Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK
S5-BRIDGE - Process Informatik Entwicklungsgesellschaft mbH

S5-BRIDGE


ONLINE with S5PLC without cable +++ S5-adapter 90-155U/CPs/IPs +++ No WIFi-infrastructure +++ Integrated access-point +++ Configuration via WebAccess +++ S5 Bridge (TTY - LAN - WIFI)

as PLC-or PG-TELE switchable

Also available as a set for universal use: S5/S7-BRIDGE-WIFI-Sets

Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.

Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.

! Parallel access via LAN/WIFI thanks to included multiplexer !

more...
1165,00 € plus VAT. and shipping

ARTNR: 9380
TELE-BOOK PLC remote maintenance
Obsolete
EAN number: 4260363240338
HS-code: 85389099



Remote maintenance

TELE LINK NETWORK
         
 
secured modem-protocol
additional software needed
Siemens TS -Software
Siemens TS -Software
VPN-Client
VPN-Client
Providing WinTELEPROF-software
modem
analogue/ISDN
analogue
opt. via PCMCIA
analogue/GSM
analogue/ISDN/GSM
internet-connection
internet-connection
internet-connection
modem for world wide use
interfaces
MPI/Profibus
9600-12MBd
9600-12MBd
9600-12MBd
9600-12MBd
RS232
2x
2x
2x
1x
1x
TTY
2x
2x
2x
1x
PCMCIA
2x (optionally)
1x
1x
Ethernet
10/100BaseTx
1x
1x
5x
USB
2x
1x
LCD-display
instead 10 LEDs
instead status-LED
instead webserver
instead webserver
supported PLC-protocols *
S7
S5
✓ (optional)
✓ (optional)
Pilz PSS
✓ (optional)
✓ (optional)
Allen-Bradley
✓ (optional)
✓ (optional)
AEG
✓ (optional)
✓ (optional)
Bosch
✓ (optional)
✓ (optional)
Telemecanique
✓ (optional)
✓ (optional)
GE-Fanuc
✓ (optional)
✓ (optional)
Klöckner-Moeller
✓ (optional)
✓ (optional)
Mitsubishi
✓ (optional)
✓ (optional)
SMS-sending/Pager(S5/S7)
✓ (no pager)
only for analogue / ISDN
HMI-messaging module(S5/S7)
SMS-receive with GSM
DTMF with analogue
e-mail-dispatch
FAX-dispatch(S5/S7)
✓ (optional)
✓ (optional)
only for analogue / ISDN
PLC-data coupling(S5/S7)
✓ (optional)
✓ (optional)
ASCII-transfer from S5/S7
✓ (optional)
✓ (optional)
only with ASCII-LAN
internet-coupling
Usage as dial-up-router
power supply
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
dimensions w x h x d (in mm)
High: 67 x 280 x 170
FLAT: 300 x 175 x 70
300 x 175 x 66
235 x 162 x 37
90 x 162 x 54
40 x 125 x 115
42 x 15 x 65
65 x 43 x 17
154 x 92 x 28

* other PLC types on request
Also available as a set for universal use: S5/S7-BRIDGE-WIFI-Sets

Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.

Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.

! Parallel access via LAN/WIFI thanks to included multiplexer !
Quite simply directly for all Siemens Step5, PG-2000, any other S5 package and WinCC projects.

New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-firmware-file

Configuration-tool / update-tool for Windows XP, 7/VISTA/8/10/11 32/64 bit:
download-S5-LAN-Manager inclusive PLC-firmware-file

Highlights:
  • Parallel operation of several connections e.g. Remote maintenance, programming, visualization and much more is possible.
  • Replacement for e.g. expensive CP
  • Coupling to each ERP system e.g. about OPC logs.
  • No PLC knowledge required
  • Active module, thanks to its own power sources no influence on the S5.
  • Communication with Fetch/Write
  • Ideal for process visualization
  • Open TCP/IP protocol
  • RK 512 and TCP/IP H1-ISO-On-TCP RFC1006 (CP1430 TCP) supported
  • Available in the variants 3964R-LAN, ASCII-LAN, PG-LAN, and for MUX757.

- Move around the machine without restrictions during commissioning or maintenance!
    • Work where problems are visible and comprehensible!

