PG-ISO-set


PLC-communication with 1000V galvanic separation without power supply
Interface cable set with galvanic separation
between PC and PLC up to 1000V
- Galvanic separation between PD/PC and PLC up to 1kV
- Contact-protected plastic housing
- Supply of the module from the PLC voltage 5V DC and/or 24V DC
- The SET contains a PG-UNI-Kabel (3m) Art.Nr.9359-3 and a PG-ISO-Adapter Art.Nr.9359-8
- Slide lock for firm grip on the PLC
more...
variants:
ARTNR: 9359-S
PG-ISO-SET 3m
162,00 € plus VAT. and shipping
ARTNR: 9359-S
PG-ISO-SET 3m
| EAN number: | 4260363240604 | |
| HS-code: | 85444290 | |
| Weight: | 0.2 kg |
Alternativen
162,00 €
plus VAT. and shipping
plus VAT. and shipping
185,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-S.10M
PG-ISO-SET 10m
Interface cable set with galvanic separation between PC and PLC up to 1000V
PG-ISO-SET 10m
Interface cable set with galvanic separation between PC and PLC up to 1000V
208,00 €
plus VAT. and shipping
plus VAT. and shipping
9310
Additional charge 25-pins PC-plug
Special construction of the RS232-side with 25pin D-Sub female with screwing locks
Additional charge 25-pins PC-plug
Special construction of the RS232-side with 25pin D-Sub female with screwing locks
39,00 €
plus VAT. and shipping
plus VAT. and shipping
69,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-5-150
AG-150-adapter
for PG-UNI + PG-UNI-II-cable + S5-LAN++ (up to HW2.2) with Netz-Adapter to AG-150
AG-150-adapter
for PG-UNI + PG-UNI-II-cable + S5-LAN++ (up to HW2.2) with Netz-Adapter to AG-150
46,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
21,00 €
plus VAT. and shipping
plus VAT. and shipping
21,00 €
plus VAT. and shipping
plus VAT. and shipping
12,00 €
plus VAT. and shipping
plus VAT. and shipping
Programming adapter S5
| device type | ||||||
| S5-90U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
| S5-95U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
| S5-100U |
x
|
+ext. 24V(3)
|
+ext. 24V
|
x
|
x
|
x
|
| S5-115U |
at 944 + 9359-8
|
at 944 + 9359-8 + ext. 24V (4)
|
x
|
x
|
x
|
x
|
| S5-135U |
at 928B + 9359-8
|
at 928B + 9359-8 +ext. 24V (6)
|
x
|
x
|
x
|
x
|
| S5-155U |
x
|
x
|
x
|
x
|
x
|
x
|
| S5-AG110S |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
| S5-AG130W/B |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
| S5-AG150A/K/S/U |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
| CP-143 |
x
|
x
|
x
|
|||
| CP-521 |
+CP521 adapter
|
+CP521 adapter(1)
|
||||
| CP-523 |
+CP523 adapter
|
+CP523 adapter(1)
|
||||
| CP-525 |
+9359-5(1)
|
|||||
| CP-526 |
x
|
x
|
x
|
|||
| CP-527 |
x
|
x
|
x
|
|||
| CP-528 |
x
|
x
|
x
|
|||
| CP-544 |
x (7)
|
x (7)
|
x (7)
|
|||
| CP-5430 |
x
|
x
|
x
|
|||
| CP-5431 |
x
|
|||||
| IP-246 |
x
|
x
|
x
|
|||
| IP-247 |
x
|
x
|
x
|
|||
| IP-252 |
x
|
x
|
x
|
|||
| IP-266 |
x
|
+9359-4(1)
|
||||
| WF-470 |
+9359-5-WF470 + 9359-4(1)
|
|||||
| SIN-805 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
| SIN-820 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
| SIN-840 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
| SIN-850 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
| SIN-880 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
| Connection on PC |
RS232-port
|
Ethernet RJ45
|
Ethernet RJ45 / WLAN/WIFI
|
USB-port type A
|
RS232-port
|
RS232-port
|
| max. prolongation: | 300m (UNI-extension) | 300m (S5-LAN-extension) +ext. 24V | 100m (PG-USB-extension) | 300m (UNI-extension) | ||
|
