S5-BRIDGE
ONLINE with S5PLC without cable +++ S5-adapter 90-155U/CPs/IPs +++ No WIFi-infrastructure +++ Integrated access-point +++ Configuration via WebAccess +++ S5 Bridge (TTY - LAN - WIFI)
24V miniature device as cap
Also available as a set for universal use: S5/S7-BRIDGE-WIFI-SetsProduct Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
more...
180,00 € plus VAT. and shipping
ARTNR: 9363-3-B
EPROM-Eraser UVL3
EAN number: | 4260363241779 | |
HS-code: | 85394910 | |
Weight: | 0.7 kg |
Memory modules / Prommer
Mini-Prommer-III |
Flash-Prommer-II-MMC |
Multi-Prommer |
||||||
---|---|---|---|---|---|---|---|---|
Supported formats |
Windows XP (16-Bit-Version) |
Windows 7 (32-Bit-Version) |
Windows XP (16-Bit-Version) |
Windows 7 (32-Bit-Version) |
Windows XP (16-Bit-Version) |
Windows 7 (32-Bit-Version) |
||
Binäryfile *.BIN | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ||
Step-5 file *.S5D | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ||
Step-7 file(structur) *.S7P | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ||
S7-PLC-firmware-update (MMC) | ✓ | ✓ | ||||||
ET-100 files *.308 | ✓ | ✓ | ✓ | |||||
ET-200 files *ET.200 | ✓ | ✓ | ✓ | |||||
ET2-Binäryexport *.2BF | ✓ | ✓ | ✓ | |||||
Intel-Hex-format *.HEX | ✓ | ✓ | ✓ | |||||
Motorola-Hex-format *.EPR | ✓ | ✓ | ✓ | |||||
CP-525/524 files *.525 | ✓ | ✓ | ✓ | |||||
CP-5431-files Q*.* | ✓ | ✓ | ✓ | |||||
CP-1430/CP-143-files A*.* | ✓ | ✓ | ✓ | |||||
Module type | Storage type | Slot | ||||||
2532 | UV, NMOS | DIL-Socket | ✓ | |||||
27128 | UV, NMOS | DIL-Socket | ✓ | ✓ | ||||
2732A | UV, NMOS | DIL-Socket | ✓ | ✓ | ||||
2764 | UV, NMOS | DIL-Socket | ✓ | ✓ | ||||
27C010 | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
27C1001 | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
27C128 | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
2716BQ | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
27C200 | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
27C256 | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
27C400 | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
27C512 | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
27C64A | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
27C080 | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
27C801 | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
28F010 | FLASH | DIL-Socket | ||||||
29F010 | FLASH | DIL-Socket | ✓ | ✓ | ||||
370-0AA41 | UV, CMOS | VG-strip | ✓ (only reading) | ✓ (only reading) | ||||
372-0AA51 | UV, NMOS | VG-strip | ✓ (only reading) | ✓ (only reading) | ||||
372-0AA61 | UV, NMOS | VG-strip | ✓ (only reading) | ✓ (only reading) | ||||
373-0AA21 | UV, NMOS | VG-strip | ✓ | ✓ | ||||
373-0AA41 | UV, NMOS | VG-strip | ✓ (ab V1.5) | ✓ | ||||
373-0AA61 | UV, NMOS | VG-strip | ✓ (ab V1.5) | ✓ | ||||
373-0AA81 | UV, CMOS | VG-strip | ✓ (ab V1.5) | ✓ | ||||
373-1AA41 | UV, CMOS | VG-strip | ✓ | ✓ | ||||
373-1AA61 | UV, CMOS | VG-strip | ✓ | ✓ | ||||
373-1AA81 | UV, CMOS | VG-strip | ✓ | ✓ | ||||
374-1FG11 | FLASH | PCMCIA | ✓ | ✓ (ab V3.15) | ||||
374-1FH11 | FLASH | PCMCIA | ✓ | ✓ (ab BS3.E) | ||||
374-1FH21 | FLASH | PCMCIA | ✓ | ✓ | ||||
374-1KG11 | FLASH | PCMCIA | ✓ | ✓ | ||||
374-1KJ11 | FLASH | PCMCIA | ✓ | ✓ | ||||
374-1KH21 | FLASH | PCMCIA | ✓ | ✓ | ||||
374-1KK21 | FLASH | PCMCIA | ✓ | ✓ | ||||
374-2FH21 | FLASH | PCMCIA | ✓ | ✓ | ||||
374-2KG21 | FLASH | PCMCIA | ✓ | ✓ | ||||