Application areas:
- Commissioning of machines directly on PLC interface.
- Connection of mobile devices to the fieldbus system.
- Universal coupling of all PLC machines, no matter which interfaces are available!
- WIFI programming adapter for service applications, once parameterized, thanks to flash memory without data loss, independent of power failures.

- PUT/GET of S7-1500/1200/300/400 (PN-CPU or with Ethernet-CP), also ACTIVE , with specified and unspecified connection possible.
- VPN remote maintenance possible, to maintain the PLC via the Internet.
- Coupling with DB-Transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5-Gateway.
- any TCP device writes/reads DB`s in the S5 control.

Configuration:
- Easiest configuration through intuitive operation!

The S5 bridge is designed for fast commissioning .
After the module has been plugged into the plc, only assigne the IP address is via the S5-LAN Manager. After that, the controllers can already be accessed from the network.

NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!

- Plug in the module, activate WLAN on the laptop, connect with Bridge-WLAN -> DONE

STEP-7 / TIA / WIN-CC / MICROWIN:
Each network device that speaks RFC1006 S7-TCP/IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP/IP and expands every MPI bus/PROFIBUS by a S5 network gateway.
It does not matter which control types, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- No expensive CP's needed for PLC-couplings.
- Supports remote maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.

Programming / Adapting / Converting
The S5 bridge can be used directly as a WLAN gateway for PLCs among each other device. Programming and visualizing S5 PLCs via WLAN is no longer a problem. Thanks to ext. Power supply usable on all controllers.
The S5 SPS Bridge with all functions is the perfect PLC network adapter for each application.

S5-Bridge is a reliable and handy S5-WIFI network adapter for every technician .
The compact design and the power supply directly from the CPU,
enable a
PLC ** to be connected to the Ethernet in less than 5 minutes.
Use in the car with a 12V supply only
Produkbild
Your’re on road with your car and your employee reports a failure? What next? Approach the next parking place and try to get a telephone line to solve the problem? Or solve the problem in your head? Hit the next parking place and start your Tele-Book which is plugged on your car’s cigarette lighter, and build-up a connection to your installation. With the notebook you will solve the problem within a short time.
Remote maintenance / telecontrol of PLC-devices
Produkbild
Access to the connected PLC takes place by coupling via Analogue-, ISDN- (only with AB-adapter) and GSM-(only with external GSM-modem)-line.
PLC-coupling (data exchange between PLC-devices)
Produkbild
Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Thereto no dedicated line is required, a “normal” telephone connection is sufficient because the devices hangs up the line after occured message.
Failure report transmission released by the PLC
Produkbild

Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, to your mobile phone as SMS or to your pager.

Sending ASCII-data to a PC
Produkbild
Your car park or control sends the configuration/capacity utilisation to a PC with a modem, so that the data can be used for further processing.
Direct-mode „extended serial interface“
Produkbild
There is an unsupported control or data logger or converter integrated in your installation which protocol is not supported? No problem, the signs that the PC in the office sends will be transferred via telephone line by the Direct-mode , and on-site reproduced by the TP/TB. The way back is identical. So in that case there’s also a communication to the electronic devices available.
Supply voltage: 24V DC (12 - 36V)
Power consumption: 3 watt
Display: expressive LCD-display
Handling/Configuration: integrated keypad
Tele-Manager
Interfaces:
to the PLC:
RS232: 9,6 KBd - 115,2 KBd / fully assigned
to the PD/PC:
TTY/20mA current loop (100 % mechanically and electr. compatible)
RS232: 9,6 KBd - 115,2 KBd / with a 1on1-cable to the PC
others:
1 x PCMCIA
Integrated modem: -
Operating temperature: 0 - 55°C
Case: powder coated metal table case
Dimensions: 233 x 162 x 39 mm
 
Scope of delivery: TELE-BOOK
Power connector 3pins big
All prices plus costs of delivery, shipping insurance and VAT.

options:

9370.A
Option TP+TB AEG
TELE-PROFessional for AEG A120,A250 PLC- or PD-TELE switchable
Quickbestellung INFOMAIL
by e-mail
1273,00 €
plus VAT. and shipping


