ONLINE with S5PLC without cable +++ S5-adapter 90-155U/CPs/IPs +++ No WIFi-infrastructure +++ Integrated access-point +++ Configuration via WebAccess +++ S5 Bridge (TTY - LAN - WIFI)
PPI/MPI/Profibus up to 12Mbit/s
Also available as a set for universal use: S5/S7-BRIDGE-WIFI-SetsProduct Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
more...
variants:
ARTNR: 9352
MPI-II - Interfacecable 3m
359,00 € plus VAT. and shipping
ARTNR: 9352
MPI-II - Interfacecable 3m
EAN number: | 4260363240932 | |
HS-code: | 85444290 | |
Weight: | 0.3 kg |
S7
PPI-Bus | |||||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||||
USB | |||||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||||
LAN | |||||||||
10/100BaseTx |
x(7)
|
x
|
x
|
x
|
x
|
||||
WIFI | |||||||||
2.4 GHz |
x
|
||||||||
TeleService operation | |||||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||||
baud rates at TS-operation directly at the PC | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||||
baud rates at TS-operation directly with a modem | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x
|
x
|
|||||||
115.2 KBit/s |
x
|
x
|
|||||||
HMI | |||||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||||
PLCVCOM |
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
RFC1006 |
8
|
8
|
32
|
32
|
32
|
||||
AG connections (maximum) | |||||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||||
integrated PLC-firewall |
|
|
x
|
x
|
x
|
||||
display diagnostic-buffer in the webbrowser |
|
|
x
|
x
|
x
|
||||
webserver for configuration |
x
|
x
|
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
x
|
x
|
||||
galvanic separation | |||||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
1,5KV
|
1,5KV
|
mounting | |||||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||||
upgrading with | |||||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||||
supports | |||||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win11 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1 (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3 (3) only serial communication (4) Siemens Step7 V5.2 and higher dont run with this operationing system (5) USB-communication is only possible with the special driver for Win NT (6) USB 2.0 is backward compatible to 1.1 (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation (8) only in combination with the MPI-Speed-driver („continously-active“) (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional) (11) only in the mode: MultiMaster-Mode (12) up to a maximum baud rate of 187.5 KBit/s (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port. (14) with the use of the TS-adapter / item number: 9350.TS (15) Update directly with PC and TIC-driver (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens (19) only at PPI-communication possible (20) Only with TIC-driver (21) with integrated webserver possible (22) No support of Siemens Step7-software possible (23) Only with USB and with TIC-driver |
Also available as a set for universal use: S5/S7-BRIDGE-WIFI-Sets
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
Quite simply directly for all Siemens Step5, PG-2000, any other S5 package and WinCC projects.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-firmware-file
Configuration-tool / update-tool for Windows XP, 7/VISTA/8/10/11 32/64 bit:
download-S5-LAN-Manager inclusive PLC-firmware-file
Highlights:
- Move around the machine without restrictions during commissioning or maintenance!
Application areas:
- Commissioning of machines directly on PLC interface.
- Connection of mobile devices to the fieldbus system.
- Universal coupling of all PLC machines, no matter which interfaces are available!
- WIFI programming adapter for service applications, once parameterized, thanks to flash memory without data loss, independent of power failures.
- PUT/GET of S7-1500/1200/300/400 (PN-CPU or with Ethernet-CP), also ACTIVE , with specified and unspecified connection possible.
- VPN remote maintenance possible, to maintain the PLC via the Internet.
- Coupling with DB-Transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5-Gateway.
- any TCP device writes/reads DB`s in the S5 control.
Configuration:
- Easiest configuration through intuitive operation!
The S5 bridge is designed for fast commissioning .
After the module has been plugged into the plc, only assigne the IP address is via the S5-LAN Manager. After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
- Plug in the module, activate WLAN on the laptop, connect with Bridge-WLAN -> DONE
STEP-7 / TIA / WIN-CC / MICROWIN:
Each network device that speaks RFC1006 S7-TCP/IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP/IP and expands every MPI bus/PROFIBUS by a S5 network gateway.