374-2KH21 | FLASH | PCMCIA | ✓ | ✓ | ||||
374-2KK21 | FLASH | PCMCIA | ✓ | ✓ | ||||
374-2KL21 | FLASH | PCMCIA | ✓ | ✓ | ||||
375-0LA11 | UV, NMOS | VG-strip | ✓ | ✓ | ||||
375-0LA15 | UV, NMOS | VG-strip | ✓ | ✓ | ||||
375-0LA21 | UV, NMOS | VG-strip | ✓ | ✓ | ||||
375-0LA41 | UV, NMOS | VG-strip | ✓ | ✓ | ||||
375-0LA61 | UV, CMOS | VG-strip | ✓ (ab V1.5) | ✓ | ||||
375-0LA71 | UV, CMOS | VG-strip | ✓ | ✓ | ||||
375-0LC11 | EEPROM | VG-strip | ✓ | ✓ | ||||
375-0LC15 | EEPROM | VG-strip | ✓ | ✓ | ||||
375-0LC21 | EEPROM | VG-strip | ✓ | ✓ | ||||
375-0LC31 | EEPROM | VG-strip | ✓ | ✓ | ||||
375-0LC41 | EEPROM | VG-strip | ✓ | ✓ | ||||
375-0LC61 | EEPROM | VG-strip | ✓ | ✓ | ||||
375-1LA15 | UV, CMOS | VG-strip | ✓ | ✓ | ||||
375-1LA21 | UV, CMOS | VG-strip | ✓ | ✓ | ||||
375-1LA41 | UV, CMOS | VG-strip | ✓ (ab V1.5) | ✓ | ||||
375-1LA61 | UV, CMOS | VG-strip | ✓ | ✓ | ||||
375-1LA71 | UV, CMOS | VG-strip | ✓ | ✓ | ||||
375-8LA11 | UV, CMOS | VG-strip | ✓ | ✓ | ||||
375-8LA12 | FLASH | VG-strip | ✓ (ab V1.6) | ✓ | ||||
375-8LC11 | EEPROM | VG-strip | ✓ | ✓ | ||||
375-8LC21 | EEPROM | VG-strip | ✓ | ✓ | ||||
375-TPA1 | EEPROM | VG-strip | ✓ (ab V1.5) | ✓ | ||||
376-0AA11 | UV, NMOS | VG-strip | ✓ | ✓ | ||||
376-0AA21 | UV, NMOS | VG-strip | ✓ | ✓ | ||||
376-0AA31 | UV, CMOS | VG-strip | ✓ | ✓ | ||||
376-1AA11 | UV, CMOS | VG-strip | ✓ | ✓ | ||||
376-1AA21 | UV, CMOS | VG-strip | ✓ (ab V1.5) | ✓ | ||||
376-1AA31 | UV, CMOS | VG-strip | ✓ | ✓ | ||||
6FX1126-0B !Number has to be the same! |
UV, CMOS | VG-strip | ✓ | ✓ | ||||
6FX1128-4B !Number has to be the same! Don't confuse with 6FX1128-4BB10, there is no compatibility! |
UV, CMOS | VG-strip | ✓ | ✓ | ||||
6FX1130-5B !Number has to be the same! |
UV, CMOS | VG-strip | ✓ | ✓ | ||||
910-0AA31 | UV, NMOS | VG-strip | ✓ (only reading) | ✓ (only reading) | ||||
910-0AA41 | UV, NMOS | VG-strip | ✓ (only reading) | ✓ (only reading) | ||||
951-0FD00 | FLASH | PCMCIA | ✓ | ✓ | ||||
951-0KD00 | FLASH | PCMCIA | ✓ | ✓ | ||||
951-0KD80 | FLASH | PCMCIA | ✓ | ✓ | ||||
951-0KE00 | FLASH | PCMCIA | ✓ | ✓ | ||||
951-0KE80 | FLASH | PCMCIA | ✓ | ✓ | ||||
951-0KF00 | FLASH | PCMCIA | ✓ | ✓ | ||||
951-0KF80 | FLASH | PCMCIA | ✓ | ✓ | ||||
951-0KG00 | FLASH | PCMCIA | ✓ | ✓ | ||||
951-0KJ00 | FLASH | PCMCIA | ✓ | ✓ | ||||
951-1KH00 | FLASH | PCMCIA | ✓ | ✓ | ||||
951-1KK00 | FLASH | PCMCIA | ✓ | ✓ | ||||
951-1KM00 | FLASH | PCMCIA | ✓ | ✓ | ||||
952-0KD00 | FLASH | PCMCIA | ✓ | ✓ | ||||
952-0KE00 | FLASH | PCMCIA | ✓ | ✓ | ||||
952-0KF00 | FLASH | PCMCIA | ✓ | ✓ | ||||
952-0KG00 | FLASH | PCMCIA | ✓ | ✓ | ||||
952-0KH00 | FLASH | PCMCIA | ✓ | ✓ | ||||
952-1KK00 | FLASH | PCMCIA | ✓ | ✓ | ||||
952-1KL00 | FLASH | PCMCIA | ✓ | ✓ | ||||
952-1KM00 | FLASH | PCMCIA | ✓ | ✓ | ||||
A1SMCY_8KP | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
FX_EEPROM4 | UV, CMOS | DIL-Socket | ✓ | ✓ | ||||
FX_EPROM_8 | UV, CMOS | DIL-Socket | ✓ | ✓ |
Also available as a set for universal use: S5/S7-BRIDGE-WIFI-Sets
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
Quite simply directly for all Siemens Step5, PG-2000, any other S5 package and WinCC projects.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-firmware-file
Configuration-tool / update-tool for Windows XP, 7/VISTA/8/10/11 32/64 bit:
download-S5-LAN-Manager inclusive PLC-firmware-file
Highlights:
- Move around the machine without restrictions during commissioning or maintenance!