9370.KM
Option TP+TB Klöckner-Moeller
TELE-PROFessional for Klöckner-Moeller
Quickbestellung INFOMAIL
by e-mail
1273,00 €
plus VAT. and shipping


9370.T
Option TP+TB Telemechanique
TELE-PROFessional for Telemechanique
Quickbestellung INFOMAIL
by e-mail
1273,00 €
plus VAT. and shipping


9370.P
Option TP+TB Pilz
TELE-PROFessional for Pilz PSS
Quickbestellung INFOMAIL
by e-mail
1273,00 €
plus VAT. and shipping


9370.AB
Option TP+TB Allen-Bradley
TELE-PROFessional for Allen-Bradley PLC- or PD-TELE switchable
Quickbestellung INFOMAIL
by e-mail
1273,00 €
plus VAT. and shipping


9370-11
Option ASCII-TELE

ASCII-transfer of DB-contents from S5/7-PLC to a modem
Quickbestellung INFOMAIL
by e-mail
251,00 €
plus VAT. and shipping


9370.B
Option TP+TB Bosch
TELE-PROFessional for Bosch
Quickbestellung INFOMAIL
by e-mail
1273,00 €
plus VAT. and shipping


9370-6
Option L1 with CP-cable

programming of S5-PLC's with a CP via L1-bus with PD-path selection
Quickbestellung INFOMAIL
by e-mail
251,00 €
plus VAT. and shipping


9370.M
Option TP+TB Mitsubishi
TELE-PROFessional for Mitsubishi
Quickbestellung INFOMAIL
by e-mail
1273,00 €
plus VAT. and shipping


9370-3
Option FAX-TELE

sending DB-contents from S5/7-PLC's to a fax machine
Quickbestellung INFOMAIL
by e-mail
251,00 €
plus VAT. and shipping


9370-5
Option L2 with CP-cable

programming of S5-PLC's with a CP via L2-bus with PD-path selection
Quickbestellung INFOMAIL
by e-mail
251,00 €
plus VAT. and shipping


9370-2
Option PLC-TELE

transfer of DB-contents between S5/7-PLC's
Quickbestellung INFOMAIL
by e-mail
251,00 €
plus VAT. and shipping


9370-7
Option H1 with CP-cable

programming of S5-PLC's with a CP via H1-bus with PD-path selection
Quickbestellung INFOMAIL
by e-mail
251,00 €
plus VAT. and shipping


9370.G
Option TP+TB GE-Fanuc
TELE-PROFessional for GE-Fanuc
Quickbestellung INFOMAIL
by e-mail
1273,00 €
plus VAT. and shipping


accessories:

9370-ISDN
ISDN-adapter for analogue terminals

full ISDN-functionality e.g. call waiting, 3-way conferencing, broker's call
Quickbestellung INFOMAIL
by e-mail
267,00 €
plus VAT. and shipping


9381
TAE-modemPCMCIA-card for TELE-BOOK Obsolete

pcmcia-card inclusive telefon-lead and TAE-adapter
Quickbestellung INFOMAIL
by e-mail
218,00 €
plus VAT. and shipping


9370-TAE
TAE junction box

analogue telephone box (NFN) for on-wall mounting
Quickbestellung INFOMAIL
by e-mail
22,00 €
plus VAT. and shipping


9371-6
Servicebag

for TP, TB + TP-II-FLAT
Quickbestellung INFOMAIL
by e-mail
63,00 €
plus VAT. and shipping


9381.KABEL
Analogue cable for TAE-modem PCMCIA Obsolete

PCMCIA-modemcard connection <=> TAE plug Germany/USA (spare part)
Quickbestellung INFOMAIL
by e-mail
55,00 €
plus VAT. and shipping


218,00 €
plus VAT. and shipping


9391.1
24V DC power-supply unit 625mA

Primary 110V - 240 VAC Euro+USA-plug
Quickbestellung INFOMAIL
by e-mail
59,00 €
plus VAT. and shipping


9372-24
Power connector 3pins big

connector plug lockable by jack with screws
Quickbestellung INFOMAIL
by e-mail
4,00 €
plus VAT. and shipping


55,00 €
plus VAT. and shipping


All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.

Automatic-mode

Documentation

Extension

Support-videos