
S7 |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
||
S5 |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
||||
Pilz PSS |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
Allen-Bradley |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
AEG |
✓ (optional)
|
✓ (optional)
|
||||||
Bosch |
✓ (optional)
|
✓ (optional)
|
||||||
Telemecanique |
✓ (optional)
|
✓ (optional)
|
||||||
GE-Fanuc |
✓ (optional)
|
✓ (optional)
|
||||||
Klöckner-Moeller |
✓ (optional)
|
✓ (optional)
|
||||||
Mitsubishi |
✓ (optional)
|
✓ (optional)
|
||||||
SMS-sending/Pager(S5/S7) |
✓
|
✓
|
✓
|
✓ (no pager)
|
only for analogue / ISDN
|
|||
HMI-messaging module(S5/S7) |
✓
|
✓
|
||||||
SMS-receive with GSM |
✓
|
|||||||
DTMF with analogue |
✓
|
|||||||
e-mail-dispatch |
✓
|
✓
|
✓
|
|||||
FAX-dispatch(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
only for analogue / ISDN
|
||||
PLC-data coupling(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
✓
|
|||
ASCII-transfer from S5/S7 |
✓
|
✓ (optional)
|
✓ (optional)
|
only with ASCII-LAN
|
||||
internet-coupling |
✓
|
|||||||
Usage as dial-up-router |
✓
|
✓
|
||||||
power supply |
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
dimensions w x h x d (in mm) |
High: 67 x 280 x 170
FLAT: 300 x 175 x 70 |
300 x 175 x 66
|
235 x 162 x 37
|
90 x 162 x 54
|
40 x 125 x 115
|
42 x 15 x 65
|
65 x 43 x 17
|
154 x 92 x 28
|
* other PLC types on request |
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET-function.
By plugging the module onto the PG-interface of an S5-PLC, this connection becomes a universally usable connection, a "multi-connection". Multiple and parallel communications at the same time, such as WinCC, PUT/GET from S7-PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step5 or PG2000.
Advantages:
- Simple and fast networking
- Multiplexer for all protocols
- Integration as S7-300 (CP 343-1)
- Access to S5-data via S7-TCP/IP with PUT/GET
- Qualified support
- Comprehensive documentation
- S5-LAN++ direkt auf PG-Schnittstelle der S5
- S5-LAN++ über Multiplexer PG-MUX-II auf PG-Schnittstelle der S5
- S5-LAN++-Derivat für 3964R über Adapterkabel an CP524/525
- an PC direkt verbunden mit Patch-Kabel
- an PC direkt verbunden mit Cross-Kabel
- an PC über Hub/Switch
- fastest installation to the network of every SIMATIC - S5
- no complicated installation, simply plug on 15pin PD-interface and communicate
- no change in the software in the PLC
- SIMATIC S5 protocols
AS511, RK 512, SINEC-H1 and ISO-on-TCP (RFC 1006) - supported Controls
S5-90U, S5-95U, S5-100U, S5-115U, S5-135U, S5-150U (via intermediate adapter), S5-155U, Sinumerik 810/880 (via intermediate adapter) and COMCON 110 from Berthel - supported data areas
inputs, outputs, flags (also S5 s-flag), datea blocks (also S5 dx-block), timer and counter - easiest configuration with Windows tool (S5 LAN manager)
- at the same time two PG-, four OP/Visualization- and two RFC1006-channel (ISO on TCP)
- speak to S5 as a S7
- integrated multiplexer, parallel use of all protocols
Programming and visualizing simultaneously without any special configuration - external 24V supply optional, otherwise automatically directly from S5-PG socket (from S5-115U)
- supported platforms
S7-TCPIP RFC1006-communication platform independent, otherwise configuration tools/virtual com port for Windows (any) 32/64bit
- Timely communication with the S5-PLC through integrated firmware
- PUT/GET via S7-TCP/IP-access to S5-data (I/O/M/DB/DX/Z/T/S-flags)
- S7-S5-coupling with PUT/GET S7-300/400/1200/1500
- Coupling with WinCC, OPC-server and S7-TCP/IP-software-driver such as IP-S7-LINK (S7 compatible)
