S5-BRIDGE
ONLINE with S5PLC without cable +++ S5-adapter 90-155U/CPs/IPs +++ No WIFi-infrastructure +++ Integrated access-point +++ Configuration via WebAccess +++ S5 Bridge (TTY - LAN - WIFI)
OEM - Version (all accessories optional)
without PCMCIA-Slot for UMTS-/LAN-card
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
more...
variants:
ARTNR: 9372-OEM
TELE-PROFessional II worldwide use
1260,00 € plus VAT. and shipping
ARTNR: 9372-OEM
TELE-PROFessional II worldwide use
EAN number: | 4260363240062 | |
HS-code: | 85389099 | |
Weight: | 2.05 kg |
Remote maintenance
TELE LINK NETWORK
|
||||||||
secured modem-protocol |
✓
|
✓
|
✓
|
|||||
additional software needed |
Siemens TS -Software
|
Siemens TS -Software
|
VPN-Client
|
VPN-Client
|
||||
Providing WinTELEPROF-software |
✓
|
✓
|
✓
|
|||||
modem |
analogue/ISDN
|
analogue
|
opt. via PCMCIA
|
analogue/GSM
|
analogue/ISDN/GSM
|
internet-connection
|
internet-connection
|
internet-connection
|
modem for world wide use |
✓
|
✓
|
✓
|
✓
|
✓
|
|||
interfaces | ||||||||
MPI/Profibus |
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
||||
RS232 |
2x
|
2x
|
2x
|
1x
|
1x
|
|||
TTY |
2x
|
2x
|
2x
|
1x
|
||||
PCMCIA |
2x (optionally)
|
1x
|
1x
|
|||||
Ethernet |
10/100BaseTx
|
1x
|
1x
|
5x
|
||||
USB |
2x
|
1x
|
||||||
LCD-display |
✓
|
✓
|
✓
|
✓
|
instead 10 LEDs
|
instead status-LED
|
instead webserver
|
instead webserver
|
supported PLC-protocols * | ||||||||
S7 |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
||
S5 |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
||||
Pilz PSS |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
Allen-Bradley |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
AEG |
✓ (optional)
|
✓ (optional)
|
||||||
Bosch |
✓ (optional)
|
✓ (optional)
|
||||||
Telemecanique |
✓ (optional)
|
✓ (optional)
|
||||||
GE-Fanuc |
✓ (optional)
|
✓ (optional)
|
||||||
Klöckner-Moeller |
✓ (optional)
|
✓ (optional)
|
||||||
Mitsubishi |
✓ (optional)
|
✓ (optional)
|
||||||
SMS-sending/Pager(S5/S7) |
✓
|
✓
|
✓
|
✓ (no pager)
|
only for analogue / ISDN
|
|||
HMI-messaging module(S5/S7) |
✓
|
✓
|
||||||
SMS-receive with GSM |
✓
|
|||||||
DTMF with analogue |
✓
|
|||||||
e-mail-dispatch |
✓
|
✓
|
✓
|
|||||
FAX-dispatch(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
only for analogue / ISDN
|
||||
PLC-data coupling(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
✓
|
|||
ASCII-transfer from S5/S7 |
✓
|
✓ (optional)
|
✓ (optional)
|
only with ASCII-LAN
|
||||
internet-coupling |
✓
|
|||||||
Usage as dial-up-router |
✓
|
✓
|
||||||
power supply |
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
dimensions w x h x d (in mm) |
High: 67 x 280 x 170
FLAT: 300 x 175 x 70 |
300 x 175 x 66
|
235 x 162 x 37
|
90 x 162 x 54
|
40 x 125 x 115
|
42 x 15 x 65
|
65 x 43 x 17
|
154 x 92 x 28
|
* other PLC types on request |
Also available as a set for universal use: S5/S7-BRIDGE-WIFI-Sets
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
Quite simply directly for all Siemens Step5, PG-2000, any other S5 package and WinCC projects.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-firmware-file
Configuration-tool / update-tool for Windows XP, 7/VISTA/8/10/11 32/64 bit:
download-S5-LAN-Manager inclusive PLC-firmware-file
Highlights:
- Move around the machine without restrictions during commissioning or maintenance!
Application areas:
- Commissioning of machines directly on PLC interface.
- Connection of mobile devices to the fieldbus system.