It does not matter which control types, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- No expensive CP's needed for PLC-couplings.
- Supports remote maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S5 bridge can be used directly as a WLAN gateway for PLCs among each other device. Programming and visualizing S5 PLCs via WLAN is no longer a problem. Thanks to ext. Power supply usable on all controllers.
The S5 SPS Bridge with all functions is the perfect PLC network adapter for each application.
S5-Bridge is a reliable and handy S5-WIFI network adapter for every technician .
The compact design and the power supply directly from the CPU,
enable a PLC ** to be connected to the Ethernet in less than 5 minutes.
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
Quite simply directly for all Siemens Step5, PG-2000, any other S5 package and WinCC projects.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-firmware-file
Configuration-tool / update-tool for Windows XP, 7/VISTA/8/10/11 32/64 bit:
download-S5-LAN-Manager inclusive PLC-firmware-file
Highlights:
- Parallel operation of several connections e.g. Remote maintenance, programming, visualization and much more is possible.
- Replacement for e.g. expensive CP
- Coupling to each ERP system e.g. about OPC logs.
- No PLC knowledge required
- Active module, thanks to its own power sources no influence on the S5.
- Communication with Fetch/Write
- Ideal for process visualization
- Open TCP/IP protocol
- RK 512 and TCP/IP H1-ISO-On-TCP RFC1006 (CP1430 TCP) supported
- Available in the variants 3964R-LAN, ASCII-LAN, PG-LAN, and for MUX757.
- Move around the machine without restrictions during commissioning or maintenance!
- Work where problems are visible and comprehensible!
Application areas:
- Commissioning of machines directly on PLC interface.
- Connection of mobile devices to the fieldbus system.
- Universal coupling of all PLC machines, no matter which interfaces are available!
- WIFI programming adapter for service applications, once parameterized, thanks to flash memory without data loss, independent of power failures.
- PUT/GET of S7-1500/1200/300/400 (PN-CPU or with Ethernet-CP), also ACTIVE , with specified and unspecified connection possible.
- VPN remote maintenance possible, to maintain the PLC via the Internet.
- Coupling with DB-Transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5-Gateway.
- any TCP device writes/reads DB`s in the S5 control.
Configuration:
- Easiest configuration through intuitive operation!
The S5 bridge is designed for fast commissioning .
After the module has been plugged into the plc, only assigne the IP address is via the S5-LAN Manager. After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
- Plug in the module, activate WLAN on the laptop, connect with Bridge-WLAN -> DONE
STEP-7 / TIA / WIN-CC / MICROWIN:
Each network device that speaks RFC1006 S7-TCP/IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP/IP and expands every MPI bus/PROFIBUS by a S5 network gateway.
It does not matter which control types, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- No expensive CP's needed for PLC-couplings.
- Supports remote maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S5 bridge can be used directly as a WLAN gateway for PLCs among each other device. Programming and visualizing S5 PLCs via WLAN is no longer a problem. Thanks to ext. Power supply usable on all controllers.
The S5 SPS Bridge with all functions is the perfect PLC network adapter for each application.
S5-Bridge is a reliable and handy S5-WIFI network adapter for every technician .
The compact design and the power supply directly from the CPU,
enable a PLC ** to be connected to the Ethernet in less than 5 minutes.
Programming S7-PLC/-modules via RS232/USB
PLC-programming/-communication from the PC "serial" or via "USB" from S7-200/300/400 or modules such as Sinamix, Sinumerik, MicroMaster, drives, converters.
PPI up to 187.5 Kbit (PPI + PPI advanced), MPI/Profibus up to 12 Mbit. Compatible with the Siemens driver "PC-adapter", communication only with 64-bit operating-systems via USB and TIC-driver (limitation of serial communication from Siemens to 32-bit operating-systems).
PPI up to 187.5 Kbit (PPI + PPI advanced), MPI/Profibus up to 12 Mbit. Compatible with the Siemens driver "PC-adapter", communication only with 64-bit operating-systems via USB and TIC-driver (limitation of serial communication from Siemens to 32-bit operating-systems).