Application areas:
- Commissioning of machines directly on PLC interface.
- Connection of mobile devices to the fieldbus system.
- Universal coupling of all PLC machines, no matter which interfaces are available!
- WIFI programming adapter for service applications, once parameterized, thanks to flash memory without data loss, independent of power failures.
- PUT/GET of S7-1500/1200/300/400 (PN-CPU or with Ethernet-CP), also ACTIVE , with specified and unspecified connection possible.
- VPN remote maintenance possible, to maintain the PLC via the Internet.
- Coupling with DB-Transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5-Gateway.
- any TCP device writes/reads DB`s in the S5 control.
Configuration:
- Easiest configuration through intuitive operation!
The S5 bridge is designed for fast commissioning .
After the module has been plugged into the plc, only assigne the IP address is via the S5-LAN Manager. After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
- Plug in the module, activate WLAN on the laptop, connect with Bridge-WLAN -> DONE
STEP-7 / TIA / WIN-CC / MICROWIN:
Each network device that speaks RFC1006 S7-TCP/IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP/IP and expands every MPI bus/PROFIBUS by a S5 network gateway.
It does not matter which control types, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- No expensive CP's needed for PLC-couplings.
- Supports remote maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S5 bridge can be used directly as a WLAN gateway for PLCs among each other device. Programming and visualizing S5 PLCs via WLAN is no longer a problem. Thanks to ext. Power supply usable on all controllers.
The S5 SPS Bridge with all functions is the perfect PLC network adapter for each application.
S5-Bridge is a reliable and handy S5-WIFI network adapter for every technician .
The compact design and the power supply directly from the CPU,
enable a PLC ** to be connected to the Ethernet in less than 5 minutes.
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
Quite simply directly for all Siemens Step5, PG-2000, any other S5 package and WinCC projects.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-firmware-file
Configuration-tool / update-tool for Windows XP, 7/VISTA/8/10/11 32/64 bit:
download-S5-LAN-Manager inclusive PLC-firmware-file
Highlights:
- Parallel operation of several connections e.g. Remote maintenance, programming, visualization and much more is possible.
- Replacement for e.g. expensive CP
- Coupling to each ERP system e.g. about OPC logs.
- No PLC knowledge required
- Active module, thanks to its own power sources no influence on the S5.
- Communication with Fetch/Write
- Ideal for process visualization
- Open TCP/IP protocol
- RK 512 and TCP/IP H1-ISO-On-TCP RFC1006 (CP1430 TCP) supported
- Available in the variants 3964R-LAN, ASCII-LAN, PG-LAN, and for MUX757.
- Move around the machine without restrictions during commissioning or maintenance!
- Work where problems are visible and comprehensible!
Application areas:
- Commissioning of machines directly on PLC interface.
- Connection of mobile devices to the fieldbus system.
- Universal coupling of all PLC machines, no matter which interfaces are available!
- WIFI programming adapter for service applications, once parameterized, thanks to flash memory without data loss, independent of power failures.