- Universal coupling of all PLC machines, no matter which interfaces are available!
- WIFI programming adapter for service applications, once parameterized, thanks to flash memory without data loss, independent of power failures.
- PUT/GET of S7-1500/1200/300/400 (PN-CPU or with Ethernet-CP), also ACTIVE , with specified and unspecified connection possible.
- VPN remote maintenance possible, to maintain the PLC via the Internet.
- Coupling with DB-Transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5-Gateway.
- any TCP device writes/reads DB`s in the S5 control.
Configuration:
- Easiest configuration through intuitive operation!
The S5 bridge is designed for fast commissioning .
After the module has been plugged into the plc, only assigne the IP address is via the S5-LAN Manager. After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
- Plug in the module, activate WLAN on the laptop, connect with Bridge-WLAN -> DONE
STEP-7 / TIA / WIN-CC / MICROWIN:
Each network device that speaks RFC1006 S7-TCP/IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP/IP and expands every MPI bus/PROFIBUS by a S5 network gateway.
It does not matter which control types, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- No expensive CP's needed for PLC-couplings.
- Supports remote maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S5 bridge can be used directly as a WLAN gateway for PLCs among each other device. Programming and visualizing S5 PLCs via WLAN is no longer a problem. Thanks to ext. Power supply usable on all controllers.
The S5 SPS Bridge with all functions is the perfect PLC network adapter for each application.
S5-Bridge is a reliable and handy S5-WIFI network adapter for every technician .
The compact design and the power supply directly from the CPU,
enable a PLC ** to be connected to the Ethernet in less than 5 minutes.
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
Quite simply directly for all Siemens Step5, PG-2000, any other S5 package and WinCC projects.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-firmware-file
Configuration-tool / update-tool for Windows XP, 7/VISTA/8/10/11 32/64 bit:
download-S5-LAN-Manager inclusive PLC-firmware-file
Highlights:
- Parallel operation of several connections e.g. Remote maintenance, programming, visualization and much more is possible.
- Replacement for e.g. expensive CP
- Coupling to each ERP system e.g. about OPC logs.
- No PLC knowledge required
- Active module, thanks to its own power sources no influence on the S5.
- Communication with Fetch/Write
- Ideal for process visualization
- Open TCP/IP protocol
- RK 512 and TCP/IP H1-ISO-On-TCP RFC1006 (CP1430 TCP) supported
- Available in the variants 3964R-LAN, ASCII-LAN, PG-LAN, and for MUX757.
- Move around the machine without restrictions during commissioning or maintenance!
- Work where problems are visible and comprehensible!
Application areas:
- Commissioning of machines directly on PLC interface.
- Connection of mobile devices to the fieldbus system.
- Universal coupling of all PLC machines, no matter which interfaces are available!
- WIFI programming adapter for service applications, once parameterized, thanks to flash memory without data loss, independent of power failures.
- PUT/GET of S7-1500/1200/300/400 (PN-CPU or with Ethernet-CP), also ACTIVE , with specified and unspecified connection possible.
- VPN remote maintenance possible, to maintain the PLC via the Internet.
- Coupling with DB-Transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5-Gateway.
- any TCP device writes/reads DB`s in the S5 control.
Configuration:
- Easiest configuration through intuitive operation!
The S5 bridge is designed for fast commissioning .
After the module has been plugged into the plc, only assigne the IP address is via the S5-LAN Manager. After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
- Plug in the module, activate WLAN on the laptop, connect with Bridge-WLAN -> DONE
STEP-7 / TIA / WIN-CC / MICROWIN:
Each network device that speaks RFC1006 S7-TCP/IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP/IP and expands every MPI bus/PROFIBUS by a S5 network gateway.
It does not matter which control types, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- No expensive CP's needed for PLC-couplings.
- Supports remote maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S5 bridge can be used directly as a WLAN gateway for PLCs among each other device. Programming and visualizing S5 PLCs via WLAN is no longer a problem. Thanks to ext. Power supply usable on all controllers.
The S5 SPS Bridge with all functions is the perfect PLC network adapter for each application.
S5-Bridge is a reliable and handy S5-WIFI network adapter for every technician .
The compact design and the power supply directly from the CPU,
enable a PLC ** to be connected to the Ethernet in less than 5 minutes.
