S5-BRIDGE
ONLINE with S5PLC without cable +++ S5-adapter 90-155U/CPs/IPs +++ No WIFi-infrastructure +++ Integrated access-point +++ Configuration via WebAccess +++ S5 Bridge (TTY - LAN - WIFI)
Operating as a client or access-point
Configuration via web-server
Supply: 24V DC
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
more...
ARTNR: 9201
EtherSens Basic
EAN number: | 4260363244282 | |
HS-code: | 85423190 | |
Weight: | 0.3 kg |
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
Quite simply directly for all Siemens Step5, PG-2000, any other S5 package and WinCC projects.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-firmware-file
Configuration-tool / update-tool for Windows XP, 7/VISTA/8/10/11 32/64 bit:
download-S5-LAN-Manager inclusive PLC-firmware-file
Highlights:
- Parallel operation of several connections e.g. Remote maintenance, programming, visualization and much more is possible.
- Replacement for e.g. expensive CP
- Coupling to each ERP system e.g. about OPC logs.
- No PLC knowledge required
- Active module, thanks to its own power sources no influence on the S5.
- Communication with Fetch/Write
- Ideal for process visualization
- Open TCP/IP protocol
- RK 512 and TCP/IP H1-ISO-On-TCP RFC1006 (CP1430 TCP) supported
- Available in the variants 3964R-LAN, ASCII-LAN, PG-LAN, and for MUX757.
- Move around the machine without restrictions during commissioning or maintenance!
- Work where problems are visible and comprehensible!
Application areas:
- Commissioning of machines directly on PLC interface.
- Connection of mobile devices to the fieldbus system.
- Universal coupling of all PLC machines, no matter which interfaces are available!
- WIFI programming adapter for service applications, once parameterized, thanks to flash memory without data loss, independent of power failures.
- PUT/GET of S7-1500/1200/300/400 (PN-CPU or with Ethernet-CP), also ACTIVE , with specified and unspecified connection possible.
- VPN remote maintenance possible, to maintain the PLC via the Internet.
- Coupling with DB-Transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5-Gateway.
- any TCP device writes/reads DB`s in the S5 control.
Configuration:
- Easiest configuration through intuitive operation!
The S5 bridge is designed for fast commissioning .
After the module has been plugged into the plc, only assigne the IP address is via the S5-LAN Manager. After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
- Plug in the module, activate WLAN on the laptop, connect with Bridge-WLAN -> DONE
STEP-7 / TIA / WIN-CC / MICROWIN:
Each network device that speaks RFC1006 S7-TCP/IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP/IP and expands every MPI bus/PROFIBUS by a S5 network gateway.
It does not matter which control types, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- No expensive CP's needed for PLC-couplings.
- Supports remote maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S5 bridge can be used directly as a WLAN gateway for PLCs among each other device. Programming and visualizing S5 PLCs via WLAN is no longer a problem. Thanks to ext. Power supply usable on all controllers.
The S5 SPS Bridge with all functions is the perfect PLC network adapter for each application.
S5-Bridge is a reliable and handy S5-WIFI network adapter for every technician .
The compact design and the power supply directly from the CPU,
enable a PLC ** to be connected to the Ethernet in less than 5 minutes.