- PUT/GET of S7-1500/1200/300/400 (PN-CPU or with Ethernet-CP), also ACTIVE , with specified and unspecified connection possible.
- VPN remote maintenance possible, to maintain the PLC via the Internet.
- Coupling with DB-Transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5-Gateway.
- any TCP device writes/reads DB`s in the S5 control.
Configuration:
- Easiest configuration through intuitive operation!
The S5 bridge is designed for fast commissioning .
After the module has been plugged into the plc, only assigne the IP address is via the S5-LAN Manager. After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
- Plug in the module, activate WLAN on the laptop, connect with Bridge-WLAN -> DONE
STEP-7 / TIA / WIN-CC / MICROWIN:
Each network device that speaks RFC1006 S7-TCP/IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP/IP and expands every MPI bus/PROFIBUS by a S5 network gateway.
It does not matter which control types, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- No expensive CP's needed for PLC-couplings.
- Supports remote maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S5 bridge can be used directly as a WLAN gateway for PLCs among each other device. Programming and visualizing S5 PLCs via WLAN is no longer a problem. Thanks to ext. Power supply usable on all controllers.
The S5 SPS Bridge with all functions is the perfect PLC network adapter for each application.
S5-Bridge is a reliable and handy S5-WIFI network adapter for every technician .
The compact design and the power supply directly from the CPU,
enable a PLC ** to be connected to the Ethernet in less than 5 minutes.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 8 watt |
Handling/Configuration: | rotary switch for the clock timer |
Operating temperature: | 5 - 40°C |
Case: | powder coated metal case |
Outside-dimensions: | 160 x 85 x 50 mm |
Arcing-chamber-dimensions: | 135 x 70 x 20 mm |
Scope of delivery: |
EPROM-ERASER UVL3 Power connector 2pins big |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
44,00 €
plus VAT. and shipping
plus VAT. and shipping
59,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
Memory modules / Prommer
Memory-modules
Memory-modules for SIMATIC® - S5&S7
Memory-modules for SIMATIC® - S5&S7
MULTI-PROMMER
programming device for S5 and S7-300/400 memory modules and Dual-In-Line (Multi-Prommer)
programming device for S5 and S7-300/400 memory modules and Dual-In-Line (Multi-Prommer)
MINI-PROMMER-III
programming device for S5 memory modules
programming device for S5 memory modules
FLASH-PROMMER-II-MMC
programming device for S5 and S7 memory modules
programming device for S5 and S7 memory modules
FLASH-PROMMER-II
programming device for S5 and S7 memory modules
programming device for S5 and S7 memory modules
EPROM-ERASER LG07
Erasing EPROM memory modules
Erasing EPROM memory modules
All prices plus costs of delivery, shipping insurance and VAT.
59,00 €
plus VAT. and shipping
plus VAT. and shipping
9363-5
MINI-PROMMER III 24VDC Obsolete
Successor: FLASH-PROMMER-II-MMC 24VDC (Art.No: 9363-8-MMC)
Programming device for S5 memory-modules Win7-support for S5D- and binary-files
MINI-PROMMER III 24VDC Obsolete
Successor: FLASH-PROMMER-II-MMC 24VDC (Art.No: 9363-8-MMC)
Programming device for S5 memory-modules Win7-support for S5D- and binary-files
0,00 €
plus VAT. and shipping
plus VAT. and shipping
145,00 €
plus VAT. and shipping
plus VAT. and shipping
9363-2
MULTI-PROMMER programming device Obsolete
Successor: FLASH-PROMMER-II-MMC 24VDC (Art.No: 9363-8-MMC)
for S5/S7 memory-modules, Win7-support for S5D-, S7P- and binary-files
MULTI-PROMMER programming device Obsolete
Successor: FLASH-PROMMER-II-MMC 24VDC (Art.No: 9363-8-MMC)
for S5/S7 memory-modules, Win7-support for S5D-, S7P- and binary-files
0,00 €
plus VAT. and shipping
plus VAT. and shipping
9363-5-USB
MINI-PROMMER III 24VDC, USB-bundle Obsolete
Programming device for S5 memory-modules Win7-support for S5D- and binary-files inclusive USB-RS232-converter-cable
MINI-PROMMER III 24VDC, USB-bundle Obsolete
Programming device for S5 memory-modules Win7-support for S5D- and binary-files inclusive USB-RS232-converter-cable
604,00 €
plus VAT. and shipping
plus VAT. and shipping
44,00 €
plus VAT. and shipping
plus VAT. and shipping