Remote maintenance / telecontrol of PLC
Access to the connected PLC takes place by coupling via Analogue-, ISDN-, mixed Analogue-ISDN-, GSM-, UMTS-line and also via Internet with and without VPN-security.
Analogue and ISDN - how do they come together?
You have on the plant side only ISDN for telephone, but in your office there is only an analogue system? No problem, you have to install on the clients side the TP-II and activate there the analogue-emulation in the device. No, the modem signals will be send digitalized over ISDN and you can connect to it. So, you will be able to communicate though the telephone systems are different and your client isn´t forced to install an analogue connection.
Router - Mode (access to the network without router)
The Tele-Prof-II can also be used as a router for access from a PC via dial-up connection, so that a communication with the behind covered network results. Furthermore a network connection can be
made with the TP-II <=> TP-II-line, but in doing so the IP-address-root must differ.
User dependant network access
You have PLC/LAN-participants different supplier in your network and everybody should have access to this network? No problem, you give every supplier a VPN-username and passwort, define in the
destination device a user-dependent network-access and after positiv login he only can communicate to the released ip-addresses.
Separate your machine-net from the office-net
You need a separation between the machine-net and the office-net? No problem, plug a PCMCIA-LAN-card in your Tele-Prof-II-device (only for version -H) and the separation is OK. You have access to
both nets via remote maintenance.
S7-CP-alternate (without LAN-CP to the PLC)
Do you have a PLC without CP343-1 or CP443-1 and a TP-II as remote maintenance device? Then activate the CP-mode of the TP-II and your visualisation goes directly ONLINE via the LAN of the TP-II.
PLC coupling (data exchange between PLCs)
Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Thereto no
dedicated line is required, a “normal” telephone connection is sufficient because the devices cut the line after occured message.
Failure report transmission without any change in the PLC programm
Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, as SMS to your mobile phone, to your pager or also via e-mail. And this without an intervention
of the PLC-program. Here the variables and actions are stored and processed in the TP-II.
Failure report transmission released by the PLC
Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, as SMS to your mobile phone, to your pager or also via e-mail.
Remote maintenance of centralized PLC-devices
You have many PLC and you want to programm them central on one place? No problem, you have to connect them all to the KOR/MUX-Tele-Switch, connect it with the TP-II and after telephone connect you
will be able with the PD-bus-selection of your Step5-software to go ONLINE. Of course the MOR/MUX-Tele-Switch is cascadable, so you can connect up to 30 PLCs to the devices.
Sending ASCII-data to a PC
Your car park or control sends the configuration / capacity utilisation to a PC with a modem, so that the data can be used for further processing.
Direct-mode "extended serial interface"
There is an unsupported control or data logger or converter integrated in your installation which protocol is not supported? No problem, the signs that the PC in the office sends will be
transferred via telephone line by the Direct-mode, and on-site reproduced by the TP-II. The way back is identical. So in that case there’s also a communication to the electronic devices
available.
Data logger with FTP-interface
You need a data logger which tape-records the specified data of the PLC and you can collect the data via FTP on demand. No problem, TP-II with the option Datalogger is the solution for you.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 15 watt |
Display: |
expressive LCD display 5 status LEDs |
Handling/Configuration: |
integrated keypad WEB-Browser |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBdTTY/20mA current loop (AG-TELE aktiv, PLC passiv) RS232: 9,6 KBd - 115,2 KBd / fully assigned
to the PD/PC:
10/100BaseTX RJ45-ethernet jackTTY/20mA current loop (100 % mechanically and electr. compatible) RS232: 9,6 KBd - 115,2 KBd / with a 1on1-cable to the PC
others:
2xUSB, 2xPCMCIA (only for version -H) |
Integrated modem: |
33K6 HIGH-SPEED, V.42/BIS MNP5 analogue modem ISDN (Euro ISDN + 1TR6) |
Operating temperature: | 0 - 55°C |