(1) ISO adapter can not be used because the required supply voltage on the PG interface of the module is not present. (2) At the CPU 6ES5 102-8MA02 Release 3 is a PG-ISO-Adapter or Netz-Adapter additional required. (3) With S5-LAN++ from HW V2.3 [2010] the "Netz-Adapter" is no more needed, this version has included current-sources. (4) With S5-LAN++ from HW V2.3 [2010] no accessories are needed, this version has included current-sources. (5) With S5-LAN++ from HW V2.3 [2010] the Sinum-Adapter 9359-6-USB is needed. (6) Only for CPU928B with PG-ISO-Adapter and ext. 24V DC, unless there is an S5-LAN++ from HW V2.3 [2010] used. (7) CP544 has bolts at the programming-interface. The products do not fit 100% on this interface. (8) With S5-BRIDGE the Sinum-Adapter 9359-6-USB is needed. |
||||||
- Galvanic separation between PD/PC and PLC up to 1kV
- Contact-protected plastic housing
- Supply of the module from the PLC voltage 5V DC and/or 24V DC
- The SET contains a PG-UNI-Kabel (3m) Art.Nr.9359-3 and a PG-ISO-Adapter Art.Nr.9359-8
- Slide lock for firm grip on the PLC
Galvanic coupling to the S5-PLC (CPU-assemblies 15pin)
S5-PLC-communication, high-quality PC and fear of interfaces, unsure whether the PLC is grounded or the PLC is in an unsafe environment. Galvanic-separation
is the most practical solution. "PG-ISO-Set" (PG-UNI-cable + PG-ISO-adapter) galvanically separates the coupling to the connected S5-PLC, offers protection of the
PCs up to a voltage difference of 1000V.
If galvanic-isolation is not required, remove the PG-ISO-adapter and use the PG-UNI-cable like a standard S5-interface-cable.
No external supply necessary, function on 15-pin PG-interfaces. Earth objects between the PC and the S5-PLC are separated.
If galvanic-isolation is not required, remove the PG-ISO-adapter and use the PG-UNI-cable like a standard S5-interface-cable.
No external supply necessary, function on 15-pin PG-interfaces. Earth objects between the PC and the S5-PLC are separated.
| Supply voltage: | 5V/DV and/or 24V DC +/- 20% |
| Power consumption: | 0,3 watt |
| Display: | - |
| Interfaces: |
to the PLC:
TTY/20mA current loop (PG-COM passiv, PLC aktiv)
to the PD/PC:
RS232: 9,6 KBd - 115,2 KBd |
| Operating temperature: | -30 - +55°C |
| Case: | plastic case |
| Dimensions: | PG-UNI: 47 x 40 x 15 mm / PG-ISO-Adapter: 50 x 45 x 15 mm |
| Scope of delivery: |
PG-ISO-adapter PG-UNI-cable |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
9310
Additional charge 25-pins PC-plug
Special construction of the RS232-side with 25pin D-Sub female with screwing locks
Additional charge 25-pins PC-plug
Special construction of the RS232-side with 25pin D-Sub female with screwing locks
39,00 €
plus VAT. and shipping
plus VAT. and shipping
69,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-5-150
AG-150-adapter
for PG-UNI + PG-UNI-II-cable + S5-LAN++ (up to HW2.2) with Netz-Adapter to AG-150
AG-150-adapter
for PG-UNI + PG-UNI-II-cable + S5-LAN++ (up to HW2.2) with Netz-Adapter to AG-150
46,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
46,00 €
plus VAT. and shipping
plus VAT. and shipping
21,00 €
plus VAT. and shipping
plus VAT. and shipping
21,00 €
plus VAT. and shipping
plus VAT. and shipping
12,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
162,00 €
plus VAT. and shipping
plus VAT. and shipping
185,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-S.10M
PG-ISO-SET 10m
Interface cable set with galvanic separation between PC and PLC up to 1000V
PG-ISO-SET 10m
Interface cable set with galvanic separation between PC and PLC up to 1000V
208,00 €
plus VAT. and shipping
plus VAT. and shipping
S5 over RS232
PG-COMCouples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
PG-UNICouples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
PG-UNI IICouples the PC (9 pol. COM-interface) with the 15 pol. X4/X5 interface port of the PLC
S5toMPIConnects the S5-PLC with a S7-PLC
All prices plus costs of delivery, shipping insurance and VAT.
104,00 €
plus VAT. and shipping
plus VAT. and shipping
104,00 €
plus VAT. and shipping
plus VAT. and shipping





PI-Service-Mail

ask technician:
same day