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PN-port to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on SD card
Via digital input triggered DB-backup/-restore without additional PC via PN-port to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via PN-port to USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PN-port to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on SD-card
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to USB-stick
Send directly from your PLC news, statuses, alarms as SMS or email.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2 watt |
Display: |
WEB-Browser 1 status LED bicolor |
Handling/Configuration: | WEB-Browser |
Interfaces: |
Slot for microSD Antenna-connector SMA(f) (2.4 GHz IEEE 802.11b/g) 10/100BaseTX RJ45-ethernet-plug Button for factory settings |
Overvoltage category: | CAT IV |
Insulation value network <=> mains voltage: |
1,5 KV |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case V0 |
Dimensions: | 100 x 112 x 45 mm |
Scope of delivery: |
EtherSens Basic WIFI-stub-antenna |
extensions:
Extension Analog-IO V1.0
Extension-board for EtherSens-devices 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Extension with ext. galv. separated I2C 5V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 5V Power consumption: 2W
plus VAT. and shipping
Extension LTE-modem
LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
plus VAT. and shipping
Extension Energy-IO
Extension-board for EtherSens-devices Energy-analysis (EN 50470-1 EN 50470-3) L1, L2, L3, N realtime analysis Up to 8000 measurements / second Hz / cos phi / power-factor Energy consumption kWh For Rogwski-coils up to 0,5V
plus VAT. and shipping
U-I-box for EtherSens
max. 1000V DC / 40A 24V DC supply 20cm power-cable 4mm2 with Amphenol-plug I2C-connection 1m
plus VAT. and shipping
Sun-light-sensor for EtherSens
max. 220k Lux (switchable ranges) 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 312 for EtherSens
Measuring range: ±1.5g / ±3g / ±6g / ±12g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 313 for EtherSens
Measuring range: ±0.5g / ±1g / ±2g / ±4g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Temp./humidity/air-pressure for EtherSens
Measuring range: Temperature: -40 ...+85°C Humidity: 0...100% relative Feuchte Pressure: 300...1100 hPa 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Segment-display for EtherSens
4 Digit 14 segment-display WHITE 0,56" high in wall-mounting case 5V DC supply (from I2C-interfaceport) I2C-connection
plus VAT. and shipping
Extension with ext. galv. separated I2C 3.3V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W
plus VAT. and shipping
Extension RS485-IO
Extensionboard for EtherSens-devices V1.0 for RS485 Power consumption: 2W
plus VAT. and shipping
Extension TTY-IO
Extensionboard for EtherSens-devices V1.0 for TTY (incl. 2x current-sources) Power consumption: 2W
plus VAT. and shipping
Extension Digital-IO
Extension-board for EtherSens-devices 12 x digital IN or OUT 24VDC 400mA free config with software Power consumption: 4W
plus VAT. and shipping
Extension 24V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 24V DC 4 x relay-OUT 230VAC/16A Power consumption: 4W
plus VAT. and shipping
Extension 230V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 230V AC 4 x relay-OUT 230VAC/16A Power consumption: 2,5W
plus VAT. and shipping
Power-supply-rack-unit 230V
Input voltage: 100 - 240VAC 50-60Hz Output voltage: 24V DC Power: 4W
plus VAT. and shipping
Extension Analog-IO V1.1
Extension-board for EtherSens-devices 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Extension RS422-IO
Extensionboard for EtherSens-devices V1.0 for RS422 (4-wire) Power consumption: 2W
plus VAT. and shipping
Extension RS232-IO
Extensionboard for EtherSens-devices V1.0 for RS232 (RxD, TxD) Power consumption: 2W
plus VAT. and shipping
Extension USB-port
USB-port for EtherSens-devices (data storage) Extension for: - DB-backup/restoure-function - CSV-recording Maximum current: 200mA for 5V DC
plus VAT. and shipping
accessories:
plus VAT. and shipping
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
EtherSens
Collect energy data +++ Log energy data +++ PLC fault message dispatch +++ PLC data logging/saving +++ Implement control tasks +++ Configuration via webinterface
Capture Dig/Analog-IO +++ Log Dig/Analog-IO +++ PLC fault message-dispatch +++ PLC-data logging/saving +++ implement control-tasks +++ Datalogger with web-server +++ Digital/analogue onboard-IO
Capture of gas-values +++ Monitor of gas-values +++ PLC-fault messaging +++ PLC-data logging/saving +++ Convert control tasks
load studies +++ energy checks +++ collect energy data +++ Log energy data +++ PLC fault message dispatch +++ PLC-data logging/saving +++ implement control-tasks +++ EN50470-1 / EN50470-3
Error messaging
Long distance report- and information systems in 2G-net
Long distance report- and information systems in 3G-net
plus VAT. and shipping
plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping
Extension LTE-modem
LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
plus VAT. and shipping
Extension with ext. galv. separated I2C 3.3V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W