Cookies help us in providing our services. By using our services, you agree that we set functionally necessary cookies.
Optional cookies that are used for statistical or marketing purposes will only be set after your consent.

       
OK
TELE-PROFessional-II (TP-II) - Process Informatik Entwicklungsgesellschaft mbH

TELE-PROFessional-II (TP-II)


Programming of S5- and S7-PLC’s via telephone from afar

OEM - Version (all accessories optional)
without PCMCIA-Slot for UMTS-/LAN-card

  • Secured modem-protocol, no additional software needed
  • UMTS- / VPN- / internet-service
  • Also for PLC’s with ProfiNet
  • SMS and fax sending directly from S7-300/400 (no PLC-programming necessary)
  • Analogue modem couples automatically via ISDN

more...
variants:

1260,00 € plus VAT. and shipping

ARTNR: 9372-OEM
TELE-PROFessional II worldwide use
EAN number: 4260363240062
HS-code: 85389099
Weight: 1.8 kg



Remote maintenance

TELE LINK NETWORK
         
 
secured modem-protocol
additional software needed
Siemens TS -Software
Siemens TS -Software
VPN-Client
VPN-Client
Providing WinTELEPROF-software
modem
analogue/ISDN
analogue
opt. via PCMCIA
analogue/GSM
analogue/ISDN/GSM
internet-connection
internet-connection
internet-connection
modem for world wide use
interfaces
MPI/Profibus
9600-12MBd
9600-12MBd
9600-12MBd
9600-12MBd
RS232
2x
2x
2x
1x
1x
TTY
2x
2x
2x
1x
PCMCIA
2x (optionally)
1x
1x
Ethernet
10/100BaseTx
1x
1x
5x
USB
2x
1x
LCD-display
instead 10 LEDs
instead status-LED
instead webserver
instead webserver
supported PLC-protocols *
S7
S5
✓ (optional)
✓ (optional)
Pilz PSS
✓ (optional)
✓ (optional)
Allen-Bradley
✓ (optional)
✓ (optional)
AEG
✓ (optional)
✓ (optional)
Bosch
✓ (optional)
✓ (optional)
Telemecanique
✓ (optional)
✓ (optional)
GE-Fanuc
✓ (optional)
✓ (optional)
Klöckner-Moeller
✓ (optional)
✓ (optional)
Mitsubishi
✓ (optional)
✓ (optional)
SMS-sending/Pager(S5/S7)
✓ (no pager)
only for analogue / ISDN
HMI-messaging module(S5/S7)
SMS-receive with GSM
DTMF with analogue
e-mail-dispatch
FAX-dispatch(S5/S7)
✓ (optional)
✓ (optional)
only for analogue / ISDN
PLC-data coupling(S5/S7)
✓ (optional)
✓ (optional)
ASCII-transfer from S5/S7
✓ (optional)
✓ (optional)
only with ASCII-LAN
internet-coupling
Usage as dial-up-router
power supply
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
24V/DC
dimensions w x h x d (in mm)
High: 67 x 280 x 170
FLAT: 300 x 175 x 70
300 x 175 x 66
235 x 162 x 37
90 x 162 x 54
40 x 125 x 115
42 x 15 x 65
65 x 43 x 17
154 x 92 x 28

* other PLC types on request

Karl Roll GmbH & Co. KG
Mühlacker - Enzberg
www.karl-roll.de

Wöhrle Belgium B.V.B.A.
Mechelen , Belgium
www.wohrle.be

Junger GmbH
Gütersloh
www.junger-gmbh.de
  • Secured modem-protocol, no additional software needed
  • UMTS- / VPN- / internet-service
  • Also for PLC’s with ProfiNet
  • SMS and fax sending directly from S7-300/400 (no PLC-programming necessary)
  • Analogue modem couples automatically via ISDN
  • With integrated CP-343-1 / 443-1 functionality
  • Ethernet also for router function
  • PCMCIA-slots (only for version -H) for extensions (memory cards / specific modem cards (GSM) / WLAN)
  • Compatible to the forerunner model (TELE-Prof / TELE-Book / TELE-Link)
  • Also as TCP/IP-router
  • S7-variables display via Web-Browser
  • S7-remote maintenance with MPI-Interface
  • S5-remote maintenance (access to every S5 direct / via H1, L1, L2 and KOR/MUX)
  • Integrated telephone directory
  • Call-back of partner possible
  • Software-update via PC (LAN) respectively from device to device possible
Remote maintenance / telecontrol of PLC
Produkbild
Access to the connected PLC takes place by coupling via Analogue-, ISDN-, mixed Analogue-ISDN-, GSM-, UMTS-line and also via Internet with and without VPN-security.
Analogue and ISDN - how do they come together?
Produkbild

You have on the plant side only ISDN for telephone, but in your office there is only an analogue system? No problem, you have to install on the clients side the TP-II and activate there the analogue-emulation in the device. No, the modem signals will be send digitalized over ISDN and you can connect to it. So, you will be able to communicate though the telephone systems are different and your client isn´t forced to install an analogue connection.