- S5 TCP/IP Layer 4
- Access from applications/devices via FETCH/WRITE-protocol to the connected S5-PLC
- S5-LAN-Link (open protocol)
- Compatible with S5-VIPA-TCP/IP
- RFC-1006 connection => pure ISOonTCP (handling blocks scope of delivery)
- RK 512 and TCP/IP H1-ISO-On-TCP RFC1006 (CP1430 TCP) supported
- with WinCC Flexible / TIA (e.g. MP377, TP177B) via S7-TCP/IP to the Simatic S5 (CP-343-1 compatible)
- data exchange between S5 - S5 and S5 - S7 via TCP/IP
- ideal for process visualization
- programming with STEP 5 via Ethernet
- DHCP / Auto-IP supported
- variants: 3964R-LAN, ASCII-LAN, PG-LAN, as RS232-version and for the MUX757
- driver-DLL for Windows available, EXCEL and WORD can read/write S5-data
- including a free Classic OPC-DA-server license "OPC-Manager lite" [limited to 100 items]
- examples and demo-version of communication driver as download available
Applications:
- Connection to SCADA / data-acquisition systems
- Data exchange with S7-PLC (300/400/1200/1500)
- S7-panel as replacement for defective, no more deliverable S5-panel
- remote programming (also via the Internet))
- control central all controls in the plant
Supported S5 protocols / connection-paths:
- AS511 via virtual COM-port PLCVCom
- S7-TCP/IP with PUT/GET-function
- ISO-on-TCP (RFC 1006)
- TCP/IP with H1/ISO-on-TCP
- TCP/IP with RK 512 (3964 and 3864R)
Addressing of the S5-data via S7-TCP-protocol:
The implementation of the data in S5 is largely identical to the S7 and works completely autonomously. F/I/O/T/C are addressed read/write identically.
Even a necessary conversion of the data-types such as S5-float (in KG-format) to S7-float (according to IEEE-754) takes place automatically in both directions.
The address must be converted for DB/DX and S-flags.
For the data blocks, this is usually a factor of 2. You can find examples for DL and DR in the data word in the table:
Simatic S5 | Simatic S7 | Format |
FB11 | FB11 | BYTE |
FW20 | FW20 | WORD |
DB10 DW 9 | DB10.DBW18 | WORD |
DB10 DW60 | DB10.DBW120 | WORD |
DB10 DL3 | DB10.DBB6 | BYTE |
DB10 DR3 | DB10.DBB7 | WORD |
DB10 DD 25 | DB10.DBD50 | DWORD |
DB10 DD 35 | DB10.DBD70 | Real |
Addressing S5 DX-Blocks with S7-TCP/IP
DX Block nr | mapped to S7-DB nr |
DX 1 | DB 257 |
DX 2 | DB 258 |
DX 100 | DB 356 |
Addressiing S5 S-Flag over S7 TCP/IP
Since the S7 does not recognize the S-flags, the S-flags are mapped as data block DB 1000. That means reading and writing on DB 1000 means reading and writing the S-flags
The following applies in the table: x = S-flag number, y = bit number
S-Flag | mapped to S7-DB nr |
S x.y | DB1000.DBX x.y |
SY x | DB1000.DBB x |
SW x | DB1000.DBW x |
SD x | DB1000.DBD x |
S5 goes INDUSTRIE 4.0 (only in german) (Mouse click for enlargement)
![](data/beschreibung/../../images/newsletter/s5-lan-iot-text.png)
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/S5-LAN.jpg)
Replace defective panels in your "old" S5-systems with current and available S7-panels
To do this, simply insert a placeholder PLC (e.g. 315-2-PN / DP) in the WinCC-project, the IP-address
of the PLC corresponds to the IP-address of the S5-LAN++-module. You can then visualize the data as usual.
At the same time, the PLC can also be programmed/monitored via the network.
![Produkbild](images/showimage.php?prozent=65&path=../images/katalog/S5LAN-Kommunikation.jpg)
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/S5-WLAN.png)
Move wirelessly around the S5-PLC and communicate for example ONLINE in the status
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/S5-LAN-WLAN.png)
Connect each S7-TCP-IP panel to your S5.
Now also available via WLAN for mobile workstations.