Case: | powder coated metal case with mounting flange and DIN-rail mounting |
Dimensions: |
Flat 300 x 175 x 70 mm Hoch 67 x 280 x 170 mm |
Scope of delivery: |
Tele-Prof-II Power connector 3pins big |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
11,00 €
plus VAT. and shipping
plus VAT. and shipping
28,00 €
plus VAT. and shipping
plus VAT. and shipping
9361-3
S5-connecting cable 3m
forTELE-PROF, MINI-/PG-MUX-II
S5-connecting cable 3m
forTELE-PROF, MINI-/PG-MUX-II
9361-3.05M
S5-connecting cable 5m
for TELE-PROF, MINI-/PG-MUX-II
S5-connecting cable 5m
for TELE-PROF, MINI-/PG-MUX-II
9361-3.06M
S5-connecting cable 6m
for TELE-PROF, MINI-/PG-MUX-II
S5-connecting cable 6m
for TELE-PROF, MINI-/PG-MUX-II
9361-3.10M
S5-connecting cable 10m
for TELE-PROF, MINI-/PG-MUX-II
S5-connecting cable 10m
for TELE-PROF, MINI-/PG-MUX-II
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
244,00 €
plus VAT. and shipping
plus VAT. and shipping
22,00 €
plus VAT. and shipping
plus VAT. and shipping
63,00 €
plus VAT. and shipping
plus VAT. and shipping
172,00 €
plus VAT. and shipping
plus VAT. and shipping
4,00 €
plus VAT. and shipping
plus VAT. and shipping
105,00 €
plus VAT. and shipping
plus VAT. and shipping
199,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
27,00 €
plus VAT. and shipping
plus VAT. and shipping
59,00 €
plus VAT. and shipping
plus VAT. and shipping
9636-CROSS
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
9636-TCPIP
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
All prices plus costs of delivery, shipping insurance and VAT.
9372-OEM
TELE-PROFessional II worldwide use
OEM - Version (all accessories optional) without PCMCIA-Slot for UMTS-/LAN-card
TELE-PROFessional II worldwide use
OEM - Version (all accessories optional) without PCMCIA-Slot for UMTS-/LAN-card
1260,00 €
plus VAT. and shipping
plus VAT. and shipping
9372-FLAT
TELE-PROFessional II worldwide use
flat version / OEM - Version (all accessories optional) without PCMCIA-slot for UMTS-/LAN-card
TELE-PROFessional II worldwide use
flat version / OEM - Version (all accessories optional) without PCMCIA-slot for UMTS-/LAN-card
1260,00 €
plus VAT. and shipping
plus VAT. and shipping
9372-FLAT-H
TELE-PROFessional II worldwide use
flat version / OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
TELE-PROFessional II worldwide use
flat version / OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
1313,00 €
plus VAT. and shipping
plus VAT. and shipping
Analogue-telefone
TELE-PROFessional (TP)
Facilities management world wide – remote maintenance and diagnosis via telephone
Facilities management world wide – remote maintenance and diagnosis via telephone
TELE-BOOK (TB)
PLC-remote maintenance also available from the car, with 12V power supply
PLC-remote maintenance also available from the car, with 12V power supply
TeleRouter
The simple and quick router solution for automation
The simple and quick router solution for automation
Analogue-telefone
TELE-PROFessional (TP)
Facilities management world wide – remote maintenance and diagnosis via telephone
Facilities management world wide – remote maintenance and diagnosis via telephone
TELE-BOOK (TB)
PLC-remote maintenance also available from the car, with 12V power supply
PLC-remote maintenance also available from the car, with 12V power supply
MPI / PPI - Profibusmodem
Programming of S7-PLC’s via telephone from afar
Programming of S7-PLC’s via telephone from afar
TeleRouter
The simple and quick router solution for automation
The simple and quick router solution for automation
ISDN
TeleRouter
The simple and quick router solution for automation
The simple and quick router solution for automation
ISDN
TeleRouter
The simple and quick router solution for automation
The simple and quick router solution for automation
TELEService analogue
Remote maintenance of PPI, MPI and Profibus <=> analogue 56K-, ISDN-, GSM-Modem
Remote maintenance of PPI, MPI and Profibus <=> analogue 56K-, ISDN-, GSM-Modem
TELEService isdn
Remote maintenance of PPI, MPI and Profibus <=> analogue 56K-, ISDN-, GSM-Modem
Remote maintenance of PPI, MPI and Profibus <=> analogue 56K-, ISDN-, GSM-Modem
All prices plus costs of delivery, shipping insurance and VAT.
11,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-LANCON
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
423,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
452,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
174,00 €
plus VAT. and shipping
plus VAT. and shipping
145,00 €
plus VAT. and shipping
plus VAT. and shipping