S5-BRIDGE
ONLINE with S5PLC without cable +++ S5-adapter 90-155U/CPs/IPs +++ No WIFi-infrastructure +++ Integrated access-point +++ Configuration via WebAccess +++ S5 Bridge (TTY - LAN - WIFI)
Communication with 3964/9364R-client with
S7-TCPIP
inclusive adapter cable
(15pin female <=> 9pin male)
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
more...
variants:
ARTNR: 9359-RK-RS
S5-3964R-LAN RS232-version
971,00 € plus VAT. and shipping
ARTNR: 9359-RK-RS
S5-3964R-LAN RS232-version
EAN number: | 4260363243889 | |
HS-code: | 85444290 | |
Weight: | 0.1 kg |
Also available as a set for universal use: S5/S7-BRIDGE-WIFI-Sets
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
Quite simply directly for all Siemens Step5, PG-2000, any other S5 package and WinCC projects.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-firmware-file
Configuration-tool / update-tool for Windows XP, 7/VISTA/8/10/11 32/64 bit:
download-S5-LAN-Manager inclusive PLC-firmware-file
Highlights:
- Move around the machine without restrictions during commissioning or maintenance!
Application areas:
- Commissioning of machines directly on PLC interface.
- Connection of mobile devices to the fieldbus system.
- Universal coupling of all PLC machines, no matter which interfaces are available!
- WIFI programming adapter for service applications, once parameterized, thanks to flash memory without data loss, independent of power failures.
- PUT/GET of S7-1500/1200/300/400 (PN-CPU or with Ethernet-CP), also ACTIVE , with specified and unspecified connection possible.
- VPN remote maintenance possible, to maintain the PLC via the Internet.
- Coupling with DB-Transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5-Gateway.
- any TCP device writes/reads DB`s in the S5 control.
Configuration:
- Easiest configuration through intuitive operation!
The S5 bridge is designed for fast commissioning .
After the module has been plugged into the plc, only assigne the IP address is via the S5-LAN Manager. After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
- Plug in the module, activate WLAN on the laptop, connect with Bridge-WLAN -> DONE
STEP-7 / TIA / WIN-CC / MICROWIN:
Each network device that speaks RFC1006 S7-TCP/IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP/IP and expands every MPI bus/PROFIBUS by a S5 network gateway.
It does not matter which control types, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- No expensive CP's needed for PLC-couplings.
- Supports remote maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S5 bridge can be used directly as a WLAN gateway for PLCs among each other device. Programming and visualizing S5 PLCs via WLAN is no longer a problem. Thanks to ext. Power supply usable on all controllers.
The S5 SPS Bridge with all functions is the perfect PLC network adapter for each application.
S5-Bridge is a reliable and handy S5-WIFI network adapter for every technician .
The compact design and the power supply directly from the CPU,
enable a PLC ** to be connected to the Ethernet in less than 5 minutes.
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
Quite simply directly for all Siemens Step5, PG-2000, any other S5 package and WinCC projects.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-firmware-file
Configuration-tool / update-tool for Windows XP, 7/VISTA/8/10/11 32/64 bit:
download-S5-LAN-Manager inclusive PLC-firmware-file
Highlights:
- Parallel operation of several connections e.g. Remote maintenance, programming, visualization and much more is possible.
- Replacement for e.g. expensive CP
- Coupling to each ERP system e.g. about OPC logs.
- No PLC knowledge required
- Active module, thanks to its own power sources no influence on the S5.
- Communication with Fetch/Write
- Ideal for process visualization
- Open TCP/IP protocol
- RK 512 and TCP/IP H1-ISO-On-TCP RFC1006 (CP1430 TCP) supported
- Available in the variants 3964R-LAN, ASCII-LAN, PG-LAN, and for MUX757.
- Move around the machine without restrictions during commissioning or maintenance!
- Work where problems are visible and comprehensible!
Application areas:
- Commissioning of machines directly on PLC interface.
- Connection of mobile devices to the fieldbus system.
- Universal coupling of all PLC machines, no matter which interfaces are available!
- WIFI programming adapter for service applications, once parameterized, thanks to flash memory without data loss, independent of power failures.
- PUT/GET of S7-1500/1200/300/400 (PN-CPU or with Ethernet-CP), also ACTIVE , with specified and unspecified connection possible.
- VPN remote maintenance possible, to maintain the PLC via the Internet.
- Coupling with DB-Transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5-Gateway.
- any TCP device writes/reads DB`s in the S5 control.
Configuration:
- Easiest configuration through intuitive operation!
The S5 bridge is designed for fast commissioning .
After the module has been plugged into the plc, only assigne the IP address is via the S5-LAN Manager. After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
- Plug in the module, activate WLAN on the laptop, connect with Bridge-WLAN -> DONE
STEP-7 / TIA / WIN-CC / MICROWIN:
Each network device that speaks RFC1006 S7-TCP/IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP/IP and expands every MPI bus/PROFIBUS by a S5 network gateway.
It does not matter which control types, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- No expensive CP's needed for PLC-couplings.
- Supports remote maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S5 bridge can be used directly as a WLAN gateway for PLCs among each other device. Programming and visualizing S5 PLCs via WLAN is no longer a problem. Thanks to ext. Power supply usable on all controllers.
The S5 SPS Bridge with all functions is the perfect PLC network adapter for each application.
S5-Bridge is a reliable and handy S5-WIFI network adapter for every technician .
The compact design and the power supply directly from the CPU,
enable a PLC ** to be connected to the Ethernet in less than 5 minutes.