PARALLEL several panels and even simultaneous PG connections possible.
Include hard-to-reach places in your ERP system.
![Produkbild](images/showimage.php?prozent=65&path=../images/katalog/S5LAN-RFC1006.png)
![Produkbild](images/showimage.php?prozent=65&path=../images/katalog/S5LAN-Patch.png)
![Produkbild](images/showimage.php?prozent=65&path=../images/katalog/S5LAN-S7TCPIP.png)
![Produkbild](images/showimage.php?prozent=65&path=../images/katalog/S5LAN-Internet.png)
![Produkbild](images/showimage.php?prozent=65&path=../images/katalog/S5LAN-SPSKopplung.png)
![Produkbild](images/showimage.php?prozent=65&path=../images/katalog/3964RLAN-Kommunikation.png)
![Produkbild](images/showimage.php?prozent=65&path=../images/katalog/S5-H1-PG-LAN.png)
With the S5-H1-PG-LAN you would be able to use the H1-path-selection over the S5-LAN++ and communicate with all PLCs in the H1-bus. You don´t have to connect serial to the CP, you can do this easy over your network.
![Produkbild](images/showimage.php?prozent=65&path=../images/katalog/3964RLAN-Strecke.png)
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/DB-S5-FTP.png)
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/DB-S5-FTP-IO.png)
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/DB-S5-SD.png)
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/DB-S5-SD-IO.png)
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/DB-S5-USB.png)
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/DB-S5-USB-IO.png)
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/S5-LAN-S5-LAN.png)
Coupling S5-controller with PD-port at S5-controller with PD-port via network
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/S7-LAN-S5-LAN.png)
Coupling S7-controller with MPI/Profibus at S5-control with PD-port via network
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/S5-LAN-PN.png)
Coupling S7-controller with PN-port at S5-controller with PD-port via network
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/FW-s5lan.png)
Remote-maintenance of a Siemens-S5-controller with S5-LAN++ on PD-port via secure VPN-tunnel and scalable firewall
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/TRT-s5lan.png)
Remote-maintenance of a Siemens-S5-controller with S5-LAN++ on PD-port via secure VPN-tunnel of the TeleRouter
![Produkbild](images/showimage.php?size=227.5&path=../images/katalog/S5-LAN-VPN.png)
Remote-maintenance of a Siemens-S5-controller with S5-LAN++ on PD-port over separate VPN-server
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2 watt |
Display: | status-LED |
Handling/Configuration: |
reset-switch-key (factory setting) S5-LAN Manager |
Interfaces: |
to the PLC:
TTY/20mA current loop (S5-LAN activ, S5-PLC passive)
to the PD/PC:
10/100BaseTX RJ45-ethernet jack (auto select) |
Operating system: |
Configuration and operation via virtual COM-interface: MS-Windows XP/2000/7/8/10/11/Server Operation via TCP/IP server: any operating system with a TCP/IP stack |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 42 x 15 x 65 mm |
Scope of delivery: |
S5-LAN++-module Power connector 2pins small |
accessories:
Device upgrade S5-LAN to S5-LAN++
Hardware-update and firmware-upgrade from S5-LAN to S5-LAN++ Including checking the module
![](images/Homepage-Bilder/S5-LAN-Upgrade.png)
plus VAT. and shipping
Read PLC-data from 942F-SPS via S5-LAN++
Project license Communicatio-DLL 32-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++
Project license Communicatio-DLL 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++
Project license Communicatio-DLL LINUX 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic.