Router - Mode (access to the network without router)
Produkbild
The Tele-Prof-II can also be used as a router for access from a PC via dial-up connection, so that a communication with the behind covered network results. Furthermore a network connection can be made with the TP-II <=> TP-II-line, but in doing so the IP-address-root must differ.
User dependant network access
Produkbild
You have PLC/LAN-participants different supplier in your network and everybody should have access to this network? No problem, you give every supplier a VPN-username and passwort, define in the destination device a user-dependent network-access and after positiv login he only can communicate to the released ip-addresses.
Separate your machine-net from the office-net
Produkbild
You need a separation between the machine-net and the office-net? No problem, plug a PCMCIA-LAN-card in your Tele-Prof-II-device (only for version -H) and the separation is OK. You have access to both nets via remote maintenance.
S7-CP-alternate (without LAN-CP to the PLC)
Produkbild
Do you have a PLC without CP343-1 or CP443-1 and a TP-II as remote maintenance device? Then activate the CP-mode of the TP-II and your visualisation goes directly ONLINE via the LAN of the TP-II.
PLC coupling (data exchange between PLCs)
Produkbild
Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Thereto no dedicated line is required, a “normal” telephone connection is sufficient because the devices cut the line after occured message.
Failure report transmission without any change in the PLC programm
Produkbild
Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, as SMS to your mobile phone, to your pager or also via e-mail. And this without an intervention of the PLC-program. Here the variables and actions are stored and processed in the TP-II.
Failure report transmission released by the PLC
Produkbild
Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, as SMS to your mobile phone, to your pager or also via e-mail.
Remote maintenance of centralized PLC-devices
Produkbild
You have many PLC and you want to programm them central on one place? No problem, you have to connect them all to the KOR/MUX-Tele-Switch, connect it with the TP-II and after telephone connect you will be able with the PD-bus-selection of your Step5-software to go ONLINE. Of course the MOR/MUX-Tele-Switch is cascadable, so you can connect up to 30 PLCs to the devices.
Sending ASCII-data to a PC
Produkbild
Your car park or control sends the configuration / capacity utilisation to a PC with a modem, so that the data can be used for further processing.
Direct-mode "extended serial interface"
Produkbild
There is an unsupported control or data logger or converter integrated in your installation which protocol is not supported? No problem, the signs that the PC in the office sends will be transferred via telephone line by the Direct-mode, and on-site reproduced by the TP-II. The way back is identical. So in that case there’s also a communication to the electronic devices available.
Data logger with FTP-interface
Produkbild
You need a data logger which tape-records the specified data of the PLC and you can collect the data via FTP on demand. No problem, TP-II with the option Datalogger is the solution for you.
Supply voltage: 24V DC +/- 20%
Power consumption: 15 watt
Display: expressive LCD display
5 status LEDs
Handling/Configuration: integrated keypad
WEB-Browser
Interfaces:
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
TTY/20mA current loop (AG-TELE aktiv, PLC passiv)
RS232: 9,6 KBd - 115,2 KBd / fully assigned
to the PD/PC:
10/100BaseTX RJ45-ethernet jack
TTY/20mA current loop (100 % mechanically and electr. compatible)
RS232: 9,6 KBd - 115,2 KBd / with a 1on1-cable to the PC
others:
2xUSB, 2xPCMCIA (only for version -H)
Integrated modem: 33K6 HIGH-SPEED, V.42/BIS MNP5 analogue modem
ISDN (Euro ISDN + 1TR6)
Operating temperature: 0 - 55°C
Case: powder coated metal case with mounting flange and DIN-rail mounting
Dimensions: Flat 300 x 175 x 70 mm
Hoch 67 x 280 x 170 mm
 
Scope of delivery: Tele-Prof-II
Power connector 3pins big
All prices plus costs of delivery, shipping insurance and VAT.

accessories:

244,00 €
plus VAT. and shipping


9361-3.10M
S5-connecting cable 10m

for TELE-PROF, MINI-/PG-MUX-II
9361-3
S5-connecting cable 3m

forTELE-PROF, MINI-/PG-MUX-II
9361-3.05M
S5-connecting cable 5m

for TELE-PROF, MINI-/PG-MUX-II
9361-3.06M
S5-connecting cable 6m

for TELE-PROF, MINI-/PG-MUX-II
9352.1
USB-cable plug/plug type A-A 3m

USB 1.1 / 2.0 up to 480 MBit
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


172,00 €
plus VAT. and shipping


9391-MT
Mounting set

for DIN-rail-holder, self mounting
Quickbestellung INFOMAIL
by e-mail
27,00 €
plus VAT. and shipping


9379.1
MPI-/Profibus connecting cable 1m

connects MPI-modem/TP-II with the S7-PLC
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


