S5-BRIDGE
ONLINE with S5PLC without cable +++ S5-adapter 90-155U/CPs/IPs +++ No WIFi-infrastructure +++ Integrated access-point +++ Configuration via WebAccess +++ S5 Bridge (TTY - LAN - WIFI)
Universal LAN/WIFI-S7-Adapter
Also available as a set for universal use: S5/S7-BRIDGE-WIFI-SetsProduct Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
more...
ARTNR: 9352-S7-WIFI
S7-BRIDGE
EAN number: | 4260363249317 | |
HS-code: | 85423190 | |
Weight: | 0.6 kg |
S7
PPI-Bus | |||||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||||
USB | |||||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||||
LAN | |||||||||
10/100BaseTx |
x(7)
|
x
|
x
|
x
|
x
|
||||
WIFI | |||||||||
2.4 GHz |
x
|
||||||||
TeleService operation | |||||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||||
baud rates at TS-operation directly at the PC | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||||
baud rates at TS-operation directly with a modem | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x
|
x
|
|||||||
115.2 KBit/s |
x
|
x
|
|||||||
HMI | |||||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||||
PLCVCOM |
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
RFC1006 |
8
|
8
|
32
|
32
|
32
|
||||
AG connections (maximum) | |||||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||||
integrated PLC-firewall |
|
|
x
|
x
|
x
|
||||
display diagnostic-buffer in the webbrowser |
|
|
x
|
x
|
x
|
||||
webserver for configuration |
x
|
x
|
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
x
|
x
|
||||
galvanic separation | |||||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
1,5KV
|
1,5KV
|
mounting | |||||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||||
upgrading with | |||||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||||
supports | |||||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win11 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1 (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3 (3) only serial communication (4) Siemens Step7 V5.2 and higher dont run with this operationing system (5) USB-communication is only possible with the special driver for Win NT (6) USB 2.0 is backward compatible to 1.1 (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation (8) only in combination with the MPI-Speed-driver („continously-active“) (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional) (11) only in the mode: MultiMaster-Mode (12) up to a maximum baud rate of 187.5 KBit/s (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port. (14) with the use of the TS-adapter / item number: 9350.TS (15) Update directly with PC and TIC-driver (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens (19) only at PPI-communication possible (20) Only with TIC-driver (21) with integrated webserver possible (22) No support of Siemens Step7-software possible (23) Only with USB and with TIC-driver |
Product Overview:
Our S5-BRIDGE is the world's smallest WIFI gateway to all your S5 controllers.
With integrated WIFI and Ethernet interface, in one housing _, mobile access to all PLC systems is no problem.
Wireless access to the AS511, SI1, SI2 interface on all S5 controllers is no longer an obstacle, as is access to all other network components.
At the same time, the system works as a S5 network adapter for programming, remote maintenance and for coupling the various PLCs.
Thanks to the integrated S7 protocol, each HMI devices, e.g. current panel series, as well as any other S7-Ethernet device, can be connected directly via S7-TCP-IP via LAN & WIFI.
! Parallel access via LAN/WIFI thanks to included multiplexer !
Quite simply directly for all Siemens Step5, PG-2000, any other S5 package and WinCC projects.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-firmware-file
Configuration-tool / update-tool for Windows XP, 7/VISTA/8/10/11 32/64 bit:
download-S5-LAN-Manager inclusive PLC-firmware-file
Highlights:
- Parallel operation of several connections e.g. Remote maintenance, programming, visualization and much more is possible.
- Replacement for e.g. expensive CP
- Coupling to each ERP system e.g. about OPC logs.
- No PLC knowledge required
- Active module, thanks to its own power sources no influence on the S5.
- Communication with Fetch/Write
- Ideal for process visualization
- Open TCP/IP protocol
- RK 512 and TCP/IP H1-ISO-On-TCP RFC1006 (CP1430 TCP) supported
- Available in the variants 3964R-LAN, ASCII-LAN, PG-LAN, and for MUX757.
- Move around the machine without restrictions during commissioning or maintenance!
- Work where problems are visible and comprehensible!
Application areas:
- Commissioning of machines directly on PLC interface.
- Connection of mobile devices to the fieldbus system.
- Universal coupling of all PLC machines, no matter which interfaces are available!
- WIFI programming adapter for service applications, once parameterized, thanks to flash memory without data loss, independent of power failures.
- PUT/GET of S7-1500/1200/300/400 (PN-CPU or with Ethernet-CP), also ACTIVE , with specified and unspecified connection possible.
- VPN remote maintenance possible, to maintain the PLC via the Internet.