Site / Branch / Standort License Communicatio-DLL 32-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic
Site / Branch / Standort License Communicatio-DLL 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic
Site / Branch / Standort License Communicatio-DLL LINUX 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic
Site / Branch / Standort License Communicatio-DLL ARM Windows 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic
Site / Branch / Standort License Communicatio-DLL ARM LINUX 64-bit Function/call similar to IPS7-Link-DLL
![](images/Homepage-Bilder/S5LAN-DLL.png)
plus VAT. and shipping
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
![](images/Homepage-Bilder/Patchkabel_Cat5_Cat5plus.png)
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
![](images/Homepage-Bilder/USB-Powerkabel.png)
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
PG-USB AG-150-adapter
for PG-USB-cable + S5-LAN++ (from HW2.3) to AG-150
AG-150-adapter
for PG-UNI + PG-UNI-II-cable + S5-LAN++ (up to HW2.2) with Netz-Adapter to AG-150
![](images/Homepage-Bilder/PG-USB_AG-150-Adapter.png)
SINUM-adapter
for PG-UNI + PG-UNI-II-cable + S5-LAN++ (up to HW2.2) to SINUMERIK
PG-USB SINUM-adapter
for PG-USB-cable + S5-LAN++ (from HW2.3) to SINUMERIK
![](images/Homepage-Bilder/SINUM-Adapter.png)
plus VAT. and shipping
CP-525-K-adapter
for PG-UNI + PG-UNI-II-cable <-> CP-525- communication
CP-525-K-adapter for PG-USB + S5-LAN++
PG-USB-cable and S5-LAN++ (at east HW V2.3) to CP-525-communication
![](images/Homepage-Bilder/CP-525-K-Adapter.png)
WF-470-adapter
for PG-UNI + PG-UNI-II-cable <-> WF470
PG-USB WF-470-adapter
for PG-USB-cable <-> WF470
![](images/Homepage-Bilder/WF-470-Adapter.png)
plus VAT. and shipping
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
![](images/Homepage-Bilder/S5-LANModul.png)
plus VAT. and shipping
S5-BRIDGE
ONLINE with S5PLC without cable +++ S5-adapter 90-155U/CPs/IPs +++ No WIFi-infrastructure +++ Integrated access-point +++ Configuration via WebAccess +++ S5 Bridge (TTY - LAN - WIFI)
![](images/Homepage-Bilder/S5-BRIDGE_neu.png)
plus VAT. and shipping
plus VAT. and shipping
S5-LAN++ RS232-version
Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
![](images/Homepage-Bilder/S5-LANModul.png)
plus VAT. and shipping
S5-3964R-LAN RS232-version
Communication with 3964/9364R-client with S7-TCPIP inclusive adapter cable (15pin female <=> 9pin male)
![](images/Homepage-Bilder/S5-LANModul.png)
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Internet
![](images/showimage.php?path=Homepage-Bilder/Tele-Router.png&size=150)
The simple and quick router solution for automation
![](images/showimage.php?path=Homepage-Bilder/S5TCPIP100.png&size=150)
Turbo ethernet for PLC-oldie Simatic S5
S5 over LAN
![](images/showimage.php?path=Homepage-Bilder/S5-BRIDGE_neu.png&size=150)
Simatic S5 ethernet gateway with Wifi for TTY
![](images/showimage.php?path=katalog/CONNECT_Uebersicht.png&size=150)
Remotesupport without configuration / Machine access without IT
Internet-coupling/communication
![](images/showimage.php?path=katalog/CONNECT_Uebersicht.png&size=150)
Remotesupport without configuration / Machine access without IT
![](images/showimage.php?path=Homepage-Bilder/S7LAN-V30.png&size=150)
smallest simatic S7 ethernet gateway with PD-socket, multifunctional, 1 adapter for all PPI, MPI and Profibus applications
with ext. 24V-connector
easy remote maintenance over internet
![](images/showimage.php?path=Homepage-Bilder/ALF-UA.png&size=150)
Industrial WLAN-Router +++ High-speed datarate 150 Mbit/s +++ Integrated firewall +++ Din-rail-mounting +++ Make your own WIFI
![](images/showimage.php?path=Homepage-Bilder/Tele-Router.png&size=150)
The simple and quick router solution for automation
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
![](images/Homepage-Bilder/S7LAN-V30.png)
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Automatic-mode
Main downloads
Versionstory
- Release-docu 3964R-LAN-firmware
- Release-docu ASCII-LAN-firmware
- Release-docu Multi-VCom
- Release-docu PLCVCom
- Release-docu S5-H1-PG-LAN-firmware
- Release-docu S5-LAN++-firmware
- Release-docu S5-LAN-Manager
- Release-docu S5-LAN-PATH-firmware
- Release-docu S5-Patch
- Release-docu S5-PG-LAN-firmware
- Release-docu S5-VCom