9370-8-ISDN
Phone-cable ISDN

RJ45 plug <=> RJ45 plug, assigned 1to1
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


9391.1
24V DC power-supply unit 625mA

Primary 110V - 240 VAC Euro+USA-plug
Quickbestellung INFOMAIL
by e-mail
59,00 €
plus VAT. and shipping


9370-8-D/USA
Phone-cable analogue Germany+USA

RJ12 plug <=> RJ12 plug with TAE-adapter for Germany
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


9372-24
Power connector 3pins big

connector plug lockable by jack with screws
Quickbestellung INFOMAIL
by e-mail
4,00 €
plus VAT. and shipping


9636-TCPIP
Patch-cable 3m, Cat5+, shielded

RJ45 plug <=> RJ45 plug, 1:1
9636-CROSS
Cross-cable 3m Cat5+, shielded

RJ45 plug <=> RJ45 plug, twisted pinning
9372-UMTS-Ant
UMTS directional antenna
external antenna for the UMTS-card
Quickbestellung INFOMAIL
by e-mail
199,00 €
plus VAT. and shipping


9371-6
Servicebag

for TP, TB + TP-II-FLAT
Quickbestellung INFOMAIL
by e-mail
63,00 €
plus VAT. and shipping


9370-8-IT
Special phone-cable for Italy

Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-GB
Special phone-cable for Great Britain

RJ12 plug <=> telephone plug of Great Britain
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-CH
Special phone-cable for Switzerland Obsolete

RJ12 plug <=> telephone plug of Switzerland
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-AT
Special phone-cable for Austria Obsolete

RJ12 plug <=> telephone plug of Austria
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-NL
Special phone-cable for Netherlands

RJ12 plug <=> telephone plug of the Netherlands
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-DK
Special phone-cable for Denmark

RJ12 plug <=> telephone plug of Denmark
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-FR
Special phone-cable for France

RJ12 plug <=> telephone plug of France
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-8-BE
Special phone-cable for Belgium

RJ12 plug <=> telephone plug of Belgium
Quickbestellung INFOMAIL
by e-mail
25,00 €
plus VAT. and shipping


9370-TAE
TAE junction box

analogue telephone box (NFN) for on-wall mounting
Quickbestellung INFOMAIL
by e-mail
22,00 €
plus VAT. and shipping


9359.1:1
1:1 cable 9pins D-SUB

D-SUB 9pins (male) <=> D-Sub 9pins (female), 1to1-assignment
Quickbestellung INFOMAIL
by e-mail
28,00 €
plus VAT. and shipping


9372-LANCARD
Network-card for TP-II Obsolete

Ethernet networkcard Cardbus PCMCIA 10/100
Quickbestellung INFOMAIL
by e-mail
105,00 €
plus VAT. and shipping


All prices plus costs of delivery, shipping insurance and VAT.

9372-OEM
TELE-PROFessional II worldwide use

OEM - Version (all accessories optional) without PCMCIA-Slot for UMTS-/LAN-card
Quickbestellung INFOMAIL
by e-mail
1260,00 €
plus VAT. and shipping




maximum 3 articles
9372-FLAT
TELE-PROFessional II worldwide use

flat version / OEM - Version (all accessories optional) without PCMCIA-slot for UMTS-/LAN-card
Quickbestellung INFOMAIL
by e-mail
1260,00 €
plus VAT. and shipping




maximum 3 articles
9372-OEM-H
TELE-PROFessional II worldwide use
OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
Quickbestellung INFOMAIL
by e-mail
1313,00 €
plus VAT. and shipping


9372-FLAT-H
TELE-PROFessional II worldwide use
flat version / OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
Quickbestellung INFOMAIL
by e-mail
1313,00 €
plus VAT. and shipping


All prices plus costs of delivery, shipping insurance and VAT.

9370-8-D/USA
Phone-cable analogue Germany+USA

RJ12 plug <=> RJ12 plug with TAE-adapter for Germany
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


9352-LANCON
S7-LAN connector for Siemens S7 PLC controller

Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
Quickbestellung INFOMAIL
by e-mail
423,00 €
plus VAT. and shipping


9359-LAN
S5-LAN++

Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
Quickbestellung INFOMAIL
by e-mail
452,00 €
plus VAT. and shipping


9359-1.05M
PG-USB-cable 5m for Siemens S5 Controller

for PLC's + LED + metal case
Quickbestellung INFOMAIL
by e-mail
174,00 €
plus VAT. and shipping


9379.1
MPI-/Profibus connecting cable 1m

connects MPI-modem/TP-II with the S7-PLC
Quickbestellung INFOMAIL
by e-mail
11,00 €
plus VAT. and shipping


9359-1
PG-USB-cable 3m for Siemens S5 Controller

for PLC's + LED + metal case
Quickbestellung INFOMAIL
by e-mail
145,00 €
plus VAT. and shipping