- Coupling with DB-Transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5-Gateway.
- any TCP device writes/reads DB`s in the S5 control.
Configuration:
- Easiest configuration through intuitive operation!
The S5 bridge is designed for fast commissioning .
After the module has been plugged into the plc, only assigne the IP address is via the S5-LAN Manager. After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
- Plug in the module, activate WLAN on the laptop, connect with Bridge-WLAN -> DONE
STEP-7 / TIA / WIN-CC / MICROWIN:
Each network device that speaks RFC1006 S7-TCP/IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP/IP and expands every MPI bus/PROFIBUS by a S5 network gateway.
It does not matter which control types, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- No expensive CP's needed for PLC-couplings.
- Supports remote maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S5 bridge can be used directly as a WLAN gateway for PLCs among each other device. Programming and visualizing S5 PLCs via WLAN is no longer a problem. Thanks to ext. Power supply usable on all controllers.
The S5 SPS Bridge with all functions is the perfect PLC network adapter for each application.
S5-Bridge is a reliable and handy S5-WIFI network adapter for every technician .
The compact design and the power supply directly from the CPU,
enable a PLC ** to be connected to the Ethernet in less than 5 minutes.
Wired or wireless communication (WIFI) via the same adapter with the respective control
Always connected to each other, all made possible by the devices of the BRIDGE-family.
Wired or wireless communication (WIFI) via the same adapter with the respective control
Always connected to each other, all made possible by the devices of the BRIDGE-family.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 3 watt |
Display: |
Web-Browser 3 status-LEDs (of that 1 double-led) |
Handling/Configuration: |
Web-Browser TIC-Software Configuration-tool |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
PD/diagnosis jack10/100BaseTX RJ45-ethernet jack Antenna-plug RP-SMA(f) (IEEE 802.11 b/g/n) |
Galvanic separation: | 1500V PPI/MPI/Profibus to the PC |
Operating systems: | MS-Windows NT, 2000, XP, Vista / Win7/8/10/11 32/64 Bit |
Protocols: | RFC1006, DHCP, HTTP |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 120 x 43 x 17 mm |
Scope of delivery: |
S7-BRIDGE-module WIFI-stub antenna Power connector 2pins small |
accessories:
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Stationary antenna for wall fastening
for ALF and CONNECT-ROUTER, cable length: 2,5m for indoor and outdoor use incl. wall holder
plus VAT. and shipping
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
plus VAT. and shipping
plus VAT. and shipping
Sector antenna for ALF
Sector antenna with 17dBi power gain and bundled radiation. Connection cable optional
plus VAT. and shipping
Beam antenna for ALF
Beam antenna with 17dBi power gain for classic radio link connection cable optional
plus VAT. and shipping
plus VAT. and shipping
Magnetic base antenna for indoor use
for ALF, ALF-UA- S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m
plus VAT. and shipping
plus VAT. and shipping
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
plus VAT. and shipping
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
plus VAT. and shipping
S7-BRIDGE
Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI
plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping
S7-GATE connector with integrated firewall for Siemens S7-PLCs
Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
plus VAT. and shipping
S7-LAN++ connector for Siemens S7 Controller
Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
plus VAT. and shipping
LAN
smallest simatic S7 ethernet gateway with PD-socket, multifunctional, 1 adapter for all PPI, MPI and Profibus applications
with ext. 24V-connector
easy remote maintenance over internet
S7-cable PPI/MPI/PROFIBUS +++ Ethernet-gateway S7 as cable +++ Network for each S7-PLC +++ Parallel LAN access +++ Ethernet for each S7-PLC
WLAN/WIFI
Service-suitcase for couppling to a PLC over LAN/WLAN incl. all accessories
Over WLAN to PLC and ethernet-communication-modules
S7-adapter PPI/MPI/PROFIBUS +++ including PLC-firewall +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN++ Connector with integrated firewall for Siemens S7-PLCs
plus VAT. and shipping
plus VAT. and shipping
Magnetic base antenna for indoor use
for ALF, ALF-UA- S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m
plus VAT. and shipping
plus VAT. and shipping
Automatic-mode
Main downloads
Versionstory
Documentation
- Short instruction
- Example PUT/GET for Simatic-Manager and TIA-portal
- Examples of S5-/S7-coupling (S5-PLC and/or S7-PLC active)
- Information-sheet S7-LAN
- Handbook S5-/S7-BRIDGE
- Short instruction S7-interface (german only)
- Short instruction S7-LAN
- Example of use: Watchdog-option
- Handbook S7-LAN (older version)