Remote maintenance with TS-software without original TS-adaptor
You have to reach urgend your PLC via remote maintenance and have no TS-adaptor in your company? No problem, configure with the MPI-Kabelmanager your S7-interface-cable MPI-II-Kabel the mode "TS"
for "remote maintenance", connect this cable with the TS-Adapter (article number 9350-TS) with a standard modem and send it all to your client. Now you will be able to start the connection with
your TS-sofware and solve the problem. And this all without buying a original TS-adapter.
Visualisation of your S7-PLC via COM-Port
Your panel provides a serial port and no MPI/Profibus for connecting a S7-PLC. Connect the MPI-II-cable with it and you’re Online with your panel.
Coupling of S5-PLC with S7-PLC via PD-interfaces
S5 in the machine-park, conversion to S7 not profitable, central-control still requires production-data, who does not know this problem.
With "S5anMPI" you connect the S5-PLC with a standard interface-cable with the MPI/PROFIBUS of a S7-PLC. Loading handling-blocks in both PLCs, communication integrated and "S5anMPI" exchanges DB-content on request of the respective PLC. Configuration in the "S5anMPI" which PLC is active, also both PLCs active is possible.
Data-exchange without much effort and the S5-PLC continues in the S7-combination as usual and does not have to be replaced.
With "S5anMPI" you connect the S5-PLC with a standard interface-cable with the MPI/PROFIBUS of a S7-PLC. Loading handling-blocks in both PLCs, communication integrated and "S5anMPI" exchanges DB-content on request of the respective PLC. Configuration in the "S5anMPI" which PLC is active, also both PLCs active is possible.
Data-exchange without much effort and the S5-PLC continues in the S7-combination as usual and does not have to be replaced.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2,5 watt |
Display: | double lined LCD-display |
Handling/Configuration: |
Kabelmanager-Software keypad on the back |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
RS232: 9,6 KBd - 115,2 KBdUSB 1.1 for cable type A <-> A |
Galvanic separation: | 1000V PPI/MPI/Profibus to the PC |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 146 x 41 x 29 mm |
Scope of delivery: |
MPI-II-cable Power connector 2pins small |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
166,00 €
plus VAT. and shipping
plus VAT. and shipping
9391-USB
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
95,00 €
plus VAT. and shipping
plus VAT. and shipping
84,00 €
plus VAT. and shipping
plus VAT. and shipping
9391-HH
DIN-rail-holder for MPI/PPI
quick and easy assembling on the cap rail
DIN-rail-holder for MPI/PPI
quick and easy assembling on the cap rail
9350-WAND
Wall-mounting
for MPI/PPI + MPI-II + MPI-USB
Wall-mounting
for MPI/PPI + MPI-II + MPI-USB
4,00 €
plus VAT. and shipping
plus VAT. and shipping
48,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-104-2
MPI-PC104-card 2 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
MPI-PC104-card 2 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
9352-104
MPI-PC104-card 1 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
MPI-PC104-card 1 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
59,00 €
plus VAT. and shipping
plus VAT. and shipping
6,00 €
plus VAT. and shipping
plus VAT. and shipping
37,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
32,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-S7-BK
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
42,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
359,00 €
plus VAT. and shipping
plus VAT. and shipping
366,00 €
plus VAT. and shipping
plus VAT. and shipping
381,00 €
plus VAT. and shipping
plus VAT. and shipping
395,00 €
plus VAT. and shipping
plus VAT. and shipping
RS232
S5toMPI
Connects the S5-PLC with a S7-PLC
Connects the S5-PLC with a S7-PLC
MPI/PPI
S7-Interface cable for PPI, MPI, TS, HMI <=> RS232 applications
S7-Interface cable for PPI, MPI, TS, HMI <=> RS232 applications
All prices plus costs of delivery, shipping insurance and VAT.
559,00 €
plus VAT. and shipping
plus VAT. and shipping
32,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-LANCON
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
423,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
452,00 €
plus VAT. and shipping
plus VAT. and shipping
145,00 €
plus VAT. and shipping
plus VAT. and shipping