Visualisation via 3964R-interface without using the protocol itself
Your visualisation-software does not support a 3964R-protocol, but you have to apply this package? No problem, connect the 3964R-LAN to your CP and activate the RFC1006-emulation in the module. Now
your software gets the data from the module via RFC1006, which in turn communicates with the assembly via 3964R.
Extension of a 3964R-line via LAN
There is a control with CP524 in your outstation and the communication partner of the CP has moved locally. Connecting path is a LAN-network. So each of both participants gets a 3964R-LAN and after
input of the partner’s IP-address a coupling via LAN will be configured.
PLC coupling (data exchange between PLC’s)
Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Therefore
no dedicated line is required, it’s sufficient when the stations connect via network (DSL-router).
With the S5-H1-PG-LAN you would be able to use the H1-path-selection over the S5-LAN++ and communicate with all PLCs in the H1-bus. You don´t have to connect serial to the CP, you can do this easy over your network.
Remote maintenance of your S5-PLC via LAN / Internet
You have access to a on-site network and your PLC has no LAN-connection? No problem, plug the S5-LAN on the PLC and you will have immediate access to the PLC from afar.
Programming of S5-PLC’s via LAN
You would like to respond to your S5-PLC via LAN, but not integrate an Ethernet-CP? No problem, plug the S5-LAN++ on the PD-interface and access via LAN.
Communication with Win98 – XP/Vista/7/8/10/11 via network to S5-PLC
You still have a PC with Win98 and a MS-DOS-based Step5-package and would like to go Online on your S5-PLC via LAN? No problem, the provided virtual Com-Port PLCVCom emulates a COM-port on your PC
with which you go Online. Even your MS-DOS-based Step5-software on this WIN98-PC can use this virtual Com-Port. With a patchtool for the Siemens Step5-software, which is provided as well, nothing
else stands in your way to communicate via LAN.
Watching of S5- PLC’s with panel for S7-PLC
Your panel only has a LAN-socket as PLC-interface and supports only S7-RFC1006, no problem. Connect this socket with the S5-LAN++ and plug it directly on the PD-interface of the PLC. The S5-LAN++
performs adverse your panel as a S7-PLC although you receive the data from the S5-PLC. Then access to the variables and data of the S5-PLC is already available.
Watching of S5-PLC’s via LAN without Ethernet-CP
Your panel only has a LAN-socket as PLC-interface, no problem. Connect this socket with the S5-LAN++ and plug it directly on the PD-interface of the PLC. Then access to the variables and data of
the PLC is already available.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2 watt |
Display: | status-LED |
Handling/Configuration: |
reset-switch-key (factory setting) S5-LAN Manager |
Interfaces: |
to the PLC:
RS232 TxD, RxD and GND
to the PD/PC:
10/100BaseTX RJ45-ethernet jack |
Operating system: |
Configuration and operation via virtual COM-interface: MS-Windows XP/2000/7/8/10/11/Server Operation via TCP/IP server: any operating system with a TCP/IP stack |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 42 x 15 x 65 mm |
Scope of delivery: |
S5-LAN++-module Power connector 2pins small |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
59,00 €
plus VAT. and shipping
plus VAT. and shipping
15,00 €
plus VAT. and shipping
plus VAT. and shipping
9636-TCPIP.02M
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
9636-CROSS
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
9636-TCPIP
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
4,00 €
plus VAT. and shipping
plus VAT. and shipping
9391-USB
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
95,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
9359-RK-RS
S5-3964R-LAN RS232-version
Communication with 3964/9364R-client with S7-TCPIP inclusive adapter cable (15pin female <=> 9pin male)
S5-3964R-LAN RS232-version
Communication with 3964/9364R-client with S7-TCPIP inclusive adapter cable (15pin female <=> 9pin male)
971,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
452,00 €
plus VAT. and shipping
plus VAT. and shipping
924,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN-RS
S5-LAN++ RS232-version
Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
S5-LAN++ RS232-version
Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
555,00 €
plus VAT. and shipping
plus VAT. and shipping
866,00 €
plus VAT. and shipping
plus VAT. and shipping
567,00 €
plus VAT. and shipping
plus VAT. and shipping
693,00 €
plus VAT. and shipping
plus VAT. and shipping
2185,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
9359-LAN-RS
S5-LAN++ RS232-version
Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
S5-LAN++ RS232-version
Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
555,00 €
plus VAT. and shipping
plus VAT. and shipping
59,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-LANCON
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
423,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-ALF-UA
ALF-UA high-speed WIFI-Router for Din-Rail-mounting Obsolete
Successor: CONNECT-Router for Din-Rail-mounting (Art.No: 9354-CONNECT-HS-ROUTER)
Industrial WIFI-Router for Unified Access Integrated USB-port Basic-plattform, functionality with software-options expandable One-click mounting
ALF-UA high-speed WIFI-Router for Din-Rail-mounting Obsolete
Successor: CONNECT-Router for Din-Rail-mounting (Art.No: 9354-CONNECT-HS-ROUTER)
Industrial WIFI-Router for Unified Access Integrated USB-port Basic-plattform, functionality with software-options expandable One-click mounting
0,00 €
plus VAT. and shipping
plus VAT. and shipping
Automatic-mode
Main downloads
Versionstory
- Release-docu 3964R-LAN-firmware
- Release-docu ASCII-LAN-firmware
- Release-docu Multi-VCom
- Release-docu PLCVCom
- Release-docu S5-H1-PG-LAN-firmware
- Release-docu S5-LAN++-firmware
- Release-docu S5-LAN-Manager
- Release-docu S5-LAN-PATH-firmware
- Release-docu S5-Patch
- Release-docu S5-PG-LAN-firmware
- Release-docu S